Document b5qnGLp6OEYZ4KoBBwbKmOZd1
INDUSTRIES
To: F. C. Dehn Z. G. Bell
INTER OFFICE CORRESPONDENCE
Date: March 2, 1977
nom: P. J. Snyder Location: 10 West
subject: Revised VDC Monitoring Summary
Please find attached a revision of my initial surrmary of the Division's Vinylidene Chloride (VDC) Air Monitoring Data that is presently available.
This re-evaluation was conducted to determine the degree of compliance with three specific levels of VDC, 1.0, 2.5, and 10.0 ppm.
The available monitoring data suggests that the plants are generally within the present guideline of 10 ppm, but over either 1.0 or 2.5 ppm (TWA).
Lake Charles data show 12% over 2.5 and 22% over 1.0 ppm, overal1. Based on a limited amount of information, the 3 jobs of highest anticipated exposure have 63% over either 1.0 or 2.5 ppm (TWA).
/ale Attachment
P. J. Snyder
FORM 509-A RCV 6.1-70
073732 SL
INTRODUCTION
Based on available personnel and area air monitoring data, an evaluation was conducted in order to ascertain the impact of a 1, 2.5 and 10 ppm Vinylidene Chloride Standard, (VDC). This information has been categorized by plant lo cation and by the time period for which data is available.
DATA SUMMARY: PERSONNEL MONITORING DATA
Location: Lake Charles
Period: 4/75-4/76
Two hundred thirty one (231) VDC personnel samples are on file, of these 60 or 26% were analyzed in excess of 1 ppm. Although each of these were not identified as TWA, short-term or ceiling samples, it is estimated that approximately one-half of these 60 samples, are time weighted averages. Samples in excess of 1 ppm were recorded for 14 job categories, representing at least 83 individual employees. Adequacy or coverage of the sampling protocol was not done, therefore, the total number of employees potentially exposed to VDC is unknown at this time. The sampling results for this time period point to eight potential problem areas.
1. EDC Operator 2. Loader 3. Loader Helper 4. Pipefitter
5. MC Operator 6. MC Aux. Operator 7. P/T Still Operator 8. P/T Aux. Operator
PERIOD: 6/1/76 - 12/13/76,60 personnel samples are on record, and 13 or 22% were analyzed to be in excess of 1 ppm with 7 or 12% over 2.5 ppm. None of the monitoring results were in excess of 10 ppm. Table 1 below provides a specific breakdown of the monitoring data for this period.
SAMPLE TYPE
NO. SAMPLES TAKEN
NO. SAMPLES > 10 PPM
NO. SAMPLES > 2.5 ppm
NO. SAMPLES >1-0 ppm ...
CEILING
0
00
0
SHORT TERM
11
0
1
2
TWA 49 0 6 11
TOTALS
60
0
7(12%)
13(22%)
Personnel monitoring was conducted on 20 Job categories, with concentrations greater than 1 ppm reported for 5 jobs. The number of personnel that this figure represents is undetermined at this time. The highest value recorded is 6.3 ppm VDC, (MC. Aux Operator). This monitoring data indicated most the same job categories as mentioned above as representing the problem areas. Table 2 below provides a more specific breakdown for three job categories that have a direct involvement with VDC.
DEPARTMENT: TRI ETHANE - VDCM-MC
EDC OPER TRI ETHANE OPER
NO. SAMPLES TAKEN
1 3
TRI ETHANE AUX OPER
8
TWA DATA
0.45 3.70 2.70 0.90 6.30 5.00 4.50 0.470
OTHER DATA
--
1.80 0.78 0.12 O.nn SL 073733
Location: Corpus Christi
Period: 7/1/76-12/31/76
Thirty (30) personnel samples were recorded, and none were found to be greater than .86 ppm. It should be noted that all 30 samples were obtained in the labora tory. This data indicates that this represents 15 employees actual exposures.
Location: Barberton
Period: 7/1/76-12/31/76
A single personnel sample was taken on a "Technical Chenist". A concentration of 0.1 ppm was recorded.
