Document bNB3jevBG3Gk1ndOrxMeqV10
Training & Development Procedures
Chlorinated Methanes
CMP PROCEDURE
fSA SYSTEM. START UP PROCEDURE # 460124
PURPOSE
To supply the operator with the necessary information required to start up this system.
SCOPE
To list the items for each step of the start up
RELATED PROCEDURES
Vacuum compressor line up and start up procedure.
DEFINITIONS
Analyzer = Measures the amount of organics in the vent stream to ^
atmosphere. MOD V = This systems computer controller. PS Alarms - These are MOD V diagnostic alarms.
SAFETY CONCERNS & EQUIPMENT
ENVIRONMENTAL CONCERNS
Standard block safety equipment Refrigerant leaks
SPECIAL CONCERNS Ensure that PVRV's and ERV's are properly operating on all API tanks to the PSA system.
PRE START UP
Revision# .
Dow Confidential
Revision Date-
This procedure is valid for 24 hours from the date viewed, July 7,1993,8:43 AM
OONFTDFNTTAI
DO 009082
Training & Development Procedures
Chlorinated Methanes
PSA SYSTEM START UP PROCEDURE
Step
Action
1 Make sure the refrigeration compressor is running.
2 Make sure analyzer on vapor outlet line is in working order.
3 Line up all instrumentation on PSA system. Check the air supply to all instrumentation.
4 Line up the vacuum pump.(man. blk valves & switch) (SEE K-1750/1760/1770 LINE UP PROCEDURE)
5 Line up freon control valves
6 Line up all instrumentation and the N2 control valves on the check tanks for this system. Check the air to all instrumentation.
GR, revised 11/92
CONFTDFNTTAI DO 009083
Training & Development Procedures
Chlorinated Methanes
PSA SYSTEM START UP PROCEDURE
MOD V SYSTEM CHECK SHEET
Step
Action
1 Make sure the GPI system working properly
2 Make sure all the manual disconnect switches are in their correct position
3 Make sure all the lamp bulbs on the MOD V working properly
4 Are there any (DS) alarms on (if so check out and call hardware personnel)
5 Make sure at least one MOD V computers running
6 Make sure the MOD V printer is working properly
7 Have all alarms been cleared
8 Make sure the abort key in its proper position
9 Make sure all control valves and instrumentation are in the automatic position on the mod. Make sure that the following (AK'S) and (AP'S) have the con-ect setpoints.
10 Once the outside is lined up and this check sheet is complete proceed to the start up procedure
GR, revised 11/92
OONFTDFNTT At
PSASU.DOC
DO 009084
Training & Development Procedures
Chlorinated Methanes
PSA SYSTEM START UP PROCEDURE
START UP PROCEDURE
Step
Action
1 Terminate to Draper step . (WE ARE STARTING UP ON N2 ONLY)
2 Monitor the freon control system to the freon exchanger. Make sure all parameters and controls look good.
3 Adjust the pressure on the freon exchanger to control the drain temperature at approx. -4.5 deg c
4 When the freon exchanger control system pressure and temp look OK, you can terminate the step.
5 The PSA system will begin its cycling of the beds.
GR, revised 11^2
OONIFTDFNTTAI
PSASU.DOC
DO 009005
CHLORINATED METHANE PRODUCTS COMMUNIQUE'
Rev. 7/19/93:jpw
K DOW CONFIDENTIAL
DO 009086
Training & Development Procedures
Chlorinated Methanes
CMP PROCEDURE PSA SYSTEM SHUT DOWN
PROCEDURE # 460125
PURPOSE
To provide the operator with the necessary information needed to guide them through a PSA system shutdown
SCOPE
To list the necessary items to properly and safely shut this system down
RELATED PROCEDURES
Vacuum compressor shut down procedure
DEFINITIONS
SAFETY CONCERNS & EQUIPMENT
Minimum block safety
ENVIRONMENTAL CONCERNS
Shutting the PSA filter beds down may cause and noncompliance for the check tanks that vent to this system
SPECIAL CONCERNS
NOTE: IF THE ENTIRE PSA SYSTEM IS GOING TO BE
DOWN. CONTACT THE PROPER ENVIRONMENTAL
CONTACTS.
OONFTDFNTTA!
"
Revision# .
