r HEATINC VENTILATING AIR CONDITIONING GUIDE 1941 CHAPTER 3. HEAT TRANSMISSION COEFFICIENTS AND TABLES Table 3. Coefficients of Transmission (U) of Masonry Walls Coefficients ore expressed in Btu per hour per square foot per degree Fahrenheit difference in temperature between the air on the two sides, and are based on a wind velocity of 15 mph. TVPIPlT CONSTRUCTION TYPE OF WALL Thickness or Masonbt (Inches) Wau No. Solid Brick Based on 4-in. hard brick and the remainder common brick. 8 12 16 1 2* 3 Uninsulated Walls 1s 1 hoa c * c illSI5 g s 5*3 31 Ji 1 * Cu s 1 E* Mg Cm S Cu. &.S A B CD E Decorated building board (H in.) with out plaster--furred Plaster on metal lath attached to fur ring stripe (2 in.6)-- rock wool fill ( IH in.6)* INTERIOR FINISH Insulated Walls 5 Oa'--*-" 5-g gX|||3 Ta Ns]5 a. `"I "Si-- fil ii xrl til'd 2 ii!'T| llll Jj-L cux cmx. cu*cL om a. F GH i J K Ss^Il italfi L 0.30 0.32 0.30 0.24 0.25 0.24 0.28 0.27 0.20 0.21 0.20 0.23 0.19 0.17 0.22 0.16 0.19 0.14 0.16 0.13 0.14 0.12 0.11 0.22 0.18 0.16 0.12 0.11 0.10 0.20 0.17 0.15 Hollow Tile Stucco Exterior Finish. The 8-in. and 10-in. tile figures are based on two cells in the direction of flow of heat. The 12-in. tile is based on three cells in the direc- tion of flow of heat. The 16-in. tile consists of one 10-in. tile and one 6-in. tile each having two cells in the direction of heat flow. S 10 12 16 4 5 6 7 0l25 0.38 0.37 0.29 0.24 0.26 0.26 0.22 0.19 0.28 0.27 0.22 0.19 0.26 0.26 0.22 0.19 0.20 0.20 0.17 0.16 0.20 0.15 0.19 0.15 0.17 0.14 0.15 0.12 0.13 0.13 0.12 0.11 0.20 0.20 0.17 0.16 0.11 0.11 0.10 0.097 0.18 0.18 0.16 0.14 Limestone or Sandstone 88 12 9 16 10 24 11 0.71 0.58 0.49 0.37 0.64 0.53 0.45 0.35 0.37 0.33 0.30 0.25 0.39 0.34 0.31 0.26 0.37 0.33 0.30 0.25 0.26 0.24 0.22 0.20 0.25 0.18 0.23 0.17 0.22 0.16 0.19 0.15 0.15 0.14 0.14 0.13 0.25 0.23 0.22 0.19 0.13 0.13 0.12 0.11 0.23 0.21 0.20 0.18 Concrete (Monolithic) These figures may be used with sufficient accuracy for concrete walls with stucco exterior finish. Cinder (Monolithic) Conductivity k -- 4.36 Burned Clay aggregate (Monolithic) Conductivity r=> 3.96 Cinder Blocks Cores filled with dry cinders, 69.7 lb per cu ft. Cores filled with granulated cork, 5.12 lb per cu ft. Cores filled with rock wool, 14.2 lb per cu ft. Based on one air cell in direction of heat flow. Cores filled with granulated cork, 5.24 lb per cu ft. Concrete Blocks Cores filled with granulated cork, 5.14 lb per cu ft. Based on one air celt in direction of heat flow. Burned Clay aggregate Blocks Cores filled with granulated cork, 5.06 lb per cu ft. Burned Clay aggregate Blocks Cores filled with granulated cork, 5.6 lb per cu ft. Computed from factors marked by * in Table 2. 6 Based on the actual thickness of 2 in. furring strips. 84 6 10 16 20 6 10 16 20 6 10 16 20 8 8 8 8 12 12 8 8 12 8 8 12 12 12 13 14 15 0.79 0.62 0.48 0.41 0.70 0.57 0.44 0.39 0.39 0.34 0.29 0.27 0.42 0.37 0.31 0.28 0.39 0.34 0.29 0.27 0.27 0.25 0.22 0.21 0.26 0.19 0.24 0.18 0.21 0.16 0.20 0.15 0.16 0.15 0.14 0.13 0.26 0.24 0.21 0.20 0.13 0.13 0.12 0.12 0.23 0.22 0.20 0.18 16 0.46 0.43 0.29 0.30 0.29 0.22 0.21 0.16 0.14 0.21 0.12 0.19 17 0.33 0.31 0.23 0.24 0.23 0.18 0.18 0.14 0.12 0.18 0.11 0.16 18 19 0.22 0.22 0,17 0.18 0.17 0.19 0.18 0:15 0.15 0.15 0.15 0.13 0.14 0.12 0.10 0.13 0.11 0.09 0.15 0.13 0.09 0.09 0.13 0.12 20 0.44 0.41 0.28 0.29 0.28 0.21 0.21 0.16 0.13 0.21 0.12 0.19 21 22 0.30 0.29 0.22 0.23 0.22 0.21 0.20 0.16 0.17 0.16 0.17 0.14 0.17 0.14 0.12 0.14 0.11 0.10 0.17 0.13 0.10 0.09 0.16 0.13 23 0.17 0.17 0.14 0.14 0.14 0.12 0.12 0.10 0.09 0.12 0.08 0.11 24 0.42 0.39 0.27 0.28 0.27 0.21 0.20 0.16 0.13 0.21 0.12 0.19 25 0.31 0.29 0.23 0.23 0.22 0.18 0.17 0.14 0.12 . 0.17 0.11 0.16 26 ' 27 0.22 0.21 0.17 0.18 0.17 0.14 0.14 0.12 0.11 0.23 0.22 0.19 0.18 0.18 0.15 0.14 0.12 0.10 0.14 0.15 0.09 0.09 0.13 0.14 28 0.37 0.35 0.25 0.26 0.25 0.19 0.19 0.15 0.13 0.18 0.11 0.17 29 0.20 0.19 0.17 0.16 0.16 0.13 0.13 0.11 0.10 0.14 0.09 0.13- 30 0.56 0.52 0.32 0.34 0.32 0.24 0.23 0.17 0.14 0.23 0.12 0.21 31 0.41 0.39 0.27 0.28 0.27 0.21 0.20 0.15 0.13 0.21 0.12 0.18 32 0.49 0.46 0.30 0.32 0.30 0.23 0.22 0.16 0.14 0.22 0.12 0.20 33 0.36 0.34 0.26 0.26 0.24 0.19 0.19 0.15 0.13 0.18 0.11 0.17 34 0.18 0.17 0.15 0.15 0.14 0.13 0.12 0.10 0.09 0.13 0.08 0.12 35 0.34 0.32 0.25 0.25 0.24 0.19 0.18 0.14 0.12 0.18 - 0.11 0.17 36 0.15 0.14 0.13 0.13 0.12 0.11 0.11 0.09 0.08 0.11 0.08 0.10 *A waterproof (not vaporproof) membrane should be provided between the outer material and the insulation fill to prevent possible wetting by absorption and a subsequent lowering of efficiency* 85 S.