518 CHAPTER 27 . 1965 Guide And Data* Book Table 26 .... Rales of Heat Gain from Occupants of Conditioned Spaces* Doproo of Activity Typical AppBea&oa Total Heat Adults, Told Heat Ad Swribte Heat Male fifv/Kr justed* fito/Hr Btu/Hr latent Heat Bht/Hr Seated at rest.................................................. .Theater--Matinee............. Theater--Evening........... 390 1 390 8eated, very light work................................ Offices, hotels, apartments 450 Moderately active office-work.................... Offices, hotels, apartments 475 Standing, light work; or walking slowly.. Department store, retail store, dime store........... 550 Walking; seated.............................................. Drugstore, Bank................ Standing; walking slowly............................ 550 Sedentary work............................................... Restaurant*.......... .......... 490 light bench work........................................... Factory................................ 800 Dance hall.......................... 900 Walking 3 mph; moderately heavy work.. Factory................................ . 1000 Bowling0.............. ............................................. Bowling alley.'................... 1500 .. 330 350 400 450 450 ' 500 550 750 850 . 1000 1450 180 195 195 200 200 200 220 220 245 : 300 465 ' . 150 : 155 '205 250 250 ` 300 330 . 530 \ . 605 700 . 985 * Net*: Tabulated values are baaed on SO F room dry-bulb temperature. For 78 F room dry-bulb, the total beat remain* the same, but the eenaible heat exists be fnirmrrt by approximately 10 peroent, and the latest heat values daereaeed accordingly. * Adjusted total Jud poin U bwd on normal percentage td atm, women, and children for the application listed, with the postulate that the gain from an adult fe male m 86 p*rr**'t td that (or an adult mala, and that the gals from a child is 75 percent of that (or an adult male. * Adjusted total beat value for esdotforv work, mtnvrant, include* 60 Btu per hour for food per individual {30 Btu eenaible and 30 Btu latent), d For hoteisap figure one person per alley bowling, and all others as sitting (400 Btu per hour) or standing (560 Btu per hour). One important purpose of the cooling-load estimate is to determine the conditions and quantity .of air supplied to-the space. 'Ail the various sensible and latent -heat loads within the space must be included. Infiltration must be,included in the space load since this air enters the doors and windows, and its heat and moisture load must be.offset by the intro duction' of cooler, dryer air to the space. However, since outdoor air is taken through -the conditioning equipment and cooled, this portion does not become a part of the space load, except a small portion which, passes through the coil untreated. To determine the total load on the refrigeration machine, the remaining outdoor-air load must be included in the grand total load. Example 9: For outdoor design conditions of 95 F dry-bulb and 75 F wet-bulb, and indoor design.conditions of 80 F drybulb and 67 F wet-bulb and for the supply of outdoor air at the rate of 1000 cfm and the exhaust of room air at the corre sponding rate, calculate the total, sensible, latent heat gains. ,t Solution: Substituting in Equation 6: q, - 1000 X 1.08 (95 - 80) - 16,200 Btu per hr. From psychrometric data W, TM 0.01413 Wt " 0.01122. Substituting in Equations 7.and 8: . - 100 X 4840(0.01413 --0.01122) - 14,100 Btu per hr. 9` ".? +? " 30,300 Btu per hr. HEAT SOURCES WITHIN THE CONDITIONED SPACE People.- The1 rates'at Which heat'and- moisture 'are given off by human beings under different-states of activity are given in Table 26. In many applications these sensible and latent heat gains-become, a large fraction of the total ,load. Appreciable variations in heat-emission rates, must be recog nised according to the age and sex of.,toe individual, state of activity, environmental influences, and duration of occu pancy (since for short occupancy the .extra heat and moisture brought in by people may be a significant factor).. . - While Chapter 7 should be referred to for detailed informa tion; Table 26, in this chapter summarises practical' data representing conditions commonly encountered. Lighting. In general, the instantaneous rate of heat gain from electric lighting4* may be calculated from the following relation: ' 9* (total light (use ^ (special allow- X 3.4i; B(tuh (wattage* . .(factor . - lance factor The total light wattage is obtained from the ratings of all fixtures installed, both for'general filumination and for dis play use. The use factor is the ratio of the wattage in use, for the con ditions under which the load estimate is being made, to the total installed wattage. For commercial applications such as stores, the use factor would be unity. -The special,allowance factor is introduced to care for fluores cent fixtures, and for fixtures which, are-either ventilated or installed so that only part of their beat goes to the conditioned space. Porfluortsccnt fixtures, the special allowance factor is recommended'to be taken as'1-20 in order'to allow-for power consumed in therfaflash For ventilated fixtures,'recessed fixtures, and the like, manufacturers' or other data4* must be sought to establish the fraction of the total* wattyge which may be ex pected to enter the conditioned spaced ' Power. When equipment of any sort is.operated within, the conditioned spaoe by electric motors, the heat equivalent of this operation must be considered in the cooling load. The general equation for calculating this.load is: - (9* Horsepower Ratings /Load ' X 2544, Btuh (15) Motor Efficiency / \Factor. It is assumed that both the motor and the driven equipment are within the conditioned space. If the motor is outside the space, then do not divide by-the motor efficiency in Equation 15. The load factor is merely the friction of the rated toad which is being.delivered under toe conditions of the cooling load estimate. Motor efficiencies may be approximated as follows: about 50 to 60 percent at Jhp rating, increasing to 80.percent at 1 hp, and to 88 percent at 10 hp and above.' Air-Conditiorving Cooling toad 519 Appliances. Care must be takenin a=coo!ing4oad estimate- heat may be assumedto* be latent and the-remaining 66 per to into account the heat gain from'all appliances, elec-- ~ cent sensible heat. .