Document bOObGE9BdEX8jywe0LM96bNM6
..*v From
INTERNAL CORRESPONDENCE APRIL 3, 1964 -A4T7C
INDUSTRIAL HYGIENE COMMITTEE
To MR. W. F. KNEELAND
DAVENPORT WORKS
DAVENPORT WORKS
t/ o
CONFIDENTIAL
Mr. T. B. Bonney, Pittsburgh Dr. L. V. Cralley, Pittsburgh Mr. W. C. Harvey, Davenport Mr. J. H. Lowry, Davenport Dr. A. W. Shafer, Davenport Mr. B. D. Kent, Davenport Mr. Ron Small, Davenport Mr. G. J. Myers, Davenport Mr. C. L. Huey, Davenport Mr. B. T. Evans, Davenport Mr. J. 0. Vanest, Davenport Mr. G. H. Walter, Davenport
INDUSTRIAL HYGIENE COMMITTEE MEETING - MARCH 1964
The March meeting of the Davenport Industrial Hygiene Committee
was held at 12:30 p.m. March 25, 1964, in the small dining room of the
Main Cafeteria. Attending were the following: Messrs. J.'.O. Vanest,
B. T. Evans, W. C. Harvey, G. J. Myers, B. D. Kent, J. H. Lowry, and
Dr. A. W. Shafer.
'
No further revisions have been made to the existing duct system of
the 2020 furnace in Remelt since this system is being redesigned.
The Skim. House -fan is now installed. The noise problem in the
#8 DC Pit Area remains unchanged.: It was suggested that ear muffs be
recommended for the Scalper Area personnel unless the problem is solved
within the next three or four weeks.
:
'i
.
Weights have been added to the side plates of the 125 Horsepower
Motor in the Plate Mill and as a result the noise has dropped to a safe
level
__ ,i.
W"
r 4M)
PRINTED IN U.S.A.
ARD 044149
Tw>_iL* ?_
_________________________date.April _3, 1964,,.;; sheet no,
-2-
The air knives on #4 and #7 Cold Mills are now using low pressure blow offs and the indication is that this arrangement will be used in the Foil Mill.
Noise problems in the #5 stand area of the Continuous Mill, the Foil Mill Trimmer and Foil Mill heat treat area remain as problems to be investigated by the Engineering Division.
Graphs of noise level readings are to be submitted to and maintained by the Chairman of the Industrial Hygiene Committee.
Further trials are to be made of the Lomb Air Mover. The Air Mover worked very well in removing oil mist and in drawing cooler air
into the #4 Mill Morgoil Tank. In the #7 Cold Mill Tank, fumes w.ere
removed but were recirculated back into the tank because no doors were
opened to admit fresh outside air.
*>
Some work has been done for collecting dust when sawing marinite
in the Carpenter Shop. However, further work is held up pending
decisions for a final location for sawing this material.
A study of the paint fume problem in the Faint Line Coater House
is underway. It is hoped that this problem will be solved by the April
meeting.
Four catalytic attachments are on order for the exhausts of the trucks in the loading area to reduce a CO problem found inside transport
truck vans.
The Chairman appointed a committee to investigate the large number
of tanks and manholes which will require testing before permitting
.
entrance by any of our employees
9. r. IStS.ISOM^.87 . PftlNTCO (N U. 9. A.
ARD 044150
to------- Mr^-W.--
..April .3.,_19.64.__ ___ Sneer No.............. .3-
The Committee consists of B. D. Kent, Chairman; Dr. A. W. Shafer, Messrs. C. L. Huey and J. H. Lowry. It was re-emphasized that the foreman or supervisor of the project was responsible for notifying the Laboratory or Pyrometric Department for testing before entering hazardous areas.
The Committee appointed to investigate the audiometric program reported on their findings via attached report by Dr. Shafer.
WCH/JHL:kk Attachment
\ :: : ; 5 .
s'
' j--'-'" '
W. C. HARVEY J. H. LOWRY
t. t. tl.|S0M.4-S7 PftlNTCD IN U. S. A.
' - w ' * ':i '
'.
'
-
t ti
'v
j * .! . ' .
i
.. -. .. .
i-
i >. "V;'
`
'
. .
.
. .
.
>.,|
..
w
: i *
)
;>
ARD 044151
K-'
;
.*
h
l
/- -
. ''
INTERNAL. CORRESPONDENCE
March 20, 1964
From A. V. SHAFER, M.D.
To MR. W. C. HARVEY
MEDICAL DEPARTMENT
INDUSTRIAL HYGIENIC COMMITTEE
RE: RECOMMENDATIONS REGARDING HEARING CONSERVATION PROGRAM
The aims of a hearing conservation program, the need for
such a program, a suggested method of initiating and implementing
it, and a few of the benefits to be expected from Bame are outlined
below:
I. Aims:
A. Prevention of hearing loss by:
.
1. An in the mill noise survey program coupled with
action to reduce noise in areas where it is a
potential problem, or enforcement of rules regard
ing the use of proper ear protection if this is
'
more practical. Steps in this direction have been
taken.
>
2. To find noise susceptible individuals and take
'
action to prevent hearing loss.
