1074 :: > a - CHAPTER 42 : ' V7 1 ; 1958?Guide complished by the addition of polyphosphate in low concentrations.11 The use of polyphosphate in the ratio of two parts by weight to one part by weight of iron is usually most effective. The polyphosphate must be added to the water before exposure of the water to air or chlorine if ef fective stabilization of the iron is to occur. Closed Recirculating Systems The closed recirculating system is one in which water circulates through one heat exchanger where it absorbs heat, has its temperature elevated, and circulates through another heat exchanger in which its temperature is lowered. In-cold water or chilled water systems scaling is seldom a problem. In hot water systems scaling is seldom a .problem uriless there is a large amount of. makeup water.12 In this case surface-active agents such as polyphosphate are used. 1 a1 .SO 7 2H2 HQS -HAT --1 tp ATM 25- iiii IOO ISO 200 2S0 300 PPM ALKALINITY AS C* Co, OF MAKE - UP WATER Fig. 5. Relation of Bleed-Off Requirement to CaC03 in Make-Up Water Open Recirculating Systems Where water from condensers and similar equipment is passed through a spray pond or cooling tower and then returned to the equipment, there is an increase in the concentration of solids because of the evaporation of some of the water into the cooling air, and, moreover, the aeration removes carbon dioxide. Both factors promote the tendency to deposit scale. The corrosive properties of the water can also be increased through the absorption of acid gases such as sulfur dioxide (S02), from the air.13 The absorption of gases from the air being processed and the concentration ol solids due to evaporation are factors in air washer operation when the air is humidified. The concentration of scale-forming minerals in open recirculated cooling water is limited by natural drift or windage loss. This is the loss of water droplets from the system. Windage losses from typical systems may be classified as follows, based on recirculating rates: Evaporative Condensers and Air Washers Mechanical Draft Cooling Towers. .......... Atmospheric Cooling Towers..................... Spray Ponds................................................. Percent of Recirculat ing Rate 0 to 0.1 0.1 to 0.3 0.3 to 1-0 1.0 to 5.0 Corrosion and Water Formed Deposits, Causes and Prevention 1075 To show the effect of concentration in a typical mechanical draft system assume: 1. Recirculating rate = 100 gpm. 2. Drift loss = 0.2 percent of recirculating rate = 0.2 gpm. 3. Evaporation rate = 1 percent of recirculating rate = 1.0 gpm. 4. Calcium bicarbonate in make-up water = 100 ppm. 5. Calcium bicarbonate in evaporated water = 0 ppm. Let K = concentration of calcium bicarbonate in recirculating water = concen tration of calcium bicarbonate in drift loss. The process of concentration in the system may be represented diagrammatically as follows: Make up = 1.2 gpm Ca(HC0,)t = 100 ppm Evap. = 1 gpm Ca(HCO,), = 0 ppm T________ Recirculating Water System K = Ca(HCO^)i cone. Drift 0.2 gpm Ca(HC0i)< -- K ppm The concentration may be obtained from the equation (Make Up) [Ca(HCO>)i cone.] = (Evap.) [Ca(HCOa)i cone.] + (Drift)[Ca(HCOi)j cone.] (1.2) (100) = (1)(0) + (0.2) (A) substituting, whence, 120 = 0 + 0.2 1C K = 600 ppm Therefore the concentration of calcium bicarbonate in the recirculating water equals 600 ppm. This far exceeds the allowable concentration of 170 ppm at which scaling will occur. To correct this situation, it is imperative to provide a continuous bleedoff or blow down from the recirculating water circuit. Typical bleed-off requirements are shown in Fig. 5. Reference to the No Treatment curve shows that a bleed-off rate of 1.2 times the evaporation rate is required when a make-up water contains 100 ppm calcium bicarbonate (or alka linity) if scale is to be prevented. Calculation by a material balance will show that the bleed-off plus drift loss will limit, the calcium bicarbonate to 171 ppm. ^ *-an be seen from Fig. 5 that very large amounts of bleed-off are re quired as a make-up water approaches or exceeds 150 ppm of alkalinity. When alkalinity exceeds 175 ppm, bleed-off alone is no longer effective. J-he use of 5 ppm or less of polyphosphate is extremely effective in reducing /ie. required bleed-off and making possible the use of make-up waters hich will not respond to bleed-off alone. Occasionally, waters are encountered which have exceptionally high of^^'ties or which develop high pH values when recirculated. The use 7 ac^ *s common in these cases to maintain pH values between ana 8. Polyphosphates are most always used when acid is required, t is very important to control acid feeding carefully to avoid serious rrosion. Automatic pH controllers are often employed for such purpose.