Document b5KrbdKomGyOO9jQjy3DVGdj3

J J. it. Fallon - St. leal* General offlea June 3* 1970 THSRHITOL FR SYSTEMS -- CCBTAE3SBNX AfiD DISPOSAL OF LEAKAGE C. I. Clay - St. Louis y. Davidson Los Angeles 0. F. Fague - Detroit J. A. Kellala - Pittsburgh R. F. Irwin - Houston J. S. Pullean - Kew York J. J. Roder - Chicago D. A. oison - St. Louis R. A. Garcia - Akrcn 8. T. Johnson - St. Lou la J* H. iiagsart - Brussels T. Katayasa - FMK Tokyo T* Cnesn - Montreal C. Paton - St. Louis Ve have always emphasized certain factors in Thertslncl FR systems to siniciiza or eliminate leakage so that operating personnel are not exposed to hot fluid or vapors. This emphasis must he reenforced with the user, the GSM's and with the design people. Cur objective is the elimination, or containment and collection of leakage from Thersinol FR systems. In addition we rust control the disposal of any Therninol FR collected froa leaks or frna the change out of the fluid in the system. The following Is proposed as a scans for eliminating the release of any Therainol FR from a system so that the fluid does not tecoae an environmental ccnt&insent. Leakage Generally there are four source* for leak* in a system ....Fittings -- weld all connections and flange those fittings where accessibility is desired. ....Pump Seal -- encourage use of canned pumps. Mechanical seals are a secondary choice. If they are used then encLaa seal or provide drip pan with a drain to a collections suisp. ....Seal at the heat using equipment -- stipulate that all drains be directed to a collection sunp. Install drip pans at rotary joints. ....Expansion Tank Vent -- stipulate that vent be directed to a cold seal tank, or catch pot or drum to contain vapor condensation and contain light ends. DSW 312764 STLCOPCB4054435 In reviewing drawings or systems specify check valves at selected points to Eiiniisi2e fmid discharge in the rare case of a rupture at the using equipment or in the heater coil. The control, collection and disposal of leakage is primarily the users responsibility, fee cu3t make him aware of this responsibility and of our desire to w^ric with hlra. Disposal If leakage does occur it should be collected and placed in drums. The same procedure should be followed if the user wishes to change out his fluid charge. In a fluid change out the user cay wish to reclaim under our regular policy. * Material for disposal should be returned tot Monsanto Company W. 0. KruKmrich Plant Sauget, Illinois Attx Supervisor, Department 2$6 Advise your sales correspondent and W. E. Cordon in Distribution that material is being returned for disposal. In this way the proper papers can be prepared and the user invoiced for this disposal service. The charge for this disposal is $.03/lb The user pays the c~st cf the druse end t-he freight* The heat transfer system can .generally be considered a closed system, leakage can be easily controlled, collected and disposed. The user sust be made aware oC this. General The Therein1 PR systems ere usually the vital part or a process, and the user has decided to protect his inrest&ent and his personnel by using a fire resistant fluid. There is a very strong cooperative atmosphere and working; relation ship with our Therein1 PR users and prospects. They need and want the protection afforded by a fire resistant fluid, they want a leak free stea and good labor relations and consequent6iwill design a leak free system -- your customer will appreciate your interest and will knew that he has and will continue to have the best possible protection with a fire resistant fluid. /dn J, R, Fallen DSW 312765 STLCOPCB4054436