FfOi\ tNMC A LOCATION) W. B. Papageorge - St. Louis SUBJECT CFEENCE July l6, 1971 " D. Danna - B2NA J. R. Durland - 5260 PCB WASTE INCINERATION H. Kada - Yokkaichi M. Mori - Yokkaichi Memo S.U. to W.B.P. dated 6-17-71 TO S. Uneno - 5260 The scrap liquid incinerator was placed into operation in May with-the following operating conditions. Incinerator Temperature 2400 - 2600F. Waste Rate 2 gpm (1200 #/hr.) Auxiliary Gas 1.5 K BTU/hr. Incinerator Pressure 80 inches HpO Op in Exit Gas Weir Water 30 gpm . Quench Spray Water 110 gpm Quench Pot Temperature 205F. .' f Venturi Water Flow Scrubber Water 25 gpm 75 gpm To Sewer: 0.4$ HC1 20 ppb PCB To Atmosphere: 0.015 grains particulate/ft.3 0.6 # HCl/hr 45 Ppm C/2 0.0004 # PCB/hr. The solid waste incinerator referred to in the April 21, 1971 PCB Management Plan was intended to dispose of capaci tors as well as transformer parts, floor sweepings, treat ment clay, treatment carbon, rags, etc. The test which was conducted in December indicated that the technology required to properly incinerate was available. Cost estimates for r in. 1 1. i DEPOSITION | EXHIBIT I Papageorqe I " 98 mzm WATER PCB-SD0000040546 2- the disposal of 10 million pounds per year indicated an equipment cost of approximately 1 million dollars and operating costs approaching 10 cents per pound of scrap. The decision was made to postpone the installation of an incinerator until the need was great enough to Justify the cost. In the meantime, we are recommending the use of approved landfills. I have enclosed copies of correspondence relating to the test run and copies of literature on shredding equipment. It appears from the Wall Street Journal article that Eidal International has representatives in Japan. Id . Enclosures W. B Papageorge 1 r 0003276 WATER PCB-SD0000040547