Document b5DY3K6OnwQvx3a4p6dKbg4ny

3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-05-04 Final Report Analysis of PFOA, PFBS, PFHS, and PFOS in Groundwater Samples Collected from Decatur, Alabama 3rd Quarter 2013 Laboratory Request Number: ISO13-05-04 Method Requirement: 3M Method ETS-8-044.1 Report Date - Date of Final Signature Testing Laboratory 3M EHS&S Operations 3M Environmental Laboratory Building 260-5N-17 Maplewood, MN 55144-1000 Requester Gary Hohenstein 3M Building 224-5W-03 Saint Paul, MN 55144-1000 Phone: (651) 737-3570 The testing reported herein meet the requirements of ANSI/ISO/IEC 17025:2005 "General Requirements for the Competence of Testing and Calibration Laboratories", in accordance with the A2LA Testing Certificate # 2052.01. Additionally, the laboratory's quality system has been audited and was determined to be in conformance with the EPA GLPs (40 CFR 792) by an independent A2LA assessment. PAGE 1 OF 28 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-05-04 3M Environmental Laboratory 3M Environmental Laboratory Technical Director: William K. Reagen, Ph.D. 3M Principal Analytical Investigator: Susan Wolf Report Author: Chelsie Grochow Analytical Report ISO13-05-04 Analysis of PFOA, PFBS, PFHS, and PFOS in Groundwater Samples Collected from Decatur, AL 3rdQuarter 2013 Report Date: Date of Final Signature 1 Introduction/Summary The 3M Environmental Laboratory prepared and analyzed water samples collected by Weston Solutions personnel from Decatur, AL. Samples were collected from September 27 - October 11, 2013 and returned to the 3M Environmental Laboratory on October 16, 2013 at ambient conditions. All samples were analyzed for perfluorooctanoic acid (PFOA), perfluorobutane sulfonate (PFBS), perfluorohexane sulfonate (PFHS) and perfluorooctane sulfonate (PFOS) under laboratory project number ISO13-05-04. The 3M Environmental Laboratory prepared sample containers for eighteen groundwater well locations. Each empty container was marked with a "fill to here" line that corresponded to a final volume of 200 mL. Sample bottle sets for each groundwater sampling location included a field sample, field sample duplicate, and at least one field spike sample. Containers designated for field matrix samples were fortified with an appropriate matrix spike solution containing PFOA, PFBS, PFHS, and PFOS prior to being sent to the field for sample collection. Samples were prepared and analyzed by method ETS-8-044.1 "Method of Analysis for the Determination of Perfluorinated Compounds in Water by LC/MS/MS; Direct Injection Analysis". Select internal standards were used to aid in the data quality objectives. Table 1 summarizes the sample results using the analytical method identified above. All results for quality control samples prepared and analyzed with the samples will be reported and discussed elsewhere in this report. The testing reported herein meet the requirements of ANSI/ISO/IEC 17025:2005 "General Requirements for the Competence of Testing and Calibration Laboratories", in accordance with the A2LA Testing Certificate # 2052.01. Additionally, the laboratory's quality system has been audited and was determined to be in conformance with the EPA GLPs (40 CFR 792) by an independent A2LA assessment. PAGE 2 OF 28 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-05-04 Table 1. Sample Results Summary (1) 3M LIMS ID ISO13-05-04-001 ISO13-05-04-002 ISO13-05-04-005 ISO13-05-04-006 ISO13-05-04-008 ISO13-05-04-009 ISO13-05-04-011 ISO13-05-04-012 ISO13-05-04-015 ISO13-05-04-016 ISO13-05-04-019 ISO13-05-04-020 ISO13-05-04-023 ISO13-05-04-024 ISO13-05-04-026 ISO13-05-04-027 ISO13-05-04-029 ISO13-05-04-030 Sample Description DAL-GW-203L-0-131001 DAL-GW-203L-DB-131001 Average %RPD Sample/Sample Dup DAL-GW-220R-0-131003 DAL-GW-220R-DB-131003 Average %RPD Sample/Sample Dup DAL-GW-220L-0-131003 DAL-GW-220L-DB-131003 Average %RPD Sample/Sample Dup DAL-GW-222R-0-131001 DAL-GW-222R-DB-131001 Average %RPD Sample/Sample Dup DAL-GW-227R-0-131001 DAL-GW-227R-DB-131001 Average %RPD Sample/Sample Dup DAL-GW-227L-0-131001 DAL-GW-227L-DB-131001 Average %RPD Sample/Sample Dup DAL-GW-310R-0-131002 DAL-GW-310R-DB-131002 Average %RPD Sample/Sample Dup DAL-GW-312R-0-131011 DAL-GW-312R-DB-131011 Average %RPD Sample/Sample Dup DAL-GW-317L-0-131002 DAL-GW-317L-DB-131002 Average %RPD Sample/Sample Dup PFOA Concentration (ng/mL) 153 152 153 0.65 51.5 47.0 49.3 9.1 26.3 26.4 26.4 0.38 317 323 320 (23) 1.9 241 235 238 (2) 2.5 178 172 175 3.4 953 928 941 2.7 6740 6860 6800 1.8 0.290 0.308 0.299 (2) 6.0 PFBS Concentration (ng/mL) 23.3 24.0 23.7 3.0 8.38 7.85 8.12 6.5 4.88 5.04 4.96 3.2 44.3 46.6 45.5 5.1 15.3 14.9 15.1 2.6 264 254 259 3.9 1310 1300 1310 0.76 7220 7300 7260 1.1 <0.0250 <0.0250 <0.0250 (2) NA PFHS Concentration (ng/mL) 147 147 147 0.0 41.6 39.0 40.3 6.5 17.0 17.5 17.3 2.9 298 317 308 6.2 58.3 55.8 57.1 4.4 83.0 81.9 82.5 1.3 310 304 307 2.0 1320 1280 1300 3.1 0.0932 0.104 0.0986 (2) 11 PFOS Concentration (ng/mL) 787 794 791 0.88 80.9 76.8 78.9 5.2 49.5 49.5 49.5 0.0 444 474 459 6.5 660 653 657 1.1 826 838 832 1.4 778 755 767 3.0 2850 2860 2860 0.35 0.241 0.245 0.243 (2) 1.6 NA = Not Applicable (1) All samples associated with the reported sampling location were analyzed by external standard calibration unless noted otherwise. The analytical method uncertainties for the reported results using method ETS-8-044.1 by direct injection using solvent dilution are as follows: PFOA 14%, PFBS 14%, PFHS 12%, and PFOS 15%. (2) All samples associated with the reported sampling location were analyzed by internal standard calibration. The analytical method uncertainties for the reported results using method ETS-8-044.1 by direct injection are as follows: PFOA 17%, PFBS 17%, PFHS 16%, and PFOS 18%. (3) The analytical method uncertainty has been expanded to 34% for PFOA. See section 4 for further discussion. PAGE 3 OF 28 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-05-04 Table 1 continued. Sample Results Summary (1) 3M LIMS ID ISO13-05-04-032 ISO13-05-04-033 ISO13-05-04-035 ISO13-05-04-036 ISO13-05-04-039 ISO13-05-04-040 ISO13-05-04-043 ISO13-05-04-044 ISO13-05-04-047 ISO13-05-04-048 ISO13-05-04-051 ISO13-05-04-052 ISO13-05-04-054 ISO13-05-04-055 ISO13-05-04-057 