Document b8vxzozyn6o3K4GpGpzkyykD

V/t ^' ftp** Monsanto Monsanto Company 800 N. Lindbargh Boulevard St. Louis, Missouri 63167 Phone: (314) 694-1000 FEB 4- ^987 LAW DEPARTMENT \ February 3, 1987 Mr. William D. Ingersoll Staff Attorney Enforcement Programs Illinois Environmental Protection Agency 2200 Churchill Hoad Springfield, IL 62706 . ' Dear Mr. Ingersoll: In your October 27, 1986 letter to me, you suggested several engineering controls, along with payment of a civil penalty and entry of a consent decree in connection with the incident which occurred at Monsanto's Krummrich Plant on March 3, 1986. My November 19, 1986 letter to you on this matter stated we would require additional time to better understand and study the U.S. EPA proposal regarding modification of the existing chloro-' sulfonic acid cooler system to operate without expansion joints. After giving full consideration to this matter, and discussing with other personnel the actions which have been taken by the Krummrich Plant subsequent to March 3, 1986, below is our response. I have set forth first the Agency's suggested action and then followed with Monsanto's response. Action 1. Installation of a catch basin to hold the materials in case of emergency. Response. Monsanto has completed its evaluation of the appropri ateness of a catch tank system to allow emptying of the reaction system in emergency situations pursuant to recommendation number 4 of Monsanto's Incident Investigation dated March 4, 1986. The attached Monsanto preliminary project scope report dated January 27, 1987 (Attachment A) sets forth a proposed automated drain system to address emergency situations. As noted in the report, the proposed system does not require the installation of a separate catch tank. The plant is submitting the proposed automated drain " system to upper management for approval and, upon receipt of such approval, will proceed with-installation. Please note that the document referenced and marked as Attachment A hereto is marked and claimed as trade secret property of Monsanto Company. os" 136464 STLCOPCB4036426 -z - Monsanto hereby incorporates by reference the trade secret justification previously submitted to the Agency for the chlorosulfonic acid process on March 21, 1986. Action 2. Monsanto should perform an in-depth engineering study to prepare for and enable Monsanto to replace the existing cooling system with one that does not utilize expansion joints. Response. Monsanto has completed its evaluation of alternative cooling systems for the chlorosulfonic acid reactor cooler, and the findings are summarized in a Monsanto report dated July 29, 1986, which was transmitted to the Agency on July 30, 1986. The report concluded that a trombone cooler (cascade system) is the best available means to cool the chlorosulfonic acid. U.S. EPA, in its September 11, 1986 letter to the Agency, agrees that trombone (cascade) type.coolers are acceptable in this application. The U.S. EPA letter goes on to state that U.S. EPA considers the presence of "expansion joints [as] a permanent source of possible incidents" and that U.S. EPA "strongly recommend[s] that efforts to be made to try to eliminate the use of expansion joints." Monsanto disagrees with both statements. Plant personnel are not aware of any expansion joint failures prior to March 3, 1986 of the type which occurred on that date, and the chlorosulfonic acid unit has been in operation for approximately forty years. Monsanto has subsequently consulted with Pfaudler Company, an experienced manufacturer of glass-lined equipment and piping. Pfaudler installed the existing chlorosulfonic acid reactor _ - cooler at the Krummrich Plant, and has consulted with Monsanto numerous times since then. Pfaudler has reviewed the existing cooler and the March 3, 1986 incident, and specifically recom mends use of expansion joints in its December 5, 1986 letter to Monsanto (Attachment B). Monsanto concurs with this recom mendation and believes that removal of the cooler expansion joints will increase the likelihood of acid releases. Replace ment of the existing cascade cooler system with one not utilizing expansion joints is unsupported and inappropriate. Action 3. During the interim time before the system is