Mr. D.L. Engle Plant Manager Union Carbide Cor{Jf P.0. Box 471 Texas City, Texas 77590 ISIOIM AL;*Y cT^i ? i, JV' JK / ' Af Dear Mr. Engle: In recent months there has been increasing interest in the subject of/tal<particularly with regard to the nature and extWfof its asbestos content. Since you are one of our many valued talc purchasers, we feel you should be aware of important information on this subject. The Occupational Safety and Health Administration (OSHA) currently has in effect an asbestos standard which pre scribes that employees may be exposed to no more than 2 asbestos fibers per cubic centimeter of air for an 8-hour time-weighted average, and to no more than 10 asbestos fibers per cubic centimeter at any time. In October, 1975, OSHA proposed to lower the 8-hour timeweighted limit to 0.5 asbestos fibers per cc. and 5 asbestos fibers per cc. for any period not exceeding 15 minutes. Very recently it has been reported that the National Institute for Occupational Safety and Health has recommended the respective permitted exposure levels be limited even further - to 0.1 asbestos fibers and 0.5 asbestos fibers per cc. PLAINTIFFS EXHIBIT UC-1125 In its' October, 1975 proposal,.OSHA defines asbestos to include chrysotile, amosite, crocidolite, tremolite, anthophyllite and actinolite, and every product containing any of the'se minerals. OSHA also defines an asbestos fiber as a particulate form of any of these minerals which is longer than 5 micrometers, and has a maximum UCTC 17183 2- - The reason for the proposed revision of the standard for occupational exposure to asbestos is that asbestos, in its several commercial forms, has been associated with the production of not only asbestosis but a variety of cancers and malignancies. Because of the many unknown factors, including the variability of individual response to carcinogens and the absence of data to establish a safe level, OSHA has concluded that employee exposure must be reduced as low as is feasible. OSHA proposes to hold hearings on the entire subject, but until those hearings and subsequent deliberations take place there will continue to be considerable uncertainty. Nevertheless it is prudent for your workers, while using any talc which might contain asbestos fibers, to avoid creating dust to the extent possible. Monitoring procedures should be employed to determine dust concen trations under working conditions. Where appropriate, dust control equipment or use of respirators should also be considered, and worker training programs implemented. You will no doubt wish to review the various provisions of the OSHA standard for occupational exposure to asbestos (29 Code of Federal Regulations 1910.1001) and the pro posed amendments which appeared in the October 9, 1975 issue of the Federal Register. Since we have no control over the conditions of use of talc products in your plant, it is not possible for us to indicate the airborne fiber concentrations which could possibly result from your use of talc. However, we can provide information on the asbestiform mineral content of the talcs we supply. Pfizer research has developed the most accurate and sensitive method available today of analyzing for asbestos and asbestiform minerals in talc. This method, based on step scanning x-ray diffraction, electron diffraction, and transmission electron microscopy, permits