/( // y c ~' - 1.
COST OF RAPID PUASE-OUT - ALL CHLORINATED BIPHENYLS EXCEPT DIELECTRICS
1970
LOSS IN SALES LOSS IN GROSS PROFIT
-
$ 5.4 M $ 2.6 ii
IN ADDITION COGS WOULD INCREASE GIVING TOTAL LOSS IN GROSS PROFIT OF - $2.75 M.
LOSS IN SALES
- $ 12 M
TOTAL LOSS IN GROSS PROFIT - $ 6.1 M
PLUS POSSIBLE WRITE-OFF OF SOME $ 2.6 M KRUMMRIC1I AROCLCR FACILITIES.
03403'*
HONS
2
OBJECTIVE
TO MAINTAIN A PROFITABLE BUSINESS SERVING THE NEEDS OF FUNCTIONAL FLUIDS USERS AND THE CARBONLESS DUPLICATING PAPER INDUSTRY WHILST MINIMIZING THE ESCAPE OF NON-BIODEGRADABLE BIPHENYLS INTO THE ENVIRONMENT.
> '
hons 034035
3
ACTION TO ACHIEVE OBJECTIVES
1) MARKET NON-BIODEGRADABLE CHLORINATED BIPHENYLS ONLY FOR CLOSED SYSTEM APPLICATIONS WHERE CONTROL IS POSSIBLE.
2) PHASE OUT OF ALL NON-CONTROLLABLE APPLICATIONS REPLACING WITH BIODEGRADABLE CHLORINATED BIPHENYLS OR OTHER SATISFACTORY PRODUCTS.
03*> 03"
THE
CLOSED
LOOP
4.
PCB's PRODUCTION
\ ? PvH 9 UdHOEi
>
INCINERATE
V
ADSORPTION FROM
AIR & WATER
A
BIODEGRADATION
MQNS 0 3 4 0 3 7
5
DO WE HAVE THE CAPABILITY TO CLOSE THE LOOP ?
HONS 03AO38
6
biodegradation
1) GOOD PROGRESS AT BOTH RUABON AND ST. LOUIS.
2) LOWER CHLORINATED ISOMERS RESPONDING WELL, BUT 5 & 6 CHLORINE ISOMERS EITHER NOT RESPONDING OR VERY SLOW.
3) CRITICAL PRODUCT IS 1242, CONTAINS SOME 50 ISOMERS
-- GOOD RESPONSE ON 2, 3, & SOME 4 CHLORINE
ISOMERS.
i
4) WORK IN HAND ON FRACTIONATED 1242 GOOD PROCRESS
TO DATE.
1
HONS 034039
FIGURE 2
FIGORS 3
MONS 0 3 4 0 4 1
FIGURE 1 Fractionated 1130
Aroclor 1242B (Fractionated 1142)
Aroclor 1242
HONS 034042
ri
&
REPLACEMENT
PRODUCTS
7.
1) 1242B SHOWS GOOD PROPERTIES AS CAPACITOR DIELECTRIC NCM MAKING 500 GALS. AT DAYTON FOR CUSTOMER TRIALS. ALSO WORKING ON 1230B.
2) GOOD PROGRESS ON PHOSPHATE ESTER REPLACEMENTS FOR HYDRAULIC FLUID APPLICATIONS. -- TCP -- CDP -- TSP -- NONYL PHENYL/CUMYL PHENYL DIPHENYL PHOSPHATE.
3) HEAT TRANSFER FLUIDS -- USING MAINLY ESTABLISHED PRODUCTS, E.G. HB-40 -- EXAMINING POSSIBLE ENTRY INTO DIPHENYL OXIDE PRODUCTION EITHER OWN PROCESS OR LICENSING.
HONS 034043
8
TOXICITY 1) NO CHANC-E SINCE EAST REPORT - HAVE DISCUSSED RESULTS
WITH DR. BURGER, EXECUTIVE OFFICE OF THE PRESIDENT. 2) WE HAVE ANALYZED AROCLORS 1248 AND 1254 FOR OCTOCHLORO
D1BENZO p-DIOXIN -- NONE FOUND. 3) CENTRAL INSTITUTE FOR NUTRITION AND FOOD RESEARCH,
ZEIST, HOLLAND -- EXAMINED BAYER,PRODELAC AND MONSANTO CHLORINATED BIPHENYLS FOR DIBENZO FURANS -- NONE FOUND IN MONSANTO MATERIAL.
hONS 034044
10
INCINERATION
1) SUCCESSFUL TRIAL AT JOHN ZINC CO., TULSA. 1242, 1260, 1254 DESTROYED AT 2000 F.i-- OFF GAS HC1. ENGINEERING WORK NOW IN HAND TO BUILD SUITABLE INCINERATOR. ESTIMATED COST $250,000 M.
2) IOTEND TO CARRY OUT FURTHER TRIALS ON STILL BOTTOMS.
3) INCINERATOR PROBABLY LOCATED AT KRUMMRICH.
MONS 034045
11
HONS 0 3 4 0 4 6
ANNISTON
S lbs./day
KRL'MMRICH
200 lbs./day
NEWPORT - 0.5 lbs.
12
CLOSING
THE
LOOP
FOR
INDIVIDUAL
BUSINESSES.
HONS 034047
13.
TRANSFORMER & CAPACITOR DIELECTRICS
1) RESPONSIBLE INDUSTRIES USING 1254 AND 1242. 2) FIRE RESISTANCE EXTREMELY IMPORTANT.
