Document b5NG4g4yZM8ZNE3904b9KGNny
RCRA Inspection Report
1) Inspector and Author of Report
Robert S. Nakamoto, P.E., CHMM Environmental Engineer Phone: 404-562-9341 nakamoto.robert@epa.gov
U.S. Environmental Protection Agency, Region 4 Enforcement and Compliance Assurance Division Chemical Safety and Land Enforcement Branch RCRA Enforcement Section 61 Forsyth Street, S.W. Atlanta, Georgia 30303
2) Facility Information
Century Aluminum of South Carolina Inc. Mount Holly Plant 3375 Highway 52 Goose Creek, South Carolina 29445
EPA ID: SCD097366165 NAICS: 331313 - Alumina Refining and Primary
Aluminum Production 331314 - Secondary Smelting and Alloying of Aluminum
3) Responsible Official
Scott Courtney, P.E. Environmental Manager Century Aluminum of South Carolina Mount Holly Plant 3375 Highway 52 Goose Creek, South Carolina 29445
4) Inspection Participants
Jonathan Brown, Century Aluminum of South Carolina Inc. (Century Aluminum) Reginald Coleman, Century Aluminum Jacoby Alsten, Century Aluminum Tom Richmond, South Carolina Department of Environmental Services (SCDES) Ryan Donohue, SCDES Robert Nakamoto, U.S. Environmental Protection Agency (EPA), Region 4
5) Date and Time of Inspection
June 26, 2024, at 9:00 a.m.
EPA-RCRA CEI Report June 26, 2024
Page 1 of 76
Century Aluminum of South Carolina SCD097366165
6) Applicable Regulations1
Resource Conservation and Recovery Act (RCRA) Sections 3002, 3005 and 3007 (42 U.S.C. 6922, 6925 and 6927), and the regulations promulgated pursuant thereto at 40 Code of Federal Regulations (C.F.R.) Parts 260-270, 273 and 279.
South Carolina Hazardous Waste Management Act, S.C. Code Ann. 44-56-10 et seq., and South Carolina Hazardous Waste Management Regulations (SCHWMR), S.C. Code Ann. Regs. 61-79.260-270, 61-79.273 and 61-79.279.
Pursuant to S.C. Code Ann. Regs. 61-79.262.17(a) [40 C.F.R. 262.17(a)], a large quantity generator (LQG) may accumulate hazardous waste on-site for 90 days or less without a permit or without having interim status, as required by Section 44-56-60(a)(2) and (b) of the SCHWMA, S.C. Code Ann. 44-56-60(a)(2) and (b) [Section 3005 of RCRA, 42 U.S.C. 6925], provided that the generator complies with the conditions listed in S.C. Code Ann. Regs. 61-79.262.17(a) [40 C.F.R. 262.17(a)] (hereinafter referred to as the "LQG Permit Exemption").
Pursuant to S.C. Code Ann. Regs. 61-79.262.15(a) [40 C.F.R. 262.15(a)], a generator may accumulate as much as 55 gallons of non-acute hazardous waste and/or either one quart of liquid acute hazardous waste at or near the point of generation where wastes initially accumulate, which is under the control of the operator of the process generating the waste, without a permit or without having interim status, as required by Section 44-56-60(a)(2) and (b) of the SCHWMA, S.C. Code Ann. 44-56-60(a)(2) and (b) [Section 3005 of RCRA, 42 U.S.C. 6925], provided that the generator complies with the satellite accumulation area conditions listed in S.C. Code Ann. Regs. 61-79.262.15(a) [40 C.F.R. 262.15(a)] (hereinafter referred to as the "SAA Permit Exemption").
Pursuant to S.C. Code Ann. Regs. 61-79.273.9 [40 C.F.R. 273.9], a "Small Quantity Handler of Universal Waste" (SQHUW) is a Universal Waste handler who does not accumulate 5,000 kilograms or more of Universal Waste (batteries, pesticides, mercury-containing equipment, or lamps, calculated collectively) at any time.
Pursuant to S.C. Code Ann. Regs. 61-79.273.14(a) [40 C.F.R. 273.14(a)], an SQHUW must label or mark the universal waste to identify the type of universal waste.
Pursuant to S.C. Code Ann. Regs. 61-79.273.15(c) [40 C.F.R. 273.15(c)], an SQHUW who accumulates universal waste must be able to demonstrate the length of time that universal waste has been accumulated from the date it became a waste or is received.
1 As the State's authorized hazardous waste program operates in lieu of the federal RCRA program, the citations of those authorized provisions will be to the authorized State program. However, for ease of reference, the federal citations will follow in brackets.
EPA-RCRA CEI Report June 26, 2024
Page 2 of 76
Century Aluminum of South Carolina SCD097366165
Pursuant to S.C. Code Ann. Regs. 61-107.279(c)(1) [40 C.F.R. 279.22(c)(1)], containers and aboveground tanks used to store used oil at generator facilities must be labeled or marked clearly with the words "Used Oil."
Pursuant to S.C. Code Ann. Regs. 61-107.279(d) [40 C.F.R. 279.22(d)], generators of used oil upon discovery of a release of used oil must stop the release, contain the released used oil, clean up the used oil, and make any necessary repairs or replacements to the container or tank.
7) Purpose of Inspection
The purpose of the inspection was to conduct an unannounced RCRA compliance evaluation inspection (CEI) to determine the compliance of Century Aluminum of South Carolina Inc. with the applicable regulations. This was an EPA lead inspection supported by SCDES inspectors.
8) Facility Description
The Century Aluminum Company was founded in 1995. Century Aluminum Company is a U.S. based metals and mining company that is headquartered in Chicago, Illinois. The company is focused on bauxite, alumina, and aluminum production. The company has operations in the U.S., Iceland, Jamaica, and Netherlands. The company operates a bauxite mining and alumina refinery in Clarendon, Jamaica (Jamalco) that produces smelter grade alumina. The company operates four aluminum reduction facilities. Three of the four aluminum facilities are located in the U.S. They are in Hawesville, Kentucky (Hawesville Plant which is currently idled), Robards, Kentucky (Sebree Plant), and Goose Creek, South Carolina (Mt. Holly Plant). The fourth facility is located in Grundartangi, Iceland (Nordural Plant). The company operates a carbon anode manufacturing facility in Vlissingen, Netherlands. The company produces approximately 800,000 tons of aluminum per year.
The Mt. Holly Plant is located in Goose Creek, South Carolina. The Century Aluminum Mt. Holly Plant (Century Aluminum or "the facility") has a production capacity of 229,000 metric tons per year. The facility normally operates with approximately 460 employees.
The Mt. Holly Plant operates a primary aluminum reduction facility that produces high grade aluminum from the raw material aluminum oxide (alumina) using the Hall-Heroult electrolytic process. The facility has two Alcoa-designed potlines with a total of 360 reduction cells. There are three steps in the operation: 1) the manufacture of carbon anodes from coke and pitch, 2) the reduction of alumina to produce molten aluminum, and 3) the processing of aluminum for end users. Aluminum is produced via high electrical currents passing through the reduction cell that has the alumina, molten cryolite, and the anodes. The high current separates the aluminum for the oxygen molecules to produce aluminum. The facility contains casting equipment used to cast molten aluminum into standard-grade ingot, HDC ingot, extrusion billet and other value-added primary aluminum products. The facility can produce over 35 different
EPA-RCRA CEI Report June 26, 2024
Page 3 of 76
Century Aluminum of South Carolina SCD097366165
types of aluminum alloys in a wide variety of shapes and sizes. The Mt. Holly Plant was the first aluminum facility in the world to be registered to the ISO 9001 Quality System Standard. The Mt. Holly facility is also environmentally certified to the ISO 14001:2015 standard.
9) Previous Inspection History
SCDES has conducted four RCRA CEIs at the subject facility between 2004 and 2019 and identified a total of six violations during those inspections. On August 19, 2019, SCDES conducted the most recent RCRA CEI at the subject facility and found one apparent violation of RCRA's requirements for an issue with Contingency Plan requirements. As a result, SCDES issued a Return to Compliance Letter to the facility on November 5, 2019.
10) Opening Conference
On June 26, 2024, EPA inspector Robert Nakamoto, accompanied by South Carolina Department of Environmental Services (SCDES) inspectors Tom Richmond and Ryan Donohue, arrived at Century Aluminum at approximately 9:00 a.m., and registered at the security gate. Reginald Coleman, the facility's Environmental Specialist, came to the security area and escorted the inspection team to a conference area. The inspectors introduced themselves, showed their credentials to Reginald Coleman, and explained the purpose of the inspection. Jacoby Alsten, an Environmental Supervisor at the Mt. Holly Plant, joined the opening conference.
The inspectors described the anticipated use of a digital camera during the inspection and discussed the request for records. The facility's staff objected to having any photographs taken inside of the facility, as the facility had a policy of no photographs being taken by outside parties. After discussing this issue, as a compromise, it was agreed that the facility staff would take photographs and send them to the inspection team prior to the inspection team leaving the site.
The EPA inspector explained that the Small Business Regulatory Enforcement Fairness Act's classification of a "small business" is generally set by the Small Business Administration using the business' SIC/NAICS code and annual receipts or number of employees. A copy of the EPA's information sheet for small businesses can be found at https://www.epa.gov/sites/production/files/2017-06/documents/smallbusinessinfo.pdf. The EPA inspector also discussed the company's ability, pursuant to 40 C.F.R. 2.203, to assert a business confidentiality claim for information submitted to the EPA. The company did not assert a business confidentiality claim.
It was briefed that the facility was constructed in 1979 and began operation in 1980. The Mt. Holly Plant is located on a 5,000-acre piece of property. The facility is operating around the
EPA-RCRA CEI Report June 26, 2024
Page 4 of 76
Century Aluminum of South Carolina SCD097366165
clock (24/7) and was estimated to have approximately 450 employees at the time of the inspection. The facility receives its water supply from the City of Charleston Water Utility. Dust from the air pollution control baghouses is recycled back into the production line. It was briefed that the company is operating approximately 39 hazardous waste satellite accumulation areas (SAAs) and two Central Accumulation Areas (CAAs). The facility does not have a wastewater treatment plant. It was briefed that all hazardous waste is managed in containers and that the facility had no hazardous waste tanks. The main hazardous waste that is produced is spent pot liners (SPLs) waste (K088) that is sent to Clean Harbors Canada, Inc. in Ontario, Canada.
11) Inspection Observations
The facility is conducting inspections of its SAAs and maintains an inspection tracking log sheet. Some areas are inspected on a weekly basis. The inspection team elected to inspect the two CAAs and a random sample of the SAAs. Jacoby Alsten took the photographs during the inspection. Both Reginald Coleman and Jacoby Alsten accompanied the inspection team during the entire inspection. The first area inspected was the SAAs for the potline maintenance area, Satellite Area (SA)-1 and SA-1A. SA-1 had a plastic 55-gallon used oil container and a metal 55gallon used oil container. Neither container had a "Used Oil" label (Photograph 1). SA-1A had a 4-foot tube container of universal waste lamps and a 5-gallon plastic container of universal waste batteries that were closed, labeled, and dated (Photographs 2-4).
Pursuant to S.C. Code Ann. Regs. 61-107.279(c)(1) [40 C.F.R. 279.22(c)(1)], containers and aboveground tanks used to store used oil at generator facilities must be labeled or marked clearly with the words "Used Oil."
Building 270 has an SAA (SA-2) for the Carbon Maintenance. SA-2 had an aerosol can puncturing device that had a hazardous waste label and hazard marking. Facility staff briefed that they manage the punctured cans as hazardous waste due to residuals in the cans after puncturing. The device was not in use but was initially open at the time of the inspection, and then was immediately closed by Century Aluminum staff (Photographs 5-7). SA-2A had a 5-foot container of universal waste lamps that was not labeled or dated, two four-foot containers of universal waste lamps that were labeled and dated, and one 4-foot container was empty. Two 5-gallon containers of universal waste batteries were labeled and dated (Photographs 8-10). There were two metal 15-gallon containers of used oil that were closed and labeled.
Pursuant to S.C. Code Ann. Regs. 61-79.262.15(a)(4) [40 C.F.R. 262.15(a)], which is a condition of the LQG permit exemption, an SAA container holding hazardous waste must be closed at all times during accumulation, except: (i) When adding, removing, or consolidating waste; or (ii) When temporary venting of a container is necessary (A) For the proper operation of equipment, or (B) To prevent dangerous situations, such as build-up of extreme pressure.
EPA-RCRA CEI Report June 26, 2024
Page 5 of 76
Century Aluminum of South Carolina SCD097366165
Pursuant to S.C. Code Ann. Regs. 61-79.273.14(a) [40 C.F.R. 273.14(e)], an SQHUW must label or mark the universal waste lamps to identify the type of universal waste.
Pursuant to S.C. Code Ann. Regs. 61-79.273.15(c) [40 C.F.R. 273.15(c)], an SQHUW who accumulates universal waste must be able to demonstrate the length of time that universal waste has been accumulated from the date it became a waste or is received.
The inspection team next went to the CAA for containers by Building 139 (Container CAA). The inspectors observed that Building 139 had large hole(s) in the roof, the floor was coated with a clear liquid, powdery material was scattered across the floor, and there was a large pile of a powdery material in one area of the building. Due to safety concerns related to issues with the building's roof and the material and liquid in the building, the inspection team decided not to enter Building 139. The inspectors conservatively estimated that the waste pile of powdery material (also referred to "Waste Bath" by Century Aluminum staff) was approximately 30 feet high by 40 feet by 40 feet wide at the base. The inspectors observed that clear liquid covered approximately half of the visible floor area (Photograph 11). The inspectors observed, approximately a dozen supersacks near the waste bath pile, and near the liquid covering the floor. The super sacks near the pile were in poor condition. There were numerous super sacks stored at the rear of the building that appeared to be in better condition than the ones near the waste bath pile (Photograph 12). The waste bath pile, and the super sacks adjacent to the waste bath pile, appeared to be abandoned, and/or discarded, and did not appear to be being managed as a product. At the time of the inspection, a manager was contacted, who informed the inspectors that the material in the pile, and the supersacks, had been in the building for approximately 4 to 5 years.
Due to the free liquids on the floor and the status of the roof, a review of Building 139's maintenance status and materials management is recommended.
