July 27. 1972
CIMS Numoer
Trenton ChemicaL
Plant. Cl!;ce
CIMS Number
Chrysler Center
On July 11. . 1972. a study was made at the Friction Materials Building to evaluate empLoyee exposure to asbestos in the Finance Department. Lunch Room and Laboratories. Results of all these samples were beLow the allowable 5 fibers per milliliter threshold limit value for asbestos. Results appear on the attached data sheet.
Several of the tools used in the Product Development Labora tory* need improved ventilation. The ventilation for the equipment in this laboratory and also for the Aampco brake shoe grinder in the garage discharge fiLtered air into the plant. This type of ventilation does not meet the require ments of the State Health D-.partment. The exhaust air from this equipment must be filtered and discharged to the outside in soch a manner as to prevent recirculation.
We recommend that the ventilation system for the belt sander. disc grinder, band saw, table saw, radial arm saw. and the Aampco brake shoe grinder be improved in accordance with the ventilation designs shown on the attachments. In addition, we recommend that an air-line respirator type NPSP-226 be provided whenever bond endurance tests are run in the dynamometer test room.
hm Attachments
w. F. Bavinger R. F. Bowers W. T. Diehl D. L. Eschelbach R. T. C-askill T. J. Lang E. R. Lombard R. D. McIntosh. F. & Repucci E. F. Ruiz, M. D J. G. Shepherd N. A. Trombley
/ , . -^ G. A. Sattelmeier Industrial Hygienist
*
\
M-H0-78T9 ntv ,-vro
Data Sheet ^renton Chemical
7////7 V Asbestos
Location Threshold Limit Value
Finance Department Office area - five feet from doorway to plant Production employee's lunch room
Dynamometer test room, operating B side, * running general endurance test on
brakes
Concentration in fibers/ml 5
0.7
0.8 0.5
The above samples were collected on 0.80 micrometer cellulose ester filters using an MSA Personal Sampler.
5-68 INDUSTRIAL VENTILATION
HORIZONTAL BELT SANDERS
BeH width,
Erhjust VOk:rr, cfm
mchss
Head end
Toil end Total
Up to 6 >ncl
440
350 TOO
over 6 to 9 me!
550
350 s:o
ever 9 to 14 incl
800
440
1240
ever 14
II CO
550
1650
Duet velocity - 3500 fpm Entry losses - 0.40 VP for tapered take-off
/V.ERICAN CONFERENCE OF GOVERNMENTAL INDUSTRIAL HYGIENISTS
HORIZONTAL CELT SANDERS
date
i-64
|
VS-702
f
l
\
i
i
i
[
\
0
l
D>sc diam., inches
Up to 12 ever 12 to 19 over 19 to 30 over 30 to 36
Exhaust volume, cfm 220 390 610 680
Minimum duct velocity - 4SCO fpm bronch, 3500fpm mom. Entry loss -0.65 VP for straight take-erf.
- 0.45 VP for topered take-ot f.
Note: if best practicalhood is a poor enclosure, increase exhaust volume accordingly.
AMERICAN CONFERENCE OF GOVERNMENTAL INDUSTRIAL HYGIENISTS
HORIZONTAL SINGLE- SPINOL E DISC GRINDER
date
~61
|
VS-409
< 1< I 1
I I l
.tCV( v. . .... < a.
./
\
5-70
INDUSTRIAL VENTILATION <
TOP HOOD DETAIL
Blade width,
Erhc'jst volume, cfm
inches
Butt. >/n Too
Total
Uo to 2 over 2 to 3
over 3 to 4
ever 4 to 6 over 6 to 3
J5C 350 55C 55C 550
350 550
800 HOO
1400
700 S00
1350
1650 1050
Duct velocity - 3500 fpm Entry loss -1.75 VP m duct riser (Point A)
AMERICAN CONFERENCE OF GOVERNMENTAL INDUSTRIAL HYGIENISTS
BAND SAW
date
i-66
VS-706
5.71
INDUSTRIAL VENTILATION
Table, rip, mitre and voriety sows.
Sow diameter, inches
Exhaust volume, cfm
Up to 16 met. over 16 to 24 met over 24 variety with dodo
350 440 550 5*0
Duct velocity - 3500 fpm Entry loss - LO slot VP * 0.25 duct VP
AMfRICAN CONFERENCE OF GOVERNMEM'.Al INDUSTRIAL HYGIENISTS
TABLE SAW
DATE
/ -64
I
VS-70B
SPECIFIC OPERATIONS
5-71
IS NOT CUT THRU
TYPE HOOD WHERE TABLE IS CUT THRU
Saw diameter, mchcs
Up to 20 me!
over 20
Exhaust volume, cfm
350
440
Duct velocity - 3500 fpm Entry loss * 178 slot VP 10 25 duct VP
AMERICAN CONFERENCE OF GOVERNMENTAL INDUSTRIAL HYGIENISTS
SWING SAWS
date
7^64
|
VS-707