identification of true chrysotile asbestos at levels of 0.5% and fibrous ampltiboles, such as tremolite, at levels as low as 0.1% in the talc. No other identifi cation methods in use today, including optical microscopy and scanning electron microscopy, are as sensitive and as direct. UCTC 17184 -3- Pfizer routinely monitors its' talc production, using this sensitive methodology. Based on many months of evaluation, we can state that: The California CP talcs which you purchase normally contain between 1% and 5% total tremolite with a fiber content of less than 0.1% by weight (the practical detection limit of the analytical method). The Montana MP talcs which you purchase contain no detectable quantities of tremolite or any of the asbestiform minerals. Thus, you can employ these MP talcs with full assurance that you are fully in compliance with the OSHA asbestos worker exposure standard. We believe that it is in your best interests and ours that information on this subject be brought to your attention. We trust you will find this letter useful, and that you will follow the OSHA hearings and other developments as they occur. We will continue to monitor these hearings and try to keep you aware of significant developments. If you have any questions, please do not hesitate to contact us. Very truly yours, uctcf'tt Please find on the attached list the item code number, location, and des cription of the asbestos items presently carried in stores inventory. Also, please advise what procedures should be followed in receiving', storing, issuing, and packaging these items to meet all regulations pertaining to asbestos. We have one estimated cost for placing spiral wound asbestos gaskets in ' polybags. Your earliest reply will be appreciated. JLC/dls Attachment '',/// . J }. L. Christensen Plant Purchasing ". * .>f ,,: J- -f VXs.'. UCTC HI*6 CODE NUMBER 63330-175 28786-410 28786-177 28786-178 28786-192 28803-050 36198-045 36198-065 28786-290 28786-022 28786-020 18423-068 18423-065 18424-017 28416-026 28416-027 28187-540 28416-140 28416-028 28416-155 28416-029 28360-126 28416-025 28424-225 28424-227 28424-229 28424-230 28424-232 28424-237 28424-234 28424-238 28424-239 28424-240 24824-241 28424-242 28424-243 28424-244 28051-435 28424-346 28424-094 ' LOCATION ' " SAC 477 , SAC 511' SAC 507 ' SAC 507 SAC 507 SAC 514 . SAC 584 SAC 584 SAC 584 SAC 584 SAC 584 - . DESCRIPTION UPSTAIRS Asbestos Mittens . Asbestos Mittens 3/8" J.M. Packing Asbestos Mittens 1/8" Garlock #5077 Packing Asbestos Mittens 3/16" Garlock #5077 Packing Asbestos Mittens 5/8" Garlock #5077 Packing . 1/8" x 1" W. Braided Asbestos Tape 1/16" Thick x 36" Asbestos Paper 1/8" Thick x 36" Asbestos Paper 1" Asbestos Rope 1/2" Asbestos Rope 3/8" Asbestos Rope SAC 017 SAC 017 SAC 017 SAC 020A SAC 020A SAC 020B SAC 020B SAC 02OB SAC 020B , SAC 020B SAC 020C ; SAC 020D SAC 020E SAC 02 0E SAC 020E SAC 020E SAC 020E SAC 020E SAC 020E SAC 020E SAC 020E SAC 02 0E SAC 02 0E SAC 020E SAC 020E SAC 020E SAC 020E SAC 020F SAC 020 : Top of Bin SAC 020 : Top of Bin . DOWNSTAIRS .025" Thick Tape X 1" Wide .015" Thick Tape X 3/4"Wide 1/8,r Asbestos Tubing 16-3/4" x 19-5/8" Flex. Gasket 17" x: 18-1/4" Flex. Gasket * - ^ 11-3/8" x 12-3/4" S. S. Flex. Gasket 19-1/4" x 20-1/4" S.S. Flex. Gasket 21-3/4" x 2-3/36" Flex. Gasket 24-1/4" x 26-1/4" Flex. Gasket v 8-1/4" x 10-7/8" Asbestos Filled Corrugated Gasket >. 