Document baLQmwkeo7kMQqQEm8L0b7zy3

Air-Conditioning Young Radiator Company Dept. 545, Racine, Wis. Sales & Engineering Representatives in ail Principal Cities Heating, Cooling, Air Conditioning Products for Home and Industry, Heat Transfer Products for Automotive, Agricultural, Industrial, Gas and Diesel Engine Applications CONVECTORS & UNIT HEATERS Convectors are available from stock in six standard cabinet styles; also Insti tutional and bathroom models; for steam or hot water systems. "Vertiflow" Unit Heaters are built in seven models; capacities from 52,600 to^ 552,000 Btu per hr; adjustable louvers, nozzles, diffusers, Anemostats. ^Type "SH" Unit Heaters are built in m4 models; capacities from 19,000 to 325.000 Btu per hr; for steam and hot water systems. Cabinet Type Unit. Heaters are avail able in number of arrangements, wall^ hung, horizontally suspended, etc.; from 26,200 to 115,000 Btu per hr. "Perimaheat" Baseboard Convector for hot water service; available in 6 and 8 ft lengths; capacity with 190 deg average water 822 Btu per lineal foot; adjustable dampers (air splitter for use with ther mostatic controls, optional). Gas-Fired Unit Heaters are available in eight sizes ranging in capacities from 50.000 to 230,000 Btu/hr input. Have^ welded corrosion-resistant aluminized steel combustion chamber and heat ex-, changer; other important design features. Young manufactures a complete line of heating and cooling coils for central heating or cooling systems. AIR CONDITIONING UNITS Young "YAC" Air Conditioning Units provide year around service for cooling, heating, filtering, circulating, humidi fying and dehumidifying in any com bination. Units are available in nine sizes; capacities from 400 to 22,000 cfm; vertical (right) or horizontal types; HEATING & COOLING COILS wYoung "Roomaire" Cabinet Air Condi~tioner cools, heats, filters, circulates and dehumidifys one or two rooms--for use with chilled water systems. Available in 3 sizes with capacities of , 1 and 1-J^ tons. 1296 ^ fee?. *c. t: Air Conditioning , Unit Heaters ' Electric 45 Crouch St., Rochester 3, N. Y. Complete line of Electric Heating Systems For HOME, INDUSTRY, FARM The advantages of electric heat are well known. However, there is a great dif ference in the safety of electric heaters. Electromode has a completely sealed-in, cast-aluminum beating element which provides absolute protection against fire, shock, burn or explosion. This element acts as a superior heat diffuser, resulting in greater heating efficiency and economy. For Big Rooms -- For HOME and OFFICE -- Bathroom Small Room Fig. !. Pio- P'Q- 4 Electromodc Wall-type Heaters are made in models and capacities suitable for all size rooms, ranging from 1320 to 4000 watts, with built-in thermostat or manual con trol. Heat is fan-circulated at floor level. All have automatic thermal safety switch. The big room heaters have silver grey hammertone finish; small room or bathroom heaters are available in gleaming chrome or white enamel. See figs. 1 and 4- ELECTROMODE RADIANT HEATING ELECTROMODE BASEBOARD HEAT- PANEL combines radiant and convection ING provides low level perimeter heat heating. Modern design with silver ing. Endpieces and inside corners avail- grey hammertone finish. With or without able to make up system to conform to built-in thermostat. Capacity 1100 watts. room dimensions. Capacity: 600 watt See fig. 2. units, 120 or 240 volts. See fig. 3. ELECTROMODE RADIANT CABLE HEATING coils of Electromode Heating Cable hidden in the ceiling silently radiate clean, healthful heat downward. Each room tempera ture is controlled by separate thermostat. CableB are a meas ured length of specially constructed and insulated electric wires; waterproof and non-corrosive; embedded in standard plaster ceilings. Magic Seal, perfected by Electromode, pre vents streaks on ceiling. See fig. 5. F<*-5 For INDUSTRY UNIT HEATERS available in Suspension-type and Combina tion Portable and Suspension models. Capacities from 1500 to 45,000 watts. Ideal for auxiliary warmth in hard-to-heat areas and for complete heating in outlying buildings. Adjustable louvers for directing fan-circulated heat into working zone. Fig. 6.-- S'^ptnrion Thermostat control available on all models. See fig. 6 and 7. EXPLOSION-PROOF HEATERS for areas charged with inflammable vapors. Listed by Underwriters' Laboratories for Class 1-Group D Hazardous Industries. Convection type. Three models range from 2000 to 6000 watts. See Fig. 8. ELECTROMODE BLAST COILS consist of a bank of Electromode cast-aluminum heating elements mounted in a 16 gage pig s flans . formed steel frame having a 1) in. wide pletew"1- 'A6 *n- holes on approx. 6 in. centers for mounting to air ducts. Comdiagrams for special applications furnished on request. See Fig. 9. All cfu.ilil mode Heating Systems are approved by Underwriters1 Laboratories and are guaranteed. Cent'8' vrvr-n?^e'il gladly given. For more information, see your supplier or write >G-15, Electromode Corporation. 1297