HOFFMAN VALVES and CONTROLLED HEAT EQUIPMENT
HOFFMAN VENTING VALVES
In the Hoffman line there is a specially designed venting valve for every type of heating system. The basic principle used in the design of all Hoffman venting valVeT'"
that of an all-metal thermostatic member, containing a volatile or heat sensitive fl \j
which causes valve action upon slight temperature changes.
Uld
Hoffman valves have a wide pressure range in which they operate with the sa degree of accuracy, for the internal fluid pressure in the thermostatic member maintain6
a constant relationship with the external steam pressures throughout the whole ranee f
pressure for which each valve is intended.
*0
Hoffman valves are automatic,. non-adjustable and (except Nos. 20 and 21) are
guaranteed to properly function for a period of five years from date of installation when
installed and operated under normal conditions for which designed.
*
VENTING VALVES FOR ONE-PIPE SYSTEMS
ALL METAL--NON-ADJUSTABLE--THERMOSTATIC
The No. 1 Hoffman Siphon Air Valve is designed for systems of the one-pipe gravity type, to vent all air from radiators without loss of steam. After contact of water with the valve the siphon drains alt water, from the valve and venting occurs without the slightest "spit" even if the radiator is under pressure.
Radiator connection, H in. Maximum guaranteed operating pressure, 10 lb.
The No. 4 is used in venting mains, risers, vento stacks, coils, etc. All air is freely vented through a H in. vent port without steam loss, but valve does not close against water.
Standard connection, H in., can also be supplied with H in. connection. Maximum guaranteed operating pressure, 10 lb.
The No. 5 is particularly adapted for .use in venting: Ends of steqm or dry return mains; Indirect radiators; Blast or "Vento" stacks; Hot-water generators; Dryers and drums, etc.
The basic principle is the same as the No. 1 Valve, having separate channels for air and water which are only found in Hoffman Valves.
Pipe connection, % in.; vent port [or less than 3 lb. is A m* I for 3 lb. and over is fg in. Unless otherwise ordered, will be shipped with A in. port. Maximum guaranteed operating.pressure, 10 lb.
Write for Descriptive Circular-- The Watchman of the Coal Pile
'
818
Specialty Co., Inc.
Specialties, Heating
VENTING VALVES FOR ONE-PIPE VACUUM SYSTEMS
In construction, the No. 2 Valve is similar to the No. 1
with the addition of a vacuum diaphragm in the base
and an air check over vent port. Upon steam contact, float diaphragm (7) expands,
closing port (2). When pressure goes below atmosphere vacuum diaphragm (8) follows up contracting float diaphragm, maintaining port closed against air intake.
Air check (1) functions only in the case of a half-hot radiator when float diaphragm (7) is not expanded by steam contact. With a cessation of steam generation, air check holds port closed against air intake until pres sure goes below atmosphere and when a 1 in. vacuum forms diaphragm (8) expands, closing port, relieving air
check of any further function. The superiority of the diaphragm controlled port
compared with valves having air check only is indicated by the fact that the total pressure exerted in holding vent port closed is approximately 20 times greater than that exerted in maintaining an air check closed.
This greater pressure, exerted by the vacuum dia phragm holds the valve pin more tightly against its seat
and also aids in crushing or pushing away dirt particles which might be caught between
the valve pin and its seat. Radiator Connection % in. Maximum guaranteed Operating pressure 10 lb.
The No. 6 Float Air and Vacuum Valve is similar in design and
application to the No. 5 with the additional feature of the Air Check or
Vacuum starter above vent port and vacuum diaphragm in base. Used
for venting ends of mains, vento stacks, etc., where water is liable
to be present.
..
Pipe connection, Y% in.; vent port for less than 3 lb. is Ha in;; fr 3 jb-
and over is H6 in. Unless otherwise ordered, will be shipped with He in.
port. Maximum guaranteed operating pressure, 10 lb.
Wo. o
The No. 16 Air and Vacuum Valve is used for venting
ends of steam and dry return mains. Valve is
in. high
overall, permitting installation in lines close to ceiling. It
has the special Hoffman feature, the combined air check
and vacuum diaphragm for preventing return of air to
--system. Pipe connection,. H in. Vent port He in. d'a.
Maximum operating pressure, 10 lb.
Wo. 18
The No. 3 Hoffman Air Line Valve is specially designed for Air Line, or as they are frequently termed "Paul" Systems. It is sensitive in action and closes the instant steam fills the radiator.
Radiator connection, % in.; Air Line connection, H in.
Maximum guaranteed operating pressure, 10 lb.
THE HOFFMAN VALVE LOCK
Prevents theft of No. 1 and No. 2 valves in public buildings, etc. No extra tapping is required as lock is easily applied when valve is inserted in radiator. By using set screws, valve is locked in position and can only be removed by a special key.
Hoffman Valve Lock
Write for Descriptive Circular--Locking the Door Against the Heat Thief