Document bk6KKGJbKJpo4rMEqEYrKg0Z

go-1 184 I' '-73) INTER-OFFICE memo TENNECO CHEMICALS, INC. TO J. T, Sweeney At Flemington Date December 7, ! From R, A, Lojewski AT Flemington Subject VCM Exposure Data and TWA - Flemington Plant Area Monitoring System Period: November 20, 1976 to November 26, 1976 t Copy to W. D. Bord C. N. Brown* R, F. Fanter W. R. Fogelsanger W. F. Gabel D. M, Hershkowitz F. W. Kanzler W, Miringoff P. M. Reed S. Robbins* M, K. Rosen G. I. Rozand F. Toca R. J. Young TWA Only* Attached are Plant Summaries (Tables I-III). Table XV lists all excursions at or above 100 ppm including the number of incidents. Table V shows the TWA by job classification calculated from the data in Tables I-XIX. Graph #1 shows the percentage of readings above 1 and 5 ppm VCM for the Reactor Building while Graph #2 shows the weekly averages for the Reactor Building and the Pilot Plant. Also attached is an analysis of the Plant data by W. D. Bord. The Plant was in operation seven days for this report period running at about 100% utilization. The four G, C.'s were on computer control. Area Total >1 N% *5 N% >25 N% > 100 N% Reactor Building Recovery Comp. Room Pilot Plant General Area Parshall Flume 7,648 476 4,347 6,220 621 4720 467 342 421 62 62 98 8 7 10 415 5 449 94 11 0.3 50 0.8 2 0.3 50 0.7 4 0.8 00 4 0.06 1 0.2 5 0 0 0 0 0.07 0 0 0 0 All readings greater than or equal to 100 ppm VCM are tabulated in Table IV. Five readings at or above 100 ppm occurred this report period reflecting two separate incidents. Two incidents occurred in the Reactor Building affecting the center aisle 2nd floor, stripper platforms #1 and #2, and the panel board. There were no incidents in the General Area, or the Pilot Plant during this report period. RAL:ms R,, A. Lojewski 010317 Monitoring Point Ti^Jp I REACTG. BUILDING NX Period Covered if'Sb/n-atrfL >1 >5 `>25 > 100 Center Aisle Column #2, 1st floor Center Aisle Column #4, 1st floor Center Aisle Column #6, 1st floor #1 Slurry Transfer Pump, 1st floor #2 Slurry Transfer Pump, 1st floor DeFoamer Tanks, 1st floor VCM Day Tank Area Center Aisle Column #2, 2nd floor Center Aisle Column #4, 2nd floor Center Aisle Column #6, 2nd floor Stripper #2 Platform,, manhole, 2nd Panel Board Column #7, 2nd floor Stripper #1 Platform, manhole, 2nd Knock-out Pots, 2nd floor Foreman's Desk Dry Chemical Weiqh-up Area Stairwell in Hallway, 2nd floor Weiqh Tank Chip Basket Area floor floor Total ?38 238 MS o o732 O 238 238 22 C23L >23. 22 22 C22 22 22 22 633. 74 0.3 3 /o _ jz _ 7... SP6CML <------- :--------u1 SPCM <------------------ 0.9 38 io 2.8 /4 2. a/ 3.3 w m 4.8 _ 2.7 w/ 2$ 2.2. 2. U 4.0 fffj . Wao RECOVERY COMPRESSOR ROOM 9 /o 8 /2 7/ 77 3C Zf 37 0/ 38 4o ss 30. w/f lO 2O /O ---------------- ________3 --:--> 2 ... 0 t0 8/ t4. ________LL___ / %- _______ L_ s. 0 7 _ 0_____ 0 0 0____ So Q s Monitoring Point NX >5 ^ 25 ^ 100 #1 Recovery System #2 Recovery System 00 CO Total 338 -A32L____ 7>S 7.9 334 232. ^C7 __430 _______J.______ 0 off _/ _____ Q____ Wf R. A. Lojewski 4/7/76 TABLE PILOT PLANT Period Covered . Monitoring Point Stronq Scott Drver - Process Buildinq : Boiler House t Pilot Plant Laboratory - Process Buildinq Centrifuqe - Reactor Buildinq > "F" Reactor - Reactor Buildinq > Parshall Flume T Plastisol Tower - Reactor Buildinq } VCM Storaqe Area - Reactor Buildinq 3 "E" Reactor - Reactor Buildinq ) "B" & "C" Reactors - Reactor Buildinq */w *Tot#1 N ^57 o tel tel tel tel tel (at &?