Document byNqx5Yd5bxv0kX4Mmvp2On01
Original Articles
A Quantitative Method for Estimating Dermal Benzene Absorption from Benzene-containing Hydrocarbon Liquids
STEPHEN E. PETTY, MARK NICAS, ANTHONY A. BOIARSKI
This study examines a method for estimating the dermal absorption of benzene contained in hydrocarbon liquids that contact the skin. This method applies to crude oil, gasoline, organic solvents, penetrants, and oils. The flux of benzene through occluded skin as a function of the percent vol/vol benzene in the liquid is derived by fitting a curve to experimental data; the function is supralinear at benzene concentrations 5% vol/vol. When a liquid other than pure benzene is on nonoccluded skin, benzene may preferentially evaporate from the liquid, which thereby decreases the benzene flux. We present a time-averaging method here for estimating the reduced dermal flux during evaporation. Example calculations are presented for benzene at 2% vol/vol in gasoline, and for benzene at 0.1% vol/vol in a less volatile liquid. We also discuss other factors affecting dermal absorption. Key words: benzene; dermal; exposure; modeling; quantification; flux; gasoline; mineral spirits; crude oil
INT J OCCUP ENVIRON HEALTH 2011;17:287300
INTRODUCTION
Benzene, a human carcinogen, has long been recognized as a component of crude oil, gasoline, petroleumderived solvents (e.g., hexane, heptane, toluene, xylene, naphtha, mineral spirits), and other chemical products (e.g., penetrants and degreasers). Benzene is dermally absorbed when pure benzene or a benzenecontaining liquid is in contact with the skin. The benzene mass absorbed depends on 1) the benzene con-
Received from: Engineering & Environmental Services, Inc. (EES Group, Inc.), Dublin, Ohio, USA (SP, AB); School of Public Health, University of California, Berkeley, California, USA (MN). Send correspondence to: Stephen Petty, EES Group, Inc., 6321 Ireland Place, Dublin, OH 43016; email: <Stephenpetty@eesinc.cc>.
Disclosures: All three authors have served as expert witnesses in litigation related to occupational exposures, including those associated with exposure to benzene. No outside funding was received from any legal firms by the authors in the preparation or completion of this manuscript nor was any input received during the preparation or completion of this manuscript.
centration in the hydrocarbon liquid; 2) the composition of the liquid; 3) the condition and body location/area of the skin; and 4) the duration of exposure.1 Although inhalation of benzene vapor has traditionally received the most attention, more consideration is now being given to dermal exposures to benzene,2,3 and to chemical contaminants, in general.4,5
For example, Sahmel, Boeniger, and Fehrenbacher5 estimated benzene dermal absorption for automotive repair workers who used gasoline containing 2% benzene. They calculated that approximately 92% of the total daily benzene absorbed dose was due to dermal exposure. In making this estimate, they assumed that 1% of the benzene in the volume of gasoline contacting the skin was absorbed. The 1% value was based, in part, on the observations that 0.13% of pure benzene placed in a nonoccluded manner on human palmar skin is absorbed; damaged primate skin permits fivefold more benzene absorption in vivo than does nondamaged skin; and workers with frequent hand contact with solvents have damaged skin.
In the previous example, the mechanics' skin was nonoccluded, that is, open to the air. When benzene contacts nonoccluded skin, benzene evaporation limits the time over which the benzene can permeate into the skin. However, OSHA noted that where benzene is kept against the skin due to wetted clothing or gloves, benzene would not evaporate as quickly as it does on nonoccluded skin.6 Due to the longer contact time in the occluded case, the percent of benzene absorbed could be substantially greater than the 1% it was for the nonoccluded case.
The benzene content in the portion of gasoline and other hydrocarbon fuels that permeate through nitrile and neoprene gloves was found to be enhanced above the content in the original bulk fuel.7 Using seven glove types (latex, nitrile, vinyl, nitrile-Sol-Vex, neoprene, Viton, and SRM), the authors found that gasoline had breakthrough times of 2.1, 0.9, 208.1, 22.4 and 4.9 minutes for nitrile, vinyl, nitrile-Sol-Vex, neoprene, and SRM, respectively. Latex glove breakthrough data for gasoline was not determined, but it was rated the poor-
287
est of the seven materials based on results for three other fuels. Thus, except for the nitrile-Sol-Vex material, the gloves provided less than five minutes' protection from gasoline. Perhaps more importantly, when the gasoline broke through, the amount of benzene in the gasoline was found to be enhanced by factors of ~2 and ~2.5 for neoprene and nitrile glove types, respectively.
The objective of this paper is to provide a scientifically sound method for estimating the dermal absorption of benzene due to skin contact with benzene-containing liquids. The focus is on the relationship between the benzene concentration in the liquid and the rate of benzene permeation, while accounting for benzene absorption as the benzene concentration in the liquid on the skin decreases due to preferential evaporation.
DERMAL EXPOSURE MODEL FOR BENZENE IN LIQUID
Dermal Dose from a Benzene-containing Liquid during Exposure without Benzene Loss
In some scenarios, a benzene-containing liquid continually contacts the skin during the exposure event, and benzene evaporation from the liquid (and absorption through the skin) negligibly changes the benzene concentration in the liquid on the skin. For example, a worker might submerge a hand in a container of the liquid or hold a rag wet with the liquid against the palmar surface. In this case, the dermally absorbed dose for the exposure event, DAnoevap (mg), can be estimated by the following equation8:
Eq. 1: DAnoevap = Kp CB SA FAabs ET
where Kp is the permeation coefficient (cm/hr) of benzene through skin referenced to a specific skin site and a specific liquid, CB, is the benzene concentration (mg/ cm3) in the liquid, SA (cm2) is the surface area of the wetted skin, FAabs is a skin site absorption factor (no units), and ET (hr) is the duration of the exposure event.
FAabs = 1 is used for most skin areas, but this factor can be greater or lesser than 1 for specific skin areas of interest. For example, data suggest that benzene can be absorbed at a greater rate on the palm than on the forearm.9 The total benzene mass absorbed over a series of such exposure events is the sum of the DAnoevap values for the respective individual events, although primate data indicate that successive episodic benzene exposures lead to increased absorption in the later exposures.10 Note that the parameter "flux" is the mass absorbed per unit skin surface area per unit time (typically, mg/cm2-hr), and equals the product of Kp and CB:
Eq. 2: Flux = Kp CB
Dermal Dose from a Benzene-containing Liquid during Exposure with Benzene Loss
In some scenarios, a benzene-containing liquid contin-
ually contacts the skin during the exposure event, but
benzene evaporation from the liquid substantially
changes the concentration of benzene in the liquid.
For example, liquid may splash directly onto the
worker's nonoccluded skin, or, following immersion of
the hands in liquid containing a constant CB value, the skin may remain wet before the worker dries off the
skin or before the liquid evaporates completely. If the
benzene evaporates at a faster rate than the major com-
ponent(s) of the liquid, CB decreases during the exposure event. Although benzene continues to be
absorbed from the liquid, the flux decreases because
CB decreases, as shown by equation 2. Where benzene evaporates from the liquid during
an exposure event of duration ET (hr), the time-
weighted-average (TWA) benzene concentration CB,TWA in the liquid is given by:
ET
Eq. 3:
CB,TWA
=
__1_ ET
0
CB(t)dt
where CB(t) is the benzene concentration in liquid as a function of time. In turn, the CB,TWA value permits approximating the benzene dose absorbed during the
exposure event by the expression:
Eq. 4: DAevap Kp CB,TWA SA FAabs ET
The product Kp CB,TWA estimates the time-averaged flux, FluxTWA. As will be explained, the more exact method of computing FluxTWA involves integrating a nonlinear function for benzene flux over the exposure interval ET. Finally, if an exposure period involving continuous contact with a liquid with a constant CB value (for example, skin contact with fresh liquid) is immediately followed by an exposure period involving continuous contact with liquid containing a decreasing CB value (for example, wetted clothing held against the skin), the total benzene dose absorbed is the sum of DAnoevap and DAevap.