ISO13-05-04-058 ISO13-05-04-060 ISO13-05-04-061 Sample Description DAL-GW-324L-0-130927 DAL-GW-324L-DB-130927 Average %RPD Sample/Sample Dup DAL-GW-RW327R-0-131011 DAL-GW-RW327R-DB-131011 Average %RPD Sample/Sample Dup DAL-GW-328R-0-130927 DAL-GW-328R-DB-130927 Average %RPD Sample/Sample Dup DAL-GW-328L-0-130927 DAL-GW-328L-DB-130927 Average %RPD Sample/Sample Dup DAL-GW-330R-0-130927 DAL-GW-330R-DB-130927 Average %RPD Sample/Sample Dup DAL-GW-330L-0-130927 DAL-GW-330L-DB-130927 Average %RPD Sample/Sample Dup DAL-GW-RW331S-0-131011 DAL-GW-RW331S-DB-131011 Average %RPD Sample/Sample Dup DAL-GW-335R-0-131002 DAL-GW-335R-DB-131002 Average %RPD Sample/Sample Dup DAL-GW-GRS04-0-131011 DAL-GW-GRS04-DB-131011 Average %RPD Sample/Sample Dup PFOA Concentration (ng/mL) 219 203 211 7.6 1180 1190 1190 (2) 0.84 409 397 403 (2) 3.0 108 109 109 (2) 0.92 278 281 280 1.1 83.9 82.5 83.2 1.7 422 428 425 1.4 4680 4650 4670 0.64 5530 5410 5470 2.2 PFBS Concentration (ng/mL) 74.6 69.7 72.2 6.8 59.9 63.8 61.9 6.3 33.8 32.5 33.2 3.9 45.7 44.9 45.3 (2) 1.8 1430 1440 1440 0.69 1360 1310 1340 3.7 432 427 430 1.2 1230 1250 1240 1.6 2830 2730 2780 3.6 PFHS Concentration (ng/mL) 55.3 53.3 54.3 3.7 159 169 164 6.1 52.4 51.0 51.7 2.7 17.6 16.1 16.9 8.9 163 163 163 0.0 462 455 459 1.5 160 161 161 0.62 1650 1660 1660 0.60 9540 9140 9340 4.3 PFOS Concentration (ng/mL) 78.0 77.7 77.9 0.39 617 708 663 14 274 265 270 3.3 1.29 1.18 1.24 8.9 676 688 682 1.8 181 177 179 2.2 465 457 461 1.7 6440 6510 6480 1.1 2690 2940 2820 8.9 NA = Not Applicable (1) All samples associated with the reported sampling location were analyzed by external standard calibration unless noted otherwise. The analytical method uncertainties for the reported results using method ETS-8-044.1 by direct injection using solvent dilution are as follows: PFOA 14%, PFBS 14%, PFHS 12%, and PFOS 15%. (2) All samples associated with the reported sampling location were analyzed by internal standard calibration. The analytical method uncertainties for the reported results using method ETS-8-044.1 by direct injection are as follows: PFOA 17%, PFBS 17%, PFHS 16%, and PFOS 18%. (3) The analytical method uncertainty has been expanded to 34% for PFOA. See section 4 for further discussion. PAGE 4 OF 28 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-05-04 2 Methods - Analytical and Preparatory 2.1 Methods Analysis was completed using 3M Environmental Laboratory Method ETS-8-044.1 "Method of Analysis for the Determination of Perfluorinated Compounds in Water by LC/MS/MS; Direct Injection Analysis". Table 2. Target Analytes Target Analytes Perfluorobutanoic Acid (C4 Acid) Perfluorooctanoic Acid (C8 Acid) Perfluorobutanesulfonate (C4 Sulfonate ) Perfluorooctanesulfonate (C8 Sulfonate) Acronym PFOA PFBS PFHS PFOS Reference Material Structure Linear + Branched Linear Linear Linear + Branched 2.2 Sample Collection All samples were collected in 250 mL NalgeneTM (high-density polyethylene) bottles prepared at the 3M Environmental Laboratory. Samples were collected from September 27 - October 11,2013 and returned to the 3M Environmental Laboratory on October 16, 2013 at ambient conditions. Prior to sample collection, bottles designated for field matrix spikes were spiked in the laboratory with a known volume of an appropriate matrix spiking solution containing PFOA, PFBS, PFHS, and PFOS. Table 3. Sample Description Key Code. String Number Example 1 2 3 4 5 6 String Descriptor DAL-GW-317L-0-131002 Sample Location Sample Type Well Identifier Well Level Sampling Date Sample Type Example DAL= Decatur, Alabama GW= Ground Water Example: 317 R = Residuum shallow water-bearing zone L = Bedrock water-bearing zone S = Epikarst middle water-bearing zone 131002 - October 2, 2013 0 =primary sample DB =duplicate sample FMS = Field Matrix Spike LS = Low field matrix spike HS = High field matrix spike PAGE 5 OF 28 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-05-04 2.3 Sample Preparation All samples and laboratory control spikes were diluted with methanol prior to sample analysis. Samples requiring a 1:10 dilution were prepared by removing a 1.0 mL aliquot of the well mixed sample and diluting it with 9.0 mL of methanol. Samples requiring a 1:100 dilution were prepared by removing a 0.1 mL aliquot of the well mixed sample and diluting it with 9.9 mL of methanol. Sample injection values were decreased for some samples if a larger dilution factor was desired. Samples that did not have appropriate field matrix spike (FMS) levels based on the initial analysis, a laboratory matrix spike (LMS) sample was prepared by spiking the target analytes in a diluted aliquot of the primary sample (nominal concentration of 1000 ng/mL or 5000 ng/mL). Samples with low FMS recoveries based on the initial analysis, were analyzed with internal standard. Samples requiring dilution were diluted with synthetic groundwater and fortified with internal standard (nominal concentration of 1 ng/mL). Sample set 317L, trip blank sample, and rinseate blank were also analyzed using internal standard and prepared by removing an aliquot of well mixed sample and fortifying with internal standard prior to sample analysis. During the preparation of the laboratory control samples, an aliquot of an internal standard spiking solution was added to the laboratory control samples (nominal concentration of 1 ng/mL). 