Document bBw2p6nMDVmD37xb87owkq2p0
INSPECTION REPORT
NESHAP 6C: Gasoline Dispensing Facility Inspection
Attached please find the United States Environmental Protection Agency's (EPA's) inspection report of your inspected facility and/or any related fuel delivery inspections identified therein. EPA is providing this report as a matter of agency policy and will contact you again only if needed.
Without making a determination that your business or organization is a small business, EPA is also providing you with a link to this Small Business Resources Information Sheet (https://www.epa.gov/compliance/small-business-resources-information-sheet) which provides an array of resources to help small businesses understand and comply with federal and state environmental laws.
Inspection Information Inspection Number: Inspection Date(s):
Regulatory Program(s):
EPA Region/Program Conducting Inspection:
Company Name: Facility Name:
Facility Physical Location:
R8_CAA_2025_0626_003
6/26/2025 40 C.F.R. Part 63, Subpart CCCCCC - National Emission Standards for Hazardous Air Pollutants for Source Category: Gasoline Dispensing Facilities (NESHAP 6C) EPA Region 8, Enforcement and Compliance Assurance Division, Air and Toxics Enforcement Branch Circle K Stores, Inc.
Circle K #2703291
6135 N Carefree Circle, Colorado Springs, CO, 80922
Chris Andrade Field Inspector Name
Inspector and Approval
Inspector Title
CHRISTOPHE CHRISTOPHER ANDRADE Digitally signed by R ANDRADE -06'00' Date: 2025.09.05 14:04:10
Signature
Scott Patefield Name of Approving Official
Branch Manager Title
Digitally signed by SCOTT
SCOTT PATEFIELD PATEFIELD
Date: 2025.09.05 11:30:24 -06'00'
Signature
FACILITY INSPECTION DETAILS AND OBSERVATIONS
General Facility Information
Gasoline Dispensing Facility Facility Name: Circle K #2703291
Parent Company Name:
AIRS-ID: 041-2195
Primary Facility Representative &
Title:
Facility Contact Phone/Email:
Kyle Kobashi, Environmental Compliance Specialist - Rocky Mountain
kyle.kobashi@circlek.com
CAA Permit (if any):
On-site Facility Representative &
Title:
Circle K Stores, Inc. Permit Exempt Number 21EP05245S.XP
Dee T., Sales Lead
Facility Address: 6135 N Carefree Circle, Colorado Springs, CO 80922
Enforcement and Compliance History:
None
Fuel Delivery Company Company Name: Trucking Circle K Stores, Inc.
Truck Identifier:
Fuel Supply Company
Representative & Title:
Fuel Supply Company Contact
Phone/Email:
43100
Jordan Kingery, Fuel Manager - Rocky Mountain Business Unit
jkinger@circlek.com
Trailer Identifier: 3416 Driver Name: Eric Holmes
Company Address: Fuel Supply 5500 S Quebec St., Suite 100, Greenwood Village, CO 80111
Enforcement and Compliance History:
None
Page 2 of 6
Inspection Number/ID: Inspector(s): Time Inspector
Presented Credentials: Permission to Enter Facility Granted? If Yes, by whom? If No, explain. Photographer Name:
Inspection Narrative:
Areas of Concern:
General Inspection Information
R8_CAA_2025_0626_003
Inspection Date
Katelyn Bergl (EPA) Alyson Skeens (EPA) Chris Andrade (EPA)
Arrival/Departure Time
6/26/2025 9:56 AM
10:46 AM
10:00 AM
Announced Unannounced
Yes No
Administrative Inspection Items:
CBI Procedures Discussed SBREFA Form Provided
Dee T., Sales Lead
Other materials or compliance assistance provided (describe):
Katelyn Bergl (EPA)
See APPENDIX A:
Alyson Skeens (EPA)
Photograph Range: Photograph and Video
Chris Andrade (EPA)
Log
The facility was inspected under the Clean Air Act (CAA) for compliance
with 40 C.F.R. Part 63, Subpart CCCCCC - National Emission
Standards for Hazardous Air Pollutants for Source Category: Gasoline
Dispensing Facilities (NESHAP 6C). Inspection activities included
observation of a fuel delivery event by the EPA inspectors and a request
for records required to be maintained under NESHAP 6C.
The following are areas of concern identified during the
inspection or records review:
1. Components of the tank and associated vapor equipment were not
vapor tight during the fuel delivery event, as required by Item 1(b) of
Table 1 of NESHAP 6C. The following emissions were observed
during the fuel delivery portion of EPA's inspection:
a. Gasoline vapors at concentrations above the lower explosive
limit (LEL) of propane were observed from the vapor recovery
hose during premium fuel (PUL) fueling.
b. Standing water in the PUL vapor recovery spill bucket may
have caused a malfunction in the poppet valve sealing
mechanism for the vapor recovery pipe adapter. An audible
continuous hiss indicated that the valve was not forming a
proper seal. During the inspection, the fuel truck driver
removed some liquid from the spill bucket readjusted the
poppet valve. The hissing sound stopped after this adjustment.
Page 3 of 6
Gasoline Throughput and Testing Records Applicable Throughput Category:
Calculated based on volume of gasoline Calculated based on volume of gasoline
loaded into all storage tanks
dispensed from all storage tanks
<10,000 gallons per
10,000 gallons per month and <
100,000 gallons
month
100,000 gallons per month
per month
Based on records provided since 2020, the
Date Applicable Throughput Category facility exceeded the 100,000 gallons per month
Was Exceeded: throughput threshold on or before January
2020.
