Document bavV08M7d5DrVddYw1R9qrzRk
V
Fans and Ventilating Equipment
L. J. Wing Mfg. Co.
Branch Offices In Principal Cities
663 Hudson St., NEW YORK
Phone: Chelsea 0027-0030
Factory: NEWARK. N. J.
Manufacturers of Wing Featherweight Unit Heaters, Wing Turbine and Motor Driven Blowers, Wing-Scruplex Fans and Exhausters
Wing Featherweight Unit Heaters
The outstanding features of Wing Featherweight unit heaters are their extreme light weight (about one-tenth that of the old style) and small dimen sions, combined with the fact that driving motors are direct connected (no belts) and are out of the path of heated air.
These features open a much broader field of application for this system of heating--which is generally accepted by engineers and architects as the best system for industrial plants and other buildings of large open areas such as garages, armories, etc.
The features emphasised make possible suspending the units from ceiling or roof of any building, old or new. without necessitating additional strengthen ing of the structure; and the overhead installation makes it possible to run all steam and return lines overhead out of the way.
Wing Featherweight unit heaters heat the floor or working level first. Being placed near the roof or ceiling, they withdraw the heated air which tends to accumulate there and return it to the working level where it is needed. Con siderable economy is effected by reducing the temperature directly under the roof where heat transmission is always the greatest.
, Wing Featherweight unit heaters are made in four different designs: vertical, high ceiling, vertical medium ceiling, vertical low ceiling, and horizontal.
Horizontal Type
Methods of Installation
The cuts show three different methods of installation, the units in
each case being located well above the head line, out of the way. The
third illustration shows the high ceiling type heater installed thirty feet
from the floor above a traveling crane. The column of heated air
leaves the heater with sufficient velocity to strike the floor with con
siderable force from this point, but by the aid of adjustable diffusers
the column is divided and directed so that no objectionable velocity is
felt at the head line. The best and most economical installation of
Wing Featherweight unit heaters is when they are placed close to the
roof or ceiling.
Vertical High Ceiling Heater
[M
Q
zinc DEI /N/i\ ZE lLHZ Lz
Size ' Unit
Condensed Table of Engineering Data
Ax A In.
B In.
C In.
Temperature D Air In. C. F. M. H. P. Room Leav.
B.t.u. Approx. per Hr. Shipping Available Weight
17-3-12 23x23 ?4 24 6 1950 22-3-12 28x28 27 27 6 3200 22-4-12 28x28 77 77 6 2800 22-5-12 28x28 77 27 6 2600 23-4-12 33x33 27 77 7 4800 25-5-12 33x33 77 27 7 4500 30-4-35 35x35 33 33 8 6900 30-5-35 35x35 33 33 8 6500 36-4-85 41 x4l 39 39 8 9600 36-5-35 41 x4l 39 39 8 9000
V* 65 65
H 65 65
7? 65 65
1 65 1 65 2 65 2 65
113 92.500 115 157.000 125 162.600 135 173.200 125 279.000 135 300.000 125 .401.000 135 433.000 125 558.000 135 599.400
210 270 280 290 320 330 360 360 500 530
KA
Vertical Medium Ceiling Heater
Wing Featherweight Unit Heaters
368
Vertical Low Ceiling Heater
L. J. Wing Mfg. Co.
Fans and Ventilating Equipment
WING-SCRUPLEX EXHAUSTERS
Wing Scruplex Exhausters consist of the highly efficient "screw propeller" fan and cased in appro priate manner with a motor on the outside where it is clean, cool and easy of access. They are used in duct work where the resistance is low and being de signed in the form of an elbow fit snugly in any line. The accompanying diagrams show the methods of installation.
Proper Selection of Exhausters--Where par ticularly quiet operation is de-
Bolted directly to Ceiling
JcJ?
Outlet Round. Speed R. p. n
LLlif
Hung from Ceiling
BdUed directly to Side Wall
'`BdUed-to' Floor'or
'-Foundation
' ` WING-SCRUPLEX " Exhausters
Vertical Bolted to
Side Wall
e
Free Air
.15 in.
J5 in.
.40 in.
Cu. f. m.
Hp.
Cu. f. m.
Hp.
Cu. f. m.
Hp.
Cu. f. m.
Hp.
sired, as in offices, residences
hospital wards, churches
theatres, etc., use. lowest
speeds in all sizes. For toilet
rooms, laboratories, motion
picture booths, stock-rooms,
etc., use any speed in sizes 1
and 2; low and medium speeds
in all other sizes. In indus
trial plants, hotel
and restaurant
.50 in. kitchens, engine-.
rooms, workshops,
Cu. f. m.
Hp.
etc., use any speeds.
1-A 2-A 2-B 3-S
yy--Ac
4-S 21 4-A 21 4-C 21 5-A 25 5-B 25 6-A 30 6-B 30 6-C 30
I0>/, 1750
1150 1750 17V? 850 TV? 1150 '3 1750 21% 850
850 1440 2050 2I3C 2700 4000 2850
0.052 0.060 0.195 0.090
0.180 0.600 0.100
630 950 1895 1250 2150 3720 2200
0.054 0.069 0.208 0.110 0.195 0.635 0.125
330 395 1695
1550 3510 1610
0.060 0.090 0.216
0.221 0.655 0.150
1155 3150
6.248 0.700
750 2810
0.285 0.720
The accompanying
table gives perform
ances at static presures up to H in. Com plete table up to l in. static on request.
21% 1150 2iy, 1750 25 1150 25 1750 30 600
3575 0.170 3150 0.200 7775 0.220 1950 0.245 1550 0.280
5400 5200 8000 5500
0.540 0.330 1.330 0.210
3160 4720 7740 3725
0.600 0.380 1.360 0.250
4990 475(1 7540 7375
0.650
0.440 1.400 Q.330
4670 3300 7175
0.710 0.530 1.480
4440 2610 6900
0.750 0.600 1.540
30 30
850 1150
7400 10250
0.550 1.500
6280 0.600 9320 1.550
5450 8950
0.740 1.570
4000 8000
6.830 1.620
3400 7340
0.960 1.760
WING-SCRUPLEX FANS
Wing Souplex Fans are built in the following sixes: 10 in.. 13 in., 17 in.. 22 in.. 25 in. 30 in 36 in.. 42 in.. 54 in., and 60 in. Capacities from 950 C. F. M. to 33.000 C. F. M. Up to 25 in' diameter, propellers are made of cast aluminum alloy while the larger sixes are of pressed steel'
Wing-Scruplex Fan
WING FORCED DRAFT BLOWERS
The Wing Type E M blower makes the ideal forced draft for heating bodere. This small, compact propeller fan outfit is an integral unit, ready to mstalL No belting or coupling; the fan is right on the motor shfcft. Where the base of the boiler is not high enough to accommo date the fan casing, the blower is provided with feet for mounting, placed a short distance away and connected to the boiler by means of a small piece of duct. E M units are furnished either in D. C., polyphase or single phase with speed regulation; or with squirrel cage motors and damper regulation.
Type REV. Turbine Driven
The Wing Turbine Blower, while long con sidered standard equip-' ment for supplying forced draft to handfired boilers, has in more recent years be come widely used for stokered boilers as well, a single blower deliver ing enough air to develop as nigh as 1000 h. p. Either manual or automatic operation may be had. Ask for Bulletin 67.
369