The Container CAA adjacent to Building 139, was surrounded by a chain link fence that was 8 feet tall in places and 5 feet tall in other places and was under a roof. The CAA had a "no smoking" sign, a spill kit, fire extinguisher, and an eye wash and safety shower. There were three 300-gallon tote tanks that were labeled as non-hazardous waste containing nonpumpable oil from maintenance activities. Two of the tote tanks were full and one was half full. The tote tanks were not labeled as used oil but were labeled as "Non-Pumpable Oil" and being managed as a non-hazardous waste (Photographs 13-14). At the time of the inspection, the inspectors observed a leak of a black liquid that appeared to be a used oil leak originating from under one of the tote tanks (Photograph 15). Because the tote tanks still contained some portion of free-flowing used oil they are required to also be labeled as used oil.
Pursuant to S.C. Code Ann. Regs. 61-107.279(d) [40 C.F.R. 279.22(d)], generators of used oil upon discovery of a release of used oil must stop the release, contain the released used oil, clean up the used oil, and make any necessary repairs or replacements to the container or
EPA-RCRA CEI Report June 26, 2024
Page 6 of 76
Century Aluminum of South Carolina SCD097366165
tank.
Pursuant to S.C. Code Ann. Regs. 61-107.279(c)(1) [40 C.F.R. 279.22(c)(1)], containers and aboveground tanks used to store used oil at generator facilities must be labeled or marked clearly with the words "Used Oil."
Universal waste was stored in the Container CAA. There were four 4-foot tube containers of universal waste lamps that were closed but the containers were missing the accumulation dates (Photograph 16). There was also a 3-foot container of universal waste lamps labeled and dated March 28, 2024.
Pursuant to S.C. Code Ann. Regs. 61-79.273.15(c) [40 C.F.R. 273.15(c)], an SQHUW who accumulates universal waste must be able to demonstrate the length of time that universal waste has been accumulated from the date it became a waste or is received.
At the time of the inspection, the inspectors observed that the Container CAA had a 5,000 gallon Used Oil tank that was labeled as "Used Oil" (Photograph 17). A metal container for collecting used oil from the used oil pumps' operations, was present but was not closed or labeled as "Used Oil" (Photograph 18).
Pursuant to S.C. Code Ann. Regs. 61-107.279(c)(1) [40 C.F.R. 279.22(c)(1)], containers and aboveground tanks used to store used oil at generator facilities must be labeled or marked clearly with the words "Used Oil."
At the time of the inspection, the inspectors observed 30 metal 55-gallon containers of materials that the facility staff stated was non-hazardous waste from clean-ups. There were two metal 55-gallon containers of "Used Oil debris" and 28 metal 55-gallon containers of oily grease debris and oily soil that were being managed as non-hazardous waste. Several of the containers appeared to be in poor condition, including one container that appeared to be significantly bulging due to excessive internal pressures (Photographs 20-25).
The facility representatives informed inspectors that the facility had shipped its hazardous waste from the Container CAA on Tuesday, June 25, 2024. At the time of the inspection, the inspectors observed one metal 30-gallon container of ignitable (D001) hazardous waste dated April 23, 2024, remaining in the CAA. The other containers had been shipped. This container was in poor condition as evidenced by being completely coated in rust (Photographs 26-27).
Pursuant to S.C. Code Ann. Regs. 61-79.262.17(a)(1)(ii) [40 C.F.R. 262.17(a)(1)(ii)], which is a condition of the LQG permit exemption, if a container holding hazardous waste is not in good condition, or if it begins to leak, the LQG must immediately transfer the waste to a container that is in good condition or manage the waste in some other way that complies with the exemption requirements.
EPA-RCRA CEI Report June 26, 2024
Page 7 of 76
Century Aluminum of South Carolina SCD097366165
The inspectors observed a Universal Waste Connex adjacent to the Container CAA. Inside the Connex, the inspectors observed a metal 55-gallon container of broken lamps being managed as toxic (D009) hazardous waste. This container was being utilized for broken universal waste lamps. The container was labeled as containing hazardous waste and had a Class 9 DOT label, but was not properly marked or labeled with an indication of the hazard of its contents (Photograph 28).
Pursuant to S.C. Code Ann. Regs. 61-79.262.15(a)(5)(ii) [40 C.F.R. 262.15(a)(5)(ii)], which is a condition of the LQG permit exemption, a generator must mark or label its container with the following: (ii) An indication of the hazards of the contents (examples include, but are not limited to, the applicable hazardous waste characteristic(s) (i.e., ignitable, corrosive, reactive, toxic); hazard communication consistent with the Department of Transportation requirements at 49 CFR part 172 subpart E (labeling) or subpart F (placarding); a hazard statement or pictogram consistent with the Occupational Safety and Health Administration Hazard Communication Standard at 29 C.F.R. 1910.1200; or a chemical hazard label consistent with the National Fire Protection Association code 704).
At the time of the inspection, the inspector observed a 6-foot container and two other universal lamp containers in the Connex that were open (Photographs 29-30).
Pursuant to S.C. Code Ann. Regs. 61-79.273.13(d)(1) [40 C.F.R. 273.13(d)(1)], a small quantity handler of universal waste must contain any lamp in containers or packages that are structurally sound, adequate to prevent breakage, and compatible with the contents of the lamps. Such containers and packages must remain closed and must lack evidence of leakage, spillage or damage that could cause leakage under reasonably foreseeable conditions.
The Containment Building CAA, Building 138, was inspected next. Building 138 is where cleanouts and repairs of the aluminum pots are conducted. The clean-out and repair processes generate spent pot liners from primary aluminum reduction (K088), a listed hazardous waste. The pots are large vessels approximately the size of a railcar. The building has a cooling room to allow units to cool down prior to any work being done on the pot. A wall separates the cooling room from the process area (Photographs 31-32). A crane lifts the cooled pot over the wall to the process area. If a pot cannot be repaired, it is recycled for metal recovery (sent to Charleston Steel) after it is cleaned out. The building has an air pollution control unit to remove particles from the air. Particles generated by the air pollution control unit (baghouse) are collected in a hazardous waste container. The container was larger than 55 gallons; was dated June 7, 2024; had a hazardous waste label, and at the bottom of the label it read "contains hazardous or toxic waste" but was missing its hazard marking. The hazardous waste label was also determined to incorrectly list the material in the container as a liquid waste that was a hazardous waste liquid, when it actually contained a solid (Photographs 33-34). Facility staff put the correct hazardous waste label on the container (Photograph 35). The new label did note
EPA-RCRA CEI Report June 26, 2024
Page 8 of 76
Century Aluminum of South Carolina SCD097366165
that the container contained hazardous waste, but the container did not have a hazard marking or indicator of the type of hazard.
Pursuant to S.C. Code Ann. Regs. 61-79.262.17(a)(5)(i)(B) [40 C.F.R. 262.17(a)(5)(i)(B)], which is a condition of the LQG permit exemption, a generator must mark or label its container with an indication of the hazards of the contents (examples include, but are not limited to, the applicable hazardous waste characteristic(s) (i.e., ignitable, corrosive, reactive, toxic); hazard communication consistent with the Department of Transportation requirements at 49 CFR part 172 subpart E (labeling) or subpart F (placarding); a hazard statement or pictogram consistent with the Occupational Safety and Health Administration Hazard Communication Standard at 29 C.F.R. 1910.1200; or a chemical hazard label consistent with the National Fire Protection Association code 704).
At the time of the inspection, the inspectors observed:
a small hole in the wall and loose metal siding on Building 138, that had led to a release of hazardous waste (K088) to the environment in the area immediately adjacent to the hole and loose siding (Photograph 36);
the roll-up vehicle door on Building 138 would not close due to a buildup of hazardous waste (K088) at the edges of the door, and hazardous waste (K088) appeared to be escaping to the environment through the gap created by the improperly maintained roll-up vehicle door;
the metal siding near the roll-up vehicle door was bent and damaged, which appeared to have resulted in a gap, allowing the release of hazardous waste (K088) to the environment immediately outside of Building 138 (Photographs 37-38); and
the emergency contact information was not posted on the exterior of Building 138.
Pursuant to S.C. Code Ann. Regs. 61-79.262.17(a)(4) [40 C.F.R. 262.17(a)(4)], which incorporates S.C. Code Ann. Regs. 61-79.265.1101(c)(1) [40 C.F.R. 265.1101(c)(1)], and is a condition of the LQG Permit Exemption, owners or operators of all containment buildings must: (1) Use controls and practices to ensure containment of the hazardous waste within the unit; and, at a minimum: (i) Maintain the primary barrier to be free of significant cracks, gaps, corrosion, or other deterioration that could cause hazardous waste to be released from the primary barrier; (ii) Maintain the level of the stored/treated hazardous waste within the containment walls of the unit so that the height of any containment wall is not exceeded; (iii) Take measures to prevent the tracking of hazardous waste out of the unit by personnel or by equipment used in handling the waste. An area must be designated to decontaminate equipment and any rinsate must be collected and properly managed; and (iv) Take measures to control fugitive dust emissions such that any openings (doors, windows, vents, cracks, etc.) exhibit no visible emissions. In addition, all associated particulate collection devices (e.g., fabric filter, electrostatic precipitator) must be operated and maintained with sound air pollution control practices. This state of no visible emissions must be maintained effectively
EPA-RCRA CEI Report June 26, 2024
Page 9 of 76
Century Aluminum of South Carolina SCD097366165
at all times during normal operating conditions, including when vehicles and personnel are entering and exiting the unit.
Pursuant to S.C. Code Ann. Regs. 61-79.262.17(a)(4) [40 C.F.R. 262.17(a)(4)], which incorporates S.C. Code Ann. Regs. 61-79.265.1101(c)(3) [40 C.F.R. 265.1101(c)(3)], throughout the active life of the containment building, if the owner or operator detects a condition that could lead to or has caused a release of hazardous waste, the owner or operator must repair the condition promptly, in accordance with the following procedures: (i) Upon detection of a condition that has led to a release of hazardous waste (e.g., upon detection of leakage from the primary barrier) the owner or operator must: (A) Enter a record of the discovery in the facility operating record; (B) Immediately remove the portion of the containment building affected by the condition from service; (C) Determine what steps must be taken to repair the containment building, remove any leakage from the secondary collection system, and establish a schedule for accomplishing the cleanup and repairs; and (D) Within 7 days after the discovery of the condition, notify the Department (SCDES) of the condition, and within 14 working days, provide a written notice to SCDES with a description of the steps taken to repair the containment building, and the schedule for accomplishing the work.
The inspectors inspected the CAA Roll-off containers for K088 hazardous waste. These five 20yard metal containers were closed and properly labeled and marked. However, the containers are over 200 yards from Building 138 and this distance precludes this area from being classified as part of Building 138 CAA (Photograph 39). This area is required to be a separate CAA.
SAA SA-19D was inspected. This SAA is in the maintenance area for the cast house area. This SAA had an aerosol can puncturing device on top of a 55-gallon metal container. The 55-gallon metal container was labeled as hazardous waste and had an appropriate hazard marking (Photograph 40).
SAA SA-24 was inspected. This area accumulates hazardous waste (D038) pitch residue generated from the production process. Due to moving machinery, the inspection team could not approach close to the metal 55-gallon container but observed it from a distance of about 20 feet. The container appeared to be properly closed, labeled, and marked. The inspectors decided not to have a photograph taken of the container since this container was in an active production area with moving machinery. This area only contained the single 55-gallon container at the time of the inspection.
12) Records Review
At the time of the inspection, the inspection team reviewed hazardous waste manifests, land disposal restriction notifications, inspection records, training, and the Contingency Plan. Some records were emailed to the inspection team after the inspection. This included waste
EPA-RCRA CEI Report June 26, 2024
Page 10 of 76
Century Aluminum of South Carolina SCD097366165
determinations for the oil contaminated debris, training records and job description for the environmental manager, and training records for other facility personnel.
On July 24, 2024, the inspectors received a letter from the facility, which included: multiple EPA Acknowledgement of Consent pertaining to the exports of K088 hazardous waste; a Professional Engineer (PE) certification, from February 5, 2004, of the Containment Building (Building 138); available weekly inspections records documenting inspections of the Containment Building (Building 138) conducted during April 2022, February 2023, and March 2024; and documentation that the pile of material in Building 139 had been present for approximately a year.
Hazardous Waste Manifests The hazardous waste manifests and land disposal notifications for 2022, 2023, and 2024 were inspected. No issues with the hazardous waste manifests or land disposal notifications were identified.
Contingency Plan At the time of the inspection, the inspectors reviewed the facility-specific Contingency Plan dated October 2020. The inspectors observed that the Contingency Plan did not include the location of the hazardous waste roll-off containers on the map and the facility did not have a Quick Reference Guide (QRG). The copies of the agreements with local emergency responders was missing from the Contingency Plan's Appendix C, but copies were later found during the inspection documenting that the Contingency Plan had been sent out on July 27, 2020, on November 23, 2020, and May 4, 2021. The facility did not have a QRG to submit to the local emergency responders. The 2020 Contingency Plan was produced before the Mt. Holly Plant was temporarily idled and some of the former safety and emergency response equipment (Fire Truck and Ambulance) and personnel (fire personnel) are no longer on site or may be inactive. The Contingency Plan must be updated to better organize the plans so that information is more readily found, to delete equipment that was no longer on site or in use, and to include a QRG.
Pursuant to S.C. Code Ann. Regs. 61-79.262.17(a)(6) [40 C.F.R. 262.17(a)(6)], which incorporates S.C. Code Ann. Regs. 61-79.262.262(b)) [40 C.F.R. 262.262(b)], and is a condition of the LQG Permit Exemption, a generator that first becomes subject to these provisions after May 30, 2017, or a large quantity generator that is otherwise amending its contingency plan must at that time submit a quick reference guide of the contingency plan to the local emergency responders identified at paragraph (a) of this section or, as appropriate, the Local Emergency Planning Committee.
EPA-RCRA CEI Report June 26, 2024
Page 11 of 76
Century Aluminum of South Carolina SCD097366165
Weekly Inspections Records The inspectors reviewed the weekly inspection records for the Container CAA from January 2022 to May 2024 and observed:
weekly inspection records from July 20, 2022, through December 7, 2022, were missing (approximately four and a half months of inspection records);
three inspection forms in 2024 were missing the signature, date, and time; and five different inspection forms in 2024 were missing the date.
Pursuant to S.C. Code Ann. Regs. 61-79.262.17(a)(1)(v)) [40 C.F.R. 262.17(a)(1)(v)], which is a condition of the LQG permit exemption, at least weekly the generator must inspect central accumulation areas.