-. . ... tricali'gas, or steam. Table 27 presents recommended data*3 for estimating the The most common types of heat producing appliances found rate of heat gain from commercial cooking appliances. The is toe conditioned area are those used for food-preparation in' ' - data in the last column assumes installation under.a properly fPfnmPTi-iftl and industrial food-service establishments such, designed exhaust hoodconneeted to a m*ybftni<-Rl fan-exhaust as restaurants, institutions, hospitals, schools, dubs, hotels system. For poorly designed or undersized exhaust systems am4 in-plant cafeterias. Counter and back-bar appliances are the heat gains listed should be doubled, and half of the frequently located in the dining or serving area while heavy . increase msaimi-H as latent heat. .u duty equipment is usually confined to the kitchen and.in Laboratory tests41 have shown that radiant heat tempera stalled under an exhaust hood. However, since toe trend is to ture rises can be substantially reduced by shielding the fronts air condition thekitchen as well as the dining area, a method of cooking appliances'.-These reductions amounted to 59 per-' to estimate, .the cooling load due to both types of appliances . cent with asbestos paper, 61 percent with glass panels and 78 is needed! " ..percent using polished aluminum shielding. A flooralot'air Laboratory tests41 show that appliance surfaces contribute curtain in front of the appliances reduced the radiant tem most of. the heat to commercial kitchens and that when perature rise by 15 percent. jpgfaxHpH under'an effective hood the cooling load is inde For each meal served the heat transferred to the dining pendent of the fuel or energy employed for similar equipment space is approximately 50 Btu per hr, of which 75 percent is doing the* same cooking operations. The tests also indicated sensible and 25 percent latent. that the'heat is primarily radiant energy from the appliance Heat guns from cooking appliances, motors, lights,- and surfaces and cooking utensils and that convected heat and people are not considered in cooling load calculations if the latent heat is negligible. appliances are located in a separate kitchen that is not'part A conservative estimate as to the ma-rimnm heat released of the conditioned area. into the kitchen due to radiation is 32 peroent of the tnarimnm Table 28 lists suggested** rates of heat gain for miscellaneous hourly Btu' input to hooded appliances. The magnitude. of electric and gas,appliances. this maximum hourly,input can.be safely'estimated as 50 percent of the total nameplate or catalog input ratings be LOAD FROM MOISTURE TRANSFER THROUGH cause of diversity of appliance use and the effect of thermo- -. PERMEABLE BUILDING MATERIALS static controls. Numerous demand studies by utility compan The diffusion of moisture through all common building ies confirm this usage factor of 0.50 for commercial cooking materials is a natural phenomenon which is always present to equipment. Therefore the maximum' hourly'heat gain for' i a greater or lesser degree. electric and steam appliances installed under a hood can be * . The permeability and permeance values for various build- estimated-from the following equation:-.. i materials are given in Table 2 of Chapter 23, - together 9* " qt X Fo X P'm ` (16) with an explanation of moisture transmission through these or materials. In toe usual comfort air-conditioning application, it is 9. - 0.16*94 ' - (17)* common practice to neglect moisture transfer through walls, Direct fuel-fired cooking appliances require more toeat ` because the actual rate is quite small and the corresponding input than electric or steam equipment'of-the same type and latent-heat load is hardly significant. Vapor barriers are rise. In the case of gas fuel, field studies*0,11 have established, frequently employed in modern construction for the purpose an overall figure of approximately ,60 percent more.-The- of keeping moisture transfer to a minimum, and reducing the laboratory teats41 already referred- to confirm that where the 'deteriorating and insulation-destroying effects of moisture. appliances are-installed under an effective hood only radiant Industrial jobs, on the other hand, frequently call for a heat adds to the cooling load and that convected and latent1 - low moisture content to be maintained in a conditioned heat from toe cooking process and combustion products are space. Here the matter of moisture transfer cannot be neg exhausted and do not enter the kite-ban. It is therefore neces lected; indeed, it is quite possible to have the latent-heat' sary to, correct Equation 16 for fuel-fired appliances to com load accompanying this transfer be of greater magnitude pensate for, the 60 peroent higher input ratings since-the - than any other latent-heat load. The equation for computing appliance surface temperatures are the same and the extra this load is: heat mput is'completely exhausted to outdoors along with the combustion products. This correction is made by the intro duction of a flue loss factor as follows: . '.t. (s~\mJALf x( V.por-Pr^x \Aj 7000 \DDiiifference, In: Hg/ v` 9< X Fg X Fa Fwl *' (18) ' q* " 0.10g,- (19) The amplified Equations 17 and 19 provide ah easy and qmck solution to/the problem of estimating toe'cooling load ' chargeable to electric, steam and fuel-fired cooking appliances located under an effective exhaust hood. -. ` Por all cooking appliances' not installed under-an exhaust hood or directly vent connected and located in toeconditioned area-toe heat gain may;bo estimated'as`50.percent (usage factor * 0.50)' of the rated' hourly input regardless of the - type energy or fuel used. On the average, 34 percent of the M -- permeance of the specimen in perms, or grains per (square foot) (hour) (inch of mercury vapor-pressure difference). ,' ' J- 7000 " grains per pound. ' * * . ; The factor 1076 is defined in list of symbols at Equation 8. (Sensible cooling of the water vapor is -included in the factor . 1076.) * ;*. The only means of preventing moisture transfer is.to-use a vapor proof wall,' or to apply a special lining,- .which* is vapor proof.-AH openings in moisture proof-construction must be equipped with special gaskets to prevent entrance of moisture. '* ,... *'.,,`7 When moisture transfer contributes an-appreciable-part- of the latent-heat load, it is recommended that estimates