2.4 Analysis All samples and quality control samples were analyzed for the four target analytes using high performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS). Pertinent instrument parameters, the liquid chromatography gradient program, and the specific mass transitions analyzed are described in the tables below. Due to the nature of the sample, the wide range of concentrations found in the sample, and the environmental occurrence of multiple isomers of the laboratory's analytes of interest, the software used for processing the analytical results is not able to consistently integrate the analytical peak, manual integration of the analytical peak is necessary. All manual integrations are performed following the procedures outlined in method ETS-12-010. The consistency of the laboratory's integration is ensured through the training of laboratory personnel, the peer review process required for all manual integrations, the review of manual integrations by the QAU, and where necessary the review of manual integrations by laboratory management. PAGE 6 OF 28 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-05-04 Table 4. Instrument Parameters Instrument Name Analysis Dates Analytical Method Liquid Chromatograph Guard column Analytical column Injection Volume Mass Spectrometer Ion Source Polarity Software ETS Kirk 10/18/13, 10/21/13, 10/22/13 ETS-8-044.1 Agilent 1260 Betasil C18 (4.6 mm X 100 mm), 5 g Betasil C18 (4.6 mm X 100 mm), 5 g 5 or 20 |jL Applied Biosystems TripleQuad 5500 Turbo Spray Negative Analyst 1.6.1 Table 5. Liquid Chromatography Gradient Program Step 0 1 2 3 4 5 6 7 8 9 Total Time (min) 0 0.5 4.0 6.0 11.0 13.0 13.5 16.0 16.5 19.0 Flow Rate (pL/min) 750 750 750 750 750 750 750 750 750 750 Table 6. Mass Transitions 2 mM Ammonium Acetate 90.0 90.0 70.0 70.0 20.0 20.0 10.0 10.0 90.0 90.0 Methanol 10.0 10.0 30.0 30.0 80.0 80.0 90.0 90.0 10.0 10.0 Analyte Mass Transition Q1/Q3 Internal Standard (1) Mass Transition Q1/Q3 Reference Material Structure 413/369 PFOA 413/219 [13Cs]PFOA 421/376 Linear + Branched 413/169 PFBS PFHS 299/80 299/99 399/99 399/80 [18O2]PFBS [13Cs]PFHS 303/84 402/80 Linear Linear 499/99 PFOS 499/80 [13Cs]-PFOS 507/80 Linear + Branched 499/130 Dwell time was 20 msec for each transition. The individual transitions were summed to produce a "total ion chromatogram" (TIC), which was used for quantitation. (1) Internal standard was used for the analysis on 10/22/13. PAGE 7 OF 28 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-05-04 3 Data Analysis 3.1 Calibration External Standard Calibration Analysis: Samples were analyzed against an external standard calibration curve. Calibration standards were prepared by spiking known amounts of the stock solution containing the target analytes into 90:10 methanol:laboratory Milli-QTM water. A total of eleven spiked standards ranging from 0.02 ng/mL to 50 ng/mL (nominal) were analyzed. A quadratic, 1/x weighted, calibration curve of the standard peak area counts was used to fit the data for each analyte. The data were not forced through zero during the fitting process. Calculating the standard concentrations using the peak area counts and the resultant calibration curve confirmed accuracy of each curve point. Internal Standard Calibration Analysis: Samples were analyzed against a matrix-matched stable isotope internal standard calibration curve. Calibration standards were prepared by spiking known amounts of stock solutions into laboratory prepared reagent water. The calibration standards contained an internal standard mix at a nominal concentration of 1 ng/mL. A total of fourteen calibration standards ranging from 0.025 ng/mL to 50 ng/mL (nominal) were analyzed with the prepared samples. A quadratic, 1/x weighted, calibration curve of the ratio of the standard peak area counts over the internal standard peak area counts was used to fit the data for each analyte. The data were not forced through zero during the fitting process. Calculating the standard concentrations using the peak area ratios and the resultant calibration curve confirmed accuracy of each curve point. For each calibration curve, the reference standards of PFOA and PFOS used to prepare the calibration standards consisted of both linear and branched isomers. Each curve point was quantitated using the overall calibration curve and reviewed for accuracy. Method calibration accuracy requirements of 10025% (10030% for the lowest curve point) were met for all analytes. The correlation coefficient (r) was greater than 0.995 for all analytes. 3.2 System Suitability A calibration standard was analyzed four times at the beginning of the analytical sequence to demonstrate overall system suitability. The acceptance criteria for system suitability samples is less than or equal to 5% relative standard deviation (RSD) for peak area or peak area ratio and retention time criteria of less than or equal to 2% RSD. These criteria were met for all analytes. 3.3 Limit of Quantitation (LOQ) The LOQ as defined in method ETS-8-044.1 is the lowest non-zero calibration standard in the curve that meets linearity and accuracy requirements and for which the peak area ratio (or peak area) is at least two times the average peak area ratio (or peak area) of the method blanks. The LOQs associated with the sample analysis are listed in the table below. Table 7. LOQ Analysis Date 10/18/13 Calibration External Standard 10/21/13 External standard 10/22/13 Internal standard Dilution Factor 10 100 400 100 400 1 10 100 PFBA LOQ, ng/mL 0.192 1.92 7.68 1.92 7.68 0.0240 0.240 2.40 PFOA LOQ, ng/mL 0.200 2.00 8.00 2.00 8.00 0.0250 0.250 2.50 PFBS LOQ, ng/mL 0.200 2.00 8.00 2.00 8.00 0.0400 0.400 4.00 PFOS LOQ, ng/mL 0.185 1.85 7.40 1.85 7.40 0.0232 0.232 2.32 PAGE 8 OF 28 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-05-04 3.4 Continuing Calibration During the course of the analytical sequence, several continuing calibration verification samples (CCVs) were analyzed to confirm that the instrument response and the initial calibration curve were still in control. The method acceptance criteria of 100% 25% was met for all analytes for all analyses. 3.5 Blanks Three types of blanks were prepared and analyzed with the samples: method/procedural blanks, a field/trip blank, and a single equipment rinseate blank. Method blank results were reviewed and used to evaluate method performance to determine the LOQ for each analyte. 