The inspectors reviewed the weekly inspection records for the Containment CAA (Building 138) for April 2022, February 2023, and March 2024, and observed:
three weekly inspection records were not recorded in April 2022; two weekly inspection records were not recorded in February 2023; and one inspection record was missing for March 2024.
The Containment Building CAA (Building 138) inspection sheets included documentation of how many pots were processed during the week, how many containers of Spent Pot Liner waste were shipped, the condition of any waste in the accumulation area, the housekeeping status of Building 138, and the structural integrity of Building 138, the weather conditions, emergency communications operable, firefighting equipment available and operable, and the overall condition of the area as either satisfactory or unsatisfactory.
Some of the Containment Building inspection sheets did not appear to be completely or correctly filled out. None of the inspection sheets had the time filled in the "Date and Time" block. The date was entered on the sheets, but not the time. It was noted on the April 6, 2022, inspection sheet that the date for when 90 days will be reached was not filled in. On the question "Building roof and walls are free of damage?", that was answered "No". The dates for the questions "Oldest shipping container date", "Date will reach 90 days", and "Last room cleanout date?" were all lacking the date. On all of the inspection sheets the rating of satisfactory was circled. It is recommended that the facility review the inspection procedures and training to address these issues.
For the Building 138 CAA, three inspection sheets for March 2024 all noted, as observed during the June 26, 2024, inspection, that the area outside of containment was not free of K088 material. This condition was documented on the March 6, 2024, March 13, 2024, and March 20, 2024, inspections and was still present on June 26, 2024. The overall condition for Building 138 was marked "Satisfactory." No notification was made to the South Carolina Department of Environmental Services.
EPA-RCRA CEI Report June 26, 2024
Page 12 of 76
Century Aluminum of South Carolina SCD097366165
Pursuant to S.C. Code Ann. Regs. 61-79.262.17(a)(4) [40 C.F.R. 262.17(a)(4)], which incorporates S.C. Code Ann. Regs. 61-79.265.1101(c)(4) [40 C.F.R. 265.1101(c)(4)], and is a condition of the LQG Permit Exemption, owners and operators of all containment buildings must inspect and record in the facility's operating record at least once every seven days data gathered from monitoring and leak detection equipment as well as the containment building and the area immediately surrounding the containment building to detect signs of releases of hazardous waste.
Pursuant to S.C. Code Ann. Regs. 61-79.262.17(a)(4) [40 C.F.R. 262.17(a)(4)], which incorporates S.C. Code Ann. Regs. 61-79.265.1101(c)(3) [40 C.F.R. 265.1101(c)(3)], and is a condition of the LQG Permit Exemption, for containment buildings (i) Upon detection of a condition that has led to a release of hazardous waste (e.g., upon detection of leakage from the primary barrier) the owner or operator must: (A) Enter a record of the discovery in the facility operating record; (B) Immediately remove the portion of the containment building affected by the condition from service; (C) Determine what steps must be taken to repair the containment building, remove any leakage from the secondary collection system, and establish a schedule for accomplishing the cleanup and repairs; and (D) Within 7 days after the discovery of the condition, notify the Department of the condition, and within 14 working days, provide a written notice to the Department with a description of the steps taken to repair the containment building, and the schedule for accomplishing the work.
The inspectors reviewed the brief one-page Professional Engineer (PE) Certification "SPL Containment at Building 138" dated February 5, 2004. The inspectors observed that the PE Certification:
only reviewed a portion of Containment Building 138, specifically the portion related to Capital Project MH00-140, which provided decontamination areas to Containment Building 138 for the removal of spent pot lining (SPL) from personnel and equipment prior to leaving the existing containment building;
does not have any supporting documentation or calculations or analysis; and lacks any statement on examining the required areas other than not observing visible
emissions. The PE certification does not address the required elements of S.C. Code Ann. Regs. 61-79.265.1101 [40 C.F.R. 265.1101]. The PE certification is silent on if any other areas, other than "no visible emissions", were evaluated; and, lacks any information addressing design standards established by professional organizations generally recognized by the industry such as, American Concrete Institute (ACI) and the American Society of Testing Materials (ASTM).
In addition, given that the building and related waste management activity (in regard to maintenance issues and releases of K088 hazardous waste) is no longer in compliance with S.C. Code Ann. Regs. 61-79.262.17(a)(4) [40 C.F.R. 262.17(a)(4)], which incorporates S.C. Code Ann. Regs. 61-79.265.1100 and 1101 [40 C.F.R. 265.1100 and 1101], and the amount of time that has transpired since the last certification, a new PE certification of the repaired building
EPA-RCRA CEI Report June 26, 2024
Page 13 of 76
Century Aluminum of South Carolina SCD097366165
that fully complies with S.C. Code Ann. Regs. 61-79.262.17(a)(4)(i) [40 C.F.R. 262.17(a)(4)(i)], is required to maintain the generator exemption for operating a containment building.
Pursuant to S.C. Code Ann. Regs. 61-79.262.17(a)(4)(i) [40 C.F.R. 262.17(a)(4)(i)], and is a condition of the LQG Permit Exemption, a generator is required to have a professional engineer certification stating that the containment building complies with the design standards specified in S.C. Code Ann. Regs. 61-79.265.1101 [40 C.F.R. 265.1101]. This certification must be in the generator's files prior to operation of the unit.
The inspectors requested the hazardous waste determination and/or the Safety Data Sheet (SDS) on the waste pile and the material in the supersacks in Building 139. The facility provided a Solid Waste Determination and SDS to the inspectors via email on July 24, 2024. The Solid Waste Determination was dated October 3, 2013, and addressed the Waste Bath material but not the compromised super sacks. The SDS, issued on January 5, 2011, was for unused cryolite. The Century Aluminum SDS provided to the inspectors for the Crushed Bath material notes the health hazard risk for the material is a 1. It notes that the material has no potential toxic effects. It also has no cautions on firefighting or transportation and notes that the material is not regulated under CFR 49.
SDS from other companies for Cryolite materials are substantially different. For example, the toxicity rating is Category 4. Label requirements and precautionary statements are present in those SDSs that are absent from the Century Aluminum SDS provided to the inspectors. The other SDSs note that when working with cryolite, when engineering controls are not sufficient, respiratory protection is required. Inhaling cryolite can potentially cause death or serious injury and cryolite is hazardous to the skin. Cryolite is also toxic to aquatic life.
Based on the information provided by the facility, the main ingredient in the supersacks and for the waste bath was Cryolite (Sodium Hexafluoroaluminate). This information supported that approximately 80% of the material in Building 139 was cryolite. This cryolite is mixed with waste carbon, waste coke, and other contaminants that it may come in contact with or mix with. Cryolite must be kept dry and away from any water sources that could convey cryolite into watersheds or water supplies. Cryolite is a hazardous material that is an inhalation and skin hazard and is highly toxic to aquatic life. The facility's solid waste determination is devoid of any warnings or information on the hazards of the material that is being sent to a solid waste disposal site. The solid waste determination is also lacking any analytical data.
In the facility's July 24, 2024, letter, the facility noted, "The supersacks of material in Building 139 has been there roughly two years and is the by-product Crushed Bath that is stored for use internally or sold." Given the status of the building (the compromised roof) and the large amount of liquids on the floor, and that Crushed Bath Materials (in the supersacks) have been there for two years, it is not clear if the materials are still viable. These conditions are a concern and can call into question whether the material in the supersacks is still a viable product.
EPA-RCRA CEI Report June 26, 2024
Page 14 of 76
Century Aluminum of South Carolina SCD097366165
Pursuant to S.C. Code Ann. Regs. 61-79.262.11 [40 C.F.R. 262.11], A person who generates a solid waste, as defined in S.C. Code Ann. Regs. 61-79.261.2 [40 C.F.R. 262.11], must make an accurate determination as to whether that waste is a hazardous waste in order to ensure wastes are properly managed according to applicable RCRA regulations.
The inspectors reviewed the September 9, 2005, nonhazardous waste profile completed for "Miscellaneous Oil Sludges" generated from the clean-out of oil water separators and machinery at Alumax of South Carolina (a former name of Century Aluminum) going to the Ashland Distribution for disposal. This profile was provided on July 3, 2024, as a waste determination for the "Non-Pumpable Oil" observed at the time of the inspection. The waste name noted on the profile was "Misc. Oil Sludges". Based on the leak, this material appears to have some portion of free-flowing used oil in it. The profile is dated September 8, 2005, and does not include analytical results. On the profile there is a block for 50-99% free liquids that is not checked. However, it is implied that there are probably some free liquids in the waste due to the composition being listed as 1-50% emulsified oil solids, 50-99% water, and 0-50% antifreeze. Due to the age of the waste profile, and the lack of any analytical analysis, the profile may not be an accurate hazardous waste determination.
Pursuant to S.C. Code Ann. Regs. 61-79.262.11 [40 C.F.R. 262.11], A person who generates a solid waste, as defined in S.C. Code Ann. Regs. 61-79.261.2 [40 C.F.R. 262.11], must make an accurate determination as to whether that waste is a hazardous waste in order to ensure wastes are properly managed according to applicable RCRA regulations.
Training On July 3, 2024, the facility submitted training records for 2023 and 2024. The inspectors reviewed the records. No training issues were identified in the review.
13) Closing Conference and Follow-up
The inspectors conducted the exit meeting with Mr. Coleman, Mr. Alsten, and Mr. Brown. During this exit briefing Ms. Steinunn Dgg Steinsen (Corporate Vice President, Health, Safety, and Environment, Century Aluminum) joined via telephone. During this meeting, the EPA and SCDES presented the preliminary results of the inspection, including the concerns about releases from Containment Building 138. Additional records were requested and promptly sent by Century Aluminum following the on-site inspection. Century Aluminum was inspected as an LQG.
14) Summary of Observations
During the inspection, observations were made concerning the following RCRA requirements:
Pursuant to S.C. Code Ann. Regs. 61-107.279(c)(1) [40 C.F.R. 279.22(c)(1)], containers
EPA-RCRA CEI Report June 26, 2024
Page 15 of 76
Century Aluminum of South Carolina SCD097366165
and aboveground tanks used to store used oil at generator facilities must be labeled or marked clearly with the words "Used Oil."
SA-1 had a plastic 55-gallon used oil container and a metal 55-gallon used oil container. Neither container had a "Used Oil" label.
Pursuant to S.C. Code Ann. Regs. 61-79.262.15(a)(4) [40 C.F.R. 262.15(a)], which is a condition of the LQG permit exemption, an SAA container holding hazardous waste must be closed at all times during accumulation, except: (i) When adding, removing, or consolidating waste; or (ii) When temporary venting of a container is necessary (A) For the proper operation of equipment, or (B) To prevent dangerous situations, such as build-up of extreme pressure.
Building 270 has an SAA for the Carbon Maintenance. SA-2 had an aerosol can puncturing device that had a hazardous waste label and hazard marking. The device was open at the time of the inspection but was immediately closed by Century Aluminum staff.
Pursuant to S.C. Code Ann. Regs. 61-79.273.14(e) [40 C.F.R. 273.14(e)], an SQHUW must label or mark the universal waste lamps to identify the type of universal waste.
Pursuant to S.C. Code Ann. Regs. 61-79.273.15(c) [40 C.F.R. 273.15(c)], an SQHUW who accumulates universal waste must be able to demonstrate the length of time that universal waste has been accumulated from the date it became a waste or is received.
SA-2A had a 5-foot container of universal waste lamps that was not labeled or dated.
Pursuant to S.C. Code Ann. Regs. 61-107.279(d) [40 C.F.R. 279.22(d)], generators of used oil upon discovery of a release of used oil must stop the release, contain the released used oil, clean up the used oil, and make any necessary repairs or replacements to the container or tank.
Pursuant to S.C. Code Ann. Regs. 61-107.279(c)(1) [40 C.F.R. 279.22(c)(1)], containers and aboveground tanks used to store used oil at generator facilities must be labeled or marked clearly with the words "Used Oil."
The Container CAA had three 300-gallon tote tanks that were labeled as non-hazardous waste containing non-pumpable oil from maintenance activities. Two of the tote tanks were full and one was half full. The tote tanks were not labeled as "Used Oil" but were labeled as "Non-Pumpable Oil" and being managed as a non-hazardous waste. At the time of the inspection, the inspectors observed a leak of a black liquid that appeared to be a used oil leak originating from under one of the tote tanks.
EPA-RCRA CEI Report June 26, 2024
Page 16 of 76
Century Aluminum of South Carolina SCD097366165
Pursuant to S.C. Code Ann. Regs. 61-79.273.15(c) [40 C.F.R. 273.15(c)], an SQHUW who accumulates universal waste must be able to demonstrate the length of time that universal waste has been accumulated from the date it became a waste or is received.
In the Container CAA there were four 4-foot tube containers of universal waste lamps that were closed and labeled but the containers were missing the accumulation dates.
Pursuant to S.C. Code Ann. Regs. 61-107.279(c)(1) [40 C.F.R. 279.22(c)(1)], containers and aboveground tanks used to store used oil at generator facilities must be labeled or marked clearly with the words "Used Oil."
In the Container CAA, a 3-gallon container for collecting used oil from the used oil pumps' operations, was present but was not closed or labeled as "Used Oil".
Pursuant to S.C. Code Ann. Regs. 61-79.262.17(a)(1)(ii) [40 C.F.R. 262.17(a)(1)(ii)], which is a condition of the LQG permit exemption, if a container holding hazardous waste is not in good condition, or if it begins to leak, the LQG must immediately transfer the waste to a container that is in good condition or manage the waste in some other way that complies with the exemption requirements.
The facility had shipped its hazardous waste from the Container CAA on Tuesday, June 25, 2024. At the time of the inspection, the inspectors observed one metal 30-gallon container of ignitable (D001) hazardous waste dated April 23, 2024, remaining in the Container CAA. The other hazardous waste containers had been shipped on June 25, 2024. This container was in poor condition as evidenced by being completely coated in rust.
Pursuant to S.C. Code Ann. Regs. 61-79.262.15(a)(5)(ii) [40 C.F.R. 262.15(a)(5)(ii)], which is a condition of the LQG permit exemption, a generator must mark or label its container with the following: (ii) An indication of the hazards of the contents (examples include, but are not limited to, the applicable hazardous waste characteristic(s) (i.e., ignitable, corrosive, reactive, toxic); hazard communication consistent with the Department of Transportation requirements at 49 CFR part 172 subpart E (labeling) or subpart F (placarding); a hazard statement or pictogram consistent with the Occupational Safety and Health Administration Hazard Communication Standard at 29 C.F.R. 1910.1200; or a chemical hazard label consistent with the National Fire Protection Association code 704).