BENZENE IN GASOLINE
We discuss skin contact with gasoline because it was
(and likely continues to be) a frequent event in some
occupations, and because data are available to permit
estimating the CB(t) function in gasoline. The time course of gasoline evaporation in a 13.9-cm petrie dish at 20 to 22 C was experimentally measured by Fingas.11
Hereafter, it was assumed that the temperature was 21 oC. The percent of the initial gasoline volume remain-
ing with time is shown by the open circles in Figure 1.
288 Petty et al.
www.ijoeh.com INT J OCCUP ENVIRON HEALTH
Figure 1--Evaporation data for gasoline at 20 to 22 C and benzene at 24 C; the solid-line curve corresponds to equation 5.
Figure 2--The evaporation of gasoline at 21 C, at 25 C and at 32 C; the open circles are the values reported by Fingas, and the dashed-line curve corresponds to equation 5.
For comparison, evaporation data for pure benzene at 24 C are also shown in Figure 1 by the open squares; the benzene data were generated by placing the liquid in a 6.5-cm pan with filter paper on the bottom surface.12 Although there is a difference of several C between the two evaporation time series and a difference in the experimental methods, the rate of loss of the initial 40% to 50% of the liquid volume is similar for gasoline and benzene. As will be described in more detail, Runion13 reported that the percent vol/vol benzene content of gasoline remained fairly constant over the evaporation of the initial 40% to 50% of the gasoline volume, and thereafter decreased in an approximate linear fashion toward zero. The evaporation time series in Figure 1 are consistent with Runion's findings.
The Figure 1 gasoline data are well described as a double exponential (biphasic) process with an early first-order rate constant 1 = 0.095 min1, and a subsequent first-order rate constant 2 = 0.0095 min1. Figure 2 shows a more complete time series of the Fingas data for the percent of the initial gasoline volume remaining at time (t) at 21 C, denoted %VG,21C(t), and also shows the biphasic curve (the dashed-line curve), which is specified by the following equation:
Eq. 5: %VG,21C(t) = 40.1% exp(0.095 t) + 59.9% exp(0.0095 t)
Runion13 measured the evaporation of benzene from gasoline at 25 C, but reported the data as the percent vol/vol benzene (%CB) in gasoline as a function of the volume percent of the initial gasoline remaining. However, we seek to estimate the %CB in gasoline as a function of time at 32 C for two reasons. First, the average temperature of the skin on a person's hands is 32
C.14,15 Second, equation 3 shows that specifying %CB(t) would permit computing the %CB,TWA value.
The first step was adjusting the gasoline evaporation function at 21 oC for the higher temperatures of 25 oC and 32 oC. The Fingas and Runion papers did not specify the Reid vapor pressure (RVP) of the study gasolines, so regulatory limits on RVPs for gasoline were considered, which ranged from ~7 to ~9. For gasoline with RVPs from 7 psi to 9 psi, and at a temperature of 25 oC versus 21 oC, the respective vapor pressure ratio is a constant 1.15.16 Using this vapor pressure ratio, both 1 and 2 were increased in equation 5 by 1.15fold to account for the effect of increased temperature on the evaporation rate. In Figure 2, the solid-line curve labeled 25 oC shows the predicted evaporation time course specified by the following equation:
Eq. 6: %VG,25C(t) = 40.1% exp(0.109 t) + 59.9% exp(0.0109 t)
For gasoline with RVPs ranging from 7 psi to 9 psi and at an air temperature of 32 oC versus 21 oC, the respective vapor pressure ratios ranged from 1.43 to 1.45.16 On average, the ratio of the higher to the lower vapor pressure was 1.44, so both 1 and 2 were increased in equation 5 by 1.44-fold to account for the effect of increased temperature on the evaporation rate. In Figure 2, the solid-line curve labeled 32 oC shows the predicted evaporation time course specified by the following equation:
Eq. 7: %VG,25C(t) = 40.1% exp(0.137 t) + 59.9% exp(0.0137 t)
The second step was converting the Runion data for %CB versus percent gasoline remaining to the percent
VOL 17/NO 4, OCT/DEC 2011 www.ijoeh.com
Estimating Dermal Benzene Absorption 289
TABLE 1 The Percent Benzene (vol/vol) in Liquid Gasoline Over Time Subsequent to the Start of Gasoline Evaporation*
Percent Gasoline Remaining
Percent Benzene (vol/vol) in
Remaining Gasoline
Time (min) at 25 C
Time (min) at 32 C
100 5.18 90 5.18 80 5.18 70 5.18 60 5.1 55 5 50 4.5 45 3.8 40 3 35 1.8 30 1 25 0.3 20 0
0 2.2 4.9 8.7 14 17.8 22 29.5 38.4 49.7 63.5 80.2 100.6
0 1.8 4.8 6.9 11.2 14.2 18.2 23.5 30.6 39.6 50.7 63.8 80.1
*The gasoline and benzene percentages were taken from Figure 5 of Runion.13 The times at 25 C and at 32 C were estimated based on equations 6, and 7, respectively.
of the initial benzene content (vol/vol), denoted %CB,0, versus time. Table 1 shows the pertinent data taken from Figure 5 in the Runion paper. For each %VG,25C value, we found the corresponding time in minutes based on equation 6. Table 1 lists these times, and Figure 3 shows %CB,0 versus time at 25 oC (the open circles). %CB,0 = 100% until about nine minutes, at which point there is a decrease to %CB,0 = 0 by about 100 minutes. Finally, it was assumed that the form of Runion's %CB versus percent gasoline remaining data at 25 oC would be approximately the same at 32 oC; in turn, equation 7 was used to find the corresponding times to reach the %VG,32C values. Table 1 also lists these times, and Figure 3 shows %CB,0 versus time at 32 oC (the open diamonds). %CB,0 = 100% until about seven minutes, at which point there is a decrease to %CB,0 = 0 by about 80 minutes. The dashed-line curve is a fourth-order polynomial fit to the benzene concentration data at 32 oC. It is described by the following equation:
Eq. 8: %CB(t) = %CB,0 [1.63 105 t4 + 2.72
103 t3 0.13 t2 0.0715 t + 110.8]
It would be informative to compare the benzene-ingasoline %CB(t) function to the %CB(t) function for benzene in other hydrocarbon liquids. However, with two exceptions, published %CB(t) data for other hydrocarbons could not be found. The exceptions involve benzene in a mineral spirits solvent used in commercial parts washers and direct/indirect data concerning benzene-in-air concentrations and benzene in crude oil on water. In the first case, manufacturer data indicated that over a 221-minute parts-washer use period at a room temperature of about 25 oC, an initial benzene concentration of 0.012% vol/vol decreased with firstorder rate constant = 0.0022 min1.17
In the second case, the benzene-in-air concentration above a contained pool of Louisiana crude oil on ocean water in the Gulf of Mexico was monitored at different times over a 387-minute period, during which the benzene concentration decreased from 90 ppm to 8 ppm; the concentration of the benzene in the same crude oil decreased from 996 ppm to less than 200 ppm over a 455-minute period.18 The temperature of the air varied from 25.9 C (78.6 F) to 28.2 C (82.8 F) and the temperature of the crude oil varied from 27.3 C (81.2 F) to 51.2 C (124.3 F). The values of the benzene in the crude oil and benzene in the air above the crude oil, expressed as fractions of the respective initial concentrations, are shown in Figure 4; the ending value for the benzene in crude oil was set at 100 ppm, which was one-half the reported limit of detection. The benzenein-air concentration time series was well described as a double exponential (biphasic) process with an early first-order rate constant 1 = 0.022 min1, and a subsequent first-order rate constant 2 = 0.002 min1, for which the fitted equation was as follows:
Eq. 9: CB,AIR(t) = (90 ppm) [0.65 exp(0.022 t) + 0.35 exp(0.002 t)]
The dashed line in Figure 4 shows the fit of equation 9 to the normalized benzene-in-air concentration data. Based on the assumption that the instantaneous benzene-in-air concentration above the outdoor spill was proportional to the corresponding benzene concentration in the crude oil, an approximation of %CB(t) in evaporating crude oil is as follows:
Eq. 10: %CB(t) %CB,0 [0.65 exp(0.022 t) + 0.35 exp(0.002 t)]
where %CB,0 is the initial percent benzene content of the crude oil.
