Document aVk129DJ3a99eaZLNDqE8QmN

Monsanto CALL REPORT -- OftGANfC DfVBl DICTATE IN SEQUENCE: 1. HEADING INFORMATION 2. NAMES OF ADDRESSEES 3. NAMES OF CARBONEES 4. IMMEDIATE ACTION NEEDED *>. REPORT ON CALL CUSTOMER NAME ELECTRONIC COMPONENTS CITY AND SUIE Bridgeport, Conn. NAME AND TITLE REPORT CAPTIONS: 1. OBJECTIVE 2. PERSONS CONTACTED 3. RESULTS 4. ACTION REQUIRED REGION SERVICE CENTER New York ..S1jt gran msTn. CATCOONV COOKS cr "!r&. Bryant TO p. o. Penlgnua N. T. Johnson CC p. it. Munch CONTACTED: Pay Clark, President; Olerm Fayno, Chief Eng.; Mike Glanottl, Tech. PURPOSE: Discuss conversion to MCS 1016 and review problems In "cleaning up" formerly waste Aroclor. RESULTS: No problems anticipated with Aroclor 1016. Fay Clark seeks notification on the first shipment. Clark had visitors from Whirlpool which did not leave him optimistic on motor run type capacitors. Whirlpool presently is pro ducing 2400 Air Conditioning units vs. their peak load of 3500 units par day. Ray says they project a steady pattern with a growth of 5-100 but do not foresea any boom in sales. Clark feels this swans they have worked orf the large stock of capacitors in inventory and they are not about to restock heavily under present conditions. Toured the facilities and the plant la extbemely clean, free of of Aroclor spillage etc. Fayno felt that under best conditions Aroclor only had about 5 more years. Reviewed Porocel column adsorption and cleaning of Aroclor. They have built a 5 feet column about six inches in diameter for recycling Aroclor. S . 331 |Rl V, 3 - SERVICE CENTER COPY NCNS 072419 Monsanto CALL REPORT - ORGANIC OfVBI DICTATE IN SEQUENCE: 1. HEADING INFORMATION 2. NAMES OF ADDRESSEES 3. NAMES OF CARBONEES 4. IMMEDIATE ACTION NEEDED 5. REPORT ON CALL CUSTOMER NAME _____ FTJTCTKPMTr; ROMPOMFHTS_____________________ ClIY AND STATE OAIC RECEIVED Date or cau oatc rrtco CUSTOMER MAILING LIST CHANGES - SERVICE CENTER USE ONLY NAME AND TITLE CAItGOHV COM* REPORT CAPTIONS; 1. OBJECTIVE 2. PERSONS CONTACTED 3. RESULTS 4. ACTION REQUIRED SEAVICt CENK* TO CC Two There Is no question about which scavenger they uae. I saw the 55 gallon drum with an>f EFL 4206 label with the container etc. for addition to the Arcelor. A mgjor problem EC has on PCE control la the Aroelor 1254 used In their vacuum diffusion pumps becomes diluted with Aroelor 1254 which necessitates refilling the system. The operating conditions are 350F-400F at a vacuum of 500-1000 microns. The Model pump Is 900-150-8-dtokes. Recommended the operating temperature be dropped to 3?5F and Aroelor 1242 tried In the system. This keeps the vapor pressure about the same. A complete copy of the.Tecumseh Specifications are attached. This primarily for Dr. Munch but it doea spell out the various systems employed^ meet the Tecumseh Standards. FOLLOW UPl. 1. Follow up temperature drop on the diffusion pump and change out to Aroelor 1242. 2. Follow up visit with Frank DIJacomo at Totowa. Attachment i - 331 |AV. 12/61) 3 - SERVICE CENTER COPY HOMS 072420