Document az48VQwyyaMNQwB3ZQr9j6Yy
4
Chapter 1
1945. Guide
~ TheTelationship of Equation 1 expresses-certain "familiar laws approxi- ~
mately true for gases at not too high pressures. Thus, with temperature constant, the volume of a given weight of gets is inversely proportional to its absolute pressure is a statement of Boyle's Law. If denotes the specific volume at absolute pressure pi, then at the same temperature, the specific volume vt at absolute pressure pi is approximately,
: *-()
Also, with pressure constant the volume of a given weight of gas is directly proportional to its absolute temperature is a statement of Charles' Law. If Vi denotes the specific volume at absolute temperature 7\, then at the same pressure, the specific volume Vi at absolute temperature 72 is approxi mately,
-(*)
Absolute Temperature
For the range 0 to 660 C, the standard temperature scale is the Inter- . national Centigrade Scale, namely, the readings of a platinum resistance
thermometer standardized at the ice-point (0 C), the steam-point (100 C) and the sulphur-point (444.60 C). The corresponding Fahrenheit stale t used in scientific work is derived from the International Centigrade Scale by means of the relation, .
t = 1.8 (Int. Cent. Temp.) +32
(3)
Temperatures on the absolute Fahrenheit scale are then obtained by adding 459.70 according to the equation
T = t + 459.70
(4)
Absolute temperatures computed from Equations 3 and 4 are. practically identical with the fundamental thermodynamic temperatures to which, the zero-pressure values of the product pv for gases are proportional in accordance with Equation 2.
Specific Enthalpy
Most air conditioning processes are of the steady-flow type. In steady flow the energy convected with the fluid crossing a given section is the sum of (a) kinetic energy due to velocity, (b) gravitational energy due to elevation, (c) enthalpy due to the condition of temperature, pressure and composition at a given section. It is clear, therefore, that in order to apply the Law of Conservation of Energy to steady-flow processes, information regarding the enthalpy is needed.
Recent developments in quantum mechanics have made it possible to
calculate the zero-pressure specific enthalpy of a gas from spectroscopic
measurements, and with a degree of accuracy exceeding that with which
this property can be inferred from direct calorimetric measurements.
Available data for each gas listed in Table 1 have been assembled and
critically examined; and from them have been calculated best values
for the specific enthalpy of dry air at zero pressure. These are listed in
Table 3. The unit of energy is the Btu which is related to the foot
pound as follows;
1 Btu = 778.18 ft-lb1
(5)
iThis conversion.factor is not exact by definition, but involves an experimental determination of the relation between the absolute and the standard electrical units of energy. The value 1 int. joule = 1.00019 abs. joule, recommended by Osborne, Stimson and Ginnings IS) was used.
Thermodynamics of Air and Water Mixtures
_________ _Tablb_3.__Specific_Enthaley of. Dry_Air at.Zero-Pressure*
Temp
F
t
Specific Enthalpy
Btu per Lb
Mean Specific
Heat
K]o
-96 -64 -32
0
-22.839 -15.186
-7.529 +0.131
0.2393
0.2393 0.2394 0.2394
Temp
F
l
Specific Enthalpy Btu per Lb
Mean Specific
tenHeat
32 ,7.796 0.2395 64 15.466 0.2396 96 23.145 0.2397
128 30.831 0.2398
Temp
F
t
Specific Enthalpy Btu per Lb
Mean
Specific
tenHeat
160 192 224 .
256
38.529
46.238 53.962
61.702
0.2400 0.2401
0.2403 0.2405
Prepared by. John A. Goff from published .data computed from spectroscopic measurements.
In Table 3 are also listed values of mean zero-pressure specific heat for
the range 0 to t F. This is simply the increase of specific enthalpy from
0 to t F,. divided by the increase of temperature or, with 0 F as the
reference point, by the temperature itself. The numerical values indicate that a rounded figure of 0.24 Btu per pound can be used in ordinary calculations.
Applying well known identical relations of thermodynamics to Equation
2, the following expression for specific enthalpy, valid at not too high pressures, is obtained
* = A + [r*<i(^]f>
(6)
where h0 denotes specific enthalpy at zero pressure. This equation emphasizes that the effect of pressure on specific enthalpy is not so much due to the second virial coefficient A itself as to its variation with tempera ture. In other words, the pressure effect may be much more important than the corresponding effect on specific volume. Values of the specific enthalpy of dry air at standard atmospheric pressure (29.921 in. Hg) as computed from Equation 6 are given in Table 4.
Reference Point. It is desired to give some prominence to the choice of reference point. As energy, and therefore enthalpy, is purely relative, any convenient state can be selected at which to assign the value zero to
specific enthalpy. The state chosen is OF, 29.921 in. Hg. Perhaps the only really valid, argument for this particular choice is that, for ordinary calculations at, or near, atmospheric pressure, a very simple equation / can be used, namely,
fe = 0.24/
(7)
WATER VAPOR
Saturation Pressure. It is common knowledge that a substance like water can exist in at least three distinct phases, solid (ordinary ice), liquid and vapor; and that under certain conditions two or more phases
can co-exist in stable equilibrium. For example, steam having a quality of
Table 4. Specific Enthalpy op Dry Air3 at 29.921 In. Hg
Temp
F
t
Specific
Enthalpy Btu per Lb
Aa
Specific I
tenHeat
Temp
F
i
Specific
Specific
tenEnthalpy
Btu per Lb Aa
Heat
-96 --64
--32
0
-23.035
-- 15.356 -7.678 0.000
0.2399 |
0.2399 1 0.2399 0.2400
32 64 96
128
7.680 15.363
23.053 30.749
0.2400 0.2400
0.2401 0.2402
Prepared by John A. GoS.
Temp
F /
Specific Enthalpy Btu per Lb
' Aa
Specific
tenHeat
160 38.454 0.2403 192 46.172 0.2405 224 53.903 0.2406 256 61.649 0.2408