Document b5ja6aYnyvxbb1kZwa8ND16yZ
C. A. Dunham Co.
Specialties, Heating
"8^
i Trap No. J
No. 1. All Patterns Tapping J4"; Capacity 100 sq. ft. Rad.
No. 2. A11 Patterns Tapping H"; Capacity 350 sq. ft. Rad.
z
Trap No. t
No. 3. A11 Patterns
Tapping
Capacity 450 sq. ft. Rad.
No. 4, Angle and Straightway
Tapping
Capacity 1500 sq. ft. Rad.
4 Trap No. 1,
3
Trap No. 3
No. 5. Angle and Straightway Tapping 1"; Capacity 3000 sq. ft. Rad.
DUNHAM BLAST TRAP
5 Trap No. S
and less
In s.e..l.e...c..t.inag* wcoaopigaicitjiutieiso,r dbreasinuirneg abnladstrehdeuacteingbclaosilts.coil radiation to equivalent direct radiation by multiplying the actual surface of coil by a factor ranging from 6 to 10, depending on temperature, velocity and volume of air blown over coils.
The operation of traps No. 6 and 7 is similar to that of the radiator trap, using the thermostatic principle, while No. 8 and No. 16 traps combine the Dunham thermostatic principle with the float. They handle large volumes of water successfully. Made only (or
pressures up to 10 lb. on vacuum or gravity systems. -'
Size
'No. 6
Pipe Connection. In.
CapacityLhrect Radiation. Sq. Ft.
'No. 7
1,500
No. 16 No. 16
3.000 6.000
No. 16
No. 16 No. 8
I'A
i'/i
7,000 . 9.000 11,000
'Made m angle and straighlSJTpattSS:
16,000
300
C. A. Dunham Co.
Specialties, Heating
Dunham Reducing Pressure Valve
Made only in standard weight for a pres sure range of 125 lb. down on high side, to 10 lb. and atmosphere on low side, in straight and expanded outlet patterns.
Dunham Vacuum Pump Governor
Used on steam driven vacuum pumps to control vacuum in vacuum return lines. Made in all sizes from Yi to 2 in., inclusive.
Dunham Damper Control
The Dunham Diaphragm Damper Regulator controls the steam pressure in ounces. It operates check and draft damper with chains.
Dunham Air Eliminator
Used in connection with the Dunham Home Heating System for venting the air from the system.
Capacity for 2000 sq. ft. radiation.
Dunham Oil Separator
Made in all sizes from Flanged connections.
to 6 in.
Dunham Strainer
Has a large brass screen basket for
catching and holding the dirt; easily ac
cessible for cleaning and at once commends
itself'for this purpose. Made in all sizes
from
to 6 in., with flanged ends only.
Dunham Air Line Valve
The principle of operation is identical,
and design similar, to the Dunham Radi
ator Trap. Its efficiency is high, and serv
ice in connection with air line systems
invaluable. Can be furnished with either
H or
radiator connection. Air
piping is required in connection with its
use. It must not be subjected to steam
pressures exceeding 10 lb. gage.
Dunham Air Line System
This is a one-pipe steam system using a Dunham Air Line Valve,on each radi ator, with a sytem of air--line piping which may discharge the air by gravity, or be attached to an air line Vacuum
Pump. This system is particularly adapt able in making old one-pipe heating sys tems more efficient. It is easily and eco nomically installed, and insures the quick removal of air from the radiators.
The Dunham Home Heating System
This is specially for the home or small building. It uses steam at very low pres sure, not over 8 oz. Steam is admitted into the radiator by the Dunham Packless Radiator Valve, where it is retained by the Dunham Radiator Trap until it has given off its heat, when, as water, it passes through the trap together with the air, and back to the boiler through the return piping. The air is released by the Dun ham Air Eliminator, and the water returns naturally to the boiler. Hot water pattern radiators with top inlet connections are re quired. The end of each steam main is vented through a Dunham Trap into the return piping, and is dripped through wet or dry drip pipe directly back to the boiler return header.
The Dunham Return System
This System differs from the Home Heating System in that it makes use of the Dunham Return Trap in place of the Dunham Ajr Eliminator, which introduces the added.feature of a positive automatic return of water to the boiler when it is desired to raise the steam pressure.
The feature of a positive return under varying steam pressures makes this Dun ham System particularly adaptable to apartment houses, small hotels and med ium size commercial buildings, schools and churches. This System makes possible the modernizing of old one-pipe and two-pipe gravity systems, and eliminates the sput tering, leaking air valves which are such trouble makers in these old heating jobs.
The Dunham Vacuum System
Simplicity is the key note of Dunham design. There is the system of steam mains and piping to supply all radiation, and the return piping to carry away the air and water of condensation by means of a vacuum pump. Steam may be sup plied direct from boiler, or through a Dun ham Reducing Valve, where boiler pres sure is too high for direct service. Or ex haust steam may be used, supplemented by live steam through a Reducing Valve.
'Bulletins
Bulletins of standard architectural size with detailecf information covering each System, and all products, including roughing-in dimensions, will be furnished on request.