12".X 16-3/4" Asbestos Filled Manhole Gasket 3/4" Ser. 15 Asbestos Filled Gasket 1" Ser. 15 Asbestos Filled Gasket 1-1/2" Ser. 15 Asbestos Filled Gasket 2" Ser. 15 Asbestos Filled Gasket 3" Ser. 15 Asbestos Filled Gasket ; 6" Ser. 15 Asbestos Filled Gasket 4" Ser. 15 Asbestos Filled Gasket 8" Ser. 15 Asbestos Filled Gasket 10" Ser. 15 Asbestos Filled Gasket 12" Ser. 15 Asbestos Filled Gasket 14" Ser. 15 Asbestos Filled Gasket 16" Ser. 15 Asbestos Filled Gasket 18" Ser. 15 Asbestos Filled Gasket 20" Ser. 15 Asbestos Filled Gasket 25-3/4" X 27-1/2" Asbestos Filled Gasket 24" 300# Asbestos Filled Gasket ; '24" 900# Asbestos Filled Gasket ' . v _; \jcrcm*1 * / . .. . *-wr- -r - \ > ' ,..1 Asbestos Material In Stores,; v/~/- Page 2 - Continued CODE NUMBER 28424-025 28424-030 28424-035 28424-324 28424-040 28424-045 28424-048 28424-050 28424-334 28424-337 28424-338 28424-339 28424-340 28424-341 28424-342 28424-343 28416-040 28424-055 28424-060 28424-064 28424-066 28424-071 28424-076 28424-101 28424-102 28424-103 28424-104 28424-082 28424-083 28051-400 28424-084 28424-085 28424-125 28424-126 28424-128 28424-112 28424-089 28424-091 28424-090 28424-092 28424-093 28424-065 28424-130 LOCATION SAC 02OF SAC 02 OF SAC 02OF SAC 02OF SAC 02 OF SAC 02 OF SAC 02 OF SAC 02OF SAC 02 OF SAC 02OF SAC 02 OF SAC 02 OF SAC 02OF SAC 020F SAC 020F SAC 02 OF SAC 02 OF SAC 020G ' SAC 020G SAC 02 0G SAC 020G SAC 020G SAC 02 0G SAC 020G SAC 020G SAC 02 0G SAC 020G SAC 02 0G SAC 020G SAC 02 0G SAC 02 0G SAC 02 0G SAC 02 OG SAC 02 0G SAC 02 0G SAC 02 0G SAC 020G SAC 020G SAC 020G SAC 02 0G SAC 02 0G SAC 02OH SAC 020H 't DESCRIPTION DOWNSTAIRS - . 1/2" 3-4-600# Asbestos Filled Gasket . . 3/4" 3-4-600# Asbestos Filled Gasket -' 1" 3-4-600# Asbestos Filled Gasket 'V'7':. -1 1-1/4"'3-4-600# Asbestos Filled Gasket, 1- 1/2" 3-4-600# Asbestos Filled Gasket-. ' 2" 3-4-600# Asbestos Filled Gasket . ' ?' ; 2- 1/2" 3-4-600# Asbestos Filled Gasket 3" 3-4-600# Asbestos Filled Gasket ` ; /. 4" Ser. 30 Asbestos Filled Gasket -/ 6" Ser. 30 Asbestos Filled Gasket :j / 8" Ser. 30 Asbestos Filled Gasket . 10" Ser. 30 Asbestos Filled Gasket ' 12" Ser. 30 Asbestos Filled Gasket ' -- ; 14" Ser. 30 Asbestos Filled Gasket . .. 16" Ser. 30 Asbestos Filled Gasket ./."'v .18" Ser. 30 Asbestos Filled Gasket .* 19-5/8" x 21-1/8" Flex. Asbestos Filled Gasket 4" Ser> 60 Asbestos Filled Gasket - 6" Ser. 60 Asbestos Filled Gasket 8" Ser. 60 Asbestos Filled Gasket ' v. 12" Ser.. 60 Asbestos Filled Gasket ' 7- 14" Ser. 60 Asbestos Filled Gasket : 7V ; : 7 1/2" 9-1500 Asbestos Filled Gasket - . --- 3/4" 9-1500 Asbestos Filled Gasket 1" 9-1500 Asbestos Filled Gasket 1-1/2" 9-1500 Asbestos Filled Gasket , :v 2" 9-1500 Asbestos Filled Gasket k* 3" Ser. 90 Asbestos Filled Gasket 4" Ser. 90 Asbestos Filled Gasket -. W. R. 2-1/2 9-1500# Asbestos Filled Gasket;./-- k, 6" Ser. 90 Asbestos Filled Gasket - v, // 8" Ser. 90 Asbestos Filled Gasket 3" Ser. 1500 Asbestos Filled Gasket 4" Ser. 1500 Asbestos Filled Gasket 6" Ser. 1500 Asbestos Filled Gasket . / ./ 10" Ser. 9-1500 Asbestos Filled Gasket , - V ^ ' 12" Ser. 90 Asbestos Filled Gasket ,- 16" Ser. 90 Asbestos Filled Gasket -' 14" Ser. 90 Asbestos Filled Gasket 18" Ser. 90 Asbestos Filled Gasket 20" Ser. 90 Asbestos Filled Gasket - - > ,,, 7 : - 10" Ser. 60 Asbestos Filled Gasket ..v;/- 8" Ser. 1500 Asbestos Filled Gasket ;> a UCTC 17188