The inspectors observed, a Connex adjacent to the CAA. Inside the Connex the inspectors observed a metal 55-gallon container of broken lamps being managed as toxic (D009) hazardous waste. The container was labeled as containing hazardous waste
EPA-RCRA CEI Report June 26, 2024
Page 17 of 76
Century Aluminum of South Carolina SCD097366165
but was not marked or labeled with an indication of the hazard of its contents
Pursuant to S.C. Code Ann. Regs. 61-79.273.13(d)(1) [40 C.F.R. 273.13(d)(1)], a small quantity handler of universal waste must contain any lamp in containers or packages that are structurally sound, adequate to prevent breakage, and compatible with the contents of the lamps. Such containers and packages must remain closed and must lack evidence of leakage, spillage or damage that could cause leakage under reasonably foreseeable conditions.
In the Connex near the Container CAA, there was a 6-foot container and two other universal lamp containers in the Connex that were open.
Pursuant to S.C. Code Ann. Regs. 61-79.262.15(a)(5)(i)(B) [40 C.F.R. 262.15(a)(5)(i)(B)], which is a condition of the LQG permit exemption, a generator must mark or label its container with the following: (i) The words "Hazardous Waste" and (ii) An indication of the hazards of the contents (examples include, but are not limited to, the applicable hazardous waste characteristic(s) (i.e., ignitable, corrosive, reactive, toxic); hazard communication consistent with the Department of Transportation requirements at 49 CFR part 172 subpart E (labeling) or subpart F (placarding); a hazard statement or pictogram consistent with the Occupational Safety and Health Administration Hazard Communication Standard at 29 CF 1910.1200; or a chemical hazard label consistent with the National Fire Protection Association code 704).
There was a metal hazardous waste container in Building 138 had a hazardous waste label but was missing its hazard marking.
Pursuant to S.C. Code Ann. Regs. 61-79.262.17(a)(4) [40 C.F.R. 262.17(a)(4)], which incorporates S.C. Code Ann. Regs. 61-79.265.1101(c)(1) [40 C.F.R. 265.1101(c)(1)], and is a condition of the LQG Permit Exemption, owners or operators of all containment buildings must: (1) Use controls and practices to ensure containment of the hazardous waste within the unit; and, at a minimum: (i) Maintain the primary barrier to be free of significant cracks, gaps, corrosion, or other deterioration that could cause hazardous waste to be released from the primary barrier; (ii) Maintain the level of the stored/treated hazardous waste within the containment walls of the unit so that the height of any containment wall is not exceeded; (iii) Take measures to prevent the tracking of hazardous waste out of the unit by personnel or by equipment used in handling the waste. An area must be designated to decontaminate equipment and any rinsate must be collected and properly managed; and (iv) Take measures to control fugitive dust emissions such that any openings (doors, windows, vents, cracks, etc.) exhibit no visible emissions. In addition, all associated particulate collection devices (e.g., fabric filter, electrostatic precipitator) must be operated and maintained
EPA-RCRA CEI Report June 26, 2024
Page 18 of 76
Century Aluminum of South Carolina SCD097366165
with sound air pollution control practices. This state of no visible emissions must be maintained effectively at all times during normal operating conditions, including when vehicles and personnel are entering and exiting the unit.
Pursuant to S.C. Code Ann. Regs. 61-79.262.17(a)(4) [40 C.F.R. 262.17(a)(4)], which incorporates S.C. Code Ann. Regs. 61-79.265.1101(c)(3) [40 C.F.R. 265.1101(c)(3)], throughout the active life of the containment building, if the owner or operator detects a condition that could lead to or has caused a release of hazardous waste, the owner or operator must repair the condition promptly, in accordance with the following procedures: (i) Upon detection of a condition that has led to a release of hazardous waste (e.g., upon detection of leakage from the primary barrier) the owner or operator must: (A) Enter a record of the discovery in the facility operating record; (B) Immediately remove the portion of the containment building affected by the condition from service; (C) Determine what steps must be taken to repair the containment building, remove any leakage from the secondary collection system, and establish a schedule for accomplishing the cleanup and repairs; and (D) Within 7 days after the discovery of the condition, notify the Department (SCDES) of the condition, and within 14 working days, provide a written notice to SCDES with a description of the steps taken to repair the containment building, and the schedule for accomplishing the work.
There was a small hole in the wall, and loose metal siding on Building 138, that had led to a release of hazardous waste (K088) to the environment in the area immediately adjacent to the hole and loose siding. The roll-up vehicle door on Building 138 would not close due to a buildup of hazardous waste (K088) at the edges of the door. Hazardous waste (K088) appeared to be escaping to the environment through the gap created by the improperly maintained roll-up vehicle door the metal siding near the roll-up vehicle door was bent and damaged, which appeared to have resulted in a gap, allowing the release of hazardous waste (K088) to the environment immediately outside of Building and the emergency contact information was not posted on the exterior of the building.
Pursuant to S.C. Code Ann. Regs. 61-79.262.262(b)) [40 C.F.R. 262.262(b)], A large quantity generator that first becomes subject to these provisions after May 30, 2017, or a large quantity generator that is otherwise amending its contingency plan must at that time submit a quick reference guide of the contingency plan to the local emergency responders identified at paragraph (a) of this section or, as appropriate, the Local Emergency Planning Committee.
The facility did not have a Quick Reference Guide (QRG). The facility did not have a QRG to submit to the local emergency responders.
Pursuant to S.C. Code Ann. Regs. 61-79.262.17(a)(1)(v)) [40 C.F.R. 262.17(a)(1)(v)],
EPA-RCRA CEI Report June 26, 2024
Page 19 of 76
Century Aluminum of South Carolina SCD097366165
which is a condition of the LQG permit exemption, at least weekly the generator must inspect central accumulation areas.
The weekly inspection records for July 20, 2022, through December 7, 2022, were missing (approximately 4 & months of inspection records). Three inspection forms in 2024 were missing the signature, date, and time, and five inspection forms were missing the date.
Pursuant to S.C. Code Ann. Regs. 61-79.262.17(a)(4) [40 C.F.R. 262.17(a)(4)], which incorporates S.C. Code Ann. Regs. 61-79.265.1101(c)(4) [40 C.F.R. 265.1101(c)(4)], and is a condition of the LQG Permit Exemption, all containment buildings must be inspected at least once every seven days.
For the containment building three weekly inspection records were not recorded in April 2022, two weekly inspection records were not recorded in February 2023, and one inspection record was missing for March 2024.
Pursuant to S.C. Code Ann. Regs. 61-79.262.17(a)(4) [40 C.F.R. 262.17(a)(4)], which incorporates S.C. Code Ann. Regs. 61-79.265.1101(c)(3) [40 C.F.R. 265.1101(c)(3)], and is a condition of the LQG Permit Exemption, for containment buildings (i) Upon detection of a condition that has led to a release of hazardous waste (e.g., upon detection of leakage from the primary barrier) the owner or operator must: (A) Enter a record of the discovery in the facility operating record; (B) Immediately remove the portion of the containment building affected by the condition from service; (C) Determine what steps must be taken to repair the containment building, remove any leakage from the secondary collection system, and establish a schedule for accomplishing the cleanup and repairs; and (D) Within 7 days after the discovery of the condition, notify the Department of the condition, and within 14 working days, provide a written notice to the Department with a description of the steps taken to repair the containment building, and the schedule for accomplishing the work.
The three inspection sheets for Building 138 for March 2024 all noted, as observed during the June 26, 2024, inspection, that the area outside of containment was not free of K088 material. This condition was documented on the March 6, 2024, March 13, 2024, and March 20, 2024, inspections, and was still present during the June 26, 2024, inspection. The overall condition of the Containment Building was marked "Satisfactory". No notification was made to the South Carolina Department of Environmental Services.
Pursuant to S.C. Code Ann. Regs. 61-79.262.17(a)(4)(i) [40 C.F.R. 262.17(a)(4)(i)], and is a condition of the LQG Permit Exemption, a generator is required to have a professional engineer certification stating that the containment building complies
EPA-RCRA CEI Report June 26, 2024
Page 20 of 76
Century Aluminum of South Carolina SCD097366165
with the design standards specified in S.C. Code Ann. Regs. 61-79.265.1101 [40 C.F.R. 265.1101]. This certification must be in the generator's files prior to operation of the unit.
The brief one-page Professional Engineer (PE) Certification "SPL Containment at Building 138" dated February 5, 2004, was limited in its scope. The PE Certification only reviewed a portion of Containment Building 138, specifically the portion related to Capital Project MH00-140, which provided decontamination areas to Containment Building 138 for the removal of spent pot lining (SPL) from personnel and equipment prior to leaving the existing containment building. The certification does not have any supporting documentation or calculations or analysis; and lacks any statement on examining the required areas other than not observing visible emissions. The PE certification does not address the required elements of S.C. Code Ann. Regs. 61-79.265.1101 [40 C.F.R. 265.1101]. The PE certification is silent on if any other areas, other than "no visible emissions", were evaluated. The certification also lacks information addressing any of the design standards established by professional organizations generally recognized by the industry such as, American Concrete Institute (ACI) and the American Society of Testing Materials (ASTM)
Pursuant to S.C. Code Ann. Regs. 61-79.262.11 [40 C.F.R. 262.11], A person who generates a solid waste, as defined in S.C. Code Ann. Regs. 61-79.261.2 [40 C.F.R. 262.11], must make an accurate determination as to whether that waste is a hazardous waste in order to ensure wastes are properly managed according to applicable RCRA regulations.
Based on the liquids leaking from the non-pumpable oil containers, this material appears to have some portion of free-flowing used oil in it. The profile is dated September 8, 2005, and does not have any analytical results on the waste. Due to the age of the waste profile and the lack of any analytical analysis, the profile is not a valid hazardous waste determination.
Pursuant to S.C. Code Ann. Regs. 61-79.262.11 [40 C.F.R. 262.11], A person who generates a solid waste, as defined in S.C. Code Ann. Regs. 61-79.261.2 [40 C.F.R. 262.11], must make an accurate determination as to whether that waste is a hazardous waste in order to ensure wastes are properly managed according to applicable RCRA regulations.
The October 3, 2013, solid waste determination for the waste bath material was reviewed. The facility's solid waste determination does not adequately reflect the hazards of the waste material being managed. Since the material is primarily cryolite, precautions must be taken when working with the material and shipping it for disposal. According to the solid waste determination this was to characterize the cryolite bath
EPA-RCRA CEI Report June 26, 2024
Page 21 of 76
Century Aluminum of South Carolina SCD097366165
material that has spilled on the ground and is periodically cleaned up. No hazardous waste determination was provided.
15) List of Attachments
Attachment A - Photo Log Attachment B - February 5, 2004, PE Certification of the Containment Building Attachment C - Crushed Bath Safety Data Sheet Attachment D - Waste Bath Solid Waste Determination Attachment E - Safety Data Sheet for Cryolite Attachment F - Weekly inspection sheets (for three months) for the Building 138 CAA
16) Signed
GEORGE MCBROOM
for Robert S. Nakamoto Environmental Engineer RCRA Enforcement Section
Digitally signed by GEORGE MCBROOM Date: 2025.01.10 11:14:35 -05'00'
17) Concurrence
BROOKE YORK Date: 2025.01.10 11:48:29 -05'00' Digitally signed by BROOKE YORK
Brooke York Acting Chief RCRA Enforcement Section
EPA-RCRA CEI Report June 26, 2024
Page 22 of 76
Century Aluminum of South Carolina SCD097366165
ATTACHMENT A
Century Aluminum of South Carolina Mt. Holly Plant
Goose Creek, South Carolina
COMPLIANCE EVALUATION INSPECTION PHOTOGRAPHS
June 26, 2024
Photographs taken by Century Aluminum Staff
EPA-RCRA CEI Report June 26, 2024
Page 23 of 76
Century Aluminum of South Carolina SCD097366165
Photograph 1: SA-1, Two unlabeled Used Oil Containers.
Photograph 2: SA-1A, 4-Foot UW Lamp Container and 5-gallon UW Battery Container.
EPA-RCRA CEI Report June 26, 2024
Page 24 of 76
Century Aluminum of South Carolina SCD097366165
Photograph 3: Label on the UW Battery Container.
Photograph 4: Label on the UW Lamp Container.
EPA-RCRA CEI Report June 26, 2024
Page 25 of 76
Century Aluminum of South Carolina SCD097366165
Photograph 5: SA-2, Building 270, Aerosol Puncturing SAA container.
Photograph 6: SA-2, Building 270, Aerosol Puncturing SAA container, after closing the lid.
EPA-RCRA CEI Report June 26, 2024
Page 26 of 76
Century Aluminum of South Carolina SCD097366165
Photograph 7: SA-2, Building 270, Top of the Aerosol Puncturing SAA container.
Photograph 8: UW Containers, 5-foot UW Lamp Container is not labeled.
EPA-RCRA CEI Report June 26, 2024
Page 27 of 76
Century Aluminum of South Carolina SCD097366165
Photograph 9: SA-2A, UW Battery Containers, Containers Labeled and Dated.
Photograph 10: SA-2A, Two 4-foot UW Lamp Containers near oily rag containers.
EPA-RCRA CEI Report June 26, 2024
Page 28 of 76
Century Aluminum of South Carolina SCD097366165
Photograph 11: Building 139, Pile of Bath Salts Material and Supersacks of Crushed Bath Material Containing Cryolite. Maintenance issues are visible with the roof and clear liquid is covering a significant portion, approximately half, of the visible floor.
EPA-RCRA CEI Report June 26, 2024
Page 29 of 76
Century Aluminum of South Carolina SCD097366165
Photograph 12: Building 139, Second view of the pile of Bath Salts Material and Supersacks of Crushed Bath Material Containing Cryolite. More super sacks are visible along the rear of the building to the left.
EPA-RCRA CEI Report June 26, 2024
Page 30 of 76
Century Aluminum of South Carolina SCD097366165
Photograph 13: CAA, Three 300-gallon tote-tanks of Non-Pumpable Oil Material.
Photograph 14: Label on a non-pumpable oil container.
EPA-RCRA CEI Report June 26, 2024
Page 31 of 76
Century Aluminum of South Carolina SCD097366165
Photograph 15: Used oil release in the CAA area.