290 Petty et al.
www.ijoeh.com INT J OCCUP ENVIRON HEALTH
Figure 3--The percent of the initial benzene content (vol/vol) in gasoline over time as the gasoline evaporates at 25 C (the open circles) versus 32 C (the open diamonds); the dashed-line curve shows the fit of equation 8 to the data at 32 C.
Figure 4--The concentration of benzene in air above a crude oil spill (open circles) and the concentration of benzene in the crude oil (open diamonds), normalized to the respective starting concentrations, over time in minutes from the start of the spill; the dashed-line curve shows the fit of equation 9 to the benzene-in-air data.
Whereas for the evaporation of benzene in gasoline there is an initial phase of no decrease followed by a curvilinear decrease to 0% in about 90 minutes (at 25 oC), for benzene in parts washer mineral spirits the decrease is a first-order rate at 0.22% per minute, and for benzene in crude oil the decrease is biphasic with an early first-order rate at 2.2% per minute and a later first-order rate at 0.2% per minute. While an explanation is not offered for these substantial differences, the following two observations are offered: The time course of benzene evaporation from a hydrocarbon mixture appears to depend on the specific mixture; if one were to naively use the benzene-in-gasoline or benzene-in-crude-oil %CB(t) functions to describe the benzene loss from mineral spirits, one would substantially underestimate the benzene concentration in the mineral spirits over time.
DERMAL FLUX FOR OCCLUDED SKIN
Published Flux Data
To estimate the dermally absorbed dose through occluded skin for a given %CB value, benzene flux (mg/cm2-hr) must be quantified. Data available from the relatively small number of published in vivo and in vitro studies are summarized in Table 2. Other than for the three studies with pure benzene, the Table 2 flux values are not normalized to 100% benzene content. The basis for the listed flux values are provided in Appendix I. The data in these studies have been
presented in various forms and units. For ease of interpretation, it would be best if future work were to use the same set of variables and units, preferably mg/cm2-hr.
Of two in vivo studies, the most relevant was that of Hanke et al.19 who measured the flux of pure benzene on the forearms of human volunteers. Of six in vitro studies, four involved human skin and used either the stratum corneum layer or a skin with the fatty layer removed (also termed partial or split-thickness skin) or full-thickness skin. The only human partial-thickness skin study was that of Blank and McAuliffe,20 who measured Kp (or Flux = Kp CB) by exposing the skin to neat benzene and to benzene at 5% vol/vol in isooctane, hexadecane, hexane, and gasoline. Partialthickness skin in vitro (200 to 400 m thick) is believed to best mimic dermal absorption in vivo,21 because fullthickness skin in vitro contains a nonfunctional capillary bed, which acts as an additional diffusion barrier. Note that Hui et al.22 used a relatively thick partialthickness skin (500 m). Both Franz23 and Blank and McAuliffe20 argued that human split-thickness skin in vitro is a good model of human in vivo dermal absorption of benzene.
Figure 5 is a log-log plot of the Table 2 flux values versus %CB, which follows from the method of Brenner.3 Note that at similar %CB values, the flux through full-thickness skin in vitro is substantially lower than through partial-thickness skin in vitro and through skin in vivo. Again, this result is expected due to the added diffusion barrier of the nonfunctional capillary bed of full-thickness skin in vitro.
VOL 17/NO 4, OCT/DEC 2011 www.ijoeh.com
Estimating Dermal Benzene Absorption 291
TABLE 2 Published Benzene Dermal Flux Data for Occluded Skin
Reference
Liquid
Skin (thickness)
Benzene
Flux
Conc. % mg/cm2/hr
Hanke et al.19 Maibach et al.10 Blank and McAuliffe20
Tsuruta30,32 Franz23,32 Loden33 Blank and McAuliffe20
Blank and McAuliffe20
Blank and McAuliffe20
Blank and McAuliffe20
Blank and McAuliffe20
Susten et al.31 Adami et al.29 Adami et al.29 Adami et al.29 Maibach et al.10 Hui et al.22
Pure Benzene Pure Benzene Pure Benzene
Pure Benzene Pure Benzene Pure Benzene Pure Benzene
Gasoline
Hexadecane
Hexane
Iso-octane
Naphtha Distillate Gasoline Gasoline Gasoline Rubber Solvent Mineral Spirits
Human/Forearm (in vivo) Monkey/Forearm (in vivo) Human/Abdomen (partialstratum
corneum, in vitro) Rat/Abdomen (partial, in vitro) Human/Abdomen (split, in vitro) Human/Breast (full, in vitro) Human/Abdomen (partialstratum
corneum, in vitro) Human/Abdomen (partialstratum
corneum, in vitro) Human/Abdomen (partialstratum
corneum, in vitro) Human/Abdomen (partialstratum
corneum, in vitro) Human/Abdomen (partialstratum
corneum, in vitro) Mouse/Back (in vivo) Human/Abdomen (full, in vitro) Human/Abdomen (full, in vitro) Human/Abdomen (full, in vitro) Monkey/Forearm (N/A/in vitro) Human/Abdomen & Thigh (500 m
partial, in vitro)
100 100
100 100 100 100
100
5
5
5
5 0.5 1.06 0.74 0.39 0.35
10*
0.4 0.23
1.85 0.19 0.25 0.099
0.66
0.062
0.041
0.105
0.164 0.012 0.00147 0.00271 0.0018 0.0062
--**
*The study protocol indicates that 100 L of radio-labeled benzene was added to 900 L of a mineral spirits cleaning product. **The skin permeation test cell configuration was such that benzene in the solvent placed on the skin was permitted to evaporate into the headspace of the test cell. Thus, the actual benzene concentration or radioactive benzene mass that remained on the skin is not known (see Discussion section).
Benzene Flux versus Concentration
Using only the in vivo and partial-thickness in vitro data from Table 2, we fit a least-squares line of the logarithm of benzene flux versus the logarithm of %CB. The linear fit is in Figure 5. Exponentiating the log-log line yields the following power function on the arithmetic scale:
Eq. 11: Flux, mg/cm2-hr = 0.0204 (%CB)0.6616
The power curve fits the data well and updates the work by Brenner et al.3 Figure 6 uses arithmetic axes to show the equation 11 power curve and the data points on which it is based. The correlation coefficient r2 = 0.950. Given the high r2 value, it is reasonable (and unsurprising) to conclude that the benzene flux is strongly dependent on the %CB value in the hydrocarbon liquid. In addition, the supralinear nature of the power function signifies that the benzene flux at %CB 5% would be underestimated if flux was based on the strictly proportionate relationship: (%CB 100%) (flux of pure benzene).