Dow Confidential
Revision Date-
This procedure is valid for 24 hours from the date viewed, July 7,1993, 8:44 AM
DO 0090R7
Training & Development Procedures
Chlorinated Methanes
PSA SYSTEM SHUT DOWN PROCEDURE
PROCEDURE
Step
Action
1 If you are in one of the normal run/cycle steps, you will have to move to one of the recharge steps.
2 Once you are in the recharge step you have to move back to the fill exchanger step 302/332/432
3 From the fill step, move back up into the process wait step, and then to the maintenance wait step.
4 Manually block in and isolate all appropriate valve associated with this system. Get system ready for maintenance.
CONFTDFNTT A!
PSASDDOC
DO 009088
CHLORINATED METHANE PRODUCTS COMMUNIQUE'
DO 009089
Training & Developmenl Procedures
Chlorinated Methanes
CMP PROCEDURE PSA SYSTEM EMERGENCY (HIGH BED TEMPERATURE)
PROCEDURE # 460126
PURPOSE
To provide the operator with a document which will assist the operator during an exothermic reaction in the filter beds
SCOPE
RELATED PROCEDURES DEFINITIONS
To provide the operator with the information necessary to properly shutdown the PSA system in the event we get a high bed temperature alarm, it may be necessary that we shut the PSA_svstenutQwn and purge with N2. This situation could occur if the bed gets saturated with organics.
PSA purge procedure
i2_= Nitrogen Inert = A compound that has no reactivity.
SAFETY CONCERNS Required: Minimum block standards & EQUIPMENT
ENVIRONMENTAL CONCERNS
Environmental Release. If the entire PSA system is down, tank vents will release to atmosphere via PVRV. This contention is based on the tank vent pressure control valves being closed.
SPECIAL CONCERNS
This situation needs to be handled as soon as it is observed to prevent damage to equipment.
Ensure the wet vent does not back flow into the bed.
CONFTDFNTTAI.
Revision # .
Dow Confidential
Revision Date-
This procedure is valid for 24 hours from the date viewed, July 7,1993, 8:44 AM
DO 009090
Trainin & Development Procedures
Chlorinated Methanes
PSA SYSTEM EMERGENCY (HIGH BED TEMPERATURE)
PROCEDURE
Step
Action
1 If you are in the normal run step you will have to move to the "recharge" step which takes the hot bed offline.
2 Purge nitrogen through the hot bed using the nitrogen control valve. Discharge the nitrogen from the bleed located on the inlet piping to the bed. Tubing must be run to the wet vent from the bleed.
3 Begin N2 purge and hold until temperature has decreased.
GR 11,92
CONFTOFNTTAl
PSAHOTPRO
DO 009091
CHLORINATED METHANE PRODUCTS COMMUNIQUE'
Rev. 7/19/93 :jpw
DuW CONFIDENTIAL
DO 00909?
Training & Development Procedures
Chlorinated Methanes
CMP PROCEDURE K-1750/1760/1770 START UP PROCEDURE
PROCEDURE # 460133
PURPOSE
To provide the operator with the necessary information needed to safely and properly line up and start up the compressor.
SCOPE
To list step that are required to safely and properly line up and start up the vacuum compressor.
RELATED PROCEDURES
DEFINITIONS
PSA start up None
SAFETY CONCERNS & EQUIPMENT
Wreck The Compressor Minimum Block Standards
ENVIRONMENTAL CONCERNS
None
SPECIAL CONCERNS None
CONFTDFNTT Al
Revision# .
Dow Confidential
Revision Date-
This procedure is valid for 24 hours from the date viewed, July 7,1993, 8:50 AM
DO 009093
Training & Development Procedures
.Chlorinated.Methanes
KtJLZ50/1760/1770_STAKT_UP_PRQCEPURE
PROCEDURE
Step
Action
1 Open the suction & discharge manual block valves to the compressor
2 Check the oil level in the sump. If it is low, add oil prior to the start up. (MAKE SURE THE MANUAL VALVES TO THE MAGNETIC LEVEL INDICATOR ARE LINED UP)
3 Make sure the drain valve on the oil sump is closed and bull plugged.
4 Open all valves to the operating panel gauges.
5 Make sure that both suction strainer valves to the oil pump are lined up to the same position.
6 Place the ON/OPT switch to the (ON) position. This will allow the machine to be started by the MOD.
7 Rack in the compressor in the motor control center.
8 Once the machine is running, check for leaks.
9 Check the operating temperature. If the operating temperature exceeds 200 Deg F.(93 C), check the cooling system. The normal operating temp is 130 Deg F (54 DegC).
GR 10/91
CONFTDFNTT Al.
K1760SUIXX ,v;
DO 009094 CONFTDFNTT Al