Photograph 16: 4-Foot UW Lamp containers that are closed and labeled but not dated.
EPA-RCRA CEI Report June 26, 2024
Page 32 of 76
Century Aluminum of South Carolina SCD097366165
Photograph 17: Two 5,000-gallon used oil tanks that are labeled as used oil.
Photograph 18: Used oil container for pump operations that is not closed or labeled.
EPA-RCRA CEI Report June 26, 2024
Page 33 of 76
Century Aluminum of South Carolina SCD097366165
Photograph 19: Used oil draining device.
Photograph 20: Two 55-gallon containers of oil debris.
EPA-RCRA CEI Report June 26, 2024
Page 34 of 76
Century Aluminum of South Carolina SCD097366165
Photograph 21: Label on 55-gallon container of oily debris.
Photograph 22: Containers of Oil & Grease debris.
EPA-RCRA CEI Report June 26, 2024
Page 35 of 76
Century Aluminum of South Carolina SCD097366165
Photograph 23: Containers of Oil & Grease debris.
Photograph 24: Damaged container of oil & grease debris.
EPA-RCRA CEI Report June 26, 2024
Page 36 of 76
Century Aluminum of South Carolina SCD097366165
Photograph 25: Oil and grease debris drum that is Significantly bulging at the top of the container.
Photograph 26: 30-gallon Metal hazardous waste container that has a significant amount of rusted area.
EPA-RCRA CEI Report June 26, 2024
Page 37 of 76
Century Aluminum of South Carolina SCD097366165
Photograph 27: Label on the 30-gallon HW container.
Photograph 28: 55-gallon HW Container of broken lamps that requires a hazard marking.
EPA-RCRA CEI Report June 26, 2024
Page 38 of 76
Century Aluminum of South Carolina SCD097366165
Photograph 29: Connex container for UW. Three UW lamp containers are not fully closed.
Photograph 30: Connex container for UW. Three UW lamp containers are not fully closed.
EPA-RCRA CEI Report June 26, 2024
Page 39 of 76
Century Aluminum of South Carolina SCD097366165
Photograph 31: Building 138 interior.
Photograph 32: Building 138, Pot repair and cleaning area.
EPA-RCRA CEI Report June 26, 2024
Page 40 of 76
Century Aluminum of South Carolina SCD097366165
Photograph 33: HW SAA for dust collection. Container was mistakenly labeled as a liquid waste.
Photograph 34: Second view of the K088 dust collector.
EPA-RCRA CEI Report June 26, 2024
Page 41 of 76
Century Aluminum of South Carolina SCD097366165
Photograph 35: Corrected hazardous waste label on the SAA Dust Collector. No hazard indicator is on the container.
Photograph 36: Small hole in the wall of Building 138 and loose siding near the building's foundation. A small release of K088 hazardous waste is shown.
EPA-RCRA CEI Report June 26, 2024
Page 42 of 76
Century Aluminum of South Carolina SCD097366165
Photograph 37: Building 138, loose siding with a small release of K088 hazardous waste.
Photograph 38: Roll-up vehicle door on Building 138 will not close due to a build-up of K088 hazardous waste at the sides of the door.
EPA-RCRA CEI Report June 26, 2024
Page 43 of 76
Century Aluminum of South Carolina SCD097366165
Photograph 39: HW Roll-off container of K088 Hazardous waste. The containers are closed, labeled And marked but are over 200 yards away from the Building 138 CAA.
Photograph 40: SA-19D HW SAA Container
EPA-RCRA CEI Report June 26, 2024
Page 44 of 76
Century Aluminum of South Carolina SCD097366165
Attachment B February 5, 2004, PE Certification of the Containment Building
EPA-RCRA CEI Report June 26, 2024
Page 45 of 76
Century Aluminum of South Carolina SCD097366165
LOCKWOOD GREENE
ENGINEFRING & CONSTRUCTION
PE CERTIFICATION
1300 International Drive (2930.'\) Post Office Box 491
Spartanburg, SC 29304-049'1 Telephone 864.378.2000 Facsimile 864.599.6400 www.lg.com
SPL CONTAINMENT AT BUILDING 138
CAPITAL PROJECT MH00-140 provided decontamination areas at Building 138, Pot Relining, for the removal of spent pot lining (SPL) from personnel and equipment prior ===to= =-leaving the-ex-isting RCRA containmentJmildig (dem9litiop. area). Specifically included were:
Construction of a building addition (approximately 40' x 25') to allow removal of Spent Pot Lining (SPL) from mobile equipment prior to this equipment exiting the demolition area of Building 138.
-- - - _--G0nstr-uGti0n=-ef-=-w0rk platf0irris-insi'ue-the::.n. ewaucliti0n=t- o-faeilitate-tne=cleaningof the equipment.
Construction of a new room adjacent to the demolition area to allow personnel to put on and remove PPE outside the demolition area.
Visual observations of the building, including the new additions, were made during the pot demolition process February 3 - 5, 2004. No visible emissions were observed. This is to certify that the building, based on these field observations, complies with containment building design and standards specified in 40 CFR 265.1101.
UL Donald R. Crowder
Project Manager PE 7201
Certification Date: 5 February 2004
EPA-RCRA CEI Report June 26, 2024
Page 46 of 76
DC:c:\docume~1\mscad\~1\locals~1\temp\inotes web access\00-140 pe certification.doc
Century Aluminum of South Carolina SCD097366165
Attachment C Crushed Bath Safety Data Sheet
EPA-RCRA CEI Report June 26, 2024
Page 47 of 76
Century Aluminum of South Carolina SCD097366165
Safety Data Sheet (SDS)
Print Date:
Issue Date:
CENTURY ALUMINUM OF KENTUCKY LLC
P.O. BOX 500 HAWESVILLE, KY 42348
5/10/2015
1/5/2011
CRUSHED BATH
Section 1: Product And Company Information
CENTURY ALUMINUM OF KENTUCKY LLC
Contact:
P.O. BOX 500
Emergency Phone:
(270) 927-6921
HAWESVILLE, KY 42348
Information Phone: (270) 627-6921
Trade Name; CRUSHED BATH Product Family: MIXTURE Recommended Uses Process by-product to be recycled
Synonym:
Section 2: Hazard Identification
GHS CLASSIFICATION
Health Hazards: N/G
Flammability: N/G
Reactivity:
N/G
Personal Protetion:
Non-Hazardous
1 1 1
Chronic
Physical Stat Not Given Solid e: Appearance: Grayish-White Solid
Gas
Liquid Other
Odor Slight Musty Odor
Route of Entry Ingestion
Skin/Eye Contact
Skin Absorption
Inhalation
N/A
Potential Health Effects: Toxic: Yes No Unknown
Reproductive Toxin Yes No Unknown Irritant: Yes No Unknown
Not Given Not Given Not Given
Corrosive: Carcinogen:
Sensitize:
Yes No Yes No Yes No
Unknown Unknown Unknown
Not Given Not Given Not Given
Irritating to: Skin
Eyes
Mucous Membranes Respiratory Tract Other:
Other Target Organs: None
Section 3: COMPOSITION/INFORMATION ON INGREDIENTS
CHEMICAL COMPONENT
aluminum oxide calcium fluoride
cryolite iron
lithium fluoride silicon
TLV
2.50 5.00
PEL
5.00
5.00
MEASURE
mg/m3 mg/m3
mg/m3
RANGE
Y Y Y Y Y Y
%MIN %MIX
2.50 4.00 5.50 8.00 84.50 89.50 0.00 0.01 2.50 3.50 0.00 0.03
Section 4: FIRST AID MEASURES
Inhalation:
Remove to fresh air. Seek medical attention.
Ingestion:
Not given.
CAS#
1344281 7789755 15096523 7439896 7789244 7440213
Skin Contact:
Safety Data Sheet (SDS)
Print Date:
Issue Date:
CENTURY ALUMINUM OF KENTUCKY LLC
P.O. BOX 500 HAWESVILLE, KY 42348
CRUSHED BATH
Wash skin with soap and water.
5/10/2015
1/5/2011
Eye Contact: Flush eyes with water. Seek medical attention.
Section 5: FIRE FIGHTING MEASURES
Flash Point:
N/A
Ignition Temperature:
N/A
Flammable Range:
Lower Limit: N/G
%
Upper Limit: N/G
%
Extinguish Media:
N/A
Special Precautions:
Reactions can release acetylene gas.
Section 6: ACCIDENTAL RELEASE MEASURES
Spill: Any material should be recovered. Waste Disposal Method: Recycle SECTION VIII - SPECIAL PROTECTION INFORMATION Respiratory Protection (Specify Type): See Note. NIOSH/MSHA approved respiratory protection as required. Ventilation: See Note. Local exhaust recommended if PEL s are exceeded. Protective gloves: Yes Eye Protection: Yes
Section 7: HANDLING AND STORAGE
No special handling required as shipped; however, if dust is generated during handeling, hazardous
Section 8: EXPOSURE CONTROL AND PERSONAL PROTECTION
Personal Protective Equipment: Respiratory Requirements: NIOSH/MSHA Approved
Gloves Requirements:
Required-Type Not Specified
Eye Protection:
Required-Type Not Specified
Ventilation Requirements: Local exhaust recommended if PEL s are
Other Requirements:
None
Section 9: PHYSICAL AND CHEMICAL PROPERTIES
Vapor Density: Specific Gravity: Highest Vapor Pressure:
N/G 1.6 N/G
Air:
Lighter
Same
Heavier
Not Given
N/A
Water: Lighter
Same
Heavier
Not Given
N/A
Boiling Point:
N/A
Melting Point:
N/A
Appearance:
Grayish-White Solid
Odor: Slight Musty Odor
Water Soluble/Miscible?:
Yes
No
Slightly
Not Given
PH:
Section 10 STABILITY AND REACTIVITY
Incompatible Materials: Reaction with acids results in release of HF. Bath, water, and aluminum carbide will form acetylene gas.
Safety Data Sheet (SDS)
Print Date:
Issue Date:
CENTURY ALUMINUM OF KENTUCKY LLC
P.O. BOX 500 HAWESVILLE, KY 42348
CRUSHED BATH
5/10/2015
1/5/2011
Section 11 TOXICOLOGICAL INFORMATION
Route of Entry: Ingestion
Skin/Eye Contact
Skin Absorption
Inhalation
N/A
Section 12 ECOLOGICAL INFORMATION (non-mandatory)
N/A
Section 13 DISPOSAL CONSIDERATION (non-mandatory)
Recycle if possible. Dispose of waste in accordance with federal, state, or local regulations.
Section 14 TRANSPORT INFORMATION (non-mandatory)
TDGR: Not regulated CFR 49: Not regulated. IMO: Not regulated. ICAO: Not regulated. IATA: Not regulated.
Section 15 REGULATORY INFORMATION (non-mandatory)
Section 16 OTHER INFORMATION
EPA-RCRA CEI Report June 26, 2024
Page 50 of 76
Century Aluminum of South Carolina SCD097366165
Attachment D Waste Bath Solid Waste Determination
EPA-RCRA CEI Report June 26, 2024
Page 51 of 76
Century Aluminum of South Carolina SCD097366165
Century Aluminum (EPA ID #: SCD097366165)
Solid Waste Determination as required by 40CFR 262.11 & 262.40(c)
Waste Common Name
Waste Bath
Description
Cryolite Bath on floor of building 139
Generating Process
Bath that has spilled on the ground in building 139 is periodically cleaned up
Physical Form
White Solid
Regulatory Status
EPA Hazardous
State Hazardous
Not regulated as hazardous waste
EPA/state Hazardous Waste Number(s)
N/A
Listings
non-specific source
F
specific source
K
discarded commercial chemical U
P
Not a listed hazardous waste.
Characteristics
determined by
waste code
testing
knowledge
ignitability
D001
corrosivity
D002
reactivity
D003
TC toxic
D
Land Disposal Restrictions (LDR's)
N/A
Subpart CC Determination/Compliance
Not applicable
Exempt: VO < 500ppm by wt.
Exempt: managed in containers < 0.1 m3
Onsite Management
Satellite accumulation < 90-day accumulation
Pipeline to treatment/recycling Other
When too much spilled bath has accumulated on the floor of building 139 the waste bath is placed into 20 yard containers and
hauled to the landfill by Carolina Waste
Final Disposition
Offsite TSDF/recycle POTW Berkeley County Landfill, Special Waste ID Number SW04
Shipping Information
USDOT Shipping Name: Hazard Class: UN/NA Number: Packing Group: RQ: Other - Technical Name: Other - Marine Pollutant: Emergency Response Guide (ERG) Number: Container Designation: Label(s) Required: Mark(s) Required:
Overall Comments
Onsite WWTU / ENU
Non-Regulated Material NA NA NA NA NA NA NA 20 yard roll off container N/A NA
Onsite recycling
Print date: 7/18/2024 Revision: 2 Revision Date: 2013 October 3
Page 52 of 76
Page1 Revision Author: ___Lauren Cox__
Attachment E Safety Data Sheet for Cryolite
EPA-RCRA CEI Report June 26, 2024
Page 53 of 76
Century Aluminum of South Carolina SCD097366165
ChemicalBook
Chemical Safety Data Sheet MSDS / SDS
cryolite
Revision Date:2024-06-22 Revision Number:1
SECTION 1: Identification of the substance/mixture and of the company/undertaking
Product identifier
Product name CBnumber CAS EINECS Number Synonyms
: cryolite : CB1300372 : 15096-52-3 : 239-148-8 : CRYOLITE,synthetic cryolite
Relevant identified uses of the substance or mixture and uses advised against
Relevant identified uses Uses advised against
: For R&D use only. Not for medicinal, household or other use. : none
Company Identification
Company Address Telephone
: Chemicalbook : Building 1, Huihuang International, Shangdi 10th Street, Haidian District, Beijing : 400-158-6606
SECTION 2: Hazards identification
GHS Label elements, including precautionary statements
Symbol(GHS)
Signal word
Danger
Precautionary statements
P260 Do not breathe dust/fume/gas/mist/vapours/spray.
P264 Wash hands thoroughly after handling.
P264 Wash skin thouroughly after handling.
P270 Do not eat, drink or smoke when using this product.
P304+P340 IF INHALED: Remove victim to fresh air and Keep at rest in a position comfortable for breathing.