3.6 Lab Control Spikes (LCSs) Low, mid, and high lab control spikes were prepared with each sample preparation batch for the target analytes and analyzed in triplicate. LCSs were prepared by spiking known amounts of the analytes into synthetic groundwater or laboratory Milli Q water to produce the desired concentration. The LCS samples were then diluted in a similar manner as the samples (if diluted) prior to sample analysis. The method acceptance criteria, average of each level of LCS should be within 100% 20% with an RSD <20%, was met for all LCS samples. Note: Lab matrix spike samples (LMS) for locations RW312R and 333L were prepared on 10/21/13 without additional LCSs. This is a deviation from the method that states that LCSs should be prepared each day that samples are aliquoted. While this is a deviation from the method, the LMS samples were analyzed in an analytical batch with samples for which LCS samples were prepared. Both the LMS and LCS samples analyzed on 10/21/13 met method acceptance criteria. All LCSs were used in the determination of the analytical method uncertainty in section 3.7. The following calculations were used to generate data in Table 8. LCS Percent Recovery Calculated Concentration * 10 0 % Spike Concentration standard deviation LCS replicates LCS% RSD = 100% average LCS recovery PAGE 9 OF 28 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-05-04 Table 8. Lab Control Spike Results ETS-8-044.1 Analyzed 10/18/13 External Standard Calibration Lab ID LCS-131018-1 LCS-131018-2 LCS-131018-3 Average %RSD LCS-131018-4 LCS-131018-5 LCS-131018-6 Average %RSD LCS-131018-7 LCS-131018-8 LCS-131018-9 Average %RSD PFOA (Linear and Branched) Spiked Calculated Concentration Concentration (ng/mL) (ng/mL) %Recovery 0.191 0.191 0.191 4.77 4.77 4.77 38.2 38.2 38.2 0.193 0.206 0.193 103% 3.9% 5.15 5.14 5.22 108% 0.53% 37.8 35.9 36.6 96.3% 2.6% 101 108 101 108 108 109 98.9 94.0 95.9 Spiked Concentration (ng/mL) 0.200 0.200 0.200 4.98 4.98 4.98 39.8 39.8 39.8 PFBS Calculated Concentration (ng/mL) 0.212 0.221 0.210 107% 3.0% 5.20 5.38 5.33 106% 2.0% 40.0 37.8 38.5 97.5% 3.2% %Recovery 106 111 105 104 108 107 101 94.9 96.7 ETS-8-044.1 Analyzed 10/18/13 External Standard Calibration Lab ID LCS-131018-1 LCS-131018-2 LCS-131018-3 Average %RSD LCS-131018-4 LCS-131018-5 LCS-131018-6 Average %RSD LCS-131018-7 LCS-131018-8 LCS-131018-9 Average %RSD Spiked Concentration (ng/mL) PFHS Calculated Concentration (ng/mL) 0.200 0.200 0.200 4.98 4.98 4.98 39.8 39.8 39.8 0.202 0.209 0.207 103% 1.5% 5.29 5.34 5.40 107% 1.4% 40.2 36.6 38.0 96.1% 4.8% %Recovery 101 104 103 106 107 109 101 91.9 95.4 PFOS (Linear and Branched) Spiked Concentration (ng/mL) Calculated Concentration (ng/mL) %Recovery 0.185 0.185 0.185 4.61 4.61 4.61 36.9 36.9 36.9 0.201 0.211 0.202 111% 2.6% 5.21 5.34 5.30 115% 1.3% 38.3 35.7 36.8 100% 3.6% 109 114 109 113 116 115 104 96.8 99.9 PAGE 10 OF 28 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-05-04 Table 8 continued. Lab Control Spike Results ETS-8-044.1 Analyzed 10/21/13 External Standard Calibration Lab ID LCS-131018-1 LCS-131018-2 LCS-131018-3 Average %RSD LCS-131018-4 LCS-131018-5 LCS-131018-6 Average %RSD LCS-131018-7 LCS-131018-8 LCS-131018-9 Average %RSD PFOA (Linear and Branched) Spiked Calculated Concentration Concentration (ng/mL) (ng/mL) %Recovery 0.191 0.191 0.191 4.77 4.77 4.77 38.2 38.2 38.2 0.202 0.207 0.212 108% 2.3% 5.31 5.35 5.35 112% 0.52% 41.5 38.6 40.5 105% 3.8% 106 108 111 111 112 112 109 101 106 Spiked Concentration (ng/mL) 0.200 0.200 0.200 4.98 4.98 4.98 39.8 39.8 39.8 PFBS Calculated Concentration (ng/mL) 0.220 0.221 0.221 111% 0.52% 5.35 5.62 5.61 111% 3.1% 43.1 39.6 42.1 105% 4.2% %Recovery 110 111 111 107 113 113 108 99.6 106 ETS-8-044.1 Analyzed 10/21/13 External Standard Calibration Lab ID LCS-131018-1 LCS-131018-2 LCS-131018-3 Average %RSD LCS-131018-4 LCS-131018-5 LCS-131018-6 Average %RSD LCS-131018-7 LCS-131018-8 LCS-131018-9 Average %RSD Spiked Concentration (ng/mL) PFHS Calculated Concentration (ng/mL) 0.200 0.200 0.200 4.98 4.98 4.98 39.8 39.8 39.8 0.215 0.219 0.210 107% 1.9% 5.32 5.53 5.42 109% 1.8% 41.7 38.2 41.3 102% 4.8% %Recovery 108 109 105 107 111 109 105 96.0 104 PFOS (Linear and Branched) Spiked Concentration (ng/mL) Calculated Concentration (ng/mL) %Recovery 0.185 0.185 0.185 4.61 4.61 4.61 36.9 36.9 36.9 0.212 0.215 0.215 116% 0.50% 5.45 5.58 5.59 120% 1.4% 40.9 37.4 40.3 107% 4.9% 115 116 116 118 121 121 111 101 109 PAGE 11 OF 28 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-05-04 Table 8 continued. Lab Control Spike Results ETS-8-044.1 Analyzed 10/22/13 Internal Standard Calibration Lab ID LCS-131022-1 LCS-131022-2 LCS-131022-3 Average %RSD LCS-131022-4 LCS-131022-5 LCS-131022-6 Average %RSD LCS-131022-7 LCS-131022-8 LCS-131022-9 Average %RSD PFOA (Linear and Branched) Spiked Calculated Concentration Concentration (ng/mL) (ng/mL) %Recovery 0.190 0.190 0.190 4.74 4.74 4.74 38.0 38.0 38.0 0.178 0.195 0.197 100% 5.6% 5.04 4.82 5.00 105% 2.2% 37.5 36.7 36.0 96.7% 2.1% 93.9 103 104 106 102 106 98.8 96.5 94.7 Spiked Concentration (ng/mL) 0.199 0.199 0.199 4.95 4.95 4.95 39.6 39.6 39.6 PFBS Calculated Concentration (ng/mL) 0.196 0.203 0.196 99.6% 2.1% 5.20 5.13 5.29 105% 1.5% 42.2 39.3 39.2 102% 4.5% %Recovery 98.4 102 98.4 105 104 107 107 99.3 98.9 ETS-8-044.1 Analyzed 10/22/13 Internal Standard Calibration Lab ID LCS-131022-1 LCS-131022-2 LCS-131022-3 Average %RSD LCS-131022-4 LCS-131022-5 LCS-131022-6 Average %RSD LCS-131022-7 LCS-131022-8 LCS-131022-9 Average %RSD Spiked Concentration (ng/mL) PFHS Calculated Concentration (ng/mL) 0.199 0.199 0.199 4.95 4.95 4.95 39.6 39.6 39.6 0.199 0.204 0.208 103% 2.5% 5.22 5.29 5.21 106% 1.1% 39.9 38.3 37.9 97.8% 2.9% %Recovery 99.8 103 105 105 107 105 101 96.7 95.6 PFOS (Linear and Branched) Spiked Concentration (ng/mL) Calculated Concentration (ng/mL) %Recovery 0.184 0.184 0.184 4.59 4.59 4.59 36.7 36.7 36.7 0.194 0.203 0.191 106% 3.0% 4.89 4.93 4.93 107% 0.0% 38.9 37.2 36.7 102% 3.2% 105 110 104 107 107 107 106 101 99.9 PAGE 12 OF 28 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-05-04 3.7 Analytical Method Uncertainty Analytical method uncertainty is based on historical QC data that is control charted and used to evaluate method accuracy and precision. The method uncertainty is calculated following ETS-12012.2. The standard deviation is calculated for the set of accuracy results (in %) obtained for the QC samples. The expanded uncertainty is calculated by multiplying the standard deviation by a factor of 2, which corresponds to a confidence level of 95%. Table 9. Analytical Method Uncertainty Analyte PFOA PFBS PFHS PFOS PFOA PFBS PFHS PFOS Calibration External External External External Internal Internal Internal Internal Standard Deviation (%) 6.91 6.88 6.04 7.65 8.54 8.32 7.79 8.80 Method Uncertainty 14% 14% 12% 15% 17% 17% 16% 18% 3.8 Field Matrix Spikes (FMS) Field matrix spike sample containers were prepared for all locations to verify that the analytical method