INTERIM BULLETIN SP-1TC
"Nottai mUinatf twain n lo N cwiilrauli trantimndiliM I; tm any product in conflict with any patent. MONSANTO MAKES NO WARRANTIES AS TO THE flTNtSS OR MERCHANTABILITY Of ANY PROOUCT REFERRED TO. no lutuntai ol setiifactory rawita from rolionco upon eontainad nlormation or lacommandationa, and dlacUimi oil liability lor any raiuitmi iou or dam|0."
HONS 077977
THERMINOL CONVERSION BULLETIN
INTRODUCTION Thermlnol FR fire-rosistnnt hoot transfer fluids have long provided safe, dependable, economical performance for hundreds of users in dosens of appli cations. The presence of polychlorinated biphenyl (PCB) in the Thermlnol FR formulation provided flre-reaiatance, giving Thermlnol FR an added margin of safety which was especially desirable In hazardous applications.
Most recently, PCB has been Identified ae a potential hazard to the environ ment. Monsanto has accordingly elected to discontinue the manufacture and sale of Thermlnol FR fluids for heat transfer applications. This bulletin la to Inform you about two alternative products sold by Monsanto which do not contain FCB, namely Thermlnol 55 and Thermlnol 66.
These producta offer most of the excellent heat transfer characteristics of Thermlnol FR fluids, and even a few additional advantages, such as a lower specific gravity for improved pumpablllty requiring less horsepower. We would point out that Thermlnol 55 and 66 are not flre-realetant to the extent the Thermlnol FR fluids were, and due consideration roust be given this fact In con verting to these newer Thermlnol fluids. You may wish to consult with your Insurers on any conversion from Thermlnol FR.
Conversion from a Thermlnol FR fluid to a Thermlnol 55 or 66 fluid will be a relatively simple, low-cost procedure In the majority of cases. Incorporation of proper fire protection equipment will be the only consideration of major consequence In most caccs.' But even this modification becomes academic, for
MONS 077978
vlth the discontinuation of Thermlnol Fit fluids, fire protection equipment becomes necessary for any and all low pressure heat transfer media available today, since the Thermlnol FR fluids were unique In their flre-reslstance.
Should questions arise with respect to the conversion from Thermlnol FR fluid, Monsanto's Specialty Products Croup Invites you to call upon Its staff or qualified systems engineers for consultation at any time. Call...
(314) 694-2514 and ask for a Monsanto Heat Transfer Specialist.
Thermlnol 55 and '66 and Your Heat Transfer System Table I shows the typical physical, chemical and thermal properties of Thermlnol FR-1, Thermlnol 55 and Thermlnol 66. As you will note, Thermlnol 55 and 66 are quite similar except with regard to AIT, Fire Point and density. The substantially lower density of Thermlnol 55 and 66 means that pumps used in a Thermlnol FR-1 system should be adequate for a Thermlnol 55 and 66 system. In most cases, pumping rates will be Increased with a resultant saving In horsepower requirements.
Thermlnol 55 and 66 have outstanding heat transfer properties, so heating and cooling performance will not be sacrificed in a change from Thermlnol FR-1. The specific heat and thermal conductivity of Thermlnol 55 and 66 are shown, along with other physical properties, in Tables 2, 3 snd 4, and In Figures 1, 2 and 3. The lower pour points of Thermlnol 55 and 66 will provide easier cold stsrtup of the system.
Cenerally speaking, then, a well designed system currently operating on Thermlnol FR-1 can be converted to Thermlnol 55 and 66 with few, If any, basic
2MGNS 077979
TABLE I
TYPICAL PHYSICAL, CHEMICAL & THERMAL PROPERTIES
Therminol FR 1
Therminol 66
Therminol 55
'Composition
Maximum Bilk. Temperature Reting (F.)
Recommended Use Range (F.)
Pour Point (F.)
Pounde/Callon (75F.)
Flash Point (F.)
Fire Point (F.)
AIT <F.) '
Bolling Range (F.)
Molecular Weight
Expension
Q
Coefficient cc/cc/ F.
Polychlorinated Biphenyl 600F
45 - 575F.
2 11.55
350 None to Bolling 1206F. 620 680 265 0.00031
Modified Terpheny1
650F.
Alkylated Aromatic
600F.
45 - 635F.
