Document baQKraRwMdYzpNnmZ87BKKxyg

1 c PLAINTIFF'S EXHIBIT MON-2 C26 RESPIRATORY PROTECTION PROGRAM , (Procedure Bulletin P-0130) t APPROVED BY THE PLANT MANAGER'S SAFETY BOARD DECEMBER 21, 1978 (Re-Issued October 10, 1980) c MAP 001547 LAM023424 A NEW PROCEDURE BULLETIN PURPOSE; PROTECT EMPLOYEES FROM EXPOSURE TO AIRBORNE CHEMICALS OR PHYSICAL CONTAMINANTS DURING NORMAL AND EMERGENCY CONDUCT OF THEIR WORK EMPHASIS; PROVIDE EQUIPMENT, TRAINING, AND PROCEDURES AND REQUIRE COMPLIANCE MAP 001548 LAM023425 V f NEW BULLETIN COVERS 1. BREATHING AIR QUALITY 2. SELECTION, UPKEEP, AND TRAINING IN USE OF RESPIRATORY EQUIPMENT 3. BREATHING AIR SOURCE/SYSTEM X 4. RESPONSIBILITIES C MAP 001549 LAM023426 V c 4 BREATHING AIR OUTSIDE BATTERY LIMITS COMPRESSED AIR AVAILABLE PIPELINE HEADER SYSTEM CYLINDER OTHER * - DO NOT USE UTILITY OR INSTRUMENT AIR - NO CROSS CONNECTIONS L MAP 001550 LAM023427 BREATHING AIR OUTSIDE BATTERY LIMITS PIPELINE HEADER SYSTEM RESPONSIBILITY - UTILITY DEPT. QUALITY PLANT AIR COMPRESSORS DISTRIBUTION HEADER (UP TO 1st BLOCK VALVE AT BATTERY LIMITS) APPROVAL TIE-INS VISUAL CHECK MONTHLY WRITTEN REPORT CYLINDERS RESPONSIBILITY - STORES DEPT. CONTENTS CHECKED ON REPORT TAGGED - SIGNED LINDE DIV. UNION CARBIDE ONLY APPROVED OTHERS REQUIRE LP&S APPROVAL MAP 001551 LAM023428 BREATHING AIR DISTRIBUTION WITHIN BATTERY LIMITS OWNERS* RESPONSIBILITY - PREVENT CONTAMINATION - SAFEGUARD USE ONLY FOR BREATHING - MONTHLY VISUAL CHECK OF IN-BATTERY LINES - WRITTEN REPORT - CONFORM TO HOSE STATION STANDARDS - QUICK CONNECT SYSTEM WITH SIGN - COLOR CODING (BLUE BAND WHITE STRIPE) MAP 001552 LAM023429 RESPIRATORY SYSTEMS POLICY WE WILL MAKE CONVENIENTLY AVAILABLE RESPIRATORY EQUIPMENT SUITABLE FOR WORK TO BE PERFORMED AND EMPLOYEES REQUIRED TO PERFORM SUCH WORK SHALL HAVE HAD THE REQUIRED RESPIRATOR EQUIPMENT TRAINING AND WILL BE REQUIRED TO USE SUCH EQUIPMENT MAP 001553 LAM023430 V c V3 RESPIRATORY SYSTEMS POLICY - NO UNPROTECTED PERSON SHALL KNOWINGLY BE SUBJECTED TO A HAZARDOUS ENVIRON- C MENTAL CONDITION DURING THE PERFORMANCE OF THE WORK ASSIGNED C - MAP 001554 LAM023431 V c v 9 RESPIRATORY SYSTEMS - RESPONSIBILITIES WHO DEPT., UNIT, OR CRAFT SUPERVISION SUPERVISORS OF PERSONS PERFORMING WORK REQUIRING RESPIRATORY PROTECTION c WHAT 1. INSPECT, EVALUATE EXPOSURE, SPECIFY EQUIPMENT 2. PREPARE AND MAINTAIN WRITTEN PROCEDURES 3. TRAIN EMPLOYEES KEEP RECORDS ON TRAINING c MAP 001555 LAM023432 V ( V 10 RESPIRATORY SYSTEMS - RESPONSIBILITIES MHG DEPT., UNIT, OR CRAFT SUPERVISION SUPVISORS OR PERSONS PERFORMING WORK REQUIRING RESPIRATORY PROTECTION WHAT 1. INSPECT EQUIPMENT KEEP RECORDS ON