Document bDG1BdypjZNMMbY0gXzL1VL3
Inter Office
Personnel end Organization Staff April 2, 1981
Mr. K. L. Adams, Manager Cleveland Engine Plant6
cc E. F. Arscott, M.D J. E. Fisher V. R. Kyle
R. J, Manthey J. E. Senterfitt
Subject! Asbestos Ambient Air Monitoring - Cleveland Engine Plants
As requested by Manufacturing Staff, air samples were taken at the Cleveland
Engine Plants on February 25, 198l to evaluate asbestos in air concentrations
at locations reported to Manufacturing Staff as using asbestos. The areas
evaluated included heat treat in Department **690 at Plant No. 1 and Tocco
camshaft hardening in Department 4976 at Plant No. 2. The use of asbestos
insulating materials was reported in both of these departments, but only a
few small aBbestos gaskets were observed.
,
The permissible occupational exposure limit (PEL) for asbestos is 2.0 f/cc, and the action level for medical monitoring iB 0.1 f/cc. As can be seen from the attached data sheet, none of the results of the air samples taken exceeded or neared the PEL or action level. Therefore, we plan no further evaluation relative to this subject at the Cleveland Plants.
jb Attachment
H. B. Lick, Senior Industrial Hygienist Industrial Hygiene & Toxicology Department Employe Health Services
BOOS 0638 SCF-FORD-3079
ppriniTrun dv poor*
INDUSTRIAL HYGIENE SERVICES SECTION INDUSTRIAL HYGIENE & TOXICOLOGY DEPARTMENT
'EMPLOYE HEALTH SERVICES
Cleveland Engine Plants 1 and 2 ' Departments 4690 and 4976
February 251 1981
PERMISSIBLE OCCUPATIONAL EXPOSURE LIMIT FOR AIRBORNE CONTAMINANTS:
Contaminant
Permissible Exposure Limit in f/cc*
Asbestos
2.0
* f/cc = Fibers of asbestos per cubic oentimeter of air.
RESULTS
Location/Conditions
Airborne Asbestos Concentration in f/cc
Cleveland Engine No. 1, Dept. 4690 - Metal Stamping General Area Air Sample, near Column BB5 next to furnace 902 General Area Air Sample, near Column BB6 at control panel
<0.01 <0.01
General Area Air Sample, near Column BB7 at panel for vest fan
<0.01
Cleveland Engine No. 2, Dept. 4976 - 351 Camshaft Hardening General Area Ai? Sample, near Column C-26 General Area Air Sample, near Column D-26
< 0.01 < 0.01
DATA RETRIEVAL NUMBERS: HBL 1193 - 1197
INSTRUMENTATION AND ANALYSIS:
Bendix BDX pumps with Milipore Type AA, 0.8 u membrane filters. Fibers counted using 430 x Phase Contrast microscopy.
ANALYST: L. Latorre, Senior Industrial Hygienist.
fo-.o /otc'; cc'pany
Indwlrkl
: ' ' -/
/cc . . ' ..
- -1 .1 .**
8005 0639 pootv men pv cncn