Document bax6Qe7gNkomwY7bD2Ex2xJYo
Monsanto
Monsanto Company
Houston, Taxa>s8 77027 #hon: (717> 621 -9900
March 27, 1974
Mr. J. D. Winget Army Core of Engineers P. 0. Box 1580 Albuquerque, New Mexico 87103
7
Dear Mr. Winget:
As we discussed in February, 1971 Monsanto discontinued Pydraul formulations based of polychlorinated biphenyls (PCB's). The decision to discontinue use of PCB's in Pydrauls was based on the tendency of these materials to accumulate in forms of wild life, fish and other marine life plus their resistance to bio degradation and resulting persistence in the environment. I have enclosed a copy of the FDA Environmental Impact Statement for your reference.
X would suggest that you convert your hydraulic systems contain
ing Pydraul 135 to Pydraul 50E at the earliest opportunity.
Pydraul 50E is a phosphate ester based hydraulic fluid (bulletin
enclosed) and is a fire resistant produc
Pydraul 50E is Fac
tory Mutual Approved and.passes the standard fire resistance
test as Factory Mutual Spray Test, Factory Mutual Channel Iron
Test and the Hot Manifold Test.
The points listed below may be helpful to you in converting your system to a phosphate ester fluid.
1. Viton and Teflon seals and rod packing materials are test for Pydraul 50E.
2. The PCB fluid should be drained and incinerated. Mon santo will provide this service if you wish. You should contact Mr. Joe Kleffner at 800-325-3850 to make arrange ments.
3. The reservoir should be wipped out to remove as much PCB fluid as possible and all materials incinerated.
A. The system should then be flushed with Pydraul 50E and the filter cartridges changed before the final fill with 50E.
HONS 095264
Mr. J. D. Winget Page 2
March 27, 1974
5. The flush fluid may be retained to flush other systems to be converted but should be incinerated when disposal is necessary.
6. Pydraul 50E may be ordered from Mr. Gary Graf at 800-325-3850. The price of 50E is $5.30/gal. F.O.B. St. Louis.
Hopefully this information will assist you in expediting the conversion of your systems to the phosphate ester fluid.
Please let me know if I can be of further assistance to you.
Yours very truly,
JA/md Enclosure
Jim Armentor Area Manager Specialty Products
bcc: Doug Hansen Bob Bevacqua H. R. Ford C. Paton
Note to Bevacqua - This guy called a few weeks ago and I missed getting the injfco to you. I expect 2-1000 gal. conversions and perhaps about
3 new fills later in the year. Assume you will pickup from here with Jerry Winget at 505-766-2389.
Regards. Jim
M0NS 095265