is applicable to the collected matrix. Field matrix spikes are generated by adding a measured volume of field sample to a container spiked by the laboratory with the target analytes prior to shipping sample containers to the field for sample collection. Field matrix spike recoveries within method acceptance criteria of 10030% confirm that "unknown" components in the sample matrix do not significantly interfere with the extraction and analysis of the analytes of interest. The reference standards for PFOA and PFOS in the field matrix spiking solution consisted of linear and branched isomers. The locations for which FMS sample containers were prepared are listed in Table 9. Field matrix spikes are presented in section 4 of this report. TMFMS Recovery =(-S--a-m--p-l-e--C--o-n--c-e--n-t-r-a-t-i-o-n---o-f--F--M--S------A--v-e--r-a-g2e---C--o-n--c-e-n--t-r-a-t-i-o-n---:-F-i-e-l-d--S--a-m--p-l-e--&---F-i-e--ld---S-a--m--p-l-e--D--u-p--.) *100% Spike Concentration PAGE 13 OF 28 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-05-04 Table 10. Field Matrix Spike Concentrations Sampling location 203L 220R and 220L 222R and 227L 227R and 328R 330R 310R, RW312R, and RW331S 317L 324L RW327R 328L 330L 335R and GRS04 Trip Blank Spike Level Low High FMS Low High Low High Low High FMS FMS FMS Low High Low High FMS FMS Low Mid High PFOA ng/mL 100 501 50.0 100 501 50.0 501 501 1000 1000 1.00 200 100 1000 1.00 100 501 5010 1.00 100 1000 PFBS ng/mL 100 502 50.0 100 502 50.0 502 502 1000 1000 1.00 200 100 1000 1.00 100 502 5020 1.00 100 1000 PFHS ng/mL 99.8 499 49.9 99.8 499 49.9 499 499 998 998 0.999 200 99.8 998 0.999 99.8 499 4990 0.999 99.8 998 PFOS ng/mL 99.4 497 49.7 99.4 497 49.7 497 497 994 994 1.00 199 99.4 994 1.00 99.4 497 4970 1.00 99.4 994 3.9 Lab Matrix Spikes (LMS) Due to inappropriate field matrix spike levels, lab matrix spike samples were prepared for locations RW312R and 330L to verify that the analytical method is applicable to the collected matrix. Lab matrix spikes are generated by adding a measured volume of spiking solution to an aliquot of the primary sample post-dilution from each sample set. The LMS sample was spiked at a nominal concentration of 5000 ng/mL for sampling location RW312R and 1000 ng/mL for sampling location 330L. Lab matrix spike recoveries within method acceptance criteria of 10030% confirm that "unknown" components in the sample matrix do not significantly interfere with the extraction and analysis of the analytes of interest. The reference standards for PFOA and PFOS in the field matrix spiking solution consisted of linear and branched isomers. Lab matrix spikes are presented in section 4 of this report. LM S Recovery - (Sample Concentration of LM S - Concentration:Field Sample ) * 100% Spike Concentration PAGE 14 OF 28 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-05-04 4 Data Summary and Discussion The tables below summarize the sample results and target analyte field matrix spike recoveries for the sampling locations as well as the T rip Blank. Where applicable, the data tables also include the recovery results for a lab matrix spike. Each table provides the average concentration and the relative percent difference (%RPD) of the sample and sample duplicate. Results and average values are rounded to three significant figures. Percent relative difference (%RPD) values are rounded to two significant figures. Because of rounding, values may vary slightly from those listed in the raw data. Field matrix spikes meeting the method acceptance criteria of 30%, demonstrate that the method is appropriate for the given matrix. All target analyte field matrix spikes and laboratory matrix spikes met method acceptance criteria with the following exceptions: Location 222R; The FMS recovery for PFOA was 66.1%. The analytical uncertainty for this location was expanded to 34%. PAGE 15 OF 28 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-05-04 Table 11. DAL GW 203L 131001 3M LIMS ID Description ISO13-05-04-001 DAL-GW-203L-0-131001 ISO13-05-04-002 DAL-GW-203L-DB-131001 ISO13-05-04-003 DAL-GW-203L-LS-131001 ISO13-05-04-004 DAL-GW-203L-HS-131001 Average Concentration (ng/mL) %RPD PFOA Concentration (ng/mL) %Recovery 153 NA 152 NA 236 83.0 517 72.7 153 ng/mL 0.65% PFBS Concentration (ng/mL) %Recovery 23.3 NA 24.0 NA 113 89.3 459 86.7 23.7 ng/mL 3.0% PFHS 3M LIMS ID Description ISO13-05-04-001 DAL-GW-203L-0-131001 ISO13-05-04-002 DAL-GW-203L-DB-131001 ISO13-05-04-003 DAL-GW-203L-LS-131001 ISO13-05-04-004 DAL-GW-203L-HS-131001 Average Concentration (ng/mL) %RPD Concentration (ng/mL) %Recovery 147 NA 147 NA 234 87.2 596 90.0 147 ng/mL 0.0% NA = Not Applicable NC= Not Calculated; Spike levels were less than 0.5x the endogenous sample concentration. Samples were diluted 1:100 and analyzed by external standard quantitation. PFOS Concentration (ng/mL) %Recovery 787 NA 794 NA 858 NC 1410 125 791 ng/mL 0.88% Table 12. DAL GW 220R 131003 3M LIMS ID Description ISO13-05-04-005 DAL-GW-220R-0-131003 ISO13-05-04-006 DAL-GW-220R-DB-131003 ISO13-05-04-007 DAL-GW-220R-FMS-131003 Average Concentration (ng/mL) %RPD PFOA Concentration (ng/mL) %Recovery 51.5 NA 47.0 NA 88.8 79.0 49.3 ng/mL 9.1% PFBS Concentration (ng/mL) %Recovery 8.38 NA 7.85 NA 51.2 86.2 8.12 ng/mL 6.5% PFHS 3M LIMS ID Description ISO13-05-04-005 DAL-GW-220R-0-131003 ISO13-05-04-006 DAL-GW-220R-DB-131003 ISO13-05-04-007 DAL-GW-220R-FMS-131003 Average Concentration (ng/mL) %RPD Concentration (ng/mL) %Recovery 41.6 NA 39.0 NA 85.0 89.6 40.3 ng/mL 6.5% NA = Not Applicable Samples were diluted 1:10 and analyzed using external standard quantitation. PFOS Concentration (ng/mL) %Recovery 80.9 NA 76.8 NA 128 98.8 78.9 ng/mL 5.2% PAGE 16 OF 28 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-05-04 Table 13. DAL GW 220L 131003 3M LIMS ID Description ISO13-05-04-008 DAL-GW-220L-0-131003 ISO13-05-04-009 DAL-GW-220L-DB-131003 ISO13-05-04-010 DAL-GW-220L-FMS-131003 Average Concentration (ng/mL) %RPD PFOA Concentration (ng/mL) %Recovery 26.3 NA 26.4 NA 68.2 83.6 26.4 ng/mL 0.38% PFBS Concentration (ng/mL) %Recovery 4.88 NA 5.04 NA 49.5 89.1 4.96 ng/mL 3.2% 3M LIMS ID Description ISO13-05-04-008 DAL-GW-220L-0-131003 ISO13-05-04-009 DAL-GW-220L-DB-131003 ISO13-05-04-010 DAL-GW-220L-FMS-131003 Average