Records: All Facilities regardless of throughput
Notes
5-Year Throughput Records Throughput records for this facility from January 2020 -
Available (5-year records must be
maintained and made available within 24 hours of request)
June 2025 were provided via email by Kyle Kobashi on June 24, 2025.
Last 12-month rolling throughput calculation
Provided along with 5-year throughput records
Records: Facilities 100,000 gallons per month
3 -year Leak Rate and
Cracking Pressure Test (CARB
Test Procedure TP-201.1E, - Leak Rate and Cracking Pressure of Pressure/Vacuum Vent Valves, or equivalent)
Static Pressure Test (CARB
Test Procedure TP-201.3, - Determination of 2-Inch WC Static Pressure Performance of Vapor Recovery Systems of Dispensing Facilities, or equivalent)
Date of Last Test:
Date of Last Test:
5/14/2024 5/14/2024
Notes
Results of Last Test:
Pass
Report Provided: Yes
Results of Last Test:
Pass
Report Provided: Yes
Fuel Delivery Truck Compliance (Gasoline Cargo Tanks under NESHAP 6C)
Fuel Type: 1) Regular Unleaded (RUL) 2) Premium
Amount of Fuel 1) 7,000 gallons Delivered: 2) 2,000 gallons
Annual Certification Test - Vapor Tightness Testing -
EPA Method 27 of appendix A-8 to part 60 of CAA
Available with truck
Date of Last Test: 2/12/25
5-Year Test Record Availability:
Available at office or central loc. Not Available
Other:
Results of Test: Pass
Pressure Change, p:
Vacuum Change, v:
Pass, -0.75 Pass, -1.00
Page 4 of 6
Fuel Delivery Event Observation:
A fuel delivery event was observed by the EPA inspectors. The inspectors used a forward-looking
infrared (FLIR) camera to record optical gas imaging (OGI) videos of gasoline vapors, and a toxic
vapor analyzer (TVA) to measure gasoline vapor concentrations1. Any auditory, visual, and
olfactory (AVO) observations were also recorded. See Appendix A for a list of photographs and
videos recorded during the fuel delivery inspection.
Components of the refueling activity
Description/Observations (including any OGI or AVO
which were observed:
observations)
Equipment was observed to be capped and covered
prior to fueling.
Standing liquid was observed in the PUL vapor recovery spill bucket and may have caused a malfunction in the poppet valve sealing mechanism for Conditions of Equipment the vapor recovery pipe adapter. An audible continuous prior to refueling event hiss indicated that the valve was not forming a proper seal. See Img_0294-0295. During the inspection, prior to re-fueling the tanks, the fuel truck driver removed some liquid from the spill bucket and readjusted the poppet valve. The hissing sound stopped after this adjustment. See Img_0296. Standing liquid was also observed in the RUL fuel spill bucket.
The vapor recovery hose was first connected to the Connection of fuel and vapor vapor recovery tank and truck header. Next, the fuel
lines prior to fuel transfer hose was connected to the fuel pipe of the tank, and finally the fuel hose was connected to the truck header.
During fueling of the PUL tank, gasoline vapors were
observed with the FLIR and TVA. The vapors were
Maintenance of fuel and
observed to be coming from the vapor recovery hose, near the interface of the hose and the vapor recovery
vapor line connections during elbow. See FLIR0052. The vapors were measured with
fueling event
the TVA, and a concentration of 33,700 parts per
million (ppm) as propane, or 3.37%, was recorded. This
concentration exceeds the LEL of propane of 2.1%.
Hoses were disconnected in the opposite order for
which they were connected.
Disconnection of fuel and vapor lines after fuel transfer After disconnecting hoses, a reading of 3,000 ppm as
propane was observed at the premium vapor bucket
with the TVA.
Conditions of Equipment after refueling event Caps and covers were returned after fueling.
1 The TVA was calibrated using 500 parts per million (ppm) and 10,000 ppm methane gas standards. The methane concentrations recorded on the TVA were then converted to a ppm concentration as propane using a conversion factor of 3. This provides a conservative conversion to propane, using the guidance put forth in EPA's "Frequently Asked Questions (FAQ) for Method 25A". See https://www.epa.gov/sites/default/files/2016-08/documents/method25a_faq.pdf.
Page 5 of 6
Documents Requested
Document(s)
5-year fuel throughput records including previous 12-month fuel throughput calculation
EPA Method 27 for the fuel delivery truck
Most recent NESHAP 6C Performance Tests
Document(s) Provided Will Provide After Inspection
Document(s) Provided Will Provide After Inspection Document(s) Provided Will Provide After Inspection
Status
Document(s) Denied Other (see notes)
Document(s) Denied Other (see notes)
Document(s) Denied Other (see notes)
Notes/Comments
APPENDIX A: Photograph and Video Log
File Name
Description
FLIR0052.mp4 Emissions from the premium vapor line hose
Img_0294.heic Img_0295.mov Img_0296.mov
PUL Vapor recovery pipe. Spill bucket has accumulated liquid, and the spring mechanism on the poppet cap is malfunctioning, staying in the lowered position without the vapor recovery hose attached and allowing vapors to enter or exit the tank. PUL Vapor recovery pipe. Spill bucket has accumulated liquid, and the spring mechanism on the poppet cap is malfunctioning, staying in the lowered position without the vapor recovery hose attached and allowing vapors to enter or exit the tank. Air intrusion into the pipe is audible in the video. PUL Vapor recovery pipe, after the delivery driver removed some liquid from the spill bucket. He also adjusted the poppet spring to attempt to return it to a sealed position, and the hissing noise was no longer audible.
Photographer C. Andrade K. Bergl
K. Bergl
K. Bergl
Page 6 of 6