Document b5JYKpxMeggzdyMeBYxeJ5deZ

40 CHAPTER 4 1959 Guide where 0 = Dt/Di. The quantity 1fy/1 -- is the velocity of approach factor as generally used, with 8 being the ratio of the throat or orifice diameter to the pipe diameter. Since Ap/p* is small and tiie mass flow is (46) (47) The volume flow is then (Cocfficmtf t&own at a function of Reynolds Nember and Ratio, A/A\ J From Reference 4. Used by permission. Fig. 7.... Dimensions and Flow Coefficient for Standard Square-edged Orifice with Corner Taps or Annular Slits the flow in the nozzle. If the ratio of p* to pi is decreased from unity, the mass rate of discharge, as well as the volume, in creases from zero to a maximum, as shown by the solid sec tion of the curve in Fig. 6; thereafter, as p*/pi is decreased further, the discharge is constant, as indicated by the hori zontal line. The value of p at the maximum point is the critical pressure, or pe, and it is seen that pe is approxi mately 53 percent of pi when air is flowing. .To find the velocity at the critical pressure, it is assumed that the upstream velocity Pi is so small as to be negligible. Using, the subscript c. to indicate conditions at the critical point, from Equation 29 or W-7] m Substituting the critical pressure ratio from Equation 40 it follows that (43) or that the velocity at the throat is equal to the local sonic velocity. In developing the working equations for orifices and noz zles, it is customary to start with the incompressible form of tiie flow Equation 38. In this case both Af, and Af, are small quantities, pi = pi, and (pi -- pt)/pt- = Ap/p* is small. Retaining only first order terms, it follows from Equation 35 that Af,- A, Mi = A. (44) so that /Ti 4/ V-l' -.C4t/A,)`. (45) 0 - A, ^7|= y/isie.vb - A. yfrj, 8) FLOW MEASUREMENT The measurement of quantity of flow of fluids is generally accomplished either by making observations on the change of state due to flow system configuration, such as the pres sure drop across a metering orifice, or by the displacement of some device, such as a rotating vane system. The .selection of the metering system will be determined by the type of fluid, the precision of measurement desired, the cost of equip ment and installation, the range of flow quantity, the ease of maintenance, and the method of observation and record ing. Fluid meters may be classified as'follows: (1) Head Meiers (Pressure Sensitive), which may.be of Venturi, flow nozzle, orifice plate, or Pitot tube types; (2) Area Meters, which may be of gate, tapered lube, or tapered plug types; (3) Force Meters, which may be of vane, propeller, or turbine types; (4) Quantity Meters, which may be of weighing tank, recipro cating piston, or geared impeller types. Rate meters are generally of the first three groups, al though rates are obtainable from timed observations of quantity meters. Similar quantity measurements can be ob tained by suitable integration of rate meter indications. Head Meters The head meter is of sufficient flexibility so that almost any type of flow measurement can be handled. For this reason, standard and reference measurements are usually made in this way. With proper care, extreme precision can be ob tained. Also, an inexpensive installation can be made to give moderate precision. In general, a head meter requires fairly competent installation and maintenance to give satisfactory service. Among the types of head meters, the Venturi has the ad vantage of having a low pressure loss, but requires consider able length of space. The orifice plate reduces the required length to a minimum at the cost of considerable pressure drop.. The flow nozzle represents a compromise, but must be cali brated individually, or made with extreme care from standard specifications, to obtain & good precision of measurement. Standard configurations, for representative orifice plates and flow nozzles, are shown in Figs. 7 and 8, respectively. Ad ditional specifications are given in References 2, 3, and 4 at end of chapter. The measurement-of flow in head meters is dependent 41 From Roforoneo 3. Us*J by poraitdoo of ASMF. Ng. 8 .:.. Dimensions for International Standards Association Flow Nozzle upon observations of a static pressure difference between two parts of-the system. Standard locations for these static pres sure measurements are illustrated in Figs 8 and 16. In general, there exists a reduction in area, either by a smooth contour as in the case of a Venturi or flow nozzle, or by a vena con tracts following an orifice. In either case, the flow will be given by a suitable modification of Equations 47 and 48. Adding a correction term, these become Rg. 9___ Flow Coefficients, K, for Square-edged Orifice Plates and Flange Taps in Smooth Pipe tv = g, -y/2gp&p (49) and 0 - 0L= VijK, (K>) In all cases, Aj refers to the minimum area of the Venturi, nozzle, or orifice. Hie correction factor C is introduced to account for any loss due to departure from isentropic flow, and for any deviation between the downstream measured pressure and the actual pressure at the minimum section. Since these corrections are usually dependent on configura tion, as described by the ratio of upstream to minimum area Ai/At, it is often convenient to introduce a combined flow coefficient, K which is From Fig. 36d of ffeferanca 3. Rg. 10.... Flow Coefficients, K, for Square-edged Orifice Plates and Radius Taps in Smooth Pipe so that Vi -- p* (51) w = KAj%/2ffpAp (52) and Q - KAt VSgh, (53) The coefficients K and C will be determined by the area ratio A1/A1, or by the diameter ratio Di/Dt and the Reynolds number. Extensive data are available from various sources.1,4 Figs. 9, 10, 11, 12 show representative values of K based on Ns., the Reynolds number, and the ratio of diameter of the orifice or nozzle throat to pipe diameter. In any specific application, numerical values for areas, densities, and pressure units can be substituted in Equations 52 and 53 to obtain compact workiog formulas. In planning flow measurements, standard flow meter dimensions and standard pressure tap locations should preferably be used so Rg. 11....Flow Coefficients, K, for Square-edged Orifice Plates and Vena Contracto Taps, in Smooth Pipe