/ 4s& ___ _y___ >\ - >J>_______ 7 ^5 > 0.3, ..... 33 S?CML < -- PJ ____ O / o / o3 9 os te 1 & 0.6 30 . 3 PA. 10/ 3 o.S ....... Jl... Sf&t/Al. <------------------ o.4 d4a // Oo ------------ o ____ o_ Ol ___ _o o_ /Q ______ Q_____ O Q. .O O ------------ > oO R. A. Lojewski 1/8/76 010319 TA III GENERAL AREA ig/hPeriod Covered M6III-3C-7C Monitoring Point 1 Truck Loading Platform 2 Oualitv Control Laboratory, West 3 Oualitv Control Laboratory, East 4 Lunchroom 5 Bulk Loading Tower 6 Dryer Room 7 Bagqinq Room - Baqqers Seat 8 Maintenance Shop '9 VCM Transfer Pumps - Tank Farm .0 1 Tank Car Unloading Platform Total N 22 622 622. Las 622 22 22. 622 622 622 1 (>3S0 Y O.l 0-5" OJ O.l _ 0.2 0.2 OJ 0.7 0.9 O.tf >1 /o i7L3 o. 4 ... /8 O /2 /29 89 *6/ >5 > 35 7 O // L o /_ o. o o /r ts. So O-..- / o O..... o o ____o___ oo Q ..._0__ <0 O_____ o O ____ Q__ ....._&_____ ..,,o,, /o R. A. Lojewski 1/8/76 010320 I $rk -fine /m-n *&* /SS* ::;\:",../&? oIq9 i J Tmu :nr 1' i - --r i- !....i o/t[ 6/f^r<f/f; YM,.. j /qo ^m VC /n i :..! -i.1--4-J---4 ' L\' ! i '< t - 1 >S ..Lj_4 '--4---- 1-- L .i..j ...I. j.._L ! - : ' 1 i ! ; 5 A CoJLoA*/* i .4- }-~ ' !\! - I1! ;; - - -ii - ;! i"! ;i i'T' T -r-- J,,j_. ri !t ri` : i il m:i: j; ;I L J__ l--___ *!:r '.....r - ii 4--j-- 1 ii )i * j ij i 4--4- --t------- 4.... 4 i i i! ; i 1 l-M-rr !....... *.... _ ;i ' . , --L ~"T"'i....!** j .....l "']' T" ; .. -j] --i , -~-ij- -1J; ii : ! ... \- r-1 -1 ii; i'T' T ;.; i i ... i. I' I __ L. ! I .i ,,4. ,.j... j ....; . J ... . _____ >: !) :! 1 ;---------.u. .... -- .... J 'j -. 1 - i i [--i-r- i1 J ;-- | --4' -- --I-4- j! -! - ! i.. :....! i. .... .... -f-- r t -+ i -l- 1 : tfni 1-7C 010321 FLEM1NGTGN TIME-WEIGHTED EaPOSUhE AVERAGES CALCOLA1ED FROM BENDIa MONITORING DATA 11/20/76 TO 11/426/76 cjOB CLASS 1F1 CAT!ON TWA TABLE V RESIN PLANT POLTFGRMAN W A1H wopolxFurman ath SHIFT FORMAN W AIR SHIFT FORMAL WO AIR reactor uper-chhg w air woreactor oper-chkg air REACTOR UPER-DUMPG W AIR REACTOR oper-dumpg WO AIR REACTOR OPER-BELIEf W AIR REACTOR OPER-RELIEF WO AIR UTILITl OPER W AIR UTIL1TT OPER WO AIR DRIER OPER WAREHOUSE SUPERVISOR WAREHOUSEMAN'BAGGER i-3 2*1 -7 2*3 2.0 2*o 1.2 2.6 1*3 2*6 -b A.2 .2 *1 *2 GENERAL AREA MAINTENANCE FORMAN MECHANIC SHIFT MECHANIC DAT BOILER OPER MAINTENANCE STOREKEEPER MAINTENANCE CLERK EFFLUENT MAN W AIR EFFLUENT MAN WO AIR UC TECHNICIAN UC SUPERVISOR .2 2*2 1*2 *1 .2 .1 .2 .3 .4 .3 - GROUP LEADER ENGINEER TECHNOLOGIST TECHNICIAN W AIR TECHNICIAN WO AIR MAINT TECHNICIAN PILOT PLANT .4 .3 .3 .3 .4 .3 010322 r ~r * Bendix Data Comments for the period November 20 to November 26, 1976 Reactor Building Area: There were two reasons for the 2.0 PM average in the Reactor Building area during the time period November 20 - November 26. 1) Because of mechanical problems with the vapor containment tank,the by-pass line to the ponds had to be used. This causes the surrounding areas to be higher than normal. 2) The outside atmosphere being drawn into the reactor building was over 2 PPM. General Area; The General Area remained at a low 0.4 average. Current Projects: 1) Installation of water sprays in the reactors will be started by December 1, 1976. This project will reduce the amount of VCM fumes exhausted to the atmosphere from reactors being aired out. 2) Special Bendix heads are still being used to determine if specific operations are causing high readings. WDB:ms W. D. Bord 010325