Document bBewzZ0KKR5M47anBx8pDEQOo

jollob Analytical Service Corp Mass Spectrometry Gas Chromatography Leak Detection Mr. . Borch Amboy Terminaling Company 560 State Street, Perth Amboy, New Jersey 08861 47 INDUSTRIAL. ROAD BERKELEY HEIGHTS. NEW JERSEY 07922 TEL. (201) 464-3331 ANALYTICAL REPORT_ NO_. 34575 RMvrBed Report MATERIAL SUBMITTED* Date Reported: Date Requested: P.O. No. Monitoring at Amboy Terminaling. 10/14/75 10/2/75 Verbal INFORMATION REQUESTED: Ga3 Chromatography Analysis. NOTEBOOK REFERENCE: NB 347 page 93. RESULT OF INVESTIGATION: On September 30, 1975, Mr. J. Traina of G,A.S. visited Amboy Terminaling and monitored one employee and the Ware-- house Area for vinyl chloride monomer. This was the first test performed since the installation of the new ventilation system installed in September. All data are presented in the attached table. This report revised to include box changes and the type of material being bagged. * Continued RNW 3548 By. GOLLOB ANALYTICAL SERVICE CORP. Hr. B. Borch Anboy l'erminaling Company -2- Employee and/or Tiraa Area Monitored (Hours) M. Mizerak-PacXaging 5rP 15% - ZO-fs73 Room # 1 8:42 - 9:25 9:45 - 11:13 Material QSQ F7 11:15 - 11:30 11:34 - 11:55 Box changed 12:30 12:44 - 1:06 1:09 - 2:34 Box changed 9 3:30 2:37 - 3:55 8 Hour Time Weighed Average - O.A.S. # 34575 Revised Reoort Vinyl Chloride Monomer Concentration pom Voluae/Volumt .46 .30 .81 .60 .42 .51 .47 .45 Warehouse A Front of Bay 645 8 Hour Average Aisle 500 Bays 545-581 3:24 - 9:52 9:57 - 11:41 11:45 - 1:13 1:17 - 2:45 2:49 - 4:20 10:05 - 10:20 .51 .81 1.8 4.6 3.7 2.2 3.7 Aisle 500 Bays 500-545 1:23 - 1:38 4.6 Note: All samples were collected on NIOSH approved charcoal tubes using Sipin pumps. i v ach 10/15/75 RNW 3549