Document b35najqRX0B1bbo44oxeEbND
CELANESE CHEMICAL COMPANY Chemeel Plant Bishop, Texas
o: Plant OSHA Committee
rom: J. M. Jackson
JMJ 17-73
*J. W. Beasley J, D. Cantrell W. L. Davis
P. A. Turek
August 23, 1973
T. G. Glidden W. E. Harrison H. M. .Tomblinson
Airborne Asbestos Measurement
Airborne concentration of asbestos levels during SEO Celanex 3310 oduction has been determined. Results are below the Threshold Limit Value LV*- 5 fibers/ml >5 in length). Table I.
Monitoring equipment was attached to the operator during handling of asbestos fiber, filler for SEO Celanex 3310 production. Sampling period red the entire.period of handling. Asbestos concentration was less than 5 fibers/ml. ^
From these data and data reported in RLD 23-72, it .is recommended * Celcon airborne asbestos sampling be scheduled during the first and third *tsr of each year. This sampling frequency will be in accordance with the ^pational Safety and Health Act, Section 1910. 93a (Appendix I).
r/bb ^chm<ents:
^*srs.
J. H. Frick K. B. Rollins R. G. Brandt S. W. FretweU E. J. Heinz
,'rru^WrV j. M. Jackson
W. M. Malone P. Roberts L. L. Schweers K. A. Wolf
003997
2 August 23, 1973 References: 1. Threshold Limit Values (TLV) American Conference of Governmental
Industrial Hygienists, 1972. 2. Federal Register, Occupational Safety and Health Administration; Wed.
Oct. 18, 1972; Volume 37, Number 202, Section 1910.93a.
003998
TABLE I
Airborne Asbestos Levels During SEO Celanex 3310 Run
Date 6-18-73 6-19-73 6-20-73 6-21-73
Fibers/ml * >5 in Length
0.0100.030 0.006 0.000
1. Microscopic fiber counting by M.A. Sieminski, Celanese Research Co., Summit, N. J. Ref. MAS 73-118, August 10, 1973.
003999
APPENDIX I Occupational Safety and Health Act Asbestos Regulation Section-1910, 93a
1910,93a Asbestos Sampling Frequency and Patterns
"After initial determinations, samples shall be of such frequency and pattern as to represent with reasonable accuracy the levels of exposure of employees. In no case shall sampling be at 't- intervals greater than 6 months for employees whose exposures to asbestos may reasonably be foreseen to exceed exposure limits. "
i
004000