B. Provide permanent records for reference Bhould we be faced
with a hearing loss claim.
1. Noise survey record.
2. Individual Audiometric record.
C. To aid in placement of employees according to their hearing
ability. A partially deaf person may be a valuable employee,
' but present a safety hazard in some areas.
D< To complement our physical examination program. * ; * : ' '
PMINTKO IN U.S.A.
ARD 044152
II. Need
A. As outlined .in the alas of a hearing conservation program
prevention of hearing loss is important to the employee
and the Company.
B. Recognition of hearing loss at the time of employment is
important because it makes it a matter of record.
C. Compensation laws in Missouri, New York, and Wisconsin
contain provisions dealing specifically with compensation
for gradual loss of hearing. Thirty states, including the
three above, provide full occupational disease coverage and
awards have been made for what is termed "gradua1-injury".
Alcoa has had 30 hearing loss claims at Vernon, one at
.
Edison and one at Bauxite, which have averaged over $2,000.00
each. There may be more of which I am not aware. The AFL
CIO has thru their representatives suggested language for
insertion into the Walsh-Healy Act specifically dealing with
noise control, noiBe level.limits, audiometry and hearing
conservation.
Thus far Iowa has had very few compensation cases involving
hearing loss. According to Mr. C. H. Greenley, Deputy Industri
al Commissioner, the few that have taken place have been settled
amicably without a hearing, excepting the one case noted in the
Code. A man's ability to recover for a hearing loss in Iowa
would not be limited to his having been exposed to a single
traumatic incident such as a blow on the head or explosion.
The-maximum loss of hearing due to industrial Injury would be
equal to 175 weeks compensation ($6,500.00). Mr. Greenley be-
ARD 044153
3
lieves that Waivers on people with significant hearing loss
would be advisable for both employee and employer.
-
C. I predict that Iowa will someday be forced to legislate pro
visions into its Workmen's Compensation Law dealing with
hearing loss. With enactment of such legislation we will be
facing many unjustified compensation claims unless we are in
a position to defend ourselves with appropriate records.
III.' Initiating & Implementing the Program:
A. In the mill noise survey:
A "go or no-go" type of survey meter has been acquired and
is in use. Its continued use, and maintenance of a permanent
record of findings should be kept. A duplicate record of
these findings should also be on file in either the Medical
or Safety Department.
*
B. In areas where noise is a potential problem action should be
taken to bring the noise to safe limits if this is feasible,
,
or to insist on adequate ear protection for employees if
necessary.
C. An audiometric program should be initiated with an audiometric
examination being made a part of all pre-employment examinations
and as experience dictates a part of our periodic physical exam-
inatlon program. This will require the acquisition of an Audiometer
and a sound attenuating booth for audiometric testing. Our medical
technicians will need training in audiometry so that results of
our examinations will not be challenged. Records of audiometry
should be made a part of the employee's medical record.
ARD 044154
4
IV. Cost o the Audiometric Program:
A. Audiometry equipment and installation:
1. A copy of the Maico representative's proposal and
quotation of prices for audiometer and booth is en-
closed. After careful study of available booths
and audiometers, I feel that the equipment listed
- in this quotation fits our needs.
. 2. Installation of this equipment will require one super
. visor and two hourly men about one day. Electrical
connection will be needed.
B. Each audiometric- test done should take about five minutes
; time.
'
' C. Maintenance of records will add a minimal burden.
D. Training of technicians:
1. Instruction in use of equipment and basic audiometry will
- be furnished by Maico representative free of charge.
. 2. Further training under Dr. James Curtis at the State
University of Iowa has been advised by Tom Bonney and
V .,
-
-
: would require one week's time for each trainee.
AWS:ep
-H
Enc. . Copy of Maico representative's proposal..
: -..:r
ARD 044155
TRI-CITIES HEARING AID CENTER
BRUNO LARSON
. . . . TBLBPHONB 323-5330 March l6, 19.64
I
602 Davenport Basic Building DAVENPORT - - IOWA
Dr. Arthur W. Shafer, Medical Director, Alcoa, Davenport Works, Riverdale, Iowa.
'
..
. ,,
.
Dear Dr. Shafer:
'
This will confirm our telephone conversation as of this date, regarding the delivery
f.o.b. Davenport of the following equipment:
.'
1 Sound Proof Room known as 402M --
Forced Ventilation
*
.
1~ Maico MA-2 Audiometer
",
Met price to you $2688. The inside dimensions of this Sound Proof Room are
72" x 64" x 78*.
; I might mention here that the quoted price of the 402M is $2045.00.
':
The Ventilation Unit
285.00
The Maico MA-2 Audiometer
358.00
1 .and the quoted price from the Eastern Express
4000 pounds to Davenport
142,40
for a total of I am quoting you a net price of $2688, . .
$2830,40
ARD 044156
I would like to point out too that we supply loaners at no charge. When, if and
ever an audiometer should have to go in for repair and recalibration, the present prevail
ing price for repair and recalibration of the MA-2 is $50,00. I am enclosing a sheet show
ing the complete job that*s done on each,audiometer and the Maico factory give a six month's
repair guarantee,
-
..
.
EL: ms Enc.
ERLIN0 LARS01