Document bayXnk1ya0QRgBmg1weyJNVB6
246
CHAPTER 16
1965 Guide And Data Book
used to measure steady or slowly changing temperature.
For accurate results the entire thermometer coil-must 'be
exposed to the temperature to be measured.
' -'
Pyrometers
The pyrometer is the usual instrument for measuring
high temperatures such as those of incandescent bodies dr
furnace interiors. There are two types. In the radiation
pyrometer the radiant energy from an observed surface
falls on a thermopile, and the emf generated by the pile,
measured by a galvanometer or potentiometer, is an index
of the surface temperature. With the optical pyrometer a
narrow spectral hand, usually red, emitted by the surface;
is matched visually with the filament of a' special electric
lamp. The emf necessary to cause the filament to'match
the surface in brightness is the index of the temperature of
the surface. Pyrometers are calibrated by means of Various
metals with known melting or freezing points. Portableas
well as laboratory models are manufactured.
`'
Color Indicating Crayons
Crayons are available, the marks of which'change color
or melt at specified temperatures. Such crayons have been
sold in boxes covering the range from about' 100 F to about
800 F in 100 deg steps, with a precision of some 10 'deg!
They are a, rough but convenient means of determining
temperatures, and of locating isothermal lines on surfaces
below red heat.
i
Sampling and Averaging
Temperature is'usually a point measurement,-, but'is fre quently assumed representative of the value over an-area;
as on a surface or in a flowing stream. However; such ah as sumption is rarely safe without an exploration. For accurate determination of average stream temperature; it-is well to divide the cross-section into smaller areas and measure.-the temperature of each of these. The temperatures measured should be combined into a weighted mass-flow average by either (1) using equal areas and multiplying each temperature by the fraction of total mass flow in its area, or (2) using areas of size inversely proportional to mass flow and taking a simple arithmetic average of the temperatures in each.-Such-pro-, cedures are cumbersome, however, and some means of.mixing or selective sampling is preferable. While mixing may. be ob
tained by .turbulence alone, transposition is much more, effec tive for mixing. .In transposition, the stream is divided'into parts determined by the type of stratification and alternate, parts passed through each other.
Static Temperature vs Total Temperature
When a fluid stream impinges on a temperature-sensing element such as a thermometer or thermocouple, the element will be at some temperature greater than the true stream (static) temperature. The difference will be some fraction of
the temperature equivalent of the streamvelocity..
At. - V>/(2gJer) ,, '
where
}
V velocity of stream, feet per second. g acceleration due to gravity, feet per. (second) (second). J " mechanical equivalent of heat,- 778.3 ft-lb per Btu. Cp -- specific bait at constant pressure/Btu per pound. For air, tit, = 0.81 (7/100).* This fraction of the tempera ture equivalent of the velocity is called the 'recoveryfactor and varies from 0.6-0.8 for bare thermometers to 0.95 for aerodynamically shielded thermocouples! For extremely precise
temperature measurement it is necessaiy to calibrate each temperature sensor individually to determine its recovery factor. However, for most applications where air velocities are below 5000 fpm this effect can be neglected.
A variety of temperature sensors are becoming available for temperature measurement in fluid streams. Principal of these are the static temperature thermometer, which indicates true stream temperature but is very cumbersome, and the thermistor used for very accurate temperature measurement within a limited range.
MEASUREMENT OF ABSOLUTE PRESSURE
Instruments for measuring absolute pressure are listed in Table 2,-together with brief comments on each. The principal instruments will be described.
Instruments for Extremely Low Pressures
Absolute pressures in the order of 25 to 5,000 microns of mercury may be measured by means of the McLeod, the Pirani, or the electronic discharge gage. In the McLeod gage, a known volume of gas b trapped and raised to a predetermined pressure at which its remaining volume indicates the initial pressure. Accuracy b good but the instrument b not directreading and not suitable for use with gases which contain vapors that would condense during the compression. The Pirani gage measures the thermal conductivity of a gas to determine ite pressure and, therefore, depends upon accurate knowledge of the composition of the gas. Electrical discharge instruments use the discharge of electrically-charged particles impinging on a screen to determine pressure.
Barometer
The simplest and earliest type of barometer consists of a glass tube somewhat more than 30 in. long filled with mercury, and inverted in a cup partially filled with mer cury. The height of the mercury column in the tube above the mercury surface.in .the cup b a measure of.the existing atmospheric pressure, except -for the slight pressure of the mercury vapor, in the space above the mercury in .the tube. This can ordinarily be ignored. ...
Elaborate mercury barometers, fitted-with vernier scales, are available. For precise work, corrections must be made for the thermal expansion of the mercury and of the scales.* The instruments are usually calibrated for 32. F mercury and 62 F scale temperature, and the correction C.to.be sub; tracted from the observed barometer's .height. is. obtained by means.of Equation 2.-
' h(t - 28.630).. (1.11231 + 10978)
(2)
where'
C * correction to be subtracted, inches of mercury.
h observed height, inches of mercury.