Concentration (ng/mL) %RPD PFHS Concentration (ng/mL) %Recovery 17.0 NA 17.5 NA 63.2 92.0 17.3 ng/mL 2.9% PFOS Concentration (ng/mL) %Recovery 49.5 NA 49.5 NA 98.5 98.6 49.5 ng/mL 0.0% NA = Not Applicable Samples were diluted 1:10 and analyzed using external standard quantitation. Table 14. DAL GW 222R 131001 3M LIMS ID Description ISO13-05-04-011 DAL-GW-222R-0-131001 ISO13-05-04-012 DAL-GW-222R-DB-131001 ISO13-05-04-013 DAL-GW-222R-LS-131001 ISO13-05-04-014 DAL-GW-222R-HS-131001 Average Concentration (ng/mL) %RPD PFOA (1) Concentration (ng/mL) %Recovery 317 NA 323 NA NR (3) NR (3) 651 66.1 (4) 320 ng/mL 1.9% (5) PFBS (2) Concentration (ng/mL) %Recovery 44.3 NA 46.6 NA 135 89.5 420 74.6 45.5 ng/mL 5.1% PFHS (2) PFOS (2) 3M LIMS ID Description Concentration (ng/mL) %Recovery Concentration (ng/mL) %Recovery ISO13-05-04-011 DAL-GW-222R-0-131001 298 NA 444 NA ISO13-05-04-012 DAL-GW-222R-DB-131001 317 NA 474 NA ISO13-05-04-013 DAL-GW-222R-LS-131001 401 NC 548 NC ISO13-05-04-014 DAL-GW-222R-HS-131001 707 80.0 861 80.9 Average Concentration (ng/mL) %RPD 308 ng/mL 6.2% 459 ng/mL 6.5% NA = Not Applicable NC = Not Calculated; Spike level was less than 0.5x the endogenous sample concentration. (1) Samples were diluted 1:100 and analyzed using internal standard quantitation. Internal standard was added to the samples during sample preparation. (2) Samples were diluted 1:100 and analyzed using external standard quantitation. (3) NR = Not reportable; sample was not repeated since the spike level was less than 0.5x the sample concentration. (4) FMS did not meet acceptance criteria of 100 30%. (5) The analytical uncertainty was expanded to 34% for PFOA. PAGE 17 OF 28 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-05-04 Table 15. DAL GW 227R 131001 3M LIMS ID Description ISO13-05-04-015 DAL-GW-227R-0-131001 ISO13-05-04-016 DAL-GW-227R-DB-131001 ISO13-05-04-017 DAL-GW-227R-LS-131001 ISO13-05-04-018 DAL-GW-227R-HS-131001 Average Concentration (ng/mL) %RPD PFOA (1) Concentration (ng/mL) %Recovery 241 NA 235 NA NR (3) NR (3) 609 74.1 238 ng/mL 2.5% PFBS (2) Concentration (ng/mL) %Recovery 15.3 NA 14.9 NA 59.7 89.2 443 85.2 15.1 ng/mL 2.6% PFHS (2) PFOS (2) 3M LIMS ID Description ISO13-05-04-015 DAL-GW-227R-0-131001 ISO13-05-04-016 DAL-GW-227R-DB-131001 ISO13-05-04-017 DAL-GW-227R-LS-131001 ISO13-05-04-018 DAL-GW-227R-HS-131001 Average Concentration (ng/mL) %RPD Concentration (ng/mL) %Recovery 58.3 NA 55.8 NA 102 90.0 505 89.8 57.1 ng/mL 4.4% Concentration (ng/mL) %Recovery 660 NA 653 NA 811 NC 1140 97.2 657 ng/mL 1.1% NA = Not Applicable NC = Not Calculated; Spike level was less than 0.5x the endogenous sample concentration. (1) Samples were diluted 1:100 and analyzed using internal standard quantitation. Internal standard was added to the samples during sample preparation. (2) Samples were diluted 1:100 and analyzed using external standard quantitation. (3) NR = Not reportable; sample was not repeated since the spike level was less than 0.5x the sample concentration. PAGE 18 OF 28 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-05-04 Table 16. DAL GW 227L 131001 3M LIMS ID Description ISO13-05-04-019 DAL-GW-227L-0-131001 ISO13-05-04-020 DAL-GW-227L-DB-131001 ISO13-05-04-021 DAL-GW-227L-LS-131001 ISO13-05-04-022 DAL-GW-227L-HS-131001 Average Concentration (ng/mL) %RPD PFOA Concentration (ng/mL) %Recovery 178 NA 172 NA 254 79.0 540 72.9 175 ng/mL 3.4% PFBS Concentration (ng/mL) %Recovery 264 NA 254 NA 338 NC 706 89.0 259 ng/mL 3.9% PFHS 3M LIMS ID Description ISO13-05-04-019 DAL-GW-227L-0-131001 ISO13-05-04-020 DAL-GW-227L-DB-131001 ISO13-05-04-021 DAL-GW-227L-LS-131001 ISO13-05-04-022 DAL-GW-227L-HS-131001 Average Concentration (ng/mL) %RPD Concentration (ng/mL) %Recovery 83.0 NA 81.9 NA 167 84.7 538 91.3 82.5 ng/mL 1.3% NA = Not Applicable NC = Not Calculated; Spike level was less than 0.5x the endogenous sample concentration. Samples were diluted 1:100 and analyzed using external standard quantitation. PFOS Concentration (ng/mL) %Recovery 826 NA 838 NA 905 NC 1310 96.2 832 ng/mL 1.4% Table 17. DAL GW 310R 131002 3M LIMS ID Description ISO13-05-04-023 DAL-GW-310R-0-131002 ISO13-05-04-024 DAL-GW-310R-DB-131002 ISO13-05-04-025 DAL-GW-310R-FMS-131002 Average Concentration (ng/mL) %RPD PFOA Concentration (ng/mL) %Recovery 953 NA 928 NA 1750 80.9 941 ng/mL 2.7% PFBS Concentration (ng/mL) %Recovery 1310 NA 1300 NA 2200 89.0 1310 ng/mL 0.76% PFHS 3M LIMS ID Description ISO13-05-04-023 DAL-GW-310R-0-131002 ISO13-05-04-024 DAL-GW-310R-DB-131002 ISO13-05-04-025 DAL-GW-310R-FMS-131002 Average Concentration (ng/mL) %RPD Concentration (ng/mL) %Recovery 310 NA 304 NA 1230 92.5 307 ng/mL 2.0% NA = Not Applicable Samples were diluted 1:100 and analyzed using external standard quantitation. PFOS Concentration (ng/mL) %Recovery 778 NA 755 NA 1720 95.9 767 ng/mL 3.0% PAGE 19 OF 28 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-05-04 Table 18. DAL GW RW312R 131011 PFOA 3M LIMS ID Description Concentration (ng/mL) %Recovery ISO13-05-04-026 DAL-GW-RW312R-0-131011 ISO13-05-04-027 DAL-GW-RW312R-DB-131011 ISO13-05-04-028 DAL-GW-RW312R-FMS-131011 ISO13-05-04-026; LMS DAL-GW-RW312R-0-LMS Average Concentration (ng/mL) %RPD 6740 NA 6860 NA NR (1) NR (1) 12400 119 6800 ng/mL 1.8% PFBS Concentration (ng/mL) %Recovery 7220 NA 7300 NA NR (1) NR (1) 12600 108 7260 ng/mL 1.1% PFHS PFOS 3M LIMS ID Description Concentration (ng/mL) %Recovery ISO13-05-04-026 DAL-GW-RW312R-0-131011 ISO13-05-04-027 DAL-GW-RW312R-DB-131011 ISO13-05-04-028 DAL-GW-RW312R-FMS-131011 ISO13-05-04-026; LMS DAL-GW-RW312R-0-LMS Average Concentration (ng/mL) %RPD 1320 NA 1280 NA 2260 96.2 NA NA 1300 ng/mL 3.1% Concentration (ng/mL) %Recovery 2850 NA 2860 NA NR (1) NR (1) 8550 124 2860 ng/mL 0.35% NA = Not Applicable Samples were diluted 1:100 and analyzed using external standard quantitation. The injection volume was decreased to produce a dilution factor of 400. (1) NR = Not reportable; sample was not repeated since the spike level was less than 0.5x the sample concentration. Table 19. DAL GW 317L 131002 3M LIMS ID Description ISO13-05-04-029 DAL-GW-317L-0-131002 ISO13-05-04-030 DAL-GW-317L-DB-131002 ISO13-05-04-031 DAL-GW-317L-FMS-131002 Average Concentration (ng/mL) %RPD PFOA Concentration (ng/mL) %Recovery 0.290 NA 0.308 