At the same time, the proportionate relationship provides a conservative "lower-bound" point estimate of the benzene flux; the italics signify that the lower bound does not correspond to a statistical confidence limit. If one chooses to make a proportionate estimate and thereby forego relying on the entire data set, the
pure benzene flux value should be the Hanke estimate of 0.4 mg/cm2-hr, the only flux value based on human subject experiments for occluded skin. Thus, the "lower-bound" estimate is:
Eq. 12: "Lower-bound" flux estimate = __%__C_B_ 100%
0.4 mg/cm2-hr
As a technical note, Appendix II provides the derivation of a statistical two-sided 95% confidence interval for the Hanke19 flux estimate. That interval is: 0.15 mg/cm2-hr, 0.63 mg/cm2-hr.
EQUIVALENT DERMAL FLUX FOR NONOCCLUDED SKIN
There are two published studies in which a known amount of radio-labeled benzene was applied to the nonoccluded skin of human subjects and the absorbed dose of radio-labeled benzene was measured. In the first study, 0.4 cm3 benzene was applied to 80 cm2 of forearm skin on each of four subjects; it was reported that the benzene completely evaporated within 30 seconds and that 0.05% of the benzene was absorbed, on average.23 In the second study, 0.1 cm3 benzene was applied to 4 square inches (25.8 cm2) of palm skin on
292 Petty et al.
www.ijoeh.com INT J OCCUP ENVIRON HEALTH
Figure 5--Benzene dermal flux on occluded skin versus % vol/vol benzene in the hydrocarbon liquid;circle symbols = in vivo and in vitro partial-thickness skin; diamond symbols = full-thickness skin.
Figure 6--Benzene dermal flux on occluded skin versus % vol/vol benzene in the hydrocarbon liquid; in vivo and in vitro partial thickness skin data.
four subjects and to 4 square inches of forearm skin on
four subjects; it was reported that, on average, 0.13% of
the benzene on the palm and 0.07% of the benzene on the forearm, was absorbed.9 The time to evaporation in
the latter study was not stated. However, given that the
nominal initial benzene film thickness in the second study (0.1 cm3 25.8 cm2 = 0.004 cm) was less than in the first study (0.4 cm3 80 cm2 = 0.005 cm), it is rea-
sonable to conclude that benzene also completely evap-
orated within 30 seconds in the second study.
The benzene mass absorbed by the nonoccluded
skin can be expressed as an equivalent benzene flux by
dividing the absorbed mass by the product of the
exposed skin surface area and exposure duration. The density of liquid benzene is 880 mg/cm3. It was
assumed in each study that skin contact with benzene
liquid lasted 30 seconds (0.00833 hr). For the Franz study,23 the equivalent flux for the forearm is: (0.0005 0.4 880 mg) (80 cm2 0.00833 hr) = 0.26 mg/cm2. For the Modjtahedi and Maibach study,9 the equivalent flux for the forearm is: (0.0007 0.1 880 mg) (25.8 cm2 0.00833 hr) = 0.29 mg/cm2-hr; the equivalent flux for the palm is: (0.0013 0.1 880 mg) (25.8 cm2 0.00833 hr) = 0.53 mg/cm2-hr.
These equivalent flux values bracket the equation 11 flux estimate of 0.43 mg/cm2-hr, and the Hanke flux estimate of 0.4 mg/cm2-hr, for pure benzene.
Maibach and Anjo10 performed similar in vivo experiments on Rhesus monkeys, and Franz23 performed
similar experiments on Rhesus monkeys and mini-pigs. Maibach and Anjo10 applied 0.05 cm3 radio-labeled benzene to approximately 12.9 cm2 of forearm skin on
three monkeys; on average, 0.172% of the applied ben-
zene mass was absorbed. The time to evaporation was
not stated, but given the nominal initial benzene film
thickness of 0.004 cm, it is reasonable to conclude that
the benzene completely evaporated within 30 seconds. The equivalent flux is: (0.00172 0.05 880 mg) (12.9 cm2 0.00833 hr) = 0.70 mg/cm2-hr. Franz23 applied 0.5 cm3 radio-labeled benzene to approximately 65 cm2 of back skin on each of six monkeys and
two pigs; it was reported that the benzene completely
evaporated within 30 seconds. The average benzene
absorbed by the monkeys and by the pigs was, respec-
tively, 0.14% and 0.09% of the applied mass. The equivalent flux for the monkey is: (0.0014 0.5 880 mg) (65 cm2 0.00833 hr) = 1.14 mg/cm2. The equivalent flux for the pig is: (0.0009 0.5 880 mg) (65 cm2 0.00833 hr) = 0.73 mg/cm2-hr.
ESTIMATING ABSORBED DOSE WITH A DECREASING BENZENE CONCENTRATION
When the benzene concentration in the liquid contact-
ing the skin decreases during the exposure period,
FluxTWA can be approximated by the product Kp CB,TWA and, in turn, used to estimate the absorbed dose. However, if one relies on equation 11 to describe ben-
zene flux as a function of the benzene concentration in
a hydrocarbon liquid, FluxTWA is more exactly computed as follows:
Eq. 13:
FluxTWA,
mg/cm2-hr
=
__1_ ET
ET
0.0204
0
[%CB(t)]0.6616 dt
As seen in Figure 3, the %CB(t) function for benzene in gasoline at 32 oC can reasonably be described in the fol-
VOL 17/NO 4, OCT/DEC 2011 www.ijoeh.com
Estimating Dermal Benzene Absorption 293
TABLE 3 Skin Factors Used to Calculate a Dermally Absorbed Dose
Skin Area
Area, cm2
Fabs
Fingertips (2 hands) Fingers (2 hands) Palms 2 Hands 2 Wrists 2 Arms (including hands) 2 Arms (not including hands) 2 Forearms--without wrists 2 Forearms--with wrists Head Neck Face Torso (including neck) Front of torso Front of chest 2 Legs Front of 2 legs 2 Thighs Back of 2 thighs 2 Lower legs
90.5 362 354 1,070 365 3,176 2,106 1,095 1,460 1,360 408 680 8,200 4,100 2,050 6,860 3,430 4,113 2,056.5 2,710
1 1 2 1.5 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Reference/Notes
Fingers/4 D=1.6M cm, L=7.2 cm (Hands-Fingers)/2 2009 Handbook* Forearms/4 2009 Handbook* Arms with hands - hands Forearms--wrists 2009 Handbook--including wrists* 2009 Handbook* 3/5 Face (Brenner, 1998)** Head/2 2009 Handbook* Torso/2 Torso/4 2009 Handbook* Legs/2 2009 Handbook* Thighs/2 2009 Handbook*
*EPA Exposure Factors Handbook (2009), Table 711 50 percentile male; other tables available for an average female or children. **Brenner et al.3; see also Keil33 for data on skin areas.
lowing two phases: For times in the interval [0, 0.12
hr], %CB(t) = %CB,0, the initial benzene concentration in the gasoline, the FluxTWA = 0.0204 (%CB,0)0.6616 mg/cm2-hr; for times in the interval [t1 = 0.12 hr, t2 = 1.33 hr], %CB(t) is given by equation 8, which is a curvilinear relationship. For the latter phase, the equation
13 integrand has to be numerically averaged over the
appropriate time interval.
