Document axb1RjdOJpoReBm456LNOgmb

DOW CHEMICAL U.S.A. INDUSTRIAL HYGIENE 1986 First Half Bi-Annual Asbestos Survey in the Cell Service, Chlor-alkali II, and Chlorine Plants IQU1SIANA CUViftiO*U P. O. BOX ISO MINE. LOUISIANA 70706-0160 604 360-6000 CRI NO. FII E NO LAD-IH-86.02 DATE September 12, 1986 AUTHOR Jackie Paul CHECKED / DATE ___________________ SUMMARY Sixty-four (6^) samples were collected during the first half, 1986 asbestos survey. The survey results indicated no overexposures to asbestos due to the appropriate pro tective equipment. Twelve (12) area samples were collected. The range was from < 0.01 to 0.06 fibers/cc > 5 microns in length. The high end of the range was taken on the anode line station at Cell Service. Fifty-two (52) samples were personnel samples with the range being from < 0.01 to 3.08 fibers/cc > 5 microns in length. The highest potential personnel exposure was collected during the hand brushing of copper on the cathodes at Cell Service. Respiratory protection was being worn during the job. This Job procedure has been changed resulting in lower levels of asbestos. Prior to May, 1986, brushing was done on dry cathodes using a brush. This job is now performed on wet cathodes using cloth. Survey results should be compared to the OSHA Permissible Exposure Limits. Limits: 8-hour TWA = 2.0 fibers/cc > 5 microns in length Ceiling Limit = 10.0 fibers/cc > 5 microns in length DISTRIBUTION LOUISIANA DIVISION *R. W. Gallant - 2306 *H. M. Bell - 4701 Dr . M. Currier - 2303 R. Peebles - 5601 E. Bahry - 5601 c. Brannan - 2601 H. Causey - 2601 E. Myer - 3601 *n. W. Gaska - 3701 * K. Mitchell - 3701 T. Austin - 3601 MIDLAND *L. W. Rampy - 1803 *M. Swank - 1803 E. LeBeau - 1803 *G. Engdahl - 1803 *R. Olsen - 1803 *A. Schaffer - 1803 *S. Gorgacz - 474 OTHER *F. D. Axe - Pittsburg *Gary Meier - Strongsville *A. Pollock - Sarnia *D. E. Crager - Freeport *H. Hollis - Texas *R. R. Langner - Houston Dow Center *SUMMARY ONLY AN OPERATING UNIT OF THE DOW CHEMICAL COMPANY Introduction The required asbestos In air monitoring for the first half of 1986 has been completed. The survey serves to help protect the employees against over exposure, pinpoint problem areas and fulfill the requirements of the Federal Occupational Safety and Health Act. Discussion In addition to everyday safety equipment, operators are required to wear disposable paper suits or work .uniforms laundered on-site, rubber gloves and proper dust respirators when handling or working with friable asbestos. The safe procedure for handling asbestos should be discussed with each new employee before entering the work area and reviewed annually with the experienced operators as part of the ongoing Industrial Hygiene Education Program. Sampling Method - Personnel samples are collected from the operators' breathing zone with a mixed cellulose ester membrane filter (25 mm diameter; 0.8 micron pore size) mounted on an open-face filter holder and attached to the operators' lapels. These cassettes are connected to moni toring pumps calibrated with a soap bubble meter to operate at a rate of 1.5 to 2.0 liters per minute. Analytical - The asbestos samples are analyzed using the NIOSH-Approved Method, 7^00 A. Results (See Attachment) The range of the area samples was from <0.01 to 0.06 fibers/cc > 5 microns in length. The high end of the range was taken on the anode line station at Cell Service. The average results for area samples was < 0.02 fibers/cc >5 microns in length. The range of the personnel samples was < 0.01 to 3.08 fibers/cc >5 microns in length. The highest potential personnel exposure was collected during the hand brushing of copper on the cathodes at Cell Service. Respiratory protection was being worn during the Job, This job procedure has been changed resulting in lower levels of asbestos. Prior to May, 1986, brushing was done on dry cathodes using a brush. This job is now performed on wet cathodes using cloth. The average results for personnel samples was < 0.17 fibers/cc > 5 microns in length. DO 08^06/ CONFIDENTIAL -3Conclusions