-15 8.35
355 374 - 392
705 644 - 745 240 0.00039
20 - 575F
-40 7.4
355 410
670 635 - 734 340 0.00047
-3MOMS 077980
Table 2. THERMIHOL FB-1 VARIATION OP PROPERTIES WITH TSMPEBATUBE
Tempe ratu re
Dens Ity
Specif lc Heat
Thermal Conductivity
Viscosity
*P *c lb/ Kg/m3 BTU/lb Kcal/Kg BTU/ft Kcal/m Cp
gal
*P c hr "? hr *C
50 10 11.68 1399.6 0.272 100 38 11.46 1372.7 0.282 150 66 11.22 1343.7 0.291 200 93 10.99 1316.7 0.3047 250 121 10.76 1289.1 0.3151 300 149 10.53 1261.3 0.3255 350 177 10.30 1233.5 0.3359 'too 204 10.07 1205.8 0.3464 450 232 9.83 1178.0 0.3568 5C0 260 9.60 1150.2 0.3672 550 288 9.37 1122.5 0.3776 600 316 9-14 1094.7 0.3880 650 343 8.91 1066.9 .0.3985 700 371 8.68 1039.3 0.4089
0.272 0.282 0.291 0.3047 0.3151 0.3255 0.3359 0.3464 0.3568 0.3672 0.3776 0.3880 0.3985 0.4089
0.06096 0.0907 0.06060 0.0902 0.0602: O.O896 0.0597* 0.0889 0.05927 0.0882 0.05875 0.0874 0.05815 0.0866 0.0576( 0.0857 0.05697 0.0848 0.0563< O.O838 0.0556c 0.0827 0.0548" 0.0817 0.05405 0.0805 0.0532' 0.0793
308 23.2 6.6 3-4 2.3 1.4 1.0 0.8 0.6 0.5 0.4 0.4 0.3 0.3
Cs
220 16.9 4.9 2.6 1.8 1.1 0.8 0.7 0.5 0.4 0.4 0.3 0.3 0.3
MOMS 077981
Vapor Pressure
mmHg absolute
Kg/cm2
--
-_
- -
--
--
-10 0.0136
27 0.0367
65 0.0884
143
0.1945
291
0.3958
550
0.7480
18.8psla 1.3218
31.9psla 2.2429
Tabla 3.
THERKIMOL 66 variation op PROPERTIES with tehperaturb
Tempe rature
Dens Ity
Specif lc Heat
Theraal Conductivity
Viscosity
vapor Pressure
r c lb/ Ks/m^ BTU/lb Ken l/lvj
gal
*P *c
u
~ff.67_ 1040 0.320
0.320
10 8.51 1G20 . 0.350
0.350
ICO 38 8.34 1000 0.330
0.380
150 66 8.14
975 0.405
0.405
200 93 7.91
950 0.430
0.430
250 121 300 149
7.77 7.59
930' 0.455 910 0.480
0.455 0.480
350 177 7.33
885 0.505
0.505
!00 >04 7.17
860 0.530
0.530
*50 232 7.04
840 0.555
0.555
300 160 6.75
810 0.580
0.580
350 ?88 6.62
793 0.605
0.605
300 3 IS 6.42
770 0.630
0.630
;50 B43 6.24
750 0.655
-oo -6.09 -130- 0.660
0.655 0.680
MOMS 077982
EiU/rt rCcal/m hr P hr C
0.0720 0.1072
0.0711 0.1058 0.0703 0.1046 0.0695 0.1034 0.0587 0.1022 O.C678 0.1008 0.0670 0.0997 0.0662 0.0985
0.0653 0.0972 0.C545 0.0959 O.0637 0.0948 0.0628 0.0935 0.0620 0.0923 0.0513 0.0912 0.0505 0.0900
Cp Cs
62000 500C0
255
250
28.0
28.0
9-75 4.18
10.0 4.40
2.42
2.60
1.55 1.06
1.70 1.20
0.77 0.58 0.45 0.36
0.90 0.69 0.55 0.46
0.34
0.27 0.20
0.44
O.36 0.28
irjnHs absolute
0.1
2.0
20.0 50.0 100.0 200.0 350.0 760.0 1000
Kg/cm^
0.003 O.C27 O.068 0.136 0.272 0.476 1.034 1.360
Table 4. IHESMDiOL 55 variations op properties with TEMPERATURE
Temp f?-
rata re
Dens:Lty
Specific Heat
*P c lb/ Kg/ra3 8TU/lb Kcal/kg
gl
*P *C
0 -18 100 38 200 93 300 149
400 204 500 260
600 3l6
.7.62 7.31 7.00 6.69 6.39 6.07 5.76
915
&78
0.420 0.472
84o 0.522
803
0.572
766
0.620
*1*'->r^ 0.670
691
0.718
0.420 0.472 0.522 0.572 0.620 C.570 0.718
Thermal Conductivity
BTU/ft Kcal/m hr *P hr C
0.0313 0.1210 0.0764 0.1167 0.0753 0.1121 0.0724 0.1077 0.0692 0.1030 O.C561 0.0934 0.C630 0.0938
Viscosity
Cp Ca
1472
1610
25.4
30.1
4.20
5.0
1.69
2.10
0.904
1.18
0.583 0.415
0.80 0.60
Vapor Pressure
ircnK3
absolute
O
Kg/cm
0.5 3.0
10 40 . 100 250
'. 0.001
0.004 0.014 0.054 0.136 0.330
' XCt2/il
c
<au)>i
V
Figure 1 THERMIMOL FH-1 - PBXSICAL PBOPEBTIES
HONS 0 7 7 9 8 <
Figsra 2 TBEBHDOL 66 - FHTSICAL PB0PEHTIE3
figure 3 1HBHHIH0L 55 - PHYSICAL P80PESTIES
DS'.aXTY -- L 2 3 ./C A L MONS 0 7 7 9 8 6
change* In dealgn -- and without sacrifice to heat transfer efficiency. With the similarity of the heat transfer properties of the three fluids thus established, let us turn to the Important differences between Thermlnol FR-1 and Thermlnol 55 and 66: namely, fire resiatance and oxidation-resistance.
