US REGULATIONS (Continued)
EXPOSURE LIMITS AND MONITORING Permissible Exposure Limit (PEL) -0.1 f/cc for an 8 hour time-weighted average Excursion Limit (EL) -1.0 f/cc for a 30 minute time-weighted average. Initial exposure assessment before the start of any work to ascertain potential
exposures Exposure monitoring - representative, full-shift (i.e. 8 hours) employee air sampling is
required to determine if airborne exposure exceeds the PEL or the EL
PRESUMED ASBESTOS CONTAINING MATERIALS (PACMt Thermal system and sprayed-on or troweled-on surfacing materials in buildings
installed no later than 1980, as well as floor tile installed before 1980, are assumed to be asbestos containing materials unless an inspection by a "Certified Asbestos Inspector" or results of laboratory analysis of sampling indicate that the material does not contain asbestos. COMPETENT PERSON All asbestos related work must be supervised by a "competent person", who has received sufficient additional training specified in the standards for that class of work.
25