Document bqKy22EZOpELgw4M3vDwma3D
V
TO:
Union Carbide Agricultural Products Company,
Institute Plant
Inc.
I N D U S T R I A L H Y G I E N E SAMPLING
n*cmED
B_E-i2i%8S
Mr. F- Boggs
COPIES TO: Mr. D. A. pugaj.--
Building 303_________________________
Mr. C. E. Miller
Institute Plant_____________________
Mr, D. D. Miller
Mr. M. E. Tapp_________
WMr. L. . Youngblood
Purpose: _________ Quarterly __X____ Semiannually -------------- Annually
_________ Regulatory Agency Inspection
-------------- Other (See Comments)
Sample Date(s): August 1, 4 and 5, 1986
Sample Location: Landfill Department No.:
308
Process/Activity: Waste Disposal______________________________________________ ____________
- Contaminant: Asbestos
Exposure Limit: OSHA 0,2 fibers/cc
(TWA^);-(TWA^)
ACGIH UCC AIHA
0.2 fibers/cc
(TWA );-(TWA o
_________-(TWA ):"(TWA ) o
_________-(TWAq);-(TWAi2>
)
12 i.z
Sample Type:
X Personal
X Area
_______ Source
Surface Wipe
_______ Other (See comments)
Analytical Method: Per 29 CFR 1910.1001, Appex. A
Results:
____ See Comments
X See Attached Table
COMMENTS:
Four job positions at the Goff Mountain Landfill were monitored
for exposure to airborne asbestos fibers on the above dates.
Area
concentrations of airborne asbestos were measured too.
The monitoring
encompassed typical asbestos waste disposal, which consisted of using a front
end loader and a bulldozer to blend the material with dirt and pack it down.
The front end loader and bulldozer each were eguipped with enclosed.cabs and
air conditioning units that provided filtered, cooled air to the cabs. In
addition, the eguipment operators wore half-mask dual-cartridge dust
respirators while in the cabs.
UCC 008988
AU4003
-2
The monitoring also covered operation of the drum crusher and typical area cleanup by the laborer. Cleanup consisted of sweeping the paved area around the landfill office and removing debris from the perimeter of the land fill._ ________
Due to the hot and dry weather, "worst case" conditions existed during the survey regarding the potential for generation of airborne asbestos fiber concentrations. The monitoring and analytical procedures were performed in accordance with 29 CFR 1910.1001, including Appendix A.
The personal monitoring results for the laborer and environmental specialist job positions were all below the PEL as well as the action level (ie, one-half the PEL) for asbestos. The front end loader and bulldozer operators' exposures also were below the PEL though they did, reach the 0.1 fiber/cc action level. The area monitoring results showed that concentrations of airborne asbestos fibers greater than the PEL were generated in the immediate vicinity of the bulldozer and front end loader while t.hey were being used to blend and fill asbestos waste material. However, the extremely low concentration measured directly downwind of the disposal area at the drum crushing facility showed that the airborne asbestos fiber?:: rapidly settled and/or dissipated within the confines of the landfill.____________ ____________________
Based on the above results the following actions are required: A copy of these monitoring results must be posted ire edlately in the workplace (ie, the landfill office) where they will be accessible to all affected employees (including contract employees'* for review. The affected employees should be made aware that the resuits have been posted. (Note: this was done prior to issuance of thi s report).
UCC 008989
A04004
Because airborne asbestos fiber concentrations measured at the disposal area during blending and filling exceeded the PEL, the "face" of the landfill must be established as a regulated area as soon as possible but no later than November 17, 1986. This requires:
1. Posting of warning signs in conformance with the requirements of 29 CFR 1910.1001 (J)(l)(i) and (ii) to Identify the regulated area. ..................................................................................................................................................................
2. Prohibition of eating, drinking, smoking, application of cosmetics and tobacco and gum chewing in the regulated area.
3. Use of half-mask air-purifying respirators equipped with high efficiency filters (or better*) by anyone entering the regulated area, regardless of duration.
*Note: Powered air purifying respirators must be provided to
employees if they choose to use that type of respirator. In \
addition, employees using negative pressure respirators must
be
fit tested before entering the asbestos regulated area and they
must be fit tested every six months thereafter. Selection, use
and care of respirators must be in accordance with the
requirementsof29CFR1910.1001
12L_____________________________________'
A0400.H
Training must be provided to the front end loader and bulldozer
operators no later than October 20, 1986 and at least annually thereafter since these two lob positions were exposed to airborne
UCC 008990
4
concentrations of asbestos fibers at the action level. Training must cover the topics shown in 29 CFR 1910.1001 (J)(5).
Medical surveillance must be provided or made available to the front end loader and bulldozer operators no later than November 17, 1986 and at least annually thereafter since these two job positions were exposed to airborne concentrations of asbestos fibers at the action level. Medical surveillance must be performed in accordance with 29 CFR 1910,1001(L) .
