Document aZd4x1K7NmqGje4vaQ6E39vY

222, CHAPTER 10 1957 Guide of the permeance, and correspondingly, the over-all vapor resistance of an assembly (like a wall) of materials in series is the sum of the resistances of its component parts. The over-all permeance of the assembly may be found from the permeances of the individual components3,4 in a manner paralleling that used in calculating the over-all coefficient of thermal con ductivity from the individual conductances: M, = 7-L + -L. \M,^ M, M, 4.) (7) This simple theory for vapor flow, as in the case of the corresponding plaster mineral wool sheathing ON LATH BETWEEN STUDS PAPER B SIDING X Fig. 2. Temperatures and Vapor Pressures under Vapor Flow Conditions in the Insulated Frame Wall of Example 1. simple heat-flow theory, assumes conditions of unidirectional, steady-,, state flow. Useful calculations can be made for an assembly or sub assembly for which the inflow and outflow of vapor are equal (a condition at which no condensation occurs) if a permeance applicable to actual conditions can be assigned to each component part. Over-all permeances} vapor pressures and vapor flow can be calculated, and in conjunction} with thermal calculations, relative humidities can be determined, and imminence of condensation predicted. (See Example 1, and Fig. 2. See" also Chapter 13, Cooling Load, for use of vapor-flow calculations.) 'v d Example 1: A wood frame wall is exposed to inside conditions 70 F. and 50 relative humidity (0.37 in. Hg vapor pressure) and outside conditions 0 F. and percent relative humidity (0.03 in. Hg vapor pressure). The wall consists of plaster on gypsum lath on the inside over 2 x 4 in. studs, mineral wool fill bet-ww,! Moisture in Building Construction 223 condensation. --a, t--t--., ,,aau Biuuig. unecK tor possible To simplify the example, consider the paint, plaster and lath as a angle element having a permeance M = 1.0 perms and a thermal conductance C 2.4, and the exterior sheathing, paper, siding and paint as another single element for which M 2.0 perms and C = 0.50. From Table 1 the value for the permeability of mineral wool fwilol oml,aky =be0f.2o7u.nd as i* = 116 perm-inches. The thermal conductivity for mineral Solution: In this particular wall, insulated, and with moderate warm-aide relative humidities, condensation is unlikely to occur until the sheathing is reached. Tocheck directly for condensation on the warm side of the exterior sheathing (designated as plane X -- X in Fig. 2 for convenient reference) proceed as follows: Calculate according to the method of Chapter 9 the temperature at plane X -- X. This is found to be 9 F. The saturation vapor pressure at this temperature is 0.08 in. Hg. If condensation is imminent or occurring at X -- X, the vapor pressure there will be 0.06 in. Hg. Calculate the permeance for the portion of the wall from the warm ride to X -- X, and the vapor flow rate to X - X as follows: Permeance of wall to X - X = , 3.625 = 0.97 perms. 1.0 + 116 Vapor presssure drop to X -- X -- 0.37 -- 0.06 = 0.31 in. Hg. Vapor flow to X -- X ** 0.97 X 0.31 = 0.30 grains per (sq ft) (hr). as Cfoalllocwulsa:te the vapor flow rate from X -- X to outride Permeance of wall from X -- X to outside -- 2.0 perms. Vapor pressure drop from X -- X to outride =* 0.06 -- 0.03 - 0.03 in. Hg. Vapor flow rate to outside -- 2.0 X 0.03 = 0.06 grains per (sq ft) (hr). It is apparent that continuity of vapor flow is not possible, since at the highest vapor pressure at X -- X permitted by the temperature, there is indicated a greater flow to plane X -- X than from it to outride. Condensation is indicated at a rate of 0.30 -- 0.06 = 0.24 grains per (sq ft) (hr). Whether this condensation rate will be serious must still be decided, Since it might readily be absorbed by the sheathing during the condensation period without excessive wetting. When the temperature at X -- X is below freezing, as in this case, the condensation will be in tne form of frost which may accumulate until re leased over a short period upon a rise in outside temperature. Condensation will be reduced or avoided if the permeance of the warm side of the wall can be reduced so that the flow to X -- X is limited to 0.06 grains per (sq ft) (flr). Permeance required for this ib q 06 = Perms 0T ^ess- ^ more re sistant print film on the plaster, reducing the paint-plaster-lath permeance to 0.19 perms would accomplish this. When the critical plane for condensation is unknown, or for a more informative, graphical representation of the situation throughout the wall, temperatures and JJPor pressures may be calculated and plotted as in Fig. 2. The vapor pressures nroughout the wall, for continuity of flow, are calculated in a manner similar to the ^mperatures; the external vapor pressures are given, and the vapor pressure drops across each element are taken in proportion to resistance to vapor flow. wallcuisrvaelsofosrhsoawtunriantiFoing.v2apaonrdpisresseseunretsoafat tllhbeevloawriothues cteumrvpeefroartuvraepsothr rporeusgshuoreust win! cntinuity of flow, toward the outer portions of the wall. This indicates that an<4 fire 6*ven temperatures and vapor pressures, continuity of flow is not possible j ? that condensation will occur. Condensation on the sheathing is indicated as a c ditionp,oassssibhioliwtyn,.anTdhtishenenwewcuvrvaepodroepsrensosturriesecuarbvoevecathnebseatcuornastitorunc-vteadpofor-rprtehsis-