Moncrief Aristocrat and "Special" Oil Fired Winter Air Conditioners, made to operate with any standard Gun Type Burner, and Gas Fired Winter Air Con ditioners are available in numerous sizes and capacities. Write for particulars.
Oil Fired Air Conditioner "SPECIAL" OIL FIRED AIR CONDITIONERS
Unit No.
75
Input Gallons per hour................ - .76
Size of casing:
Width........................................... 28"
Depth........................................... 71"
Height...................................
>y,-
Blower size................................... no
Motor Hp..................................... 1/6
Heating surface--*q in................ 6120
915
No. filter* 13 * 25........................ 2
Btu Del. at Register.................... 75,000
100
1.02
28" 71' 603/,' 112 y. 6120 1225 2 100.000
Gas Fired A ir Conditioner Approved by American Gas Association
SIZES, CAPACITIES--Aristocrat Oil-Fired Units.
j Blower Size |
No. of Filters Size of Filters Shipping Weight (Approx.) Input Gel Per Hour
'E . Oo <j0.5H A
Casing Dimensions
Plenums
Warm Cold Air Air
B c D lE
G |H J K L M N
- 'it _3oe
CL if, 30S ' * CO 0
.
Is
. "s S'2-g
ea2
125 765/. 51% 60% 48%'28 51% 38%l% 18 20 28 20 28 125,000 1525 112 z. 8925 4 16x25 1240 1.28
150 7AVS 51% 60% 48% 28 513/. 383/45% 18 24 28 24 26 150,000 1830 114 z. 8925 4 16x25 1265 1.53
175 80% 56% 60% 52% 28 51% 43% 5% 18 74 32 24 32 175,000 22011 114
11088 4 16x25 .1365 1.8
m 275
80$ 97
6564%$
64
52%|28 51% 43% 3% 18 24 36 24 36 200.000 244e; 114 $ 59 38 51'/. 51/2 53/4 18 30 40 30 40 275,000 3350j 214 y.
11088 13248
4 6
16x25 1455 2.04 16x25 2010 2.8
SIZES, CAPACITIES--Gas-Fired C.B.F. Units.
Btu Input Btu at Register Blower Size | Motor Hp 1 No. of Filters | Filter Size Sq In. Heating
Surface Gas Line No. of Burners
Casing Dimensions
Plenum Size Inches
Warm Cold Air Air
Unit No.
A B CD EK L M N
G-8 75 70 54 13 14 32 :i6 14 80,000 57,000 no 1/6 2
0-1? 75 26 54 1 % n 19 32 22 15 120,000 85,500 112 /. 3
G-16 75 34 54 1% 12 26 34 30 12 160,000 114,000 112 z. 4
0*70 75 41 54 1% 12, 32 34 37 12 200,000 142,500 114 H 4
G-24 75 49 0-37 75 68
54 1% 12 40 54 1% 12152
34 34
44 60
12 12
240,000 320,000
171,000 228,000
114 214
Yt
5 6
0-40 75 781/, 54 Wi 12 66 34 72 12 400,000 285,000 214 % _8
G-48 75 941/2 54 in 12^80 34 88 12 480,000 342,000 214 1 9
16x25 16x25 16x25
16x25 16x25 16x25 16x25 16x25
Jj eoO
UQ |
798 1197 1596 1995 2394 3192 3990 4788
5410 8115
10820 13525 16230 21640
27050 32460
1" 1" 1" 1" r
l>4
I'/." 1'//
2 3 4 5 6
8 10
12
Henry Furnace & Foundry Air Conditioning, Automatic Heating Systems
Moncrief Aristocrat Coal-Fired Winter Air Conditioners are made with either cast or steel heating elements, in a wide range of sizes. Equipment includes metal floor, blower with motor, filters, controls, dam per motor, thermostat and Thermo-Drip Automatic Humidifier, duplex roller-bear-
ing grates--except with triangular grates, at no extra cost (on cast only). If to be used with stoker, grates and controlsLexcept blower control--may be omitted, stokers being equipped with control. Finegrain crackle finish--green, trimmed with chromium plate.
With Cast Heating Element.
Unit
Size No.
Casing Dimensions-- inches
A B c D EF
Plenum Size
Warm Cold air air
K LMN
Blower Size
Motor Hp
Sq In. Heating
Surface
Grate Area
Sq In.
Cfra Re quired
No. of Filters
Forced
Air
Register Btu
Coal
HandFired
Forced Air
Register Btu
Stoker Fired
ft4020 66/, 40/, 623/, 381/, 28 soy. 30 28 30 18
4422 68/, 42/, 623/, 38/, 30 soy. 32 28 32 20 4824 701/, 44/, 62*/, 401/, 30 503/, 34 30 34 20 5226 78/, 46/, 66 44/, 34 503/, 36 34 36 22
no 112 112
112
%
% /, X
5021 214 967 5609 269 1157 6010 326 1330 6753 397 1580
2 73,800 85,200
3 88.300 101,800 3 101.600 117,300 4 120,400 139,000
5628 82/, 48/, 66 48/, 34 503/, 38 38 38 24 114
7579 472 1840
5 140,300 162,000
With Steel Heating Element.
^Blower Size II Motor Hp Sq In. Heating Surface Grate Area Sq In. Cfm Required No. of Filters || Forced Air Register Btu Coal HandFired Forced Air Register Btu Stoker Fired
Unit Size No.
Casing Dimensions--inches A B- c b E F G
Plenum Size
Warm Cold air air
K LMN
2054 68/, 40-/, 62V, 401/, 28 503/, 35/, 30 30 30 16 no 2254 70/, 44/, 62/, 40/, 3(J soy. 39# 30 34 34 18 112 2456 74/, 46/, 66 40/, 34 soy, 41/, 30 36 36 20 112 2758 74/, 51/, 67'/, 40/, 34 soy. 46/, 30 42 42 20 114 3060 86/, 54/, 69 48/, 38 soy. 49/, 36 42 42 24 212 3060J 90/, 54/, 69 52/, 38 503/, 49/, 40 42 42 24 212 3462 90/, 60/, 71 48/, 42 soy. 55/, 36 48 48 24 214 3462J 96/2 60/, 71 54/, 42 50# 55/, 42 48 48 24 214
% % % V4 *4
'Vh,
6226 6499 6960 8086
10041 11480 11245 12386
214 269 330 434 552 552 730 730
1070 1232 1424 1815 2240 2362 2800
2895
2 81,600 94,200
3 94,000 108,400
4 108,700 125,500 5 t38,600 160,000 5 171,000 197,300 5 180.300 208.000
6 213,800 246,700
6 221,200 255,200
Heating capacities are based on a 7 lb combustion rate using 12,000 Btu coal and efficiencies of --65 per cent at bonnet, 85 per cent register for fan coal hand fired--75 per cent at bonnet, 85 per cent at register for oil or stoker fired.
If 6 lb combustion rate is desired for prolonged firing period deduct approximately 15 per cent from forced air Btu ratings. Maximum velocity through filters, 200 feet per minute.
The Anthracite Winter Air Conditioner consists of a MONCRIEF Unit and a Miles Combustion Modulator.
The outside temperature is correlated with the warm air temperature to affect a Graduated Room Temperature, 68 deg in mild weather and 78 deg in zero weather.
Constant Modulated Heat Supply eliminates COLD 70 and complicated control equipment. Write for particulars.
Note: Made with either the Moncrief Cast or Steel Aristocrat Air Conditioner.