NA 1.18 88.1 0.299 ng/mL 6.0% PFBS Concentration (ng/mL) %Recovery <0.0250 NA <0.0250 NA 0.989 98.9 <0.0250 ng/mL 3M LIMS ID Description ISO13-05-04-029 DAL-GW-317L-0-131002 ISO13-05-04-030 DAL-GW-317L-DB-131002 ISO13-05-04-031 DAL-GW-317L-FMS-131002 Average Concentration (ng/mL) %RPD PFHS Concentration (ng/mL) %Recovery 0.0932 NA 0.104 NA 1.10 100 0.0986 ng/mL 11% PFOS Concentration (ng/mL) %Recovery 0.241 NA 0.245 NA 1.23 98.7 0.243 ng/mL 1.6% NA = Not Applicable Samples were analyzed using internal standard quantitation. Internal standard was added to the samples during sample preparation. PAGE 20 OF 28 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-05-04 Table 20. DAL GW 324L 130927 3M LIMS ID Description ISO13-05-04-032 DAL-GW-324L-0-130927 ISO13-05-04-033 DAL-GW-324L-DB-130927 ISO13-05-04-034 DAL-GW-324L-FMS-130927 Average Concentration (ng/mL) %RPD PFOA Concentration (ng/mL) %Recovery 219 NA 203 NA 363 76.0 211 ng/mL 7.6% PFBS Concentration (ng/mL) %Recovery 74.6 NA 69.7 NA 236 81.9 72.2 ng/mL 6.8% PFHS PFOS 3M LIMS ID Description ISO13-05-04-032 DAL-GW-324L-0-130927 ISO13-05-04-033 DAL-GW-324L-DB-130927 ISO13-05-04-034 DAL-GW-324L-FMS-130927 Average Concentration (ng/mL) %RPD Concentration (ng/mL) %Recovery 55.3 NA 53.3 NA 228 86.9 54.3 ng/mL 3.7% Concentration (ng/mL) %Recovery 78.0 NA 77.7 NA 264 93.5 77.9 ng/mL 0.39% NA = Not Applicable Samples were diluted 1:10 and analyzed using external standard quantitation. Table 21. DAL GW RW327R 131011 3M LIMS ID Description ISO13-05-04-035 DAL-GW-RW327R-0-131011 ISO13-05-04-036 DAL-GW-RW327R-DB-131011 ISO13-05-04-037 DAL-GW-RW327R-LS-131011 ISO13-05-04-038 DAL-GW-RW327R-HS-131011 Average Concentration (ng/mL) %RPD PFOA (1) Concentration (ng/mL) %Recovery 1180 NA 1190 NA NR (3) NR (3) 1910 72.0 1190 ng/mL 0.84% PFBS (2) Concentration (ng/mL) %Recovery 59.9 NA 63.8 NA 150 88.1 943 88.1 61.9 ng/mL 6.3% PFHS (2) PFOS (2) 3M LIMS ID Description ISO13-05-04-035 DAL-GW-RW327R-0-131011 ISO13-05-04-036 DAL-GW-RW327R-DB-131011 ISO13-05-04-037 DAL-GW-RW327R-LS-131011 ISO13-05-04-038 DAL-GW-RW327R-HS-131011 Average Concentration (ng/mL) %RPD Concentration (ng/mL) %Recovery 159 NA 169 NA 257 93.2 1050 88.8 164 ng/mL 6.1% Concentration (ng/mL) %Recovery 617 NA 708 NA 747 NC 1530 87.2 663 ng/mL 14% NA = Not Applicable NC = Not Calculated; Spike level was less than 0.5x the endogenous sample concentration (1) Samples were diluted 1:100 and analyzed using internal standard quantitation. Internal standard was added to the samples during sample preparation. (2) Samples were diluted 1:100 and analyzed using external standard quantitation. (3) NR = Not reportable; sample was not repeated since the spike level was less than 0.5x the sample concentration. PAGE 21 OF 28 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-05-04 Table 22. DAL GW 328R 130927 3M LIMS ID Description ISO13-05-04-039 DAL-GW-328R-0-130927 ISO13-05-04-040 DAL-GW-328R-DB-130927 ISO13-05-04-041 DAL-GW-328R-LS-130927 ISO13-05-04-042 DAL-GW-328R-HS-130927 Average Concentration (ng/mL) %RPD PFOA (1) Concentration (ng/mL) %Recovery 409 NA 397 NA NR (3) NR (3) 787 76.6 403 ng/mL 3.0% PFBS (2) Concentration (ng/mL) %Recovery 33.8 NA 32.5 NA 74.1 81.8 428 78.6 33.2 ng/mL 3.9% PFHS (2) PFOS (2) 3M LIMS ID Description ISO13-05-04-039 DAL-GW-328R-0-130927 ISO13-05-04-040 DAL-GW-328R-DB-130927 ISO13-05-04-041 DAL-GW-328R-LS-130927 ISO13-05-04-042 DAL-GW-328R-HS-130927 Average Concentration (ng/mL) %RPD Concentration (ng/mL) %Recovery 52.4 NA 51.0 NA 94.8 86.4 461 82.0 51.7 ng/mL 2.7% Concentration (ng/mL) %Recovery 274 NA 265 NA 311 NC 693 85.1 270 ng/mL 3.3% NA = Not Applicable NC = Not Calculated; Spike level was less than 0.5x the endogenous sample concentration (1) Samples were diluted 1:10 (0, DB, LS) or 1:100 (HS) and analyzed using internal standard quantitation. Internal standard was added to the samples during sample preparation. (2) Samples were diluted 1:10 (0, DB, LS) or 1:100 (HS) and analyzed using external standard quantitation. (3) NR = Not reportable; sample was not repeated since the spike level was less than 0.5x the sample concentration. PAGE 22 OF 28 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-05-04 Table 23. DAL GW 328L 130927 3M LIMS ID Description ISO13-05-04-043 DAL-GW-328L-0-130927 ISO13-05-04-044 DAL-GW-328L-DB-130927 ISO13-05-04-045 DAL-GW-328L-LS-130927 ISO13-05-04-046 DAL-GW-328L-HS-130927 Average Concentration (ng/mL) %RPD PFOA (1) Concentration (ng/mL) %Recovery 108 NA 109 NA NR (3) NR (3) 207 98.0 109 ng/mL 0.92% PFBS (1) Concentration (ng/mL) %Recovery 45.7 NA 44.9 NA NR (3) NR (3) 143 97.7 45.3 ng/mL 1.8% PFHS (2) PFOS (2) 3M LIMS ID Description ISO13-05-04-043 DAL-GW-328L-0-130927 ISO13-05-04-044 DAL-GW-328L-DB-130927 ISO13-05-04-045 DAL-GW-328L-LS-130927 ISO13-05-04-046 DAL-GW-328L-HS-130927 Average Concentration (ng/mL) %RPD Concentration (ng/mL) %Recovery 17.6 NA 16.1 NA 17.0 NC 92.6 75.9 16.9 ng/mL 8.9% Concentration (ng/mL) %Recovery 1.29 NA 1.18 NA 1.97 73.0 87.0 86.3 1.24 ng/mL 8.9% NA = Not Applicable NC = Not Calculated; Spike level was less than 0.5x the endogenous sample concentration (1) Samples were diluted 1:10 and analyzed using internal standard quantitation. Internal standard was added to the samples during sample preparation. (2) Samples were diluted 1:10 and analyzed using external standard quantitation. (3) NR = Not reportable; sample was not repeated since the spike level was less than 0.5x the sample concentration. PAGE 23 OF 28 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-05-04 Table 24. DAL GW 330R 130927 3M LIMS ID Description ISO13-05-04-047 DAL-GW-330R-0-130927 ISO13-05-04-048 DAL-GW-330R-DB-130927 ISO13-05-04-049 DAL-GW-330R-LS-130927 ISO13-05-04-050 DAL-GW-330R-HS-130927 Average Concentration (ng/mL) %RPD PFOA Concentration (ng/mL) %Recovery 278 NA 281 NA 669 77.6 1130 85.0 280 ng/mL 1.1% PFBS Concentration (ng/mL) %Recovery 1430 NA 1440 NA 1860 NC 2320 88.0 1440 ng/mL 0.69% 3M LIMS ID Description ISO13-05-04-047 DAL-GW-330R-0-130927 ISO13-05-04-048 DAL-GW-330R-DB-130927 ISO13-05-04-049 DAL-GW-330R-LS-130927 ISO13-05-04-050 DAL-GW-330R-HS-130927 Average Concentration (ng/mL) %RPD PFHS Concentration (ng/mL) %Recovery 163 NA 163 NA 613 90.2 1080 91.9 163 ng/mL 0.0% PFOS Concentration (ng/mL) %Recovery 676 NA 688 NA 1160 96.2 1730 105 682 ng/mL 1.8% NA = Not Applicable NC = Not Calculated; Spike level was less than 0.5x the endogenous sample concentration Samples were diluted 1:100 and analyzed using external standard quantitation. Table 25. DAL GW 330L 130927 3M LIMS ID Description ISO13-05-04-051 DAL-GW-330L-0-130927 ISO13-05-04-052 DAL-GW-330L-DB-130927 ISO13-05-04-053 DAL-GW-330L-FMS-130927 ISO13-05-04-051; LMS DAL-GW-330L-0-LMS Average Concentration (ng/mL) %RPD PFOA Concentration (ng/mL) %Recovery 83.9 NA 82.5 NA 481 79.4 NA NA 83.2 ng/mL 1.7% PFBS Concentration (ng/mL) %Recovery 1360 NA 1310 NA NR (1) NR (1) 2350 99.1 1340 ng/mL 3.7% PFHS PFOS 3M LIMS ID Description ISO13-05-04-051 DAL-GW-330L-0-130927 ISO13-05-04-052 DAL-GW-330L-DB-130927 ISO13-05-04-053 DAL-GW-330L-FMS-130927 Average Concentration (ng/mL) %RPD Concentration (ng/mL) %Recovery 462 NA 455 NA 925 93.4 459 ng/mL 1.5% Concentration (ng/mL) %Recovery 181 NA 177 NA 681 101 179 ng/mL 2.2% NA = Not Applicable Samples were diluted 1:00 and analyzed using external standard quantitation. (1) NR = Not reportable; sample was not repeated since the spike level was less than 0.5x the sample concentration. PAGE 24 OF 28 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-05-04 Table 26. DAL GW RW331S 131011 PFOA 3M LIMS ID Description Concentration (ng/mL) %Recovery ISO13-05-04-054 DAL-GW-RW331S-0-131011 ISO13-05-04-055 DAL-GW-RW331S-DB-131011 ISO13-05-04-056 DAL-GW-RW331S-FMS-131011 Average Concentration (ng/mL) %RPD 422 NA 428 NA 1200 77.5 425 ng/mL 1.4% PFBS Concentration (ng/mL) %Recovery 432 NA 427 NA 1270 84.0 430 ng/mL 1.2% PFHS 3M LIMS ID Description Concentration (ng/mL) %Recovery ISO13-05-04-054 DAL-GW-RW331S-0-131011 ISO13-05-04-055 DAL-GW-RW331S-DB-131011 ISO13-05-04-056 DAL-GW-RW331S-FMS-131011 Average Concentration (ng/mL) %RPD 160 NA 161 NA 1040 88.1 161 ng/mL 0.62% NA = Not Applicable Samples were diluted 1:00 and analyzed using external standard quantitation. PFOS Concentration (ng/mL) %Recovery 465 NA 457 NA 1410 95.5 461 ng/mL 1.7% Table 27. DAL GW 335R 131002 3M LIMS ID Description ISO13-05-04-057 DAL-GW-335R-0-131002 ISO13-05-04-058 DAL-GW-335R-DB-131002 ISO13-05-04-059 DAL-GW-335R-FMS-131002 Average Concentration (ng/mL) %RPD PFOA Concentration (ng/mL) %Recovery 4680 NA 4650 NA 9820 103 4670 ng/mL 0.64% PFBS Concentration (ng/mL) %Recovery 1230 NA 1250 NA 6110 97.0 1240 ng/mL 1.6% PFHS 3M LIMS ID Description ISO13-05-04-057 DAL-GW-335R-0-131002 ISO13-05-04-058 DAL-GW-335R-DB-131002 ISO13-05-04-059 DAL-GW-335R-FMS-131002 Average Concentration (ng/mL) %RPD Concentration (ng/mL) %Recovery 1650 NA 1660 NA 6540 97.8 1660 ng/mL 0.60% NA = Not Applicable Samples were diluted 1:100 and analyzed using external standard quantitation. PFOS Concentration (ng/mL) %Recovery 6440 NA 6510 NA 11900 109 6480 ng/mL 1.1% PAGE 25 OF 28 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-05-04 Table 28. DAL GW GRS04 131011 PFOA 3M LIMS ID Description ISO13-05-04-060 DAL-GW-GRS04-0-131011 ISO13-05-04-061 DAL-GW-GRS04-DB-131011 ISO13-05-04-062 DAL-GW-GRS04-FMS-131011 Average Concentration (ng/mL) %RPD Concentration (ng/mL) %Recovery 5530 NA 5410 NA 10800 106 5470 ng/mL 2.2% PFBS Concentration (ng/mL) %Recovery 2830 NA 2730 NA 7940 103 2780 ng/mL 3.6% PFHS 3M LIMS ID Description ISO13-05-04-060 DAL-GW-GRS04-0-131011 ISO13-05-04-061 DAL-GW-GRS04-DB-131011 ISO13-05-04-062 DAL-GW-GRS04-FMS-131011 Average Concentration (ng/mL) %RPD Concentration (ng/mL) %Recovery 9540 NA 9140 NA 15400 121 9340 ng/mL 4.3% NA = Not Applicable Samples were diluted 1:100 and analyzed using external standard quantitation. PFOS Concentration (ng/mL) %Recovery 2690 NA 2940 NA 7720 98.6 2820 ng/mL 8.9% Table 29. Trip Blank 3M LIMS ID ISO13-05-04-063 ISO13-05-04-064 ISO13-05-04-065 ISO13-05-04-066 Description DAL-GW-TRIP01 -0 (1) DAL-GW-TRIP01 -LS (2) DAL-GW-TRI P01-MS (2) DAL-GW-TRI P01-HS (2) PFOA Concentration (ng/mL) <0.0240 0.856 98.2 964 %Recovery NA 85.6 98.2 96.4 PFBS Concentration (ng/mL) <0.0250 0.974 95.3 932 %Recovery NA 97.4 95.3 93.2 PFHS PFOS 3M LIMS ID ISO13-05-04-063 ISO13-05-04-064 ISO13-05-04-065 ISO13-05-04-066 Description DAL-GW-TRI P01-0 (1) DAL-GW-TRI P01-LS (2) DAL-GW-TRI P01-MS (2) DAL-GW-TRI P01-HS (2) Concentration (ng/mL) <0.0400 0.915 98.2 968 %Recovery NA 91.6 98.4 97.0 Concentration (ng/mL) <0.0232 0.894 106 1130 %Recovery NA 89.4 107 114 NA = Not Applicable (1) Samples were analyzed using internal standard quantitation. Internal standard was added to the sample during sample preparation. (2) Samples were diluted 1:10 (LS, MS) or 1:100 (HS) and analyzed using external standard quantitation. PAGE 26 OF 28 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-05-04 Table 30. Rinseate Blank PFOA PFBS PFHS PFOS 3M LIMS ID ISO13-05-04-067 Description DAL-GW-324L-RB-130927 Concentration (ng/mL) <0.0240 Concentration (ng/mL) <0.0250 Concentration (ng/mL) <0.0400 Concentration (ng/mL) <0.0232 Samples were analyzed using internal standard quantitation. Internal standard was added to the sample during sample preparation. 5 Conclusion Laboratory control spikes were used to determine the analytical method accuracy and precision for all analytes. The accuracy and precision were then used to estimate the method uncertainty for the results. Field and laboratory matrix spike recoveries demonstrated that the analytical method was appropriate for the given sample matrix. Method ETS-8-044.1 "Method of Analysis for the Determination of Perfluorinated Compounds in Water by LC/MS/MS; Direct Injection Analysis" was used for analysis. Analytical results are reported in Table 1 and 10-29 of this report. 6 Data / Sample Retention All remaining sample and associated project data (hardcopy and electronic) will be archived according to 3M Environmental Laboratory standard operating procedures. PAGE 27 OF 28 7 Signatures 3M ENVIRONMENTAL LABORATORY REPORT NO. IS013-05-04 William K. Reagen, Ph D., 3M Environmental Technical Director Date The 3M Environmental Laboratory's Quality Assurance Unit has audited the data and report for this project. !/ Quality Assurance Representative U N 3 Date This test report shall not be reproduced except in full, without written approval of the 3M Environmental Laboratory. _