Hazard statements
H332 Harmful if inhaled
H372 Causes damage to organs through prolonged or repeated exposure
H411 Toxic to aquatic life with long lasting effects
EPA-RCRA CEI Report June 26, 2024
Chemical Book
Page 54 of 76
Century Aluminum of
1
South Carolina
SCD097366165
SECTION 3: Composition/information on ingredients
Substance
Product name Synonyms CAS EC number MF MW
: cryolite : CRYOLITE,synthetic cryolite : 15096-52-3 : 239-148-8 : AlF6Na3 : 209.94
SECTION 4: First aid measures
Description of first aid measures
General advice Consult a physician. Show this safety data sheet to the doctor in attendance. If inhaled If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician. In case of skin contact Wash off with soap and plenty of water. Take victim immediately to hospital. Consult a physician. In case of eye contact Flush eyes with water as a precaution. If swallowed Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.
Most important symptoms and effects, both acute and delayed
The most important known symptoms and effects are described in the labelling (see section 2.2) and/or in section 11
Indication of any immediate medical attention and special treatment needed
No data available
SECTION 5: Firefighting measures
Extinguishing media
Suitable extinguishing media Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
Special hazards arising from the substance or mixture
Hydrogen fluoride, Sodium oxides, Aluminum oxide
Advice for firefighters
Wear self-contained breathing apparatus for firefighting if necessary.
EPA-RCRA CEI Report June 26, 2024
Chemical Book
Page 55 of 76
Century Aluminum of 2 South Carolina SCD097366165
Further information
No data available
SECTION 6: Accidental release measures
Personal precautions, protective equipment and emergency procedures
Use personal protective equipment. Avoid dust formation. Avoid breathing vapours, mist or gas. Ensure adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust. For personal protection see section 8.
Environmental precautions
Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the environment must be avoided.
Methods and materials for containment and cleaning up
Pick up and arrange disposal without creating dust. Sweep up and shovel. Keep in suitable, closed containers for disposal.
Reference to other sections
For disposal see section 13.
SECTION 7: Handling and storage
Precautions for safe handling
Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Provide appropriate exhaust ventilation at places where dust is formed. For precautions see section 2.2.
Conditions for safe storage, including any incompatibilities
Keep container tightly closed in a dry and well-ventilated place. Store in cool place.
Specific end use(s)
Apart from the uses mentioned in section 1.2 no other specific uses are stipulated
SECTION 8: Exposure controls/personal protection
control parameter
Hazard composition and occupational exposure limits Does not contain substances with occupational exposure limits.
Exposure controls
Appropriate engineering controls
Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.
Personal protective equipment
EPA-RCRA CEI Report June 26, 2024
Chemical Book
Page 56 of 76
Century Aluminum of
3
South Carolina
SCD097366165
Personal protective equipment Eye/face protection Face shield and safety glasses Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Skin protection Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it. Body Protection Complete suit protecting against chemicals, The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace. Respiratory protection Where risk assessment shows air-purifying respirators are appropriate use a full- face particle respirator type N99 (US) or type P2 (EN 143) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU). Control of environmental exposure Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the environment must be avoided.
SECTION 9: Physical and chemical properties
Information on basic physicochemical properties
Appearance Odour Odour Threshold pH Melting point/freezing point Initial boiling point and boiling range Flash point Evaporation rate Flammability (solid, gas) Upper/lower flammability or explosive limits Vapour pressure Vapour density Relative density Water solubility Partition coefficient: n-octanol/water Autoignition temperature Decomposition temperature Viscosity Explosive properties
EPA-RCRA CEI Report June 26, 2024
beige solid No data available No data available No data available 1012 decomp Not applicable No data available No data available No data available
No data available
No data available
No data available
No data available
No data available
No data available
No data available
No data available
No data available
Chemical Book
Page 57 of 76
Century Aluminum of South Carolina 4 SCD097366165
Oxidizing properties
Other safety information
No data available
No data available
SECTION 10: Stability and reactivity
Reactivity
No data available
Chemical stability
Stable under recommended storage conditions.
Possibility of hazardous reactions
No data available
Conditions to avoid
No data available
Incompatible materials
Strong oxidizing agentsStrong bases
Hazardous decomposition products
Hazardous decomposition products formed under fire conditions. - Hydrogen fluoride, Sodium oxides, Aluminum oxide Other decomposition products - No data available In the event of fire: see section 5
SECTION 11: Toxicological information
Information on toxicological effects
Acute toxicity LD50 Oral - Rat - > 5.000 mg/kg Remarks: Gastrointestinal:Changes in structure or function of salivary glands. Skin and Appendages: Other: Hair. Skin corrosion/irritation No data available Serious eye damage/eye irritation No data available Respiratory or skin sensitisation No data available Germ cell mutagenicity No data available Carcinogenicity IARC: No component of this product present at levels greater than or equal to 0.1% is identified as probable, possible or confirmed human
EPA-RCRA CEI Report June 26, 2024
Chemical Book
Page 58 of 76
Century Aluminum of
5
South Carolina
SCD097366165
carcinogen by IARC. Reproductive toxicity No data available Specific target organ toxicity - single exposure No data available Specific target organ toxicity - repeated exposure Causes damage to organs through prolonged or repeated exposure. Aspiration hazard No data available Additional Information RTECS: Not available
SECTION 12: Ecological information
Toxicity
Toxicity to fish LC50 - Oncorhynchus mykiss (rainbow trout) - 42,5 mg/l - 96,0 h Toxicity to daphnia and other aquatic invertebrates EC50 - Daphnia magna (Water flea) - > 100 mg/l - 48 h
Persistence and degradability
No data available
Bioaccumulative potential
No data available
Mobility in soil
No data available
Results of PBT and vPvB assessment
This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.
Other adverse effects
Toxic to aquatic life with long lasting effects.
SECTION 13: Disposal considerations
Waste treatment methods
Product
Offer surplus and non-recyclable solutions to a licensed disposal company. Dissolve or mix the material with a combustible solvent and burn in
a chemical incinerator equipped with an afterburner and scrubber. Waste material must be disposed of in accordance with the Directive on
EPA-RCRA CEI Report
Chemical Book
Century Aluminum of
6
June 26, 2024
Page 59 of 76
South Carolina SCD097366165
waste 2008/98/EC as well as other national and local regulations. Leave chemicals in original containers. No mixing with other waste. Handle uncleaned containers like the product itself. Incompatibilities Incompatible with strong acids such as sulfuric, strong oxidizers, hydrogen fluoride. Waste Disposal In accordance with 40CFR 165 recommendations for the disposal of pesticides and pesticide containers. Must be disposed properly by following package label directions or by contacting your local or federal environmental control agency, or by contacting your regional EPA office.
Contaminated packaging
Dispose of as unused product.
SECTION 14: Transport information
UN number
ADR/RID: 3077 IMDG: 3077 IATA: 3077
UN proper shipping name
ADR/RID: ENVIRONMENTALLY HAZARDOUS SUBSTANCE, SOLID, N.O.S. (Cryolite) IMDG: ENVIRONMENTALLY HAZARDOUS SUBSTANCE, SOLID, N.O.S. (Cryolite) IATA: Environmentally hazardous substance, solid, n.o.s. (Cryolite)
Transport hazard class(es)
ADR/RID: 9 IMDG: 9 IATA: 9
Packaging group
ADR/RID: III IMDG: III IATA: III
Environmental hazards
ADR/RID: yes IMDG Marine pollutant: yes IATA: yes
Special precautions for user
Further information
EHS-Mark required (ADR 2.2.9.1.10, IMDG code 2.10.3) for single packagings and combination packagings containing inner packagings with Dangerous Goods > 5L for liquids or > 5kg for solids.
SECTION 15: Regulatory information
Safety, health and environmental regulations/legislation specific for the substance or mixture
Regulations on the Safety Management of Hazardous Chemicals
China Catalog of Hazardous chemicals 2015:Not Listed. website: https://www.mem.gov.cn/
Measures for Environmental Management of New Chemical Substances
EPA-RCRA CEI Report June 26, 2024
Chemical Book
Page 60 of 76
Century Aluminum of
7
South Carolina
SCD097366165
Chinese Chemical Inventory of Existing Chemical Substances (China IECSC):Listed. website: https://www.mee.gov.cn/ EC Inventory:Listed. European Inventory of Existing Commercial Chemical Substances (EINECS):Listed. website: https://echa.europa.eu/ Korea Existing Chemicals List (KECL):Listed. website: http://ncis.nier.go.kr New Zealand Inventory of Chemicals (NZIoC):Listed. website: https://www.epa.govt.nz/ Philippines Inventory of Chemicals and Chemical Substances (PICCS):Listed. website: https://emb.gov.ph/ United States Toxic Substances Control Act (TSCA) Inventory:Listed. website: https://www.epa.gov/ Vietnam National Chemical Inventory:Listed. website: https://chemicaldata.gov.vn/
SECTION 16: Other information
Abbreviations and acronyms
ADR: European Agreement concerning the International Carriage of Dangerous Goods by Road CAS: Chemical Abstracts Service EC50: Effective Concentration 50% IATA: International Air Transportation Association IMDG: International Maritime Dangerous Goods LC50: Lethal Concentration 50% LD50: Lethal Dose 50% RID: Regulation concerning the International Carriage of Dangerous Goods by Rail STEL: Short term exposure limit TWA: Time Weighted Average
References
1CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple 2ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp 3ECHA - European Chemicals Agency, website: https://echa.europa.eu/ 4eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en 5ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg 6Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp 7HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm 8IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/ 9IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home 10Sigma-Aldrich, website: https://www.sigmaaldrich.com/
Disclaimer: The information in this MSDS is only applicable to the specified product, unless otherwise specified, it is not applicable to the mixture of this product and other substances. This MSDS only provides information on the safety of the product for those who have received the appropriate professional training for the user of the product. Users of this MSDS must make independent judgments on the applicability of this SDS. The authors of this MSDS will not be held responsible for any harm caused by the use of this MSDS.
EPA-RCRA CEI Report June 26, 2024
Page 61 of 76
Chemical Book
Century Aluminum of
South Carolina
SCD097366165
8
Attachment F Weekly inspection sheets (for three months) for the Building 138 CAA
EPA-RCRA CEI Report June 26, 2024
Page 62 of 76
Century Aluminum of South Carolina SCD097366165
SPENT POTLINING CONTAINMENT BUILDING INSPECTION (BLDG 138)
HAZARDOUS/RESTRICTED WASTE MANAGEMENT
( Date & Time Inspected:
Day of Week:
A. GENERATION/SHIPPING
1 . How many pots were dug this week? 2. How many container loads of SPL-Carbon were shipped? B. BUILDING 138HAZARDOUS WASTE 90DAY STORAGE AREA 1. Any SPL Carbon containers in storage? Ifyes SPL Carbon Quantity cy
*Remember to document container ID during last quarterly inspection
Pots
7Containers
Yes No NIA
(XI D D
2. Shipping containers in good condition, free from leaks, closed & labeled?
[j D
3. Only hazardous waste containers in 90 day area?
l2f- D
4. Do all containers have start dates? Oldest shipping container Date: ___
5 Containers locatedjn_designated-S<tday--area-t--. -------------1--____
6. Proper isle space between full containers?
7. All containers stored <90 days? Date will reach 90 days: C. BUILDING 138 HOUSEKEEPING
D
D D
,0______ 0 D
1. After building cleanouts is the dig area clean of SPL material? 2. SPL debris & vacuum containers labeled, closed & in good condition? 3. Bunker curtain closed & in good condition? SPL Insulation uanti
l1J D
DD __o____
er l!!\;ttgo!t:i::;;p::;d with pofnurriberaridpu11 date?
B '-1-J. Mobile equipment/trailers/containers clean of SPL residue?
Area outside of containment free of material tracking?
Last room cleanout date? NJr.
.
( DC discharge hopper closed, labeled & free of leaks? Hopper Date? 10. DC free ofvisible leaks and no material spillage on the pad under the DC?
D. BUILDING 138 STRUCTURAL INTEGRITY
1. Floor in dig area free of cracks & gaps that could lead to a release?
2. Building roof & walls free of damage?
_
E. CAST HOUSE WAZAJIDOUS WASTE 90 DAY STORAGE AR, EA
1. Any hazardous waste containers in storage?
*Remember to document container ID during last quarterly inspection
0
0
D D
1251 D D
D D
D D D (211 D
Q 0
2. Only hazardous waste containers in 90 day area? 3. All containers stored < 90 days? 4. Shipping containers in good condition, free from leaks, closed & labeled? . 5. Proper isle space bftween full containers?
I F. WASTE FLUID AREA; 90 DAYSTORAGE AREA
1. Any hazardous waste containers in storage? 2 All containers tqred < 90 days? 3. Containers in good condition, no leaks, clean, and properly closed? 4. Coptainers properly labeled and dated? 5. Secondary containment free from damage? 6. Proper aisle spacing around containers? 7. Emergency communications system available/operable? 8. Firefighting equipment available/operable? G. PCB BALLASTS/CAPACITORS
,.,,
1. Any PCB waste containers in storage?
GX' 2. Containers are in good condition, non-leaking, contained, labeled and dated?
\ i ( 3. All containers stored <270 days? Date will reach 270 days:---H. BAKE STACK PLENUM AREA 90 DAY STORAGE AREA
Yes No NIAJ
FCD-0236 - Rev 22
EPA-RCRA CEI Report
June 26, 2024
Page 63 of 76
Century Aluminum of South Carolina SCD097366165
1. Any hazar ous w ste containers in storage?
2. Container in go d condition, no leaks, clean, and properly closed?
3. Container pr pe ly labeled and dated?
4. All contai ers sto ed <90 days?
(
5. Proper aisl sac g around containers?
6. E\1}ergenc communications system available/operable?
7. Firefightin equipment available/operable?
Weather Condition'.@9'r Raining)
#
Deficiency Comments
Corrective Action
1. 2.
3. 4. 5. '6.
i
Completion Date
Rating: - (s'
Inspector's Signatre: .
