Document b5mnnvjYK145dwyMRwobrgvnZ

]/ c yrj Mr. R, N. Wheeler December 10, 1971 VINYL CHLORIDE VAPOR IN AIR Dispersion Resin Unit Vinyl Resin Area SOUTH CHARLESTON PLANT Dear Nick: Attached are results of additional air samples that you requested for determir vinyl chloride vapor in air throughout the vinyl resin area. In the general atmosphere all breathing level samples showed concentrations less than 100 ppm. Nick, to support the concentrations obtained with the Drager Detector tube, we collected bag samples at a few spot locations. The Gas Chromatographic results were as follows: Sampling Conditions Gas Chromatograph ppm BREATHING LEVEL - General atmosphere No. 31 Autoclave top manhole open 30 wishing autoclave No. 33 Autoclave - normal: operation No. 35 Autoclave - norman operation Drag r tube ppm <iDa> BREATHING LEVEL- General atmosphere . 32-34-36-47-48-49-45-50 Autoclaves in operation BREATHING LEVEL- General atmosphere No. 37-39-41-43 Autoclaves' in operation BREATHING LEVEL-General atmosphere 38-40-42-44 Autoclaves in operation except No.44 Let us know' if further sampling Is necessary Bert Murray ucc 035284 VINY L CHLORIDE VAPOR IN .AIR ,v DISPERSION RESIN UNIT SOUTH CHARLESTON PLIANT Sample No. <> Date Time 1971 Autoclave No. 12/2 9; 05a.m. 43 Sampling Condition BREATHING LEVEL Autoclave in operation Drager Detector PPM <100 V ^2 12/2 9:15a.m. 41 I8"in$ide top manhole 1/2 full of productpumping to No. 38 autoclave 1500/ fj;03. 0 4. \2/2 9:20a,m. 44 12/2 10:00a.m. 38 0 5. 12/2 10:15a.m. 38 '0 6. 12/2 10:25a.m. .40 BREATHING LEVEL Autoclave in operation BREATHING LEVEL Manhole open - Autoclave 2/3 full of product from autoclave No. 38 18"inside top manhole 2/3 full of product from autoclave No. 41 BREATHING LEVEL Autoclave in operation <100 <I00< >3000^ <100 ;p 7 08 12/2 10:30a.m. 33 BREATHING LEVEL Autoclave in operation 12/2 10:40a.m. 35-36-45 BREATHING LEVEL Autoclaves in operation <100 <100 O 9 'N 7 10. \ ' II. ;12. -P 13. Mv' ' 14. 12/2 10:45a.m. 32-46-47-49 BREATHING LEVEL Autoclaves in operation 12/2 10:50a.m. 43 Near bottom drain Washing autoclave 12/2 11:10a.m. ' 37-43 BREATHING LEVEL 6*-8` from bottom drain 12/2 I!;l5a.m. 37 BREATHING LEVEL AT top manhole Washing autoclave 12/2 Il:20a.m. 43 ' BREATHING LEVEL At top manhole Before washing autoclave 1^2 Il:25a.m. 43 BREATHING LEVEL At top manhole* Washing started \A/ A*Lt - -------- - ' - <100 lv >3000 * <100 ^ 200 600 * <100 ^ ucc 035235 Sample No. & 15 16 Date 1971 \2/Z 12/2 Time Autoclave No. Sampling Condition 2:55pm. 41 10" above open manhole 1/2 full of product transferring product 3:00p.m. 41 10" above open manhole approxl/2 full of product transferring product Drager Detector Tub PPM 220 -w 330 17 12/2 3:i0p.m, 41 10" above open manhole full of product-transferring 1000 \ 18 12/6 8:50a.m. Building 153 BREATHING LEVEL OPERATOR TAKING SAMPLE 125 19 12/6 8:55 a.m. Building 153 Breathing LEVEL pacing north-south in control room <100 20 12/6 10; 35a.m. 42 (T) 21 12/6 2:50 p.m. 42 n 22 12/8 Il:05a.m. 42 15!' inside ppen manhole Before wqshing and airing 15" inside open manhole Before washing and airing BREATHING LEVEL Inside autoclave at bottom 1500 * 875 X 450 J 23 12/8 11:10a.m. 42 5 ) 24 12/10 8:45a.m. 35 BREATHING LEVEL Inside autoclave at bottom Liquid oozing from resin a* it was chipped off. 18" inside top manhole in operation -agitator on 875 * 1500 ' () 25 12/10 8:50 a.m. 31-33-35 BREATHING LEVEL No. 31 autoclave manhole open No. 33*35 in normal operation t <100 4 NOIE: ALL MEASUREMENTS IN OPERATORS" CONTROL ROOM BUUJILDING 190 WERE LESS THAN 100 ppm. The same levels for Building 152 and 154............... ucc 035236