replaced, Monsanto should make monthly reports to the Agency providing the expansion joint replacement information including the exact reason for replacement (rather than a catch-all code number). Response. Monthly reports are not appropriate or needed in this instance. Monsanto_explained in its meeting with Agency person nel on July 17, 1986 that immediately after March 3, 1986 it had begun keeping a written log of specific repairs to the coolers-, and had provided a copy to the Agency by letter dated July 30, 1986. Monsanto advised the Agency at the meeting that it was planning to develop a preventative maintenance program for the cooler. This program is now in place and irs summarized in . Attachment C. The Plant plans to make this system a continuing DSW 136465 STLCOPCB4036427 -3- part of the cooler system operation. Accordingly, Monsanto does not believe that monthly expansion joint replacement reports to the Agency are necessary or appropriate. Actions 4 and 5. Payment of a monetary civil penalty. The above commitments [action items 1-4] should be contained in an enforce able decree. Response. It is Monsanto's view that such legal actions are inappropriate. There are several factors on which this conclu sion is based. First, and perhaps most important, is the positive program which has been initiated by Monsanto to reduce the likelihood of future emissions. This is a broad program and covers the entire Krummrich Plant. Since 1980, some fifty process improvements to reduce emission potential have been installed at a cost of $9,000,000. Other projects to reduce emissions through engineering controls are continuing. Second, at considerable cost in terms of both employee time and money, the Krummrich Plant has assisted State and local organiza tions in dealing with, and preparing for, emergency type situations. Among the examples of this type effort are: provid ing the industrial leadership in 1984 for installation of a community alarm system (for $65,000); visiting over twenty industries, municipalities and transportation agencies in 1986 to help improve and integrate local emergency response planning; conducting ten seminars in 1986 on handling chemical transporta tion emergencies for carriers and local fire departments; inviting local agencies, community leaders and others to visit the Krummrich Plant to view and discuss Plant products, operations, and emergency response capabilities. In addition, upon formation of the Illinois Governor's Chemical Safety Task Group, the Krummrich Plant requested to be included as one of the inspection -sites. It was and the Plant received a perfect 4.0 rating. Third, we feel it is significant that the emissions which occurred on March 3, 1986 resulted from causes which were beyond Monsanto's reasonable control. It seems inappropriate to penalize any party for events which the party intended to prevent and which resulted from causes beyond the reasonable control of the party. ' It would appear to be in the best interests of the State of Illinois that all citizens--corporate and individual--work together in an effort to improve the well-being of all. We feel that Monsanto's actions, particularly over the last two years, reflect well on its posture as a good corporate citizen. Any action at this time to penalize Monsanto for events which were unintended would seem to be contrary to the best interests of the State as a whole. _ DSW l36<*66 STLCOPCB4036428 -4- If after reviewing this letter there is still some feeling within the Agency that an action of some sort should be taken in con nection with the March 3, 1986 incident, I would like to have a prior meeting with you to review the matters discussed above in greater detail. Very truly yours, PHS:chPHSchl6 Enc. bcc: T. M. Bistline M. F. Foresman W. L. Smull Peter H. Smith Environmental Attorney OSVi STLCOPCB4036429 HMD PRELIMINARY PROJECT SCOPE CHLOROSULFONIC ACID DRAINAGE SYSTEM DEPARTMENT 217 MONSANTO CHEMICAL COMPANY TECHNICAL SERVICE DEPARTMENT W. G. KRUMMRICH PLANT SAUGET, ILLINOIS PREPARED BY: C. McGEE DATE: JANUARY 27, 1987 DSW 136468 ATTACHMENT A STLCOPCB4036430 DEPARTMENT 217 CHLOROSULFONIC ACID DRAINAGE SYSTEM PRELIMINARY SCOPE PURPOSE The project will purchase and install the equipment