In contrast, if the loss of benzene from mineral spir-
its at 32 oC is described by the exponentially decreasing
function %CB(t) = %CB,0 exp( t), equation 13
yields:
Eq. 14:
FluxTWA,
mg/cm2-hr
=
__1_ ET
ET
0.0204
0
[%CB,0 esp( t)]0.6616 dt
= _0_._0_2_0_4___(_%__C__B,_0)_0_.6_6_16_ 0.6616 ET
[1 exp(0.6616 ET)]
SKIN AREA AND THE SKIN ABSORPTION FACTOR
The surface area, SA, and skin absorption factors, FAabs, for different body areas of interest are provided in Table 3. The total area of the ten fingers (including the thumbs) can be estimated by multiplying the area of an average finger by 10. The average finger was represented as a right circular cylinder with a diameter of 1.6 cm (5/8 inch) and a length of 7.2 cm (2.8 inches). Therefore, the average finger area is approximately
36.2 cm2 ( 1.6 cm 7.2 cm), and the total finger area is 362 cm2.
The skin absorption factor of 2 for the palms relevant to forearm skin was obtained from Maibach and Anjo10 and Modjtahedi and Maibach.9 For the skin on the
hands overall, Fabs = 1.33 is the surface-area-weightedaverage of Fabs for the palms and Fabs for the fingers and the back of the hands: [2 (362/1070)] + [1
(708/1070)] = 1.33. The skin on other body areas, for
example, the scrotal skin, can have a higher Fabs value. To simplify the dermal dose calculations, an effec-
tive surface area, SAeff, can be used based on the fraction of time that different body areas are wet during a
specific activity involving dermal exposure. This effec-
tive surface area is computed as follows:
n
Eq. 15:
SAeff
=
i=1
SAi
FAabs,i
where n is the number of body areas exposed, SAi is the surface area of the ith body area and FAabs,i is the skin absorption factor for the ith body area. In turn, given
SAeff, FluxTWA and exposure duration, one can calculate the dermal dose in mg.
EQUIVALENT INHALATION DOSE DUE TO DERMAL ABSORPTION
To convert a dermally absorbed benzene dose in mg to an equivalent occupational inhalation exposure in ppmyears, the mass of benzene absorbed by inhaling one ppm benzene over one work year is estimated. One ppm benzene-in-air corresponds to 3.19 mg/m3 at normal
294 Petty et al.
www.ijoeh.com INT J OCCUP ENVIRON HEALTH
pressure and temperature conditions. The standard breathing rate at work is assumed to be 1.2 m3/hr, as pertains to an average adult male performing moderate activity.24 We assume a pulmonary benzene absorption factor of 0.5.25 We assume that the standard work year consists of eight hours a day, for five days a week, for 48 calendar weeks; the remaining four calendar weeks are attributed to holidays, vacation leave, and sick time. Thus, we assume 1,920 work hours in a work year. If the average benzene concentration in inhaled air is 3.19 mg/m3, the exposed individual absorbs 3,675 mg in a work year, or: (3.19 mg/m3) (1.2 m3/hr) (1,920 hr) 0.5. Thus, one ppm-year of occupational benzene inhalation exposure corresponds to absorbing 3,675 mg benzene. In turn, dividing the dermally absorbed benzene dose by 3,675 mg provides the equivalent occupational benzene inhalation exposure in ppm-years.
EXAMPLE DERMAL DOSE CALCULATIONS
To illustrate the dermal dose calculations, a scenario with two different versions is posed. In the scenario, a worker cleaned oily parts with a benzene-containing hydrocarbon solvent by immersing both hands in a container of fresh solvent six times a day for two minutes; the solvent temperature was 25 oC. After the hands were removed from the solvent, the worker did not dry the wet skin until two minutes later. This same daily regimen occurred for 240 work days per year for 30 calendar years, such that there were n = 43,200 dermal exposure events: (6 events/day) (240 days/yr) (30 yr). The wetted hand surface area was 1,070 cm2. In the first version of the scenario, the solvent was gasoline containing benzene at 2% vol/vol. In the second version, the solvent was a less volatile hydrocarbon containing benzene at 0.1% vol/vol.
Gasoline
During the two minutes of immersing the hands in gasoline and the subsequent two minutes before the hands were dried, Figure 2 indicates that the benzene concentration in the gasoline would be the same as the initial concentration. According to the equation 11 power function:
Benzene Flux = 0.0204 (2%)0.6616 = 0.0323 mg/cm2-hr
Thus, the dermally absorbed benzene mass per fourminute exposure event is:
DAnoevap = (0.0323 mg/cm2-hr) (1,070 cm2) 1.33 (0.0667 hr) = 3.07 mg
Given 43,200 dermal exposure events, the total dermally absorbed benzene mass is 132,624 mg, or (3.07
mg/event) (43,200 events). The equivalent occupational benzene inhalation exposure due to dermal absorption is 36.1 ppm-years, or (132,624 mg) (3,675 mg/ppm-year). The 3.07 mg benzene absorbed in four minutes can also be expressed as an equivalent fourminute TWA inhalation exposure level of 24 ppm. That is, inhaling 24 ppm benzene (76.7 mg/m3 at NTP conditions) for four minutes (0.0667 hr) at a breathing rate of 1.2 m3/hr leads to absorbing 3.07 mg benzene, or: (76.7 mg/m3) (1.2 m3/hr) (0.0667 hr) 0.5. In turn, six four-minute exposures to 24 ppm benzene in an eight-hour shift, with no other benzene exposure, leads to an equivalent eight-hour TWA benzene inhalation exposure of 1.2 ppm, or: (24 ppm) (24 min 480 min).
In the gasoline scenario, the post-cleaning exposure time was limited to two minutes by assuming the worker did not dry his hands until two minutes after the cleaning task. It has been observed that gasoline should evaporate from skin in about five minutes.26 However, post-activity dermal exposure to a volatile chemical can continue for a substantially longer time if the hands are not purposely dried or cleaned. For example, Franz23 reported that when benzene was put on nonoccluded human skin in vitro at a volume density of 0.12 cm3 per cm2 (an initial film thickness of 0.12 cm), complete evaporation from the skin took approximately 45 minutes; during the experiment, the outer layer of the skin was exposed to room air at 21 oC, while the under layer of the skin was bathed in fluid at 37 oC. Franz also observed that greater initial volume densities of benzene on the skin led to longer evaporation times, and that the total benzene mass absorbed was proportional to the evaporation (exposure) time. In addition, for less-volatile benzene-containing hydrocarbon mixtures such as crude oil and penetrants, the evaporation halftime of the bulk liquid is on the order of hours, not minutes, which would likely result in longer dermal contact with benzene if the skin was not cleaned. Finally, repeated dermal contact with gasoline would overtly damage the skin, such that the benzene flux through the skin would be approximately fivefold greater than assumed in this example.
We note that Kalnas and Teitelbaum2 discussed a similar exposure scenario for automotive mechanics who had frequent skin contact with gasoline containing benzene at 2% vol/vol while cleaning parts and their hands for episodes lasting one to two minutes. Those authors estimated that as a daily average, a mechanic had 32 minutes of gasoline contact with 500 cm2 of damaged skin on the palms, and 16 minutes of gasoline contact with 500 cm2 of nondamaged skin on the dorsal surface of the hands. It was estimated that 20 years of that regimen led to 104 ppm-years of equivalent benzene inhalation exposure; the exact number of work days per year was not specified. The estimate relied on a set of values offered by Susten, et al.27: The flux of pure benzene
VOL 17/NO 4, OCT/DEC 2011 www.ijoeh.com
Estimating Dermal Benzene Absorption 295
through healthy skin is 3.36 mg/cm2-hr; the volumetric breathing rate is 10 m3/8-hrs or 1.25 m3/hr; and 60% of inhaled benzene is absorbed into the bloodstream. It was assumed that the benzene flux was reduced in proportion to the benzene content of the gasoline (or 0.02 3.36 mg/cm2-hr = 0.0672 mg/cm2-hr), and that damaged skin permits a fivefold greater benzene flux.