Data Sumnary: Area Monitoring Data
Location: Chemical Division
Period: 7/1/76-12/31/76
Two hundred sixty four (264) area samples were recorded across the Division for VDC during this time period. Except for three measurements at Natrium and ten at Lake Charles, all area monitoring was conducted at Corpus Christi. The highest two readings were both taken at Lake Charles (Per/Tri-Tetra) and were recorded as 14.9 and 3.2 ppm, (short term monitoring).
CONCLUSIONS
1. Records show that 322 VDC personnel air monitoring samples were taken over the two time periods 4/75 - 4/76 and 7/76 - 12/76,(Lake Charles (6/76 - 12/76)).
2. 73 or 23% of these 322 samples were analyzed to be in excess of lppm.
3. Most personnel samples are taken at Lake Charles, most area at Corpus Christi. The highest area sample was recorded to be 14.9 ppm (Lake Charles).
4. Lake Charles has 8 job categories in particular that have most of the highest exposures to VDC.
5. The three job categories expected to have the highest exposures to VDC have a total of 8 TWA samples for the last six months of 1976.
6. Based on the available monitoring data, respirators are not worn for exposure to VDC.
SL 073734
Attachment I
EDC Operator MC. Operator MC. Aux. Oper. P/T RX Oper. P/T Still Oper. P/T Aux. Oper. VC Proc. Oper. VC Furn Oper. EC Operator P/T Tetra Oper. OHC Operator OHC Aux. Oper P/T Lead Oper. Lab Assoc. Lab Assist Lab Anal. Lab Sr. Anal. Loader Load Helper Pipefitter Maint. Helper
KE CHARLES VDC MONITORING RESUI A/75-4/76
Impact of a IPPM Standard
No. Samples 4/75-4/76
16 20 25 21 24 16 15 16
9 6 10 10 3 12 2 4 1 9 8 2
2 231
Highest Value 5.6 12.5 43.0 2.8 15.6 8.4 .38 1.0 1.2 1.5 .60 .32 .33 4.1 1.12 .10 .11 2.8 10.0 96.0 1.7 96.0
No. Samples > 1.0 7 12 17 1 9
5
1 1 1 1 1 2 1 1 60
TABLE III
No. Employees Sampled 6 7 6 6 8 7 11 11 8 6
5
6 3
5
2 6 2 8 6 5 3
SL 073735
Attachment II A
PERSONNEL VDC MONITORING RECORDS 6/1/76 - 12/31/76
TABLE IV
PLANT: LAKE CHARLES
Department: EDC Liquid Phase
Job Title Recorded
if Samples
Taken
Highest Value
EDC Operator
1
0.4
if Samples
> IPPM
-
if Employees
Sampled
1
Total if
Employees on Job
?
Ethyl Chloride
EC HCL Oper
2
Per/Tri-Tetra
P/T Lead Oper.
1
P/T RX Oper
3
P/T Still Oper
3
P/T Aux. Oper
7
Shift tepeIrwin
1
Ueldar
.. 1 Shipping
Loader
4
Load Helper
4
Lab Assoc.
Technical 2
Trieth-VDCM-MC
EDC Operator
1
Tri-Ethane Oper.
3
Tri-Ethane Aux. Op. 8
OHC-EDC
0*C Auxiliary Oper. OiC Operator Tetra Opwator
1 1 1
0.39
0.27 1.00 1.5 2.6 0.11 0.10 1.0 3.8
0.00
0.45 3.70 6.30
0.00 0.00 0.00
-
-
1 2 -
-
2
-
2 4
-
24
1 17 23 36 4 12 1 1 2 18 3 13
29
1? 35 6 12
1 1 1
SL 073736
PLANT: Lake Charles (Continued)
Vinyl Chloride
EC HCL Oper. Oper.-VCM-Furn.
3 6
Oper.VCM-Proc.
7
0.11 0.10 0.29
Sub Totals
60 6.3
PLANT: CORPUS CHRISTI
Department: Research
Analyst
1
Chemist
7
Lab. Anal.
4
Technician
5
Technic. Sr.
8
.07 .30 .60 .10 .86
Chemist Lab Tech.
Research/Laboratory 4 1
.10 .05
Sub Total
30
.86
PLANT: Barberton
Department: Research/Laboratory
Tech Chemist
1
Division Totals
91
0.10 6.3
-- -
11
-
-
11
3 5 6
1 3 2 2 3
3 1
1
4
1 ?
O'!'131 SV