necessary to provide an automated drain system for the Chlorosulfonic Acid Finisher, Reactor and Reactor Coolers. The system will be initiated from the Provox console so that the conditions in the immediate area will not affect the draining operation. . BACKGROUND AND NEED On March 3, 1986, the Chlorosulf onic Acid unit experienced a release of an acid mist fog resulting from a leaking expansion joint on the Chlorosulfonic Acid Reactor Coolers. Plant emergency response personnel responded to the scene and immediately began applying a water fog to the acid fog leaving the area per emergency response procedures for Chlorosulfonic Acid. Upon determining that water had not entered the process and created a rupture, the acid was pumped to product storage stopping the leak. The investigation which resulted from the incident recommended an evaluation of a catch tank system to allow emptying of the reactor system in emergency situations. PROJECT SCOPE The proposed automated drain system will allow the Finisher, Reactor and Reactor Coolers to be drained in an emergency situation with minimum per sonnel exposure to the drain system area. The pump and the valves can be activated with a few key strokes on the Provox console. The system will be set up so that either G-6 or G-7 can be used as the drain tank. Once the emergency drain system is activated: the Reactor and Finisher pumps will shut off, automatic block valves on the FinisherReactor and Reactor Cooler drain lines will open, ' the automatic block valves on the appropriate storage header lines will open or close and, " " the drain pump will transfer the material to the tank. - Manual valves will be placed on the air lines to the automatic block valves. This will allow manual operation of the automatic valves if necessary. The automatic valves will "fail last position" in the event that instrument air pressure is lost. DSW 136^9 I ATTACHMENT A . STLCOPCB4036431 DEPARTMENT 217 CHLOROSULFONIC ACID DRAINAGE SYSTEM PRELIMINARY SCOPE (cont'd) OTHER ALTERNATIVES ` DO NOTHING: This alternative is not recommended. It does not eliminate the need for an emergency drain system in the case of a leak. INCLUDE AN IN-LINE SPARE PUMP IN ADDITION TO THE PROPOSED PROJECT: This alternative is not recommended. The department is currently operating on a five day per week schedule. Every week the unit will be shut down and drained using the proposed system. This will permit testing/monitoring of the drain system on the average once per week. The existing pump has been demonstrated to be very reliable. Given the frequent usage and historical mechanical reliability of the system, installation of a second pump is not necessary. INCLUDE AN ALTERNATE POWER SUPPLY (IN THE DEPARTMENT) TO RUN ONLY THE DRAIN PUMP IN ADDITION TO THE PROPOSED PROJECT: This alternative is not recommended. A power failure will not itself create a situation where the Chlorosulfonic Acid Finisher, Reactor and Reactor Coolers would need to be drained. The only circumstances where an alternate power supply would be a factor is if an unrelated power failure should occur concurrent with the specific time an emergency pump out were necessary. This is an extremely unlikely situation and consequently an alternate power supply is not necessary. PROVIDE A TANK WHICH WILL ALLOW THE MATERIAL TO BE GRAVITY DRAINED IN ADDITION TO_THE PROPOSED PROJECT: This alternative is not recommended. This addition to the proposed project would only be necessary in the event that the pump failed or power were lost from the substation coincidentally with an unrelated emergency which created a need to drain the equipment. This is an extremely unlikely situation and consequently an additional tank is not necessary. Draining the systems via gravity would normally be a more time consuming operation than pumping it empty. PROVIDE A NEW TANK DESIGNED TO HANDLE A WEAK ACID OR WATER LAYER: " This alternative is not recommended. A change in the startup and shutdown procedure has significantly reduced the possibility of water entering the system to such an extent that the additional tank and equipment is not necessary. '~ DSW 136470 2 ATTACHMENT A STLCOPCB4036432 DEPARTMENT 217 nnUL U CHLOROSULFONIC ACID DRAINAGE SYSTEM PROJECT SCOPE in, 