We compare the Kalnas and Teitelbaum2 estimate to that derived by our method and ppm-year metric. We assume a lower benzene flux of 0.0323 mg/cm2-hr for benzene at 2% vol/vol in gasoline. We assume Fabs = 2 for the palmar skin (362 cm2), which increases fivefold to Fabs = 10 due to skin damage. We assume Fabs = 1 for the rest of the skin on the hands (708 cm2), which is undamaged. Given the same contact duration per day, we estimate the daily absorbed benzene dose at 68.5 mg:
Daily dose = (0.0323 mg/cm2-hr) [(362 cm2)
10 (32/60 hr) + (708 cm2) 1
(16/60 hr)] = 68.5 mg
For this example, we assume the number of work days per year is 240 days, or 4,800 days over 20 years. Thus, we estimate the cumulative benzene mass absorbed to be: 68.5 mg/day 4,800 days = 328,800 mg. Dividing by 3,675 mg benzene per ppm-year yields 89.5 ppmyears of equivalent inhalation exposure, which is 14% lower than the 104 ppm-years estimated by Kalnas and Teitelbaum.2 We do not consider a 14% difference to be substantial despite the differences in the flux values used, and the uncertainty regarding the number of exposure days assumed by Kalnas and Teitelbaum.2
A Less-volatile Solvent
In this scenario, we assume that the benzene concentration in the solvent in the container is relatively constant, but the benzene concentration in the solvent on the hands exponentially decreases with a first-order rate constant = 2 hr1 (a half time of about 20 minutes). Based on the equation 11 power function, the benzene flux is 0.00445 mg/cm2-hr for benzene at 0.1% vol/vol. The dermally absorbed benzene mass in the first two minutes (0.0333 hr) is:
DAnoevap = (0.00445 mg/cm2-hr) (1,070 cm2) 1.33 (0.0333 hr) = 0.211 mg
During the two-minute post-cleaning, %CB(t) in the solvent on the skin is exponentially decreasing with = 2 hr1. Based on equation 14:
FluxTWA
=
_0_._0_2_0_4_3__(_0_.1_%__)_0_.6_61_6_ 0.6616 2 0.0333
[1 exp(0.6616 2 0.0333)]
= 0.00435 mg/cm2-hr
The dermally absorbed benzene mass in the second two minutes is:
DAevap = (0.00435 mg/cm2-hr) (1,070 cm2) 1.33 (0.0333 hr) = 0.206 mg
There is little difference in the DAnoevap and DAevap values because the loss constant = 2 hr1 results in very little benzene loss in a two-minute period. Adding DAnoevap and DAevap yields 0.42 mg benzene absorbed per four-minute exposure event. Given 43,200 dermal exposure events, the total dermally absorbed benzene mass is 18,144 mg, which corresponds to 4.9 ppm-years of equivalent occupational benzene inhalation exposure. Again, repeated dermal contact with a hydrocarbon solvent would overtly damage the skin, such that the benzene flux through the skin would be approximately fivefold greater than assumed in this example.
DISCUSSION
Available information on dermal exposures to benzene and benzene-containing products has been reviewed and mathematical models have been proposed to estimate benzene dermal absorption at the time of application and post-application. A key aspect of the analysis is accounting for a decreasing benzene concentration in the liquid on the skin due to preferential benzene evaporation. As illustrated in the examples offered, the inhalation equivalent of the dermally absorbed benzene dose (both during application and post-application) can be substantial.
Because it is now considered unethical to use human subjects for in vivo dermal absorption experiments with benzene, it is likely that all future human work will use in vitro systems. In that regard, skin thickness is a critical parameter. Partial-thickness skin in vitro (200 to 400 m thick) is believed to best mimic dermal absorption in vivo. Some researchers have used full-thickness in vitro skin, which as expected, results in reduced fluxes that do not appear to mimic in vivo data. Additional human in vitro data using benzene in different solvents (e.g., gasoline, toluene, xylene, naphtha) at levels below 5% would be helpful for the purpose of exposure reconstruction. Such data would also better define a supralinear concentration-dose relationship.
After the draft of this paper was completed, we became aware of a recent article that also concerned the dermal flux of benzene in occupational settings.28 As part of their analysis, Williams et al. considered the set of benzene steady-state permeation rate (SSPR) estimates from the three in vitro human skin studies listed in Table 220,22,29 (Blank and McAuliffe; Adami et al.; Hui et al.), and concluded that the SSPR was not proportional to the benzene content of the liquid. It is true that the SSPRs reported across these three studies do not exhibit a proportionate relationship, and this
296 Petty et al.
www.ijoeh.com INT J OCCUP ENVIRON HEALTH
paper suggests that at benzene concentrations below 5%, the relationship is supralinear. However, the Williams et al.28 conclusion, based on the reported SSPR values, is unwarranted, because it is not appropriate to make a simple comparison of the data from the three studies in the first place.
The Adami et al.29 study used full-thickness skin. Williams et al.28 argued that the greater thickness due to the presence of the dermis would only delay the time at which a SSPR was observed. However, they did not account for the circumstance that the presence of the nonfunctional capillary bed in the dermis layer would increase the length of the diffusion path and thereby decrease the SSPR.
The Hui et al.22 study involved placing 10 L, or alternatively 30 L, of a mineral spirits solvent on a 500 m thick piece of skin in a sealed diffusion cell with headspace volume 1,000 L. Williams et al. described this skin as "split-thickness," but 500 m is somewhat thicker than the 200 to 400 m range used by Roberts and Walters21 to describe split-thickness skin.28 More importantly, the relatively large volume of headspace air above the skin in the diffusion cell (30- to 100-fold greater than the solvent volume applied) permitted benzene evaporation from the solvent into the headspace, which thereby decreased the nominal benzene concentration in the solvent on the skin. Because Hui et al. did not measure how much benzene evaporated into the headspace air, the actual benzene concentration in the solvent on the skin is unknown.22
Both the Adami et al.29 and Hui et al.22 studies were deficient in another important aspect; they lacked an internal control experiment in which the skin was challenged with neat benzene. Because the reported neat benzene SSPR differs between in vitro studies that used different permeation systems, the proper comparison standard for evaluating whether a given benzene SSPR value (for benzene in a hydrocarbon mixture) exhibits proportionality is the SSPR for pure benzene in the same system. The only human skin in vitro study that included this internal comparison standard was the Blank and McAuliffe study.20 The latter investigators observed that the benzene SSPR from mixtures of benzene at 5% vol/vol in four hydrocarbons (hexadecane, gasoline, hexane, and iso-octane) was greater than proportionate compared to the SSPR of neat benzene.