'i 3) COLLECTION AND RETURN OF SPENT AND ARCED FLUID. 4) REGENERATION AND RECYCLE. 5) TRIALS PLANNED FOR 1242B AND 1230B IF SATISFACTORY.
\I i 6) LABELLING of askarel transformers!
honS
034048
14
HEAT TRANSFER FLUIDS
1) EDUCATION OF USERS WHERE FIRE RESISTANCE IS OBLIGATORY -- MAJOR INDUSTRIAL CORPORATIONS;-- E.G. GOODYEAR AND CHEMICAL COMPANIES.
2) PHASE OUT OF ALL FOOD APPLICATIONS -- LETTERS WILL BE SENT OUT MAY 15th -- NO SALES AFTER AUGUST 15th -- WILL COLLECT AND DESTROY OLD FLUID.
3) INSTITUTION OF REGULAR COLLECTION REGENERATION OR INCINERATION SERVICE.
4) PHASING IN NEW PRODUCTS WHERE CONTROL NOT POSSIBLE.
HONS 034049
15
HYDRAULIC
FLUIDS
1) RECOGNIZE THAT CONTROL OF SPILLAGE AND PUMP LEAKAGE MAKES THE USE OF NON-BIODEGRADABLE CHLORINATED
. BIPHENYLS UNDESIRABLE.
2) ALREADY REFORMULATED PYDRAUL 625,, ACWG, 280 and F9 -- REPLACEMENT COMPLETE BY AUGUST. 1
3) OTHER PRODUCTS IN INTERIM STAGES (E.G. PYDRAUL AC FORMULATION ON COMPRESSOR TEST AT JFQ).
4) AIM TO COMPLETE 907. PHASE-OUT BY DECEMBER, 1970.
034050 HOMS
16
N. C. R,
1) U.K. HAS APPROVED HB-40, NOW PLACED REGULAR
ORDERS -- EXPECT COMPLETE PHASE-OUT BY
1st JULY.
j
>
2) U.S. RUNNING TRIALS ON M.I.B.P., EXPECT DECISION 22nd MAY -- PRELIMINARY INTERIUH PRODUCTION OF 40 M POUNDS PER MONTH TARGETED FOR 30th AUGUST -- PLANNING FULL SCALE PLANT 10 M LBS. PER ANNUM ON STREAM END JANUARY 1971 -- ESTIMATED NFC $1 - 1.2 M.
03405V MOWS
PLASTICIZER 6 MISCELLANEOUS APPLICATIONS
1) DISTRIBUTORS ALREADY ADVISED NO MORE SALES AFTER 30th AUGUST. (200 CUSTOMERS)
2) LETTERS TO 661 CUSTOMERS WILL BE SENT OUT 27th MAY ADVISING NO MORE SALES AFTER 30th AUGUST -- DISPOSAL INSTRUCTIONS WILL BE;GIVEN.
3) IN CONTACT WITH U.S.D.A. THROUGH AG DIVISION ON SILO PAINT PROBLEM.
6) BY 30th AUGUST ALL BUSINESS IN THIS AREA WILL BE
PHASED OUT.
i
034052 HONS
F t E S E HI
PLAN
1) TERMINATE SALES OF ALL NON-BIODEGRADABLE CHLORINATED BIPHENYLS TO NON-CONTROLLABLE END USES.
COMPLETE - AUGUST 30th, 1970. I I
2) DISCONTINUE SALE OF AROCLOR 1242; TO NCR AND REPLACE WITH 1IB-40 IN U.K., AND MIBP IN U.S.A. I COMPLETE - U.K. -* JULY 1st, 1970 COMPLETE - U.S. -- JANUARY 30th, 1971
3) CLOSE THE LOOP ON HEAT TRANSFER APPLICATIONS WHERE F/R IS VITAL AND REPLACE WITH ALTERNATES IN OTHER CASES.
COMPLETE - DECEMBER 30th, 1970
HONS 034053
4) REPLACE ALL NON-BIODEGRADABLE CHLORINATED BIPHENYLS
IN HYDRAULIC APPLICATIONS.
'
COMPLETE 20% - AUGUST 1st, 1970 " 40% - NOVEMBER 1st, 1970 " 100% - DECEMBER 30th, 1970
5) CLOSE THE LOOP ON ALL NON-BIODEGRADABLE CHLORINATED BIPHENYLS IN TRANSFORMER APPLICATIONS.
COMPLETE - AUGUST, 1st, 1970
>
6) CLOSE THE LOOP ON CAPACITORS AS FAR AS POSSIBLE AND REPLACE 1242 WITH 1242B.
COMPLETE - DECEMBER 31st, 1970
HONS 034054
myt capital rgsag
i!3-40 pxpamsiox - ahmistox sa.ntov.'am s refixixo - axxistox >13-40 CAPACITY - Mr.-.'I'CAT ATOP CAPACITY - AXXISTOX ?
? 275,000 S ~ 5u,C 30 ? 1,000,003 $ 1,200,000
Cl'MYL/XOXYL PKEXYL OIPHEXYL PHOSPHITE JFQ
IXCIXESATCR/RECLir-lIXC PQ1
TOTAL XT.-.' PIXEO CAPIT.
575,000 2 S3,COO $ 3,535,030
03^055 kqns
From /At dttkof HOWARD BERGEN
ynhi
F4>* ^, f/J^7/
HONS 034056
&
1971
SAIL'S C. ?. X.v.A.7. cscss ixvss XT
3.0.1.
$ 22.0.X $ 8.5 X $ 2.9 X S 25.4 M
11.5%
.
$ 20.0 $ S. 0 $ 2.7 $ 29.0
9.5%
J
HONS 034057