Flre-Rcslstance As stated In the Introduction to this bulletin, the Thermlnol FR fluids were unique In their Inherent fire resistance. No other commonly used heat transfer medium could be so classified. Even so, the Thermlnol FR fluids could be made to bum under certain conditions, as indicated by their AIT of about 1200F.
It Is Important to realize that Thermlnol 55 and 66 are less fire-resistant than Thermlnol FR-1, and to modify the heat transfer system accordingly, It Is equally Important to understand that Thermlnol 55 and 66 are not volatile, highly flammable fluids but rather combustible as defined by FM and NFPA (NFPA NO. 321).
Protecting the System There are two major fire protection considerations In changing to Thermlnol 55 or 66 -- system leakage and possible tube rupture (In the heater). The former Is actually part of the larger subject of good system maintenance, and should be considered regardless of the heat transfer medium employed. A tight, wellmaintained ayatem la usually a good, safe system! Following are some suggestions to prevent leakage when you convert to Thermlnol 55 or 66.
First, If your system has rotary mechanical seals, you should provide a spray shield and a drip pan with a drain to a collection sump. Canned and seal-less pumps offer excellent protection against leakage.
4*GNS 0779flp
The best way to prevent piping leakage ie to veld all connection!. Where you nuat have access, use raised-face flanges with appropriate gasketing and high-temperature bolting. Control of piping leaks Is especially Important, since fluid-soaked Insulation poses a more serious hazard than the leaking fluid, Itself.
Organic compounds such as Therminol 55 and 66 exhibit a slow oxidation reaction with the air trapped Inside the voids of che Insulating material when system temperatures reach about S00F. Saturated insulation offers a large fuel surface In the face of poor heat dissipation conditions, and this, along with possible catalysis from the Insulating material (magnesia, silicate-bonded asbestos or calcium silicate) can cause a temperature build-up In the mass. This temperature bulld-up can result In Ignition of the fluid when the space betvean the piping and the saturated Insulation Is exposed to air (l.e., should the Insulation bo broken for' repair, etc.)
This phenomenon is not fully understood, but appears to occur less with closed cell Insulation than with the insulating materials mentioned above. Closed cell Mtcrlele, then, ere preferred, especially where leakage la a possibility despite ell precautions.
The principle1 problem areas ere near lnatrument connections, valve packing glands, flanges, and where cracks develop in relatively impermeable Insulation cement adjacent to oil soaked Insulation.
To obviate this problem, eliminate any source of leakage promptly. Replace leaky gaskets, oil aoeked insulation, and re-peck valve stems. Cover insulation where look* might occur with a hydraulic setting, oll-reelatant cement. In stall valves, where possible, with the stems In a horizontal position so thst
5- MOhS 077988
leak* will drip awv from the Insulation. And again, ua* closed cell insulating materials on suspect piping areas.
Tube Kuoture In Fired Hesters Generally speaking, where fire protection is concerned, it is best to consult your insurance underwriter for guidance and councel. Likewise, you will want to discuss your fire safety equipment requirements with qualified suppliers of fire protection equipment. Selection and siting of fire protection equipment is important to safeguard the installation.
