Document bBJZnm6ZqqyE5GL9RLLqnJ0BZ
ABD00088924
Name: Wi1 son Next test due:
TSI MODEL 8015 PORTACOUNT FIT-TESTING SOFTWARE Version 2.01 S/N 927 VISTA POLYMERS
FIT TEST REPORT
Test date: Test time: Test subject last name: Test subject first name: ID number: Operator name: Next fit test due: Test agent: Test device:
08-09-1994 8:06:01 am
Wilson Andy 587729319 H Pruitt
Ambient particles TSI MODEL 8010 PORTACOUNT
RESPIRATOR ID Size:
Model: Manufacturer: Approval number:
Sma 11 U1travue Facepiece TC-19C-113
Additional notes: Additional notes:
TEST DATA
Ex.
Ambient (Part/cc)
Pass/Fail level: 100
Test cycles....: 1
Mask
Fit Factor
(Part/cc)
Pass/Fail
NB 9375 DB 9485 SS 9735 UD 9690 R 9450 NB 9335
0.580 2.390 0.300 0.890 0.940 0.140
16100 3970
32400 10800 10000 66700
PASS PASS PASS PASS PASS PASS
OVERALL FIT FACTOR = 10861 (Calculated per ANSI Z88.2-1980)
PASS
Operator____ Test Subjec
Date
T<-
Date 0/f/fY