Monsanto FROM (NAME 6 LOCAT 'oni w. B. PAPAGEORGE - ST. LOUIS DATE January 29, 1971 muBjrci REFERENCE PCB IN PLANT EFFLUENT -- TO J. Savage - JSAVA^^^/ ec . J. Mason .... - H. Bergen F. Holzapfel P. /Hodges W./ Richard JMASO HBERG FHOLZ PH0I)G WRICH Early In 1970 we established a target of 10 ppb of PCB's in our plant waste streams which we expected to achieve by the third quarter 1971. No specific target was established for the quantity of PCB we could tolerate in the atmosphere. During the year as the plants gained tighter control of known sources of PCB pollution, it became increas ingly obvious that high levels would continue be cause of the PCB's trapped in the soil and in the sewer systems. Clean-up of these sources can be economically impractical. Our studies in Anniston designed to develop methods for removing PCB's from dilute water streams were Intended to provide us with a method for removing PCB's from isolated small waste streams. It appears that the PCB contamination is so widespread that all of the plant's effluent must be treated. This would result in a system more complex and costly than any one had anticipated and approaches tertiary treatment which at W. G. Krummrich plant is scheduled for com pletion by 1973- For 1971 I am proposing that 1 pound per day of PCB in the water effluent be achieved in our plants by Sept. 1972 and 1 pound per day to the atmosphere by year end. These are levels which I believe the regulatory agencies might tolerate. What must be done at each plant to achieve these ob jectives and what will it cost? ^-[4^/5 0 W. B. PAPAGEORGE 005*750