A commonly used method of preventing fire in the event of tube rupture in fired heaters is piping steam of CO2 as a snuffer into the combustion chamber of the heater. Usually a properly-sized line with a remote manual valve for activation is the preferred arrangement. This snuffer system could be automated by the use of an exhaust stack temperature switch. This switch would then energize a solenoid valve and alarm upon excessive temperature rise, automatically flood ing the chamber with a fire extinguishing agent.
In practlco eh* temperature switch is often set about 100F. over the normal ex haust temperature to prevent nulance shutdowns. Where steam snuffer systems are used, It is a good idea to employ a steam trap to avoid slugging the com bustion chamber with water when the system activates, or is activated manually.
You can obtain a basic guideline in the selection of COj protection equipment (egaln, it la best to consult your Insurance underwriter) from the National Fire Protection Assn., 60 Batterymarch Street, Boston, Mass. 02110 AC 617 482-8755. NFPA Bulletin No. 12 dated 1968 should be requested. This bulletin should be helpful in determining the amount of COj and the concentration of COj needed to extinguish a fire based on your specific application.
-6- MGN5 077989
COj cylinders ere available from Cardox Division of Chemetron, Chicago, 111, as well as other auppllers. Some standard sizes are SO, 75, 100 and 150 pound cylinders. Prices usually Include drawings of the units, fully charged cylinders, floxlble piping connectors, spray nozzle, pressure switch, alarm and automatic control, provided C07 release signal Is supplied by customer device. Piping, wiring, and Installation labor to be provided by the customer. Recharging of spent cylinders Is available at an additional coat from a variety of "Fire & Safety Equipment Suppliers" listed In the Yellow Peges of your phone book.
Selection of all equipment and Installation recommendations should be obtained from qualified suppliers; howover, it is Important to Insure chat sufficient COj la available to prevent re-lgnltion while the heater la cooling.
The llalon Fire Suppression System Is a possible alternative to a CO2 arrange ment because It can be used in closed spaces with personnel In the area. One supplier of Halon systems Is the Cardox Division of Chemetron Corporation, Chicago, 111. 60611.
Again, we strongly recommend that the advice of fire protection companies be solicited In either case to insure proper equipment selection and installation.
If steam la to be used rather than the other alternatives suggested above, please refer to tha NFPA Volume I, Section 86A (1970-1971) to obtain the volume of steam required.
Oxidation-Resistance
.
With a Thermlnol 55 or 66 system, some provision should be made to prevent
oxidation caused by air contact at fluid temperatures exceeding 200F. This
was not the case with Thermlnol FR fluids, buc must be observed for Thermlnol 55
MONS 077990 -7-
and Thermlnol 66, Oxidation can result In sludge formation, eventually leading to carbonaceous deposits on host transfer aurfaces and at mechanical seal faces.
Oxidation of fluid can develop by air contact In an open, vented expansion tank. Therefore we recommend that the expansion tank be blanketed with an Inert gas (such as nitrogen) as shown In Figure 6. If this la not possible, air contact can be minimized by a cold seal arrangement as shown in Figure 5. An Inert gas pressure of one to two psl is adequate, as Thermlnol 55 and 66 do not require pressurization to maintain liquid phase.
.You can design the cold seal arrangement quite almply by piping Che expansion tank vent to a second tank where the vent line projects subsurface and can be flooded with additional Thermlnol 55 or 66 to minimize air Ingress to the ex pansion tank vapor space.
In converting from Thermlnol Fit to Thermlnol 55 or 66, It la Important to remember that many Thermlnol FK systems were designed with a hot bleed line Into the expansion tank to eliminate moisture accumulation. Moisture accumula tion In the presence of hydrogen chloride gas released during the decomposition of tha FR fluids could contribute to acidity problems. This Is not the case with Thermlnol 55 or 66; therefore, this bleed line should not be used during normal operation of a Thermlnol 55 or 66 system. This line should be valved off during operation but It could be retained as a convenient means of venting the system during Initial startup after conversion.
Further protection against a hot expansion tank occurence would be tha re moval of any expansion tank Insulation and feeder line Insulation.
-8-
MCNS 077991
Figure 4. .SUGGESTED INERT GAS ARRANGEMENT
FOR EXPANSION TANK
MOMS 0??99i
Figure 5. SUGGESTED COLD SEAL ARRANGEMENT
FOB EXPANSION TANKS
HONS 077993
Carbonaceous deposits can also occur ac the pump teal face due to leakage at high temperatures. The uee of a seal flush system or a double mechanical aeal la helpful In preventing excessive seal wear.
