Document borMvNK8xgJQQY1NJ25E7mRo
PLAINTIFF'S EXHIBIT
TECHNICAL SPECIFICATIONS
SPECIFICA. IONS CLASSIFICATION:
CertairileedH
Advance A/C Standard Product Specification
T.C.O. REF. NO.
SPECIFICATION NO:
PACE no.:
CertainTeed Corporation Pipe and Plastics Group
description:
1 SUPERSEDES:
None
61 DATE OF ISSUE:
11-3-30
A/C Air Duct Pipe - Plant 258 Only
1.0 Genera 1:
This Advance Specification is being issued in order to set forth the anticipated requirement for the kinds of pipe that will have to be manu factured in order to re-enter this market.
This Specification covers sizes 6" thru 2**"; the 18", 20" and 2V sizes
being additions to the previous product line. The proposed dimensions
and furnishes have been discussed with Mr. Benhardt and he has agreed that
the proposal is proper for this initial venture.
j
The pipe will be square cut and clean of dust.
The coupling will be an outside purchased item.
No fittings are required.
2.0 Compos ? tion:
Air Duct pipe shall be composed of an intimate mixture of portland cement, asbestos fibers and silica. The material shall be of laminar construction formed under pressure to a homogenous structure and cured to meet the phy sical and chemical requirements of this specification. The pipe shall be free of organic additives.
3.0 Type: The pipe shall be Type II.
. n Dt . , ,,
4.0 Physical Requirements:
CTD011982
k.1 Appearance
I*. 1.1 The I.D. shall be free from dents or tears that result in a variation in diameter of more than 3/16 inch from the diameter of the adjacent unaffected portion. No water marks are allowed.
i*.1.2 Some external denting is allowed on the outside (B.O.D.) of the pipe providing there are no cracks connected with the dents.
1*. 1.3 Pipe ends shall be cut clean, with no "lace curtains".
PREPARED BY:
02-10-002? a/m
APPROVED BY: CONPIOI
R *D
MPO.
n
SALES
J#.A-
I.C.
Q. C.
OTHERS
description:
DATE OP ISSUE:
11-3-80
SPECIFICATION NO:
6
A/C Air Duct Pipe - Plant 258 Only
PAOC NO.:
2
4.1.4 It is imperative that the product shipped to customers be free of any fiber or fiber-like material.
4.2 Crushing Strength
Each pipe shal1 be capable of withstanding a crushing strength of 500 lbs./ft. min
Standard Test - One crush test every 600 pipe for 6", 8", 10" 400 pipe for 12", 14 ", 16" 200 pipe for 18", 20 ", 24"
5.0 Chemical Requirements :
Uncombined Calcium Hydroxide shall be 1.0 max. when tested in accordance with ASTM C-500.
6.0 Dimensions
6.1 Ova 1ity
The maximum ovality allowed shall be :
6", 8", 10" 12", 14", 16" 18", 20", 24"
3/8" 7/16 11 1/2'
6.2 Lengths
Standard 13' +0 " -1"
Random 7'0" to 12'6" in 6" increments +0" -1"
No more than 15% of the footage on an order may be in random lengths
6.3 1 .D. 's & B.O.D. 1 s
Size"
Nominal 1 .D.
B.O.D. +.08" -.00"
6 6.00 8 8.00 10 10.00 12 12.00 14 14.00 16 16.00 18 18.00 20 20.00
24 24.00
6.61 8.74 10.99 13.24 15.23
17.1*0
19.60 21.66 25.88
CTDO11983
TECHNICAL SPECIFICATIONS
CertairileedH
SPECIFICATIONS CLASSIFICATION:
Advance A/C Standard Product Specification
T.C.O. REF. NO.
SPECIFICATION NO:
PAGE NO.:
CertainTeed Corporation Pipe and Plastics Group
description:
1
supersedes:
None
6
DATE OF ISSUE:
3
A/C Air Duct Pipe - Plant 258 Only
7.0 Ma rking:
7.1 Each pipe shall be stenciled in the middle with black ink:
CERTAINTEED SIZE
AIR DUCT
7.2 Each pipe shall have stenciled to the right of the above marking:
First line - Month, Day, Year, Plant, Shift Second line - Pipe No.
7-3 At either end of the pipe, a "handling label" (see Sec. D of the General Standards Manual) shall be attached to the B.O.D. of all pipe.
CTD011984
PREPAREO BY:
Oj\t
02-10-0023. 4/00
APPROVCO by:
R *D
MFO.
SALES
I.C. o.c.
"'Vvv^
x/Ad.
CONFIDENTIAL DOCUMENT NOT TO BE DISTRIBUTED TO UNAUTWOWlTrn orattnuun
OTHERS