The hazardous nature of asbestos necessitates housekeeping and safe operating procedures remain the most important considerations for an abate ment program. This must be a daily, Job-by-Job program to be successful and to offer the greatest protection to the employee. The Cell Service, Chlor-Alkali II and Chlorine plants employees must be informed of this survey's results and the consequences of exposure to toxic amounts of asbestos reviewed. (See Attachment.) JP :sb 9/86 IH-2 DO 08P058 CONFIDENTIAL CELL SERVICE PLANT ATTACHMENT 1 DATE SAMPLE # 2/27/86 04983 2/28/86 04985 3/3/86 04986 3/4/86 04987 3/5/86 04988 3/5/86 04989 3/21/86 04992 SAMPLE DESCRIPTION DURATION (MIN) Personnel - Laborer (433-52-8881) hand brushing copper on cathode to remove asbestos 435 Personnel - Laborer (435-58-7850) hooking up at drawing area, load and unloading oven, 1 hour debag ging by hand, 1 hour mixing pulp. 490 Personnel - Laborer (435-30-7152) hand brushing copper on cathodes to remove asbestos. 480 Personnel - Laborer (436-56-6612) hooking up cathodes in drawing area, debagging top floor 1/2 hour, dry asbestos mix 1 hour, loading & unloading oven 1V2 hours. 480 Personnel - Laborer (433-52-8881) hand brushing copper on cathodes to remove asbestos. 490 Personnel - SOT (432978) drawing cathodes. 442 Personnel - Laborer (439-76-6187) washing cathodes, working by P-505 pump. 465 VOLUME (1) 870.00 FIBERS/ <5 MICRONS IN LENGTH 3.08 960.00 0. 19 960.00 0.01 960.00 0.35 980.00 0.22 884.000 0.04 906.750 0.15 DO 082059 CONFIDENTIAL CELL SERVICE PLANT ATTACHMENT 1 (continued) DATE 3/24/86 SAMPLE # 04995 SAMPLE DESCRIPTION DURATION (MIN) Personnel - Laborer (436-56-7476) hand brushing copper on cathodes. 390 VOLUME (1) FIBERS/ <5 MICRONS IN LENGTH 790.000 0. 10 3/11/86 04991 Personnel - SOT (433708) hook-up at drawing vat, changed filter on vacuum at comp., assembled cathodes. 470 940.000 0.03 4/23/86 07125 Personnel - Laborer (433-52-8881) brushing and shaping copper, dropping in cathodes. 435 870.000 0.05 Comment: Based on the above results of February 27 - April 23, 1986, the proce dures for cleaning copper on cathodes was changed. Brushing with wire brush was replaced by wiping with wet cloth to reduce employee exposure. Subsequent samples shown below confirm the reduction in fiber exposutes. 5/8/86 07128 Area - Cathode dropin station. 445 890.000 <0.01 5/12/86 07131 Area - 0V501 loading 460 wet and unloading cathodes dry from oven. 920.000 <0.01 5/13/86 07129 Personnel - SOT (432978) drawing cathodes, spraying mobilaroma oil on cathodes during this time also. 450 900.000 <0.01 5/13/86 07130 Personnel - Laborer 460 (435-58-7850) hooking up cathode, loading & unloading oven, dumping asbestos in storage room 920.000 0.03 5/15/86 07132 Personnel - Laborer (434-52-0947) hooking up cathodes, worked debagger room. 475 950.000 0.01 DO OB'<ObU CONFIDENTIAL CELL SERVICE PLANT ATTACHMENT 1 (continued) DATE 5/15/86 SAMPLE # 07133 5/21/86 07134 5/30/86 07135 5/30/86 07136 5/30/86 07137 6/2/86 07138 6/2/86 6/2/86 07139 07140 6/3/86 07142 SAMPLE DESCRIPTION DURATION (MIN) Personnel - Laborer (1)34-32-8857) shaping copper on cathodes, working in drawing area. 460 Area - Cell assembly, dropping in cathodes. 490 Area - Copper shaping area. 420 Personnel - Laborer (439-76-6187) washing cathodes and running drum filter. 390 Personnel - Laborer (433-48-0668) brushing copper on cathodes. 390 Personnel - Laborer 460 (436-56-6612) hooking up cathodes, dumping dry asbestos in storage room, loading and unloading oven. Area - Cathode washer area. 460 Personnel - Laborer (433-52-8881) dropping diaphragms in cells and buckling down. 470 Area - Copper brushing area. 430 VOLUME (1) 900.000 FIBERS/ <5 MICRONS IN LENGTH <0.01 980.000 <0.01 840.000 <0.01 741.000 0.02 741.000 <0.01 874.000 0.01 874.000 916.500 0.01 0.01 858.000 <0.01 DO 082061 CONFIDENTIAL CELL SERVICE PLANT ATTACHMENT 1 (continued) DATE 6/5/86 SAMPLE # 07m 6/5/86 06465 6/17/86 06466 6/17/86 07145 6/17/86 07146 6/18/86 07147 6/18/86 07148 6/18/86 07149 6/18/86 07150 6/23/86 07151 SAMPLE DESCRIPTION DURATION (MIN) Personnel - Laborer (436-50-8990) dropping diaphragms in cells and buckling down. 455 Area - Copper brushing 420 area. Personnel - Laborer (439-76-6187) washing cathodes. 