RECOMMENDATIONS: In order to complete implementation of the above required activities, the following recommendations are made:
1Per the advice of Employee Relations Department and Medical Department supervision, Environmental Protection Department supervision should______ immediately pursue the establishment of a contract between Union Carbide and Henson Brothers, Inc, in order to provide asbestos training, medical surveillance, respirator fit testing (if necessary) and respirator training to the bulldozer and front end loader operators on a fee-for-service basis. When the contract is established, Industrial Hygiene personnel will be available to provide , the required training and fit testing, upon request.
2. Environmental
Protection
Department
supervision should
take
appropriate steps as soon as possible to insure that a sufficient
quantity of suitable respirators are on hand for the heavy equipment
operators and the Institute Plant truck drivers who must enter the
regulated area. In addition, a routine program (if one does not
..... .. ... ....
' AU400;
UCC 008991
-5
already exist) should be established with Safety Supply for the
(
1 cleaning, disinfecting, inspection and repair of the respirators. i^
3. Maintenance Area VI supervision should contact this office as soon as possible to coordinate the respirator fit testing and training that is required For Institute plant truck drivers to enter the landfill regulated area. (Note: Already underway at this time.)
i
/
4. Environmental Protection Department supervision should contact this office Cor assistance in establishing the regulated area at the landfill. (Note: Already underway at this time.)
Report Date: October 17, 1986
:Signed ZJJLCin
Bldg. 2
Room: 172 Phone
NOTE:
ALL PERSONAL SAMPLE RESULTS MUST BE DISCUSSED
WITH THE PARTICIPATING EMPLOYEE
6105
0400 "7 UCC 008992
Union Carbide Agricultural Products Company, Inc.
Institute Plant
INDUSTRIAL HYGIENE SAMPLING RESULTS
WORKPLACE LOCATION:
Landfill NAME(s) OF SAMPLER(s):
E.A. Osby & J.L. Miller
CONTAMINANT:
Asbestos REPORT DATE:
OSHA PEL: TWAq0.2 Fibers/cc,TWAt -j -
AI HA WEEL: TWAg-,TWA12 ~
October 17, 1986
ACGIH TLV: TWAg0.2 Fibers/cc,TWAi9
-
UCC GUIDELINE:
TWAg - TWA12 ~
Sample Number
Sample Date
W-4700-AA7915 W-4700-AA7923
8-1-86 8-1-86
W-4701-AA7925 W-4701-AA7932
8-4-86 8-4-86
W-4702-AA7935
8-5-86
W-4700-AA7916 W-4700-AA7924
8-1-86 8-1-86
W-4701-AA7926 W-4701-AA7933
8-4-86 8-4-86
W-4702-AA7936 W-4702-AA7940
. 8-5-86 8-5-86
Sample Description
Sample Time (min.)
Sample Results (fibers/cc)*
Front End Loader Operator
L. E. Pauley L. E. Pauley
265 125
**
L. E. Pauley L. E. Pauley
170 225
0.11 0.099 0.10
L. E. Pauley Bulldozer Operator C. E. Wheeler C. E. Wheeler
C. E. Wheeler C. E. Wheeler
C. E. Wheeler
c. E. Wheeler
375
265 120
170 225
180 195
0.068
0.051 0.17 0.09
0.Q97 0.10 0.099
0.087 0.12
0.10
UCC 008993
4 04 0 u1;\
Sample Number
Sample Date
2
Sample Description
Sample Time (min.)
Sample Results (fibers/cc)*
W-4700-AA7917
8-1-86
W-4701-AA7927
8-4-86
W-4702-AA7938
8-5-86
W-4701-AA7928 W-4701-AA7934
8-4-86 8-4-86
W-4702-AA7937
8-5-86
W-4700-AA7918
8-1-86
W-4700-AA7922
8-1-86
W-4701-AA7929
8-4-86
W-4700-AA7919 W-4 7 0 2-AA7 939
8-1-86 8-5-86
Senior Enviromental Specialist
J. R. Fizer
375
J. R. Fizer
395
J. P. Monroe
205
Teague Laborer
R. L. Barker R. L. Barker
303 90
A. E. Barker
370
Back end of front end loader while asbestos was being worked into landfill
35
Back end of front end loader while asbestos was being worked into landfill
10
Back end of front end loader while asbestos was being worked into landfill
15
Drum crusher area
304
On side of bulldozer while asbestos was being worked into landfill
15
0.01 0.018 0.028
0.021 0.016 0.020 0.029
0.39
1.2
**
0.0047 0.98
Personal sample results are reported as time-weighted averages. Sample could not be analyzed for asbestos fibers due to excessive dust accumulation.
UCC 008994