2 OTHER ALTERNATIVES (cont'd) PROVIDE COMPRESSED AIR SUPPLY TO "BLOW" THE EQUIPMENT EMPTY IN ADDITION TO THE PROPOSED PROJECT: . This alternative is not recommended. This process normally operates at or near atmospheric pressure. Under the unlikely circumstances when an emergency drain would be required, the introduction of positive air pressure on the leaking system would further contribute to the losses and would likely worsen the situation. For this reason, this alternative is not recommended. CAPACITY The project will not affect the capacity. LOCATION OF FACILITIES All additions will occur within the battery limits of the Acid Division. EXPECTED COST RANGE The capital cost of this project is expected to be $95k. EXPECTED TIMING Project completion is expected 9 months after A.R. approval. ENVIRONMENTAL The project will decrease the duration of any acid mist/fog releases resulting from a leak in the Finisher, Reactor or Reactor Coolers. It will not prevent or reduce the instantaneous magnitude of a release. EMPLOYEE EXPOSURE TO HAZARDOUS MATERIALS This project will decrease the duration of major leaks and releases resulting in reduced exposure to Chlorosulfonic Acid and its fumes. The emergency drain system can be activated from the Provox console, keeping personnel out of the immediate release/leak-area. PRODUCTION CONTINUITY The necessary tie-ins can bejnade during regularly scheduled down time thus minimizing production delays. SW 1364 71 3 ATTACHMENT A STLCOPCB4036433 STLCOPCB4036434 PlifUUhm The Ptaudler Company Reply to: Don Doeli 1310 Gambia Onve Suite 6203 Schaumburg, ll 60'93 312 394 6609 1000 West Avenue P.O. Box 1600 Rochester, NY 14692 716 235 1000 TLX 978239 _ ,'ecsrnDsr Mr. Paul Brswer Monsanto Chemical Company 500 Monsanto Avenue Sauget, IL 62206 Dear Mr. Brewer: Thank you -for the courtesies extended to me during my recent visit to your plant to review your CSA cooler installation. As you know Ptaudler routinely' recommends the use or expansion joints with glasslined piping systems. Expansion joints help minimize thermal stresses which may cause glass damage. In addition, they reduce stress in the -flange area to help reduce casket leakage. Please see the attached instruction manual -for glasslined pipe. After reviewing your glasslined pipe instal 1 a "ion, P-faudler recommends the use o-f expansion joints. Since concern has been raised over a recent joint -failure, P-faudler also recommends regular inspection of these expansion joints and replacement as necessary. h'lease contact us i -f you have any questions. Si ncerely, The P-faudler Co. Donald Doel1 Sales Engineer cc: William DeFeri Chris McGee a Sohio Company 1364 73 ATTACHMENT b STLCOPCB4036435 praliubiir Glasteel Pipe And Fittings Instruction Manual IM55-100-2 1. DESCRIPTION Pfaudler Glasteel pipe and fittings are lined with corrosion-resistant glass fused to a steel substrate. Pfaudler glass is hard, nonpermeable and chemically inert. The metal substrate is rigid, strong and durable. The natural, fire-polished, smooth surface of Pfaudler glass adds im portant benefits to many piping in stallations. It provides a non adhering surface for transferring sticky products. Cleaning is rela tively easy and can often be done in place. Metal-sensitive materials are protected when handled through inert glass-lined pipe. When your process conditions change, you can probably reuse your existing Pfaudler pipe because of its wide-range resistance to corrosion. 1.1 Construction Glasteel pipe and fittings are manufactured in accordance with the following standards: Pipe ASTM A-106, Gr. B Pipe Flanges ASTM A-181-60 Elbows, Tees, Crosses, Reducers ASTM A-234, Gr. WPB Spacers, Reducing ASTM A-285-C Flanges Blind Flanges ASTM A-285-B Glasteel fittings provide the highest level of performance in terms of pressure-temperature limits when used with Glasteel pipe 1.2 Thermal Shock Pfaudler glass is scientifically com pounded to make it adhere to metal. During the firing process used to fuse the glass to the metal, helpful compressive stresses are built into the glass layer. However, the glass is subject to thermal shock damage. There are definite temperature limits above which damage can occur. Safe tempera ture differentials have been