,s
t observed temperature of the barometer,, Fahrenheit
. degrees.
. Standard atinospheric pressure at sea level b 29.921 in.
Hg, and since normal atmospheric,pressure decreases about
0B1 in. Hg for each 10 ft increase in' elevation, it. is im
portant .to. make & correction if the elevation of the^ba
rometer b not that of.the test apparatus. In many cases'
the - barometric reading may be obtained from a nearby
Weather Bureau Station, in which case' inquiry should be
-made 8S to whether the value is for station or sea level
pressure.
.
. ,. ,
Measurementrand Instruments
247
Table 2 .. .V Measurement of Absolute Pressure -
- * MeasvrvaMaf Mean* *1 McLeod gage
. . Application . Very law.abs press.
Resign 0-0.1 in. Hg
Pndooa 2-5%
.timitofeo '
;
; - Not direct reading; vapors tend to condense out .
2 Pirani gage
2-5%
Must be calibrated for gas com
position on which used
r
3 Absolute-pressure manometer
Moderately low abs. press. 0-30 in. Hg or above
0.01 in. Not readily portable
4 Barometer; .mercury--^nanome ter type1 ' .
*5 Differential manometer and barometer;-
"6 Evaporating liquid temp.
Atmospheric press. _
Moderately low abs. press.
On refrig, machine and for use during evacuation.
0-60 in. Hg or above
Depends on liquid
0 001-6.01 in.
6.01 in., . Awkward observation; requires two readings
* 1%`
liquid must be kept supplied; can only be used where liquid evapora
tion will not damage system
7 Pressure Transducers--strain Remote Reading, responds 0.05 to 50,000 gage, capacity, potentiometer, to rapid changes of pressure psi crystal, magnet
0.1% , Must be calibrated
Atmospheric pressure may also be measured by an aneroid barometer which b easily portable. In thb type, variations in atmospheric pressure deflect the thin surface of a sealed diaphragm capsule. Most commercially available aneroid barometers are-not as accurate as the mercurial type,-and tihe best require occasional recalibration. Open-scale aneroid barometers are more expensive than common mercurial ba rometers.
Most of the pressure gages used in engineering work indicate gage pressures, that is, the difference between the pressure being measured and the atmospheric pressure. Such pressures are called gage pressures. Absolute pressure may be obtained by adding barometric pressure and gage pressure algebraically.
Indirect Pressure Measurement
In refrigerating systems, the high- or low-side pressure b frequently determined by the measurement of the temperature of condensing or evaporating refrigerant. In obtaining this measurement,'care must be taken that there is'no sub-cooling, superheat or non-condensable gas present.
MEASUREMENT OF DIFFERENTIAL PRESSURE !
Instruments for measuring differential pressure are shown
in Table'3. A pressure differential can also be measured by
using absolute-pressure instruments and taking the difference
in their readings.
v -
Manometers
The manometer b a.simple and.useful means for measur ing partial-vacuum-and low-pressure. It- b, moreover, .a primary instrument; it does not require calibration, and it is often used as a standard for .the calibration of. other instruments. It is.so universally used that, both the inch of water and the! inch' of' mercury rhave become accepted units - of pressure measurement. In its simplest form; -tire manometer consists of a U-shaped glass tube partially filled with a liquid. A difference in height of the two fluid columns denotes a difference in height of the two legs, which b pro portional to the difference in height.
For converting, manometer readings, into other pressure units, certain proposed.standard factors are applicable for
Table 3 .... Measurement of Differential Pressures (Gage)"
No. Meaturtntni Mdoni
Application
T Jlong-
Prwfrfon
Unftofion*
.1 Micromanometer
Very low press, diff.
0.000-6 in. H,0 0.0005 in. HsO Not readily portable; not.easy to use with pulsating pressure
2 , Draft gages
Moderately low press, diff. 0.0-10 in;.HzO
0.005 in.- -Must,be leveled carefully; needs
0.05 in. H*0- - calibration ' .
3 Manometer
Medium press, diff.
0-100 in.' HiO. or Hg
0.05 in! . -
Where used with liquid must be compensated for liquid density
4 Swinging-vane type gage Moderately low press, diff.
O--) in.
0-20 in. HiO
'5% .Generally usable to atmospheric pressure only
- 5 Bourdon-tube type '
Medium to high press, diff., -usually to atmosphere-
Any _
' As high as 0.01 psi Must be-calibrated; subject to
or 0Bl% of full' damage due to. over press-ehock
scale
or pulsation .
6 Pressure Transdueere-1-
strain gage, capacity, po tentiometer, crystal, mag net '.
Remote.Reading, responds ' 0.05 to 50,000
to rapid changes of pressure
psi
':
Must be calibrated.; -