INSPECTION 2. REVIEW CHANGES IN SCOPE OF WORK FOR IMPACT ON PROTECTION REQUIRED 3. INSURE PROPER APPLICATION C MAP 001556 LAM023433 ( WHO < V v 11 RESPIRATORY SYSTEMS - RESPONSIBILITIES LOSS PREVENTION AND SAFETY (LP&S) WHAT C 1. WORK WITH SUPERVISION INSPECTION, EVALUATION, SPECIFY EQUIPMENT 2. PROVIDE EQUIPMENT TO UNITS REPAIRS, CLEAN, INSPECT, STERILIZE SEAL PACKAGE MASKS 3. TRAIN SUPERVISION USE, CARE, AND STORAGE 4. MAINTAIN LOG BOOK ON SELF-CONTAINED BREATHING APPARATUS MODEL SW CANISTER MASKS MAP 001557 C LAM023434 RESPIRATOR FITTING USER MUST TEST EACH TIME RESPIRATOR IS PUT ON USER MUST CHECK - POSITIVE PRESSURE TEST - NEGATIVE PRESSURE TEST - MOVEMENT CHECK - MANUFACTURER INSTRUCTIONS USER MUST WEAR AS DESIGNED - ALL PARTS IN PLACE - ALL PARTS PROPER POSITION - ALL STRAPS SECURE - NO MODIFIED STRAPS MAP 001558 LAM023435 RESPIRATOR FITTING PURPOSE OF PROTECTIVE EQUIPMENT ISOLATE WEARER FROM ATMOSPHERE REQUIRES LEAK-TIGHT SEAL BETWEEN MASK AND FACE MUST BE FREE OF FACIAL HAIR PROTRUDING INTO SEALING PORTION OF RESPIRATOR NOTE: A FIT TEST WILL NOT BE CONDUCTED ON ANYONE NOT MEETING THIS REQUIREMENT. MAP 001559 LAM023436 RESPIRATORY EQUIPMENT PROCEDURE UNIT AND CRAFT SUPERVISORS (INCLUDING P.T.) "KEEP CURRENT LIST OF PERSONS -REQUIRED TO USE RESPIRATORS -THOSE PERSONS TEMPORARILY NOT PHYSICALLY ABLE TO USE RESPIRATORS "UPDATE LISTS ANNUALLY OR WHEN OPERATIONS CHANGE KEY CONSIDERATION: WORK BEING PERFORMED NOT THE GENERAL LOCATION OF THE WORK MAP 001560 LAM023437 V c v 15 RESPIRATORY EQUIPMENT PROCEDURE USED EQUIPMENT RETURNED TO SAFETY SUPPLY FOR REPROCESSING DISPOSABLE DUST RESPIRATORS DISCARDED AFTER ONE USE GAS MASK CANISTERS PROPERLY IDENTIFIED SPECIFY PROTECTION C MAP 001561 LAM023438 16 c RESPIRATORY EQUIPMENT PROCEDURE PRESCRIPTION GLASSES/FULL FACEPIECES AVAILABLE ON REQUEST - LP&S OXYGEN DEFICIENT AND TOXIC ATMOSPHERE STANDBY REQUIRED C SUITABLE RESCUE EQUIPMENT REQUIRED STANDBY SOUNDS ALARM EQUIPMENT INSPECTION MONTHLY BY OWNING DEPT. SEMI-ANNUALLY BY SAFETY DEPT. MAP 001562 LAM023439 (n RESPIRATORY EQUIPMENT PROCEDURE WRITTEN PROCEDURES REQUIRED EMPLOYEES TRAINED BY SUPERVISORS EMPLOYEE DEMONSTRATES PROPER FIT PROPER USE GUIDES TO RESPIRATOR SELECTION & USE AVAILABLE FROM LP&S MAP 001563 LAM023440 V RESPIRATOR FITTING 13 IN AREAS HAVING ASSIGNED RESPIRATORS USER TESTED WITH RESPIRATOR ASSIGNED IF SPECIAL GLASSES ISSUED THEY WILL BE USED IN FIT TESTING DENTURES MAY SERIOUSLY AFFECT FIT MUST BE WORN DURING FIT TESTING AND USE c ADDITIONAL QUANTITATIVE FIT TESTING REQUIREMENTS WILL BE REQUIRED FOR ACRYLONITRILE EXPOSURE WHEN EQUIPMENT IS AVAILABLE c MAP 001564 LAM023441