deter mined, but vary with the respective substrate metal, geometric configu ration and operating conditions. The maximum, safe, temperature differential is provided as a guide. The condition most likely to cause thermal shock damage is pumping a cold charge into a hot glass-lined pipe. Pumping a hot charge into a cold glass-lined pipe may cause a similar thermal shock condition. There are other operat ing conditions where temperature differentials will be encountered, but these are not as critical. The maximum, safe, temperature differential when the glass lining is at a temperature less than 121 C' (250F) is 128 C (230F). CAUTION: The risk of damaging equipment by thermal shock in creases as the operating temperature exceeds 121C (250F). Consult Pfaudler before operating above 12lC (250F). 1.3 Evaluate Temperature Limitations Consult Table I when plannm:: a glass-lined pipe installation tc '-ake sure that all of the compone" are evaluated in terms of their re- -ac tive operating and thermal s- :k limits. The LOWEST tempera-- a limit must be applied to the ENTIRE glass-lined pipe installation. 2. INSTALLATION 2.1 General Precautions Glasteel pipe and fittings are very tough but must be handled careful ly to prevent damage to the giass lining. CAUTION: Never strike glass-lined pipe and fittings with tools or other hard objects. Glass damage could result. Mechanical stresses caused by unequal or excessive bolt torques, springing or pulling pipe into posi tion, or clamping pipe too tightly (which prevents uniform thermal ex pansion) can result in damage to the glass. Never weld to the exterior of a Glasteel part without consulting Pfaudler. 2.2 Applicable ANSI Standard Make sure you read and under stand ANSI/ASME B31.3 before in stalling any Glasteel pipe and fittings. This standard contains the information you must have to as semble a safe, reliable process pip ing installation. 2.3 Gaskets Gaskets must be inserted between ail glassed flanges. The use of Pfaudler PTFE-envelope gaskets for TABLE I -- TEMPERATURE LIMITS OF PFAUDLER GLASTEEL PIPE AND FITTINGS AT 150 PSI CORROSION: Continuous exposure to acid environment 121 C (250CF)' THERMAL SHOCK: When glass lining is less than 121 C (250F) 128C AT (230 FA T) OPERATING (from -29C (-20F) to temperature listed below): Plain pipe (includes 232C pipe with side outlets) (450F) Fittings (elbows, tees. crosses, etc.) Reducing flanges qsw 136474 232C (450 F)^ 232 C (450 F) Blind flanges 'Up to 232C (450F) for seme applications. Consult Pfaudler. 232C (450 F) ATTACHMENT B STLCOPCB4036436 TABLE II -- RECOMMENDED BOLT TORQUES 1 FOR ANSI CLASS 150 STANDARD BOLTING (foot pounds) NOZZLE SIZE (in.) 1 1'/2 2, 3 4, 5 6, a BOLTS 2-3 NO. SIZE (in.) 4 V2 4 Vi 4 5/a 8 5/a 8% CRT, CRT-AF GASKETS LUB.4 20 20 40 40 70 DRY 30 30 60 60 100 FOR ANSI CLASS 300 STANDARD BOLTING (foot pounds) NOZZLE SIZE (in.) 1 IV2 2 3, 4 6 8 BOLTS 2- 3 NO. SIZE (in.) 4% 4% 8% 8% 12 V* 12 7/a CRT, CRT-AF GASKETS LUB.4 40 70 40 70 70 110 DRY 60 100 60 100 100 160 1. Torques are recommended for well-lubricated (LUB.) and for unlubricated (DRY) bolts. 2. ASME Spec. SA 193 Grade B7, indentified by B7 stamped on J-bolt or bolt head. 3. ASME Spec. SA 194 Grade 2H nuts, identified by 2H stamped on top surface. 4. Pfaudler strongly recommends lubrication to reduce variable binding between the bolt and nut. The nut should also ride freely over the complete length of the bolt threads before assembly. joining Glasteel pipe and fittings is strongly recommended. These gaskets are soft and compressible and provide a tight seal without damage to the glass sealing sur face. They are non-porous and free of ridges and bulky joints. They . withstand the operating temperature and pressure limits for Pfaudler Glasteel pipe and fittings. They can be shimmed when necessary. The corrosion resistance of Pfaudler envelope gaskets -is comparable to that of Pfaudler glass. 