U = Unsatisfactory
*Iflast Inspection ofthe quarter (Last inspection in March, June, September, and December) Mark Container ID
Numbers in the Table Below
138 SPL Container IDs
Cast House SPL Container IDs
STOP ifhazardous waste containers are not completely closed STOP ifcrack, leaks or holes are identified in the containment building STOP ifthere is not enough isle space between containers
STOP ifhazardous waste containers are not properlv labeled STOP ifhazardous waste containers are not stored in the correct location STOP ifSPL found outside ofthe containment building or outside ofshipment containers
STOP iftruck traffic in cast house area is congested
STOP ifrelining traffic in 138 area is congested
STOP ifwaste fluid area traffic is congested from traffic to the waste fluid area or to building 139 STOP ifhazardous waste not properly contained. STOP ifhazardous waste containers are stored >90 days or if PCB containers stored >270 days STOP ifSPL found leaking from the 138 dust collector or on the pad under the 138 dust collector
FCD-0236 - Rev 22
EPA-RCRA CEI Report
June 26, 2024
Page 64 of 76
Century Aluminum of South Carolina SCD097366165
SPENT POTLINING CONTAINMENT BUILDING INSPECTION (BLDG 138)
HAZARDOUS/RESTRICTED WASTE MANAGEMENT
Date & Time Inspected:
Day of Week:
Period:
A. GENERATION/SHIPPING
1. How many pots were dug this week?
()Pots
c? 2. How many container loads of SPL-Carbon were shipped?
Containers
B. BUILDING 138 HAZARDOUS WASTE 90 DAY STORAGE AREA 1. Any SPL Carbon containers in storage? If yes SPL Carbon Quantity __ cy *Remember to document container ID during last quarterly inspection 2. Shipping containers in good condition, free from leaks, closed & labeled? 3. Only hazardous waste containers in 90 day area? 4. Do all containers have start dates? Oldest shipping container Date:
___5.- . ContainersJocated-in-designated-90-day-arna
Yes No NIA
[gJ iZ] 1K] --B-
6. Proper isle space between full containers?
t 7. All containers stored <90 days? Date will reach 90 days:
C. BUILDING 138 HOUSEKEEPING
1. After building cleanouts is the dig area clean of SPL material?
2. SPL debris & vacuum containers labeled, closed & in good condition?
@.
3. Bunker curtain closed & in good condition? SPL Insulation guantity
CX---
4. Pullei.rpots waiting to-oe dug-are marl<ed with pot number and pull date?
5. No visible SPL on outside storage pad?
i 6. Mobile equipment/trailers/containers clean of SPL residue?
7. Area outside of containment fi*e of material tracking?
8. Last room cleanout date?
(
9. DC discharge hopper closed, labeled & free of leaks? Hopper Date? (jf--J 0
(
10. DC free of visible leaks and no material spillage on the pad under the DC?
[29
D. BUILDING 138 STRUCTURAL INTEGRITY
1. Floor in dig area free of cracks & gaps that could lead to a release?
[15
2. Building roof & walls free of damage?
E. CAST HOUSE HAZARDOUS WASTE 90 DAY STORAGE AREA
1. Any hazardous waste containers in storage?
[(]
*Remember to document container ID during last quarterly inspection
2. Only hazardous waste containers in 90 day area? 3. All containers stored < 90 days? 4. Shipping containers in good condition, free from leaks, closed & labeled? 5. Proper isle space between full containers? F. WASTE FLUID AREA 90 DAY STORAGE AREA 1. Any hazardous waste containers in storage? 2 All containers stored < 90 days? 3. Containers in good condition, no leaks, clean, and properly closed? 4. Containers properly labeled and dated? 5. Secondary containment free from damage? 6. Proper aisle spacing around containers? 7. Emergency communications system available/operable? 8. Firefighting equipment available/operable? G. PCB BALLASTS/CAPACITORS 1. Any PCB waste containers in storage? 2. Containers are in good condition, non-leaking, contained, labeled and dated?
01 [XI [j [j]
/
3. All containers stored <270 days? Date will reach 270 days:
H. BAKE STACK PLENUM AREA 90 DAY STORAGE AREA
Yes No NIA
FCD-0236 - Rev 22
EPA-RCRA CEI Report
June 26, 2024
Page 65 of 76
Century Aluminum of South Carolina SCD097366165
l. Any hazardous waste containers in storage? 2. Containers in good condition, no leaks, clean, and properly closed? 3. Containers properly labeled and dated? 4. All containers stored <90 days? 5. Proper aisle spacing around containers? 6. Emergency communications system available/operable? 7. Firefighting equipment available/operable?
Weather Condition: @or Raining)
#
Deficiency Comments
Corrective Action
1. 2.
3. 4. 5. 6.
Completion Date
Rating:
sfacto
U = Unsatisfactory
..Inspector's Si:;:::;;;;.=;;;;;;--:".-'.-:""================-======-=-=-=-=-===-=
*If last Inspection of the quarter (Last inspection in March, June, September, and December) Mark Container ID
Numbers in the Table Below
(
138 SPL Container IDs
Cast House SPL Container IDs
STOP ifhazardous waste containers are not completely closed STOP ifcrack, leaks or holes are identified in the containment building STOP ifthere is not enough isle space between containers
STOP ifhazardous waste containers are not properly labeled STOP ifhazardous waste containers are not stored in the correct location STOP ifSPL found outside ofthe containment building or outside ofshipment containers
STOP iftruck traffic in cast house area is congested
STOP ifrelining traffic in 138 area is congested
STOP ifwaste fluid area traffic is congested from traffic to the waste fluid area or to building 139 STOP if hazardous waste not properly contained. STOP if hazardous waste containers are stored >90 days or if PCB containers stored >270 days STOP ifSPL found leaking from the 138 dust collector or on the pad under the 138 dust collector
EPA-RCRA CEI Report
June 26, 2024
FCD-0236 - Rev 22
Page 66 of 76
Century Aluminum of South Carolina SCD097366165
SPENT POTLINING CONTAINMENT BUILDING INSPECTION (BLDG 138)
HAZARDOUS/RESTRICTED WASTE MANAGEMENT
(
Date & Time Inspected:
Day of Week:
Period:
A. GENERATION/SHIPPING
1. How many pots were dug this week?
2. How many container loads of SPL-Carbon were shipped?
B. BUILDING 138 HAZARDOUS WASTE 90 DAY STORAGE AREA
1. Any SPL Carbon containers in storage? If yes SPL Carbon Quantity cy
*Remember to document container ID during last quarterly inspection
2. Shipping containers in good condition, free from leaks, closed & labeled?
3. Only hazardous waste containers in 90 day area?
4. Do all containers have start dates? Oldest shipping container Date: oI"'\-}c','&\,:)>
_____5. _ Containers located in-designated 90-day-ar.ea1---- - - - -- - - - -- -
5.... 6. Proper isle space between full containers?
7. All containers stored <90 days? Date will reach 90 days: C. BUILDING 138 HOUSEKEEPING
(7-)
1. After building cleanouts is the dig area clean of SPL material?
2. SPL debris & vacuum containers labeled, closed & in good condition?
---3. -- Bunker curtain closed & in good condition? SPL Insulation quantity
cy
4. Pulled pots waiting to be dug are marked with pot number and pull date?
5. No visible SPL on outside storage pad?
6. Mobile equipment/trailers/containers clean of SPL residue?
7. Area outside of containmenfj;ee of material tracking?
8. Last room cleanout date? fYA-
9. DC discharge hopper closed, labeled & free of leaks? Hopper Date? (-1
10. DC free of visible leaks and no material spillage on the pad under the DC?
D. BUILDING 138 STRUCTURAL INTEGRITY
1. Floor in dig area free of cracks & gaps that could lead to a release?
2. Building roof & walls free of damage?
E. CAST HOUSE HAZARDOUS WASTE 90 DAY STORAGE AREA
1. Any hazardous waste containers in storage?
*Remember to document container ID during last quarterly inspection
2. Only hazardous waste containers in 90 day area?
3. All containers stored < 90 days?
4. Shipping containers in good condition, free from leaks, closed & labeled?
5. Proper isle space between full containers?
F. WASTE FLUID AREA 90 DAY STORAGE AREA
1. Any hazardous waste containers in storage?
2 All containers stored < 90 days?
3. Containers in good condition, no leaks, clean, and properly closed?
4. Containers properly labeled and dated?
5. Secondary containment free from damage?
6. Proper aisle spacing around containers?
7. Emergency communications system available/operable?
8. Firefighting equipment available/operable?
G. PCB BALLASTS/CAPACITORS
1. Any PCB waste containers in storage?
2. Containers are in good condition, non-leaking, contained, labeled and dated?
3. All containers stored <270 days? Date will reach 270 days:___
H. BAKE STACK PLENUM AREA 90 DAY STORAGE AREA
t2 Pots
0 ntainers
Yes No NIA
I
--- ---- El
CJ_C]
I
DQ
i
I
Yes No NIA
FCD-0236 - Rev 22 EPA-RCRA CEI Report
Page 67 of 76
Century Aluminum of
June 26, 2024
South Carolina
SCD097366165
1. Any hazardous waste containers in storage? 2. Containers in good condition, no leaks, clean, and properly closed? 3. Containers properly labeled and dated? 4. All containers stored <90 days? 5. Proper aisle spacing around containers? 6. Emergency communications system available/operable? 7. Firefighting equipment available/operable?
Weather Condition: aining)
#
Deficiency Comments
Corrective Action
1. 2.
3. 4. 5. 6.
Rating:
isfacto
- ctor's Signatu;#
U = Unsatisfactory
Completion Date
*If last Inspection of the quarter (Last inspection in March, June, September, and December) Mark Container ID
Numbers in the Table Below
138 SPL Container IDs
Cast House SPL Container IDs
'
STOP ifhazardous waste containers are not completely closed STOP ifcrack, leaks or holes are identified in the containment building STOP ifthere is not enough isle space between containers
STOP ifhazardous waste containers are not properly labeled STOP ifhazardous waste containers are not stored in the correct location STOP ifSPL found outside ofthe containment building or outside ofshipment containers
STOP iftruck traffic in cast house area is congested
STOP ifrelining traffic in 138 area is congested
STOP ifwaste fluid area traffic is congested from traffic to the waste fluid area or to building 139 STOP ifhazardous waste not properly contained. STOP ifhazardous waste containers are stored >90 days or if PCB containers stored >270 days STOP ifSPL found leaking from the 138 dust collector or on the pad under the 138 dust collector
EPA-RCRA CEI Report June 26, 2024
FCD-0236 - Rev 22
Page 68 of 76
Century Aluminum of South Carolina SCD097366165
SPENT POTLINING CONTAINMENT BUILDING INSPECTION (BLDG 138)
HAZARDOUS/RESTRICTED WASTE MANAGEMENT
Date & Time Inspected:
Day ofWeek:
A. GENERATION/SHIPPING 1. How many pots were dug this week? 2. How many container loads ofSPL-Carbon were shipped?
I Pots II Containers
B. BUILDING 138 HAZARDOUS WASTE 90 DAY STORAGE AREA
No NIA
1. Any SPL Carbon containers in storage? Ifyes SPL Carbon Quantity _I__/ cy y0
*Remember to document container ID during last quarterly inspection
2. Shipping containers in good condition, free from leaks, closed & labeled?
3. Only hazardous waste containers in 90 day area?
4. Do all containers have start dates? Oldest shipping container Date: 2./, 5/. -f I
i 5. Containers located in designated 90 day area?
I /J 6. Proper isle space between full containers?
7. All containers stored <90 days? Date will reach 90 days: 5 5/z"!f
C. BUILDING 138 HOUSEKEEPING
1. After building cleanouts is the dig area clean of SPL material?
g'
2. SPL debris & vacuum containers labeled, closed & in good condition?
i 3. Bunker curtain closed & in good condition? SPL Insulation quantity __ cy
4. Pulled pots waiting to be dug are mark.ed with pot number arid pull date? 5. No visible SPL on outside storage pad? 6. Mobile equipment/trailers/containers clean ofSPL residue? 0 7. Area outside ofcontainment free ofmaterial tracking? 8. Last room cleanout date? 9. DC discharge hopper closed, labeled & free ofleaks? Hopper Date?
i 10. DC free ofvisible leaks and no material spillage on the pad under the DC?
D. BUILDING 138 STRUCTURAL INTEGRITY
1. Floor in dig area free ofcracks & gaps that could lead to a release? 2. Building roof & walls free ofdamage? E. CAST HOUSE HAZARDOUS WASTE 90 DAY STORAGE AREA 1. Any hazardous waste containers in storage?
*Remember to document container ID during last quarterly inspection
2. Only hazardous waste containers in 90 day area? 3. All containers stored < 90 days? 4. Shipping containers in good condition, free from leaks, closed & labeled? 5. Proper isle space between full containers?
J F. WASTE FLUID AREA 90 DAY STORAGE AREA 1. Any hazardous waste containers in storage? 2 All containers stored < 90 days? 3. Containers in good condition, no leaks, clean, and properly closed? 4. Containers properly labeled and dated? 5. Secondary containment free from damage? 6. Proper aisle spacing around containers? 7. Emergency communications system available/operable? 8. Firefighting equipment available/operable?
G. PCB BALLASTS/CAPACITORS
1. Any PCB waste containers in storage? 2. Containers are in good condition, non-leaking, contained, labeled and dated?
[0
(
3. All containers stored <270 days? Date will reach 270 days:
H. BAKE STACK PLENUM AREA 90 DAY STORAGE AREA
Yes No NIA
FCD-0236 - Rev 22
EPA-RCRA CEI Report June 26, 2024
Page 69 of 76
Century Aluminum of South Carolina SCD097366165
1. Any hazardous waste containers in storage? 2. Containers in good condition, no leaks, clean, and properly closed? 3. Containers properly labeled and dated? 4. All containers stored <90 days? 5. Proper aisle spacing around containers? 6. Emergency communications system available/operable? 7. Firefighting equipment available/operable?
Weather Condition ,s-ie,
#
Deficiency Comments
Corrective Action
1. 2.
3. 4. 5. 6.
Rating:
Inspector's Signatu __ _
Completion Date
*If last Inspection of the quarter (Last inspec on in March, June, September, and December) Mark Container ID
Numbers in the Table Below
138 SPL Container IDs
Cast House SPL Container IDs
STOP if hazardous waste containers are not completely closed STOP if crack, leaks or holes are identified in the containment building STOP if there is not enough isle space between containers
STOP if hazardous waste containers are not properly labeled STOP if hazardous waste containers are not stored in the correct location STOP if SPL found outside of the containment building or outside of shipment containers
STOP if truck traffic in cast house area is congested
STOP if relining traffic in 138 area is congested
STOP if waste fluid area traffic is congested from traffic to the waste fluid area or to building 139 STOP if hazardous waste not properly contained. STOP if hazardous waste containers are stored >90 days or if PCB containers stored >270 days STOP if SPL found leaking from the 138 dust collector or on the pad under the 138 dust collector
EPA-RCRA CEI Report June 26, 2024
FCD-0236 - Rev 22
Page 70 of 76
Century Aluminum of South Carolina SCD097366165
SPENT POTLINING CONTAINMENT BUILDING INSPECTION (BLDG 138)
HAZARDOUS/RESTRICTED WASTE MANAGEMENT
( Date & Time Inspected:
Day ofWeek:
A. GENERATION/SmPPING
1. How many pots were dug this week?
I Pots
2. How many container loads ofSPL-Carbon were shipped?
Containers
B. BUILDING 138 HAZARDOUS WASTE 90 DAY STORAGE AREA
No NIA
1. Any SPL Carbon containers in storage? Ifyes SPL Carbon Quantity _t_l_ cy y
*Remember to document container ID during last quarterly inspection
0' 2. Shipping containers in good condition, free from leaks, closed & labeled?