Williams et al.28 questioned the reliability of the Blank and McAuliffe20 study. They appeared to argue that the well-hydrated skin in the study protocol and/or the solvents in which the benzene was present enhanced the permeation of benzene. With regard to hydration, the study itself suggested no effect of hydration on benzene permeation. Figure 2 of the Blank and McAuliffe20 paper showed no significant difference in the permeation coefficient (Kp) of benzene when neat benzene was placed on skin that did or did
not have three hours of prior contact with a 0.1% NaCl solution. With regard to the enhanced permeation of benzene from some hydrocarbons compared to permeation from neat benzene, Blank and McAuliffe20 reported higher mean normalized permeation coefficients for benzene in hexadecane, gasoline, hexane, and iso-octane compared to permeation from neat benzene. The mean value for neat benzene was 6.4 104 cm/hr compared to 9.4 104, 14 104, 24 104, and 37 104 cm/hr for the four hydrocarbons, respectively. However, there is nothing inherently suspicious about benzene showing a higher Kp value in various liquids compared to neat benzene. For example, for benzene in water, the reported Kp value was 1,110 104 cm/hr.
CONCLUSIONS
The method presented in this paper for determining dermal uptake of benzene from benzene-containing hydrocarbon liquids is more comprehensive than methods currently used in industrial hygiene. The power curve for benzene flux through occluded skin as a function of the vol/vol percent benzene in the liquid is based on the complete set of pertinent published data. In addition, the method accounts for a possible dynamic decrease in flux during an exposure period due to an evaporative decrease in the benzene concentration in the liquid contacting the skin. The available data on dermal uptake of benzene on nonoccluded skin are consistent with this model for occluded skin.
References
1. Fiserova-Bergerova V. Relevance of occupational skin exposure. Ann Occup Hyg. 1993;37(6):67385.
2. Kalnas J, Teitelbaum DT. Dermal Absorption of Benzene: Implications for Work Practices and Regulations. Int J Occup Environ Health. 2000 Apr-June;6(2):11421.
3. Brenner D, Kalnas J, Teitelbaum DT. Skin Absorption of Benzene as a Contaminant in Other Solvents. Eur. J. Oncology. 1998;3(4):399405.
4. Mulhausen J, Damiano J. 1998. A Strategy for Assessing and Managing Occupational Exposures, 2nd edition. Fairfax (VA). American Industrial Hygiene Association (AIHA) Press; c1998. p. 349.
5. Ignacio JS, Bullock WH. A Strategy for Assessing and Managing Occupational Exposures. 3rd ed. Fairfax(VA): American Industrial Hygiene Association (AIHA) Press; c2006. p. 323324.
6. Occupational Safety and Health Administration. Occupational Exposure to Benzene. Fed Regist. 1987 Sept 11;52(176): 3448790.
7. Chin JY, Batterman SA. Permeation of Gasoline, Diesel, Bioethanol (E-85), and Biodiesel (B20) Fuels Through Six Glove Materials. J of Occup and Environ Hyg. 2010;7(7):41728.
8. U.S. Environmental Protection Agency (USEPA). Dermal Exposure Assessment: Principles and Applications. 1992. Washington (DC): Office of Health and Environmental Assessment. EPA/ 600/8-91/011B.
9. Modjtahedi BS, Maibach HI. In Vivo Percutaneous Absorption of Benzene in Man: Forearm and Palm. Food and Chemical Tox. 2007;46:117174.
10. Maibach HI, Anjo D. Percutaneous Penetration of Benzene and Benzene Contained Solvents Used in the Rubber Industry. Archives of Env Health. 1981;36(5):25660.
VOL 17/NO 4, OCT/DEC 2011 www.ijoeh.com
Estimating Dermal Benzene Absorption 297
11 Fingas MF. Studies on the Evaporation of Crude Oil and Petroleum Products II. Boundary Layer Regulation. J of Haz Mat. 1998;57:4158.
12 Rubek DD, Dahl GW. An Evaporation Rate Method Applied to Petroleum Thinners. Ind & Eng Chem An Ed. 1934;6:42122.
13. Runion HE. Benzene in Gasoline. J Amer Ind Hyg Assoc. 1975 May; 33850.
14 Kokubo H, Taniguchi J, Yamamoto M, Hirasawa M. Categorization with Temperature Distribution of the Human Hand Surface. J Intl Soc Life Info Sci. 1998;16:24754.
15. Montgomery LD, Williams BA. Effect of Ambient Temperature on the Thermal Profile of the Human Forearm, Hand, and Fingers. Annals of Biomedical Eng. 1976;4:20919.
16. U.S. Environmental Protection Agency (USEPA). Compilation of Air Pollutant Emission Factors. 5th ed. Vol. 1. Stationary Point and Area Sources. AP42.
17. Nicas M, Plisko MJ, Spencer JW. Estimating Benzene Exposure at a Solvent Parts Washer. J Occup & Envir Hyg. 2006;3:28491.
18. Jones RK, Farr J, Simecek-Beatty D, Carney K, Roques D, Henry C, Overton E. The Evaporation of Benzene and a Series of Alkanes from Crude Oil. Seattle (WA): NOAA/Hazardous Materials Response and Assessment Division: 1992. 4p. Report No.: HMRAD.
19. Hanke J, Dubiewicz T, Piotrowski J. The Absorption of Benzene Through the Skin of Man. Med Pr. 1961;12:41325.
20. Blank IH, McAuliffe DJ. Penetration of Benzene Through Human Skin. J. Invest. Dermatol. 1985;85:52226.
21. Roberts M, Walters K, editors. Dermal Absorption and Toxicity Assessment. 2nd edition. New York (NY). Marcel Dekker, Inc.; c1998. p. 785.
22. Hui X, Wester RC, Barbadillo S, Cashmore A, Maibach HI. In Vitro Percutaneous Absorption of Benzene in Human Skin. Cutaneous and Ocular Toxicology. 28(2):6570.
23. Franz TJ. Advances in Modern Environmental Toxicology, Applied Toxicology of Petroleum Hydrocarbons. Vol. 6, Percutaneous Absorption of Benzene. Princeton (NJ): Princeton Sciences; 1984.
24. U.S. Environmental Protection Agency (USEPA). Exposure Fac-
tors Handbook. June 1995. EPA/600/P-95/002A. 25. Agency for Toxic Substances and Disease Registry. ATSDR Tox-
icological Profiles. Benzene. CRC Press, Inc.; c1997. p. 292. 26. Swanson, John W. (American Petroleum Institute). Memo to:
Thomas R. Scovel (Texaco, Inc.). 1982 March 18. Percutaneous absorption of benzene from gasoline. 27. Susten, AS, Niemeier RW, Simon SD. In Vivo Percutaneous Absorption Studies of Volatile Organic Solvents in Hairless Mice II. Toluene, Ethylbenzene and Aniline. J of Applied Toxic. 1990; 10(3):21735. 28. Williams, R.D., Sahmel J, Knutsen J, Spencer J, Bunge AL. Dermal Absorption of Benzene in Occupational Settings: Estimating Flux and Applications for Risk Assessment. Critical Reviews in Toxicology. 2011;41(2):11142. 29. Adami G, Larese F, M Venier M, Barbier P, LoCoco F, Reisenhofer E. Penetration of Benzene, Toluene, and Xylenes contained in Gasoline through Human Abdominal Skin in vitro. Toxicology in Vitro. 2006;20(8):132130. 30. Tsuruta H. Percutaneous Absorption of Organic Solvents III: On the Penetration Rates of Hydrophobic Solvents through the Excised Rat Skin. Ind Health. 1982;20:33545. 31. Susten, AS, Dames BL, Burg JR, Niemeier RW. Percutaneous Penetration of Benzene in Hairless Mice: An Estimate of Dermal Absorption During Tire-Building Operations. Amer J of Ind Med. 1985; 7:32335. 32. Franz, TJ. Percutaneous Absorption of Benzene, Proceedings of the symposium...The Toxicology of Petroleum Hydrocarbons, Sponsored by the American Petroleum Institute, May 1982, 108114. 33. Loden M. The in vitro Permeability of Human Skin to Benzene, Ethylene Glycol, Formaldehyde, and n-Hexane. Acta Pharmacol Toxicol. 1986;58:38289. 32. Fiserova-Bergerova V, JT Pierce JT. Biological Monitoring V: Dermal Absorption. Applied Ind Hyg. 1989 Aug;4:F-1421. 33. Keil CB, editor. Mathematical Models for Estimating Occupational Exposures to Chemicals. Fairfax (VA) American Industrial Hygiene Association (AIHA) Press; c2000. p. 106.