2.4 Bolting And Split Flanges -- All non-drilled flanged pipe and fit tings are furnished with Pfaudler steel split flanges drilled to ANSI Class 150 or Class 300 standards. ASME SA 180-60 forged steel is used for the IV2 through 8 inch di ameters; A536-60 for the 1 inch di ameter. A square-shape split flange is supplied with the 1, 1 Vz. 2 and 3 inch pipe and fittings where flange clearance is minimal. A round shape is furnished on the larger sizes. Recommended bolt torques are given in Table II. 2.5 Layout Layout of Glasteel piping is, in general, the same as for conven tional piping. A difference is that steps must be taken to prevent un due stresses, particularly at the flanged joints. It is good practice to provide a number of offsets, using elbows, expansion joints, etc., to ease fit-up and to minimize thermal stress. In addition, supports should be provided at 10-foot intervals to prevent sagging at the joints, which can cause leakage. Another difference is that reduc ing fittings such as tees, crosses and elbows are neither supplied nor recommended. When such a reducing situation arises, a combi nation of straight fittings and either straight reducers or reducing flanges will best meet the need. Allow V* inch per joint to com pensate for the combined thickness of the glass coating on the flanges and the compressed sealing gasket. Do not fix the position of small pieces of equipment such as pumps until after the piping has been made up. This will permit an adjustment that might not be possi ble otherwise Figure 1. Bolt Tightening Sequence Copyright Sohio Chemicals and Industrial Products Company 1986. All rights reserved. DSW 136475 ATTACHMENT B STLCOPCB4036437 2.6 Installation Precautions 1. Avoid stress at ail joints. Keep pipe and fittings free to move to avoid stress when connecting flanges. Use expansion joints' in lines between two vessels to permit both axial and lateral adjustment. Use expansion joints' in longer lines if they are rigidly connected. Use expansion joints* at places where there is a source of vibra tion, such as pumps. Assemble off sets, condensers, etc in snake fashion, i.e.. consecutively along the lines. This will reduce strain at the flanges because the pipe will be free to move laterally. 2. Never pull or spring pipe into place Make sure all joints are on same center line with flanges nearly touching (normally within 'A inch and never more than Vz inch apart). Use offset arrangements and/or expansion joints to correct misalignment and adjust length. Where practical, use spacers to make any minor length adjustments along the line. Glasteei spacers Vz to 3 inches long are available. If line is sloped, use tapered gaskets. Gaskets with Vz degree slope can be supplied.* 3. Make sure mating flanges are parallel. Measure distance between flanges at several points around cir cumference Readjust piping or shim gaskets to correct misalign ment. Recheck alignment. Shim gasket to correct minor discrepan cies. Refer to IM81-100 for shim ming procedures. 4. Secure the flanges properly. Use correct size gasket. Install split flanges and tighten two fastening bolts supplied. Tighten bolts evenly around flanges (see Figure 1). Table II lists recommended sizes; refer also to ANSI/ASME 831.3. Use only recommended sizes. Use only recommended bolt torques as listed in Table II. 5. Support lines properly. Place supports at 10-foot intervals to keep joints from sagging. On vertical runs, use riser clamps above or be low floors. Where possible, install clamp below a joint. Do not sup port piping too rigidly. Allow some freedom of movement to relieve thermal stress. 6. Retighten all bolts and clamps after one operating cycle, or after at least 24 hours at rest. 'Available from Pfaudler Edlon Division 7. 00 NOT insulate over flanges until product has completely cycled. 3. PREVENTIVE ' MAINTENANCE 1. Check bolt torques at all joints regularly. 2. Check joints fer leaks. If a joint leaks; a. Make sure bolts are tightened evenly. b. Replace gasket if necessary. c. Correct any possible cause of strain at joint. 3. Watch for acid spills on outside of pipe or fitting, and hose off im mediately. Acid spills may react with the steel causing chipping or fish-scaling of glass on inside 4. Check periodically for any exter nal damage that may have caused breakage of glass on inside. Be sure to replace any damaged part. 5. If pipe is jacketed, clean inside of jacket regularly at intervals deter mined by experience. Refer to IM81-100 for cleaning procedure. 4. HOW TO ORDER 1. To order pipe, specify: a. The desired number of pie =s b. Nominal diameter c. Actual length of each piece o nearest !