390 Area - Copper brushing 435 area. Area - Cathode washer area. 390 Personnel - Laborer (436-56-6612) debag ging asbestos. 30 Personnel - Laborer (435-58-7850) mixing pulp in asbestos storage room. 120 Personnel - Laborer (435-58-7850) hooking up cathodes, load and unload oven, dumping asbestos in D-509. 480 Personnel - Laborer (433-19-8999) brushing and shaping copper on cathodes. 450 Personnel - Laborer (436-56-6612) hooking up cathodes, dumping asbestos in debagger room. 430 VOLUME (1) 887.250 FIBERS/ <5 MICRONS IN LENGTH <0.01 798.000 741.000 <0.01 0.06 826.500 741.000 60.000 0.01 0.03 0.02 240.000 2.24 888.000 0.03 877.50 0.02 838.500 0.02 D0 082062 CONFIDENTIAL CELL SERVICE PLANT ATTACHMENT 1 (continued) DATE 6/23/86 6/23/86 SAMPLE # 07152 07153 6/24/86 07154 6/24/86 07155 7/25/86 07156 6/30/86 07158 6/30/86 07160 SAMPLE DESCRIPTION DURATION (MIN) Area - Cathode washer 445 Area - Oven area OV-501 445 Personnel - SOT (433708) mixing pulp for pulp tank 3F700 and 7-M. 60 Area - Anode line station 5-7 445 Personnel - SOT (433708) mixing pulp in asbestos storage room 7M and 3F700. 275 Personnel - O.S. (430867) turnaround trailer skin grounding f working on P501A & B, P522A, GT502, and 501A,B. 490 Personnel - O.S. (432917) performed check inspection and stock room duties. 485 VOLUME (1) 867.750 778.75 FIBERS/ <5 MICRONS IN LENGTH 0.03 0.01 120.000 0.94 887.25 563-75 0.06 0.86 1016.750 0.01 945.750 0.03 Proper protective equipment worn. JP:sb 9/15/86 IH-2 DO 08'20fcJ CONFIDENTIAL CA II PLANT ATTACHMENT 1 (Continued) DATE 6/9/86 SAMPLE # 06956 6/11/86 06954 6/16/86 06958 6/16/86 06959 6/17/86 06962 6/23/86 06963 6/23/86 06964 6/24/86 06965 6/24/86 06966 6/24/86 06967 SAMPLE DESCRIPTION DURATION (MIN) Personnel - O.T. (434350) pulping cells. 30 Personnel - O.T. (433856) filled wagon and pulped cells. 66 Personnel - O.T. (434350) pulping cells. 171 Personnel - O.T. (433856) filled wagon and pulped cells. 135 Personnel - O.T. (434350) pulping cells. 25 Personnel - O.T. (433856) filled wagon and pulped cells. 122 Personnel - O.T. (434350) pulping cells. 90 Personnel - O.T. (433856) pulping cells. 72 Personnel - O.T. (433856) pulping cells. 72 Personnel - O.T. 435 (433856) general cell crew duties and pulped VOLUME (1) 57.000 FIBERS/ <5 MICRONS IN LENGTH 0.02 118.800 0.03 290.700 0.02 226.100 <0.01 42.500 0.02 192.150 0.01 189.000 0.03 126.000 0.03 151.200 <0.01 848.250 <0.01 DO 082064 CONFIDFNTTAL CA II PLANT ATTACHMENT 1 (Continued) DATE 6/30/86 SAMPLE # 06968 SAMPLE DESCRIPTION DURATION (MIN) Personnel - O.T. 1150 (^3^350) general cell crew duties and pulped. VOLUME (1) 765.000 FIBERS/ <5 MICRONS IN LENGTH 0.03 DO 08?065 CONFIDENTIAL CHLORINE PLANT ATTACHMENT 1 (Continued) DATE 1/14/86 SAMPLE # 07002 5/13/86 07006 5/14/86 07009 5/14/86 07012 5/14/86 07013 5/29/86 07019 5/29/86 07020 5/29/86 07021 5/29/86 07022 5/30/86 07026 SAMPLE DESCRIPTION Personnel - S.O.T. (433590) pulping cells. Personnel - O.T. (278570) pulping cells. Personnel - S.O.T. (433825) pulping cells. Personnel - O.T. (278570) pulping cells. Personnel - O.T. (278570) pulping cells. Personnel - O.T. (278570) pulping cells. Personnel - S.O.T. (433311) pulping cells. Personnel - S.O.T. pulping cells. Personnel - O.T. (278570) pulping cells. Personnel - S.O.T. (433588) pulping cells. DURATION (MIN) 75 48 48 60 70 25 48 25 48 55 VOLUME (1) 150.000 FIBERS/ <5 MICRONS IN LENGTH 0.03 960.000 0.01 960.000 0.02 120.000 0.02 140.000 0.01 50.000 0.07 96.000 0.04 50.000 96.000 0.02 0.04 110.000 0.04 do oa^ofofo CONFIDFNTTAl CHLORINE PLANT ATTACHMENT 1 (Continued) DATE 5/14/86 SAMPLE * 0701 ^4 5/16/86 07017 SAMPLE DESCRIPTION Personnel - S.O.T. (433825) pulping cells. Personnel - S.O.T. (433311) pulping cells. DURATION (MIN) 65 41 VOLUME (1) 130.000 FIBERS/ <5 MICRONS IN LENGTH <0.01 82.0000 0.01 PROPER PROTECTIVE EQUIPMENT WORN. 00 082067 identic. CONF