298 Petty et al.
www.ijoeh.com INT J OCCUP ENVIRON HEALTH
APPENDIX I Basis for Conversion of Various Dermal Data to Flux Values
1. Tsuruta30--Neat BZ
Table 3, page 342: Penetration rate = 40.7 nmoles/ min/cm2
MW of benzene = 78.1 mg/mmole C1 = 60 min/hr. C2 = 1.00E+06 mmole/nmole Flux = Penetration rate C1 MW/C2 = 0.19 mg/
cm2/hr
2. Franz23--Neat BZ
Figure 5, page 69 Total benzene absorbed/hour = 0.28 L/cm2/hr. Slope of plot in Figure 5 Density of Benzene = 0.88 g/m (mg/) Flux = Total absorbed/hr density = 0.25 mg/cm2/hr
3. Maibach and Anjo10--Neat BZ and 0.35% BZ in rubber solvent
Only data for multiple (Nd = 10) exposures used in calculations (most like occluded case)
Table 1, page 258 %BZ = 0.35%, ABS = 0.431% rubber solvent %BZ = 100%, ABS = 0.848 % neat benzene %BZ in dosing solution = 0.35 % rubber solvent %BZ in dosing solution = 100% neat benzene Fraction of BZ in dose = FQ=%ABS/100 = 0.00350
rubber solvent Fraction of BZ in dose = FQ=%ABS/100 = 1 neat
benzene Area dosed = S = 1.29 cm2 rubber solvent Area dosed = S = 12.9 cm2 neat benzene Benzene Loading on skin = Q = 68.1 mg/cm2 rubber
solvent 6.81 mg/cm2 neat benzene; Total of 68.1 for 10 doses Number of doses = Nd = 10 both solvent & neat
Dose Absorbed = DA = S Q FQ (ABS/100) Nd = 0.01325 mg rubber solvent
Dose Absorbed = DA = S Q FQ (ABS/100) Nd = 7.45 mg neat benzene
Dosing time = ET = 1.67 hr rubber solvent; 10 10 min between doses Page 257
Dosing time = ET = 2.5 hr. neat benzene; 10 15 min between doses Page 257
Flux = DA/(S ET) = 0.0062 mg/cm2/hr rubber solvent
Flux = DA/(S ET) = 0.23 mg/cm2/hr neat benzene
4. Blank et al.20--5% BZ in various materials
Table 2, page 525 provides Kp 10^-3
Kp (5% BZ in Hexadecane) = 9.40E-04 cm/hr Kp (5% BZ in Isooctane) = 3.73E-03 cm/hr Kp (5% BZ in Hexane) = 2.40E-03 cm/hr Kp (5% BZ in gasoline) = 1.40E-03 cm/hr Concentration = Cd = 50 L/m = 50 L/cm3 Density of benzene = 0.88 mg/
Flux = Kp Cd Density
Flux (5% BZ in Hexadecane) = 0.041 mg/cm2/hr Flux (5% BZ in Isooctane) = 0.164 mg/cm2/hr Flux (5% BZ in Hexane) = 0.105mg/cm2/hr Flux (5% BZ in gasoline) = 0.062 mg/cm2/hr
Pure benzene data--page 524, data from Figure 1, page 523, not used (see Kalnas and Teitelbaum2 p. 118 for details)
Steady state flux: 2.11 L/cm2/hr (average flux of eight values, std. dev. 1.8)
Density of benzene = 0.88 mg/
Flux (100% benzene) = ~1.85 mg/cm2/hr. (2.11 0.8786)
5. Susten et al.31--0.5% BZ in naphtha distillate
Table 3, page 331 Benzene mass absorbed/ unit area of skin = 0.0275
mg/cm2 Absorption time = 2.3 hr. to 10% level in Figure 2,
page 330 Flux = Amount absorbed/ET = 0.012 mg/cm2/hr
VOL 17/NO 4, OCT/DEC 2011 www.ijoeh.com
Estimating Dermal Benzene Absorption 299
APPENDIX II Construction of a Two-Sided 95% Confidence Interval on the Hanke19 Flux Estimate
Hanke et al.19 did not offer a statistical confidence interval on their 0.4 mg/cm2-hr flux estimate, but we constructed a two-sided 95% confidence interval. Study Data In the study, 0.02 mL (17.6 mg) benzene was held against 8 cm2 of forearm skin for 1.25 hour by using an inverted watch glass. The watch glass was enclosed by a suction device such that any benzene vapor escaping from the watch glass was drawn through a collection medium. At the end of the 1.25 hour, the watch glass seal was broken and the liquid benzene remaining on the skin was evaporated off by the suction device through the collection medium. The benzene mass collected was measured via a laboratory absorption assay. As a control, the same volume of benzene was held against glass (a nonabsorbing surface) for 1.25 hour. At
Figure 7--The uncertainty distribution for the Hanke pure benzene flux estimate of 0.4 mg/cm2-hr as generated by a Monte Carlo sampling method.
the end of the period, the remaining benzene was col-
lected and analyzed in the same manner.
There were n1 = 15 glass control absorption meas-
urements for_which the me_an and standard error were,
respectively, x1 = 0.49 and sx1 = 0.007. There were n2 = 7
human subject absorption measurements for w_hich the
mean_ and and sx2 =
standard error 0.027.19 Hanke
were, used
respectively, x2 the difference
= 0.38 in the
means to compute the mass of benzene absorbed via
the expression: [(0.49 0.38) 0.49] 17.6 mg = 4
mg. This mass was divided by the product of the 8 cm2
skin surface and the 1.25 hour exposure time (equal to
10 cm2-hr) to arrive at the flux point estimate 0.4
mg/cm2-hr.
Monte Carlo Method
The confidence interval was derived as follows. For
each set of measurements, the reported mean and stan-
dard error were treated as the parameters of a t-distri-
bution with n 1 degrees of freedom. We performed 5 105 iterations of a sampling experiment via a com-
puter code. For each itera_tion, one value was drawn from the t-distribution for x1, and one value _was independently drawn from the t-distribution for x2. These two values were used in Equati_on (A1) below to generate a flux value_. If the sampled x2 value was greater than the sampled x1 value, the flux was set equal to zero; approximately 0.35% of the flux values were zero.
[ ]Eq. A1: Flux =
_ 1 _x__2_
x1
__1_7_._6_m__g__ 10 cm2 hr
This sampling procedure generated a symmetrical dis-
tribution of flux estimates as shown in Figure 7. The mean is 0.4 mg/cm2-hr and the central 95% of values lie between 0.15 and 0.63 mg/cm2-hr. Thus, the twosided 95% confidence interval is [0.15 mg/cm2-hr, 0.63 mg/cm2-hr].
300 Petty et al.
www.ijoeh.com INT J OCCUP ENVIRON HEALTH