Industrial Hygiene Survey
Summary
Th!! * survey of the Friction Products Building on Feb. 12 and 21, 1985 to determine employee exposure levels to asbestos, total particulate/graphite and lead dust.
All other sample results indlea.ted employee exposure levels below the PEL'S for asbestos and total particulate/graphite.
If you have questions pertaining to this report, contact the writer.
hm Attachment
A. C. Barbaglia Industrial Hygienist
Mote: In accordance with the suggestion of Mr. Sperlich and Mr. Greenwald we are submitting only an executive summary for distribution. If you need backup information, please notify this office.
cc: F. A. Burnett D. S. Buza G. Chomakos R. Grynlewicz R. 0. Horoky
N. McCallum O. J. Robinson, M.0. A. H. Sokolowski, M.D. G. A. Sattelmeier M. Teodosic
Discussion
The remonitoring of the mixer/weigh up stations Indicated that the employees' exposure level to lead dust was at or above the permissible exposure limit (PEL) of 50 pg/m* for an 8-hour time-weighted average. These results confirm the previous survey results which demonstrated employees exposed to concentrations of lead In excess of the PEL.
The plant should begin a three prong attack on the problem:
1. Explore other methods of adding the lead to the mixer.
2. Add perimeter exhaust ventilation on mixer access doors.
3. Mandatory respiratory protection NPSP 220 or equivalent.
Implementation of the above recommendation will bring the plant Into complalnce with applicable regulations and reduce employee exposure level to lead dust.
An employee complaint was evaluated In the Dynamometer room alleging excessive exposure levels to asbestos dust during the Bond abuse test. In addition, the Union requested the area near the employee time clocks be sampled for asbestos dust.
Both sample results Indicated concentrations of asbestos dust were less than 0.1 flbers/cc, well below the PEL of 0.5 flbers/cc. Further action is not anticipated at this time.
Data Sheet Trenton Chemical Plant February 12 and 21, 1985
Asbestos
Permissible Exposure Limit February 12, 1985 Area Sample Bay 8 .C-l, Adjacent to employee time clocks, across from mixers 1-4
February 21. 1985 R. King #369-56-1782 Friction Products - Dynamometer bond abuse operator
Concentration (Ubers/cc)" 0.5
< 0.1
< 0.1
Samples were collected on cellulose ester filters using MSA Model G Pumps and analyzed by phase contrast microscopy.
^CHRYSLE
CORPORAT1C
March 27, 1985'
Mr. Louis Heidmous International Representative Chrysler Department International Union, UAW 8000 E. Jefferson Ave., Detroit, Michigan 48214 Dear Mr. Heidmous: Enclosed is the report of findings of the Industrial Hygiene study conducted at the Trenton Chemical Plant on February 12 and 21, 1985 by A. C. Barbaglia. Mr. 6. Plckrell, the Union Member of the Local Joint Committee on Health and Safety, was informed of this study. In order to control the employees' exposure level to lead dust It was recommended that:
1. The plant install exhaust ventilation at mixer access door. 2. Mandatory respirator protection, NPSP 220 or equivalent
for employees overexposed. 3. Engineering should evaluate other ways of adding lead
to mixer Sincerely
G.A. Sattelmeler Manager, Industrial Hygiene hm Attachments cc: F. A. Burnett