3. Only hazardous waste containers in 90 day area?
4. Do all containers have start dates? Oldest shipping container Date: 2./1'5/2.+
5. ContainersJocatedin_ designated. 90 day area?
i 6. Proper isle space between full containers?
7. All containers stored <90 days? Date will reach 90 days: 5/, (,/2 4
C. BUILDING 138 HOUSEKEEPING
1. After building cleanouts is the dig area clean ofSPL material?
2. SPL debris & vacuum containers labeled, closed & in good condition?
0"' 3. Bunker curtain closed & in good condition? SPL Insulation quantity __ cy
4. Pulled pots waiting to be dug are marked with pot number and pull date?
[f 5. No visible SPL on outside storage pad?
6. Mobile equipment/trailers/containers clean ofSPL residue?
7. Area outside ofcontainment free ofmaterial tracking?
8. Last room cleanout date?
i 9. DC discharge hopper closed, labeled & free ofleaks? Hopper Date?
(
10. DC free ofvisible leaks and no material spillage on the pad under the DC?
D. BUILDING 138 STRUCTURAL INTEGRITY
1. Floor in dig area free ofcracks & gaps that could lead to a release?
I 2. Building roof& walls free ofdamage?
E. CAST HOUSE HAZARDOUS WASTE 90 DAY STORAGE AREA
fl' 1. Any hazardous waste containers in storage?
*Remember to document container ID during last quarterly inspection
2. Only hazardous waste containers in 90 day area?
3. All containers stored < 90 days?
4. Shipping containers in good condition, free from leaks, closed & labeled? 5. Proper isle space between full containers?
0
F. WASTE FLUID AREA 90 DAY STORAGE AREA
1. Any hazardous waste containers in storage?
2 All containers stored < 90 days?
l 3. Containers in good condition, no leaks, clean, and properly closed?
4. Containers properly labeled and dated?
5. Secondary containment free from damage?
I 6. Proper aisle spacing around containers?
7. Emergency communications system available/operable?
[f 8. Firefighting equipment available/operable?
G. PCB BALLASTS/CAPACITORS
[i' 1. Any PCB waste containers in storage? 2. Containers are in good condition, non-leaking, contained, labeled and dated?
( 3. All containers stored <270 days? Date will reach 270 days:
H. BAKE STACK PLENUM AREA 90 DAY STORAGE AREA
Yes No NIA
FCD-0236 - Rev 22
EPA-RCRA CEI Report
Page 71 of 76
Century Aluminum of
June 26, 2024
South Carolina
SCD097366165
1. Any hazardous waste containers in storage?
2. Containers in good condition, no leaks, clean, and properly closed?
3. Containers properly labeled and dated?
4. All containers stored <90 days?
5. Proper aisle spacing around containers?
6. Emergency communications system available/operable?
er 7. Firefighting equipment available/operable?
Weather Condition:
Raining)
#
Deficiency Comments
Corrective Action
1. 2.
3. 4. 5. 6.
Rating:
Inspector's Signatui'tro--
= Unsatisfactory
i @'
Completion Date
*If last Inspection of the quarter (Last inspection in March, June, September, and December) Mark Container ID
Numbers in the Table Below
138 SPL Container IDs
Cast House SPL Container IDs
STOP ifhazardous waste containers are not completely closed STOP ifcrack, leaks or holes are identified in the containment building STOP ifthere is not enough isle space between containers
STOP ifhazardous waste containers are not properly labeled STOP ifhazardous waste containers are not stored in the correct location STOP ifSPL found outside ofthe containment building or outside ofshipment containers
STOP iftruck traffic in cast house area is congested
STOP ifrelining traffic in 138 area is congested
STOP ifwaste fluid area traffic is congested from traffic to the waste fluid area or to building 139 STOP ifhazardous waste not properly contained. STOP ifhazardous waste containers are stored >90 days or if PCB containers stored >270 days STOP ifSPL found leaking from the 138 dust collector or on the pad under the 138 dust collector
EPA-RCRA CEI Report June 26, 2024
FCD-0236 - Rev 22
Page 72 of 76
Century Aluminum of South Carolina SCD097366165
SPENT POTLINING CONTAINMENT BUILDING INSPECTION
(BLDG 138) HAZARDOUS/RESTRICTED WASTE MANAGEMENT
( Date & Time Inspected:
1 Day of Week:
3/20/2024
WED.
A. GENERATION/SHIPPING
1. How many pots were dug this week?
Pots
2. How many container loads of SPL-Carbon were shipped?
O Containers
B. BUILDING138HAZARDOUSWASTE90DAYSTORAGEAREA
Y No NIA
1. Any SPL Carbon containers in storage? If yes SPL Carbon Quantity _I _i _ cy lY'.'.] D D
*Remember to document container ID during last quarterly inspection
!: g: I 8 2. Shipping containers in good condition, free from leaks, closed & labeled?
1
n
if P.t D
1::;;:;:::::1:::; 6d!:f's::ing container Date: JrfS--JO).'
: ;;:;:!;::::!!!";fa?
a- B
7. All containers stored <90 days? Date will reach 90 days: 5-JS-)Y
l.:0 D D
C. BUILDING 138 HOUSEKEEPING
1. After building cleanouts is the dig area clean of SPL material? 2. SPL debris & vacuum containers labeled, closed & in good condition?
;:- [;l;if;:f!i?r;;1:i:p;l0a1;;uifd-ta-?e _:_ cy
Q,; D IY{ D D
JD [ 6. Mobile equipment/trailers/containers clean of SPL residue?
D
: t::; = !;;eJVA of material tracking?
r
e
8 / (
9. DC discharge hopper closed, labeled & free of leaks? Hopper Date? j.-JJ-J1 W l..Yl'
D
10. DC free of visible leaks and no material spillage on the pad under the DC?
l:0 D D
D. BUILDING 138 STRUCTURAL INTEGRITY 1. Floor in dig area free of cracks & gaps that could lead to a release?
_/
2. Building roof & walls free of damage?
M 0
E. CAST HOUSE HAZARDOUS WASTE 90 DAY STORAGE AREA
1. Any hazardous waste containers in storage?
b1
*Remember to document container ID during last quarterly inspection
2. Only hazardous waste containers in 90 day area?
3. All containers stored < 90 days?
4. Shipping containers in good condition, free from leaks, closed & labeled?
5. Proper isle space between full containers?
F. WASTE FLUID AREA 90 DAY STORAGE AREA
1. Any hazardous waste containers in storage?
2 All containers stored < 90 days?
3. Containers in good condition, no leaks, clean, and properly closed?
4. Containers properly labeled and dated?
5. Secondary containment free from damage?
6. Proper aisle spacing around containers?
7. Emergency communications system available/operable?
8. Firefighting equipment available/operable?
G. PCB BALLASTS/CAPACITORS
1. Any PCB waste containers in storage?
2. Containers are in good condition, non-leaking, contained, labeled and dated?
3. All containers stored <270 days? Date will reach 270 days: ;YA-
H. BAKE STACK PLENUM AREA 90 DAY STORAGE AREA
Yes No NIA
FCD-0236 - Rev 22
EPA-RCRA CEI Report June 26, 2024
Page 73 of 76
Century Aluminum of South Carolina SCD097366165
1. Any hazardous waste containers in storage? 2. Containers in good condition, no leaks, clean, and properly closed? 3. Containers properly labeled and dated? 4. All containers stored <90 days? 5. Proper aisle spacing around containers? 6. Emergency communications system available/operable? 7. Firefighting equipment available/operable?
Weather Condition: Raining)
#
Deficiency Comments
Corrective Action
1. 2.
3. 4. 5. 6.
Rating: Inspector's Signature: -'I
U = Unsatisfactory
Completion Date
*If last Inspection of the quarter (Last insP,ection in March, June, September, and December) Mark Container ID
Numbers in the Table Below
138 SPL Container IDs
Cast House SPL Container IDs
STOP ifhazardous waste containers are not completely closed STOP ifcrack, leaks or holes are identified in the containment building STOP ifthere is not enough isle space between containers
STOP ifhazardous waste containers are not properly labeled STOP ifhazardous waste containers are not stored in the correct location STOP ifSPL found outside ofthe containment building or outside ofshipment containers
STOP iftruck traffic in cast house area is congested
STOP ifrelining traffic in 138 area is congested
STOP ifwaste fluid area traffic is congested from traffic to the waste fluid area or to building 139 STOP ifhazardous waste not properly contained. STOP ifhazardous waste containers are stored >90 days or if PCB containers stored >270 days STOP ifSPL found leaking from the 138 dust collector or on the pad under the 138 dust collector
EPA-RCRA CEI Report June 26, 2024
FCD-0236 - Rev 22
Page 74 of 76
Century Aluminum of South Carolina SCD097366165
SPENT POTLINING CONTAINMENT BUILDING INSPECTION (BLDG 138)
HAZARDOUS/RESTRICTED WASTE MANAGEMENT
( Date & Time Inspected:
Day ofWeek:
D3/z1/2024
Wt'D.
A. GENERATION/SHIPPING
1. How many pots were dug this week?
I Pots
2. How many container loads ofSPL-Carbon were shipped?
'). Containers
j B. BUILDING 138 HAZARDOUS WASTE 90 DAY STORAGE AREA
Yes No NIA
1. Any SPL Carbon containers in storage? Ifyes SPL Carbon Quantity __ cy
*Remember to document container ID during last quarterly inspection
2. Shipping containers in good condition, free from leaks, closed & labeled?
[ll
3. Only hazardous waste containers in 90 day area?
, . 1 . []
4. Do all containers have start dates? Oldest shipping container Date: l-)5-i1-lJ.1
S: Containerslocated indesignated 90 day area?
-Ill--- D -----
6. Proper isle space between full containers?
Ill:
7. All containers stored <90 days? Date will reach 90 days: S. - / -J,ti
C. BUILDING 138 HOUSEKEEPING
1. After building clean outs is the dig area clean ofSPL material?
2. SPL debris & vacuum containers labeled, closed & in good condition?
3. Bunker curtain closed & in good condition? SPL Insulation quantity __._ cy
--- " - - ." - -
;IZJ.
4. Pulled pots waiting to be dug are marked with pot number and pull date?
.[B. -
5. No visible SPL on outside storage pad?
[z5]
6. Mobile equipment/trailers/containers clean ofSPL residue?
[ZJ
ofmaterial tracking?
: t::r=e!;1;?v;r
(
9. DC discharge hopper closed, labeled & free ofleaks? Hopper Date? L-j-/ J-),1 [ll
10. DC free ofvisible leaks and no material spillage on the pad under the DC?
D. BUILDING 138 STRUCTURAL INTEGRITY
1. Floor in dig area free ofcracks & gaps that could lead to a release?
2. Building roof& walls free ofdamage?
E. CAST HOUSE HAZARDOUS WASTE 90 DAY STORAGE AREA 1. Any hazardous waste containers in storage?
0"
*Remember to document container ID during last quarterly inspection
2. Only hazardous waste containers in 90 day area?
3. All containers stored < 90 days?
4. Shipping containers in good condition, free from leaks, closed & labeled?
[lJ
5. Proper isle space between full containers?
[l]
F. WASTE FLUID AREA 90 DAY STORAGE AREA
1. Any hazardous waste containers in storage?
2 All containers stored < 90 days?
3. Containers in good condition, no leaks, clean, and properly closed?
4. Containers properly labeled and dated?
IZ:l
5. Secondary containment free from damage?
IZJ
6. Proper aisle spacing around containers?
00
7. Emergency communications system available/operable?
8. Firefighting equipment available/operable?
G. PCB BALLASTS/CAPACITORS
1. Any PCB waste containers in storage?
3l
2. Containers are in good condition, non-leaking, contained, labeled and dated?
[2g
3. All containers stored <270 days? Date will reach 270 days:___
H. BAKE STACK PLENUM AREA 90 DAY STORAGE AREA
Yes No NIA
FCD-0236 - Rev 22
EPA-RCRA CEI Report June 26, 2024
Page 75 of 76
Century Aluminum of South Carolina SCD097366165
1. Any hazardous waste containers in storage? 2. Containers in good condition, no leaks, clean, and properly closed? 3. Containers properly labeled and dated? 4. All containers stored <90 days? 5. Proper aisle spacing around containers? 6. Emergency communications system available/operable? 7. Firefighting equipment available/operable?
Weather Condition:@or Raining)
#
1. 2. 3. 4-5. 6.
Deficiency Comments
Corrective Action
u'- Rating:
Satisfactory U = Unsatisfactory
-l- nsector'-Signature: ----------
Kl
Completion Date
*If last Inspection of the quarter (Last inspection in March, June, September, and December) Mark Container ID
Numbers in the Table Below
(
138 SPL Container IDs
Cast House SPL Container IDs
STOP ifhazardous waste containers are not completely closed STOP ifcrack, leaks or holes are identified in the containment building STOP ifthere is not enough isle space between containers
STOP ifhazardous waste containers are not properly labeled STOP ifhazardous waste containers are not stored in the correct location STOP ifSPL found outside ofthe containment building or outside ofshipment containers
STOP iftruck traffic in cast house area is congested
STOP ifrelining traffic in 138 area is congested
STOP ifwaste fluid area traffic is congested from traffic to the waste fluid area or to building 139 STOP ifhazardous waste not properly contained. STOP ifhazardous waste containers are stored >90 days or if PCB containers stored >270 davs STOP ifSPL found leaking from the 138 dust collector or on the pad under the 138 dust collector
EPA-RCRA CEI Report June 26, 2024
FCD-0236 - Rev 22
Page 76 of 76
Century Aluminum of South Carolina SCD097366165