Converting to Thermlnol 55 and 66 With fire-protection and oxidation-resistance procedures well In mind, let us turn to the matter of preparing the Thermlnol FR system for Thermlnol 55 or 66.
Accumulation of debris over the years In the system could cause serious pro blems, especially to mechanical seals, rotary Joints, etc. All heat transfer system* should be cleaned from time to time as a part of normal preventive maintenance. Since a fluid change Is necessary at this time, It would seem practical to use the downtime to thoroughly clean the system prior to startup on a fresh charge of fluid. We strongly advise you not to simply drain and change, but to take this opportunity to clean your system. Many potential problems will be pre vented by so doing.
Another reason for cleaning your system at this time Is to assure complete re moval of the Thermlnol FR fluid. A system cleanout is the only aure way to do *o. How to go about Che cleanout Is a matter of choice, but here are some alternatives for your consideration:
A. Fluid Flush Cleaning This method is probably the fastest and most effective where heating surfaces are not heavily fouled. It also offers the
advantage of not having to Introduce foreign chemicals into tha system.
-9HONS 07799b
With this method, the system la drained of Thermlnol FR, re-fllled with Thermlnol 55 or 66, operated for a reason* able period of time, drained once again, and finally, re charged with freah Thermlnol 55 or 66,
Both the drained Thermlnol FR and the Thermlnol 55 or 66 used to flush the system may then be returned to Monsanto for disposal.
B. Solvent Cleaning This method la satisfactory for cleaning a slightly soiled system, but chlorinated solvents must be avoided. Typical aolventa used are acetone, benzene, and xylol (caution should be used with low flash point solvents). Do not use trlchlorohcnzcno or perchloroethylene. (CAUTION: ALL SOLVENTS SHOULD BE COMPLETELY RDIOVED FROM THE SYSTEl PRIOR TO CHARGING WITH THERMINOL 55 OR 66). Normally this Is accomopllshed by drying the residual with warm air or by operating the refilled Thermlnol system at a temperature lightly above the boiling point of the solvent until the residual is vented from the system. Some caution should be used in drying the system to prevent flashing of the solvent with resultant discharge of Thermlnol from the system. Both the drained Thermlnol FR and the flushing solvent may then be returned to Monsanto for disposal.
Fluid Disposal Monsanto offers an incineration service for the disposal of PCD heat transfer fluids and the flushing fluids mentioned above. For details of this service
-10-
MCNS 077995
and how to return fluids to Monsanto for disposal, please write:
Monsanto Company F.O. Box 14617 St. Louis, Missouri
6317B
...or call (314) 694-2514 and ask for a Monsanto Heat Transfer Specialist.
Handling; General Information Heat transfer fluids are intended only for Indirect heating purposes. Under no circumstances should any Therminol heat transfer fluid be allowed to come In contact with or In any way contaminate food, animal feed, food products, food packaging materials, food handling equipment, pharmaceuticals or any food-related Items.
Therminol 55 and Therminol 66: Safety of Handling
-
According to the definitions of the U. S. Federal Hazardous Substances Label
ing Act, Therminol 55 and 66 are not toxic substances since the oral and dermal
lethal doses In animals are greater than 5 grams per kilogram of body weight.
Additional snlmal studios Indicate that they do not have significant skin
or eye Irritation potential. It la suggested however, that good Industrial
practice relating to the avoidance of repeated and prolonged skin contact to
any Industrial chemical, heat transfer fluids, or petroleum product be followed.
Therminol 55 and 66 have such low vapor pressures at ambient temperature that Inhalation of vapors during transfer of fluid from shipping containers ..o a heat transfer system presents no hazard. Vapors emitted by either fluid at elevated temperatures may be Irritating as would be the case with excessively heated petroleum oils. In heat transfer Installations, the fluids arc used In a closed, unpressurized system free from leaks and with the expansion tank
11HOttS 077996
vent trapped so as to condense any vapors and thus prevent their escape to the work environment. Consequently, there should be little or no opportunity for workers to experience any contact or exposure.
While It is believed that Thcrmlnol 55 and 66 pose no serious problems with respect to the environment, as a concerned supplier to Industry, Monsanto urges the user to maintain a tight system, to correct leakage promptly, and to exercise care In the handling and disposal of this and all other such products. A tight maintenance program not only protects the environment, buc keeps employes comfortable, the working area clean, and the system running smoothly.
-12-