/a inch. ' 2. To order fittings, specify: a. Each type of fitting by name b. Nominal diameter or size of each fitting. c. Desired quantity of each 3. Specify gaskets separately, nai- cate the number needed anc .se nominal pipe diameter to show gasket size. NOTE: There is no need to order split flanges. Pfaudler automatically supplies the required number of -teel split flanges for each length of r.pe and each fitting that you ofder. 4. Address all orders to: THE PFAUDLER COMPANY Attention: Parts Dept. P.O. Box 1600 Rochester, NY 14692 Telephone: 1-800-828-6545* *ln New York and Canada call: 1-716-235-1000. sw 136^6 ATTACHMENT B STLCOPCB4036438 These installation, operation ana maintenance instructions are berevea to cetenacie general guidelines fcrusageor the eguicment described herein. THE PFAUDLERCOMPAN Y EXPRESSLY DISCLAIMS ANYWARRANTY.EXPRESSORIMPLlED.OFFiTNESS FOR ANY SPECIFIC PURPOSE iN CONNECTION WITH THE INFORMATION CONTAINED HEREIN. Unless otherwise specifically provided in thecontrac: of sale P'aodsr does not crcvide oroject engineering, process design or plant layout services and. accordingly, theinformanoncresen!eaherem>sgenerai in nature andshouionotOeconsiceredaeplicacieto any specific crocess or application. While Pfaudlerequipmentisdesigned and rnar.ufacturea inaccoraance'.vitn appiicadlecodesandgoodmanufactunng prac tices. it is the responsibility of the userto locate and install the eouicment and orovide those safety and warning devices which are appropriate for the specific application intended by the user. DEFINITION OF POTENTIAL HAZARDS The following definitions are presented to clearly identify the degrees of hazard that are recognized by The Pfaudler Company as being involved in the installation and use of vessel accesso ries and are dealt with in the Instruction Manual. Each defini tion is given a characteristic typographic treatment and format here and throughout the Instruction Manual to help readily iden tify the degree of hazard referred to in all cases. DANGER: IDENTIFIES HAZARDS WHICH WILL RE SULT IN SEVERE PERSONAL INJURY OR DEATH. WARNING: Identifies hazards which could result in per sonal injury. CAUTION: Identifies hazards which could result in damage to equipment or property. ' NOTE: Alerts users to pertinent facts and conditions. a Sohio-Company The Pfaudler Company P.O. Box 1600 Rochester, NY 14692 716-235-1000 (Telex 978239) IMP1SS-3 5M You'll find us nearby. Contact our sales representative in the Pfaudler branch office nearest you: Albany, NY .............. 518-785-4466 Charlotte, NC............ 704-541-5953 Chicago, IL.............. 312-671-0474 Cincinnati, OH.......... 513-561-8068 Davis. CA .................916-753-4120 Detroit, Ml.................313-855-6220 Houston. IX .........713-492-7243 New Jersey/New York Metro Area.........201-882-9483 Philadelphia. PA . .215-692-7704 Rochester. NY ..716-235-1000 St. Gabriel; LA ... . 504-642-5436 'Service Call appointments can be scheduled thru these offices. DSM 136477 ATTACHMENT B Printed in U.S.A. Monsanto PROM < NAME-- LOCATION-- RHONE P. J. Shaw W.G.K. Plant DATE January 28, 1987 SUBJECT C/S REACTOR COOLER INSPECTION PROGRAM TO B. DeFer The Chlorosulfonic Acid reactor coolers are currently on a routine inspection program. Details of the program are as follows: 1. The production first line supervisor will inspect the coolers each week while the unit is shutdown. Results of the inspection will be logged in the cooler inspection booklet. He will fill-in the date, observation, job number (if needed), and signature. 2. The maintenance first line supervisor will check this booklet each week. He will update the work done, part number, inspection results, noting specific information for each repair, date completed, and signature sections of the booklet consistent with the production first line supervisor. 3. The production engineer will review this booklet 'on a quarterly basis. He is responsible for determining raoccurring problem areas and developing an action plan. - 4. The reactor coolers were added to the department SIAM list with a 6 _ month frequency of inspection by the M&MT group. PS/jc / P. J. Shaw DSW 136478 ATTACHMENT C STLCOPCB4036440