R. L. Stuart__________________ May 16, 1977 ELECTRICAL TRACING SURVEY
(
cc
In February a SHAC notice was issued highlighting a potential problem with "MI" electrical tracing cable. This cable very closely resembles copper tubing and if inadvertently cut it could expose an employee to as much as 480 v. A much more preferred installation is Chemelex Cable which resembles TV antenna cable.
To determine the extent of the "MI" cable hazard, SHAC is requesting information from across the plant. To assist us with this please complete the torm oeiow anq^-return it to me by June 10.
Chairman SHAC Committee
ELECTRICAL TRACING REPLY Survey Completion date _ Is Electrical Tracing used in your area . Is the tracing sufficiently identified. Approximately how many feet of tracing is involved _____ How many applications of "MI" Cable in your area__________ Approximately how many feet of "MI" tracing is involved Do you have plans to replace the "MI" Cable________________
RLS/es Enclosures
Signed
LAM026476 SC 18813
A .I.A . No. 30-A-2
FOR EFFECTIVE WINTERIZING, PROCESS PIPE HEATING
A .I.A . No. 30-A-2
:<>n ..- r i 1 * ^ ' a iiT .
|A product of EDWIN L WIEGAND COMPANY, 7500 Thomas Boulevard, Pittsburgh,. Pennsylvania 15208
5CHR0MAL0X electric heating elements packaged process'heaters and systems 5*comfort hesten
^e/octricsteam generators^\/nfrar*d ftaters and ovens power cab/es c--ontrols
'OCopyright 1965, Edwin L. Wlogand Company
V SC 18814
LAM026477
- u. -
Table 310-13 (Continued)
Trede Neme
Tree Utter
Mex. Op.folia.
Temp.
Application Pravirian.
Insulation
AWO nr
MCM
Thickness o# Insulation
M3,
Extruded Polytetra-
(luoroelhylene
TFE
2J0*C 482* F
. Dry locations only. Ontyjfor leads Extruded
within apparatus or within race Polytetraways connected to apparatus, or fluoroas open wiring. (Nickel or nickel- ethylene
coated copper only.)
.14-10
1-2 1-4/0
20 30 43
Outer Cnvexing
None
Thermoplastic and Asbestos
TA 90* C Switchboard wiring only. 194*F
Thermoplastic
and Fibrous Outer Braid
TBS
90*C 194*F
Switchboard wiring only.
Thermo plastic and Asbestos
14-8 .
6-2 ..
1-4/0
Th'pT. ...20 ...30
Asb. 20
25 30
Flameretardant.
nonmettUic covering
Thermoplastic
14-10 S ... 6-2 . 1-4/0
30 Flame-
45 retardant, 60 nontnetaOic 10 covering
Synthetic Heat-Resistant
SIS 90*C Switchboard wiring only. 194*F
HeatResistant Rubber"
14-10 * ...
JW1-4/0
30
43 .60,
None
80
8J*C 18J*F
2J0*C 482*F
Dry and wet locations. For special application.
16-10 Magnesium 9-1 ..
Oxide
3-250
36 50
55
o
Table 310-13 (Continual)
Underground Feeder&
Branch-Circuit Cable-Single Conductor. (For Type UF cable employing more lhan one con ductor see Arti- . de 339)
UF
60*C 140*F
75*C-- 167*F
See Art, 339
Underground Service En trance Cable-Sin gle Conductor. (For Type USE cable employing more than one conductor set Article 338)
USE
75*C I67*F
See Aft, 338
SiliconeAsbestos
SA 90*C Dry locations. 194*F
12S*C 257* F
For special applicatfion.
MoistureResisiam
14-10 ..................... *60 8-2............................ *80 1-4/0....................... *95
Integral with
insulation
Moisiureand HeatResisunt
Heat- and . Moisture-
Resistant
12-10....................... 8-2............................
1-4/0 ..................... 213-500 .................. 501-1000 .................. 1001-2000 ................
45 60
80 95 110 125
------
Moistureresistant nonmetallic covering See 338-1 (2)
Silicone Rubber
14-10 .......................... 45 8-2 .............................. 60 1-4/0 .......................... 80 213-500 .................. 95 soi-1000 ...................... no 1001-2000 .................... 125
Asbestos or glass
* Includes integral jacket. For ampacity limitation, see 339*1 (a). The nonmeiallic covering over individual rubber-covered conductors of aluminum-sheathed cable and of lead-sheathed or muHiconductor cable shall not be required to be flame retardant For metal-clad cable, tee Section 334-4. For nonmetallic-sheathed cable, see Section 336-2.
For Type UF cable, see Section 339-1. For aluminum-sheathed cable, see Section 331-23. For insulated,aluminum and copper-clad aluminum conductors, the minimum sire shall be No. 12. See Tablet 310-18 and 310*19.
>
TO
nrm--
u \
q
z o n
2
o
TO
Cmi mZ " r"
TO
5
O
ni
9
n
UIW026478
l-i. '
SC 18815