Document b5Bmb3819aybjVqeJ80BgKRXZ
Report No. A2200090001101001 Test Report
Page 1 of 4
Applicant CHANGZHOU XCF POLYMER MATERIALS CO., LTD. Address NO.999 DINGJIAN ROAD, DINGYAN TOWN, CHANGZHOU, 213025 CHINA
The following sample(s) and sample information was/were submitted and identified by/on the behalf of
the client
Sample Name
PTFE White Sewing Thread
Part No.
1200Denier
Sample Received Date
Apr. 14, 2020
Testing Period
Apr. 14, 2020 to Apr. 28, 2020
Test Conducted: As requested by the applicant. For details refer to next page(s).
Tested by
Reviewed by
Approved by
Hill Zheng
Technical Manager
Date
Apr. 28, 2020
No. R187211363
Centre Testing International Group Co.,Ltd.
CTI Building, Xing Dong Community, Xin'an Sub-district, Bao'an District, Shenzhen City, Guangdong Province, P.R. China
Report No. A2200090001101001 Executive Summary:
Test Report
Page 2 of 4
TEST REQUEST Refer to FDA 21CFR 177.1550 Perfluorocarbon resins
- Total extractives - Fluoride extractives
CONCLUSION
PASS PASS
PASS (FAIL) means that the results shown on the report (do not) comply with the required limits.
************* For further details, please refer to the following page(s) *************
Test Report
Report No. A2200090001101001
Refer to FDA 21CFR 177.1550 Perfluorocarbon resins
Total extractives
Test Method: Refer to FDA 21CFR 177.1550
Test Item(s)
Distilled water extractives 50% ethanol extractives N-heptane extractives Ethyl acetate extractives
Result
001 1.0 0.7 1.7 2.1
MDL
0.5 0.5 0.5 0.5
Fluoride extractives
Test Method: Refer to FDA 21CFR 177.1550
Test Item(s)
Fluoride extractives in distilled water Fluoride extractives in 50% ethanol Fluoride extractives in n-heptane Fluoride extractives in Ethyl Acetate
Result 001 N.D.
N.D.
N.D.
N.D.
MDL 0.05 0.05 0.05 0.05
Page 3 of 4
Reference Limit
3.1 3.1 3.1 3.1
Unit
mg/dm mg/dm mg/dm mg/dm
Reference Limit
0.46
Unit mg/dm
0.46
mg/dm
0.46
mg/dm
0.46
mg/dm
Remark: - MDL = Method Detection Limit - N.D. = Not Detected (<MDL)
Sample/Part Description 001 White plastic thread
Note: - The testing data and result(s) in this report is(are) just for scientific research, education, internal quality
control and product development etc.
Report No.
Test Report
A2200090001101001
Photo(s) of the sample(s)
Page 4 of 4
*** End of Report ***
Statement: 1. This report is considered invalid without approved signature, special seal and the seal on the perforation; 2. The sample(s) and sample information was/were provided by the client who should be responsible for the
authenticity which CTI hasn't verified; 3. The result(s) shown in this report refer(s) only to the sample(s) tested; 4. Without written approval of CTI, this report can't be reproduced except in full; 5. In case of any discrepancy between the English version and Chinese version of the testing reports (if
generated), the Chinese version shall prevail.