Document aJk2E2y8jjg4rM7KMgwk7v5ba
PLAINTIFF' EXHIBIT ASI-26
1
more engineering more material and labor more experience make the difference
2
morO engineering: From the design stage, right through to the finished product, the skill and experience of Kewanee engineers is applied continually. First in the de signing and proper proportioning of boilers to assure maxi mum steam production . . . then studying each step of their manufacture . . . and finally in numerous tests of the finished product to make certain it performs as planned.
more material goes into Kewanees to insure extra
strength and the generous sizing of all parts that equips them to handle large overloads with efficiency. Even the Kewanee Boilers of compact design . . . intended for use when less floor space or head room is available . . . are never skimped in materials or measurements hence operate at full efficiency throughout their entire firing range.
morO labor is put into Kewanees. Notice the smooth
riveting, the carefully welded seams, the fine finish of all cast parts! This requires more labor but it puts something extra into the boilers that reflects quality.
more experience: Over 85 years of boiler build
ing experience can't be matched by guesswork. When a Kewanee goes onto a job the owner gets all the "know how" Kewanee has accumulated during many years of fabricating boilers of steel.
These are things . . . some of them intangible . . . which make Kewanee Boilers different and better.
nationwide representation: There is a Ke
wanee representative as near as your telephone and every branch is staffed with men who know boilers and the many problems of generating steam. They are anxious to serve you. See back cover for listing of branch offices.
Copyright 1933 Kowonoo-Ross Corporation
high pressure boilers
number of
sires
15 8 6 13
SBI hp rating
from
to
30 304 61 304 7 36 39 304
pressure
125-150 125-150
125 125-150
characteristics
riveted firebox welded firebox scotch type scotch type
low pressure boilers
number of
sizes
13 11 15
SBI rating--sq ft
steam
water
from
to
from
to
5470 42500 8750 68000 7290 42500 11660 68000 4250 42500 6800 68000
characteristics
scotch type welded firebox welded firebox
series no.
500 Hi-Test Scottie Jr. M-800
1
| page
' 4-5 j 6-7 8-9 ! 10-13
series no.
M-800
Type "C"
5000
'
page
: 10-13 ; 14-15 , 16-17
residential boilers
number of
sizes
12 4 1
SBI net rating--sq ft
steam
water
from to from to
900 5000 1440 8000 400 900 640 1440
510 510 510 510
characteristics
series no.
welded horizontal tube welded horizontal tube welded vertical tube welded boiler-burner unit
Square-Heat Round "R" Cottage VT510 Cottage VT510-U
| page
! 18-19 ' 20-21 1 22 ' 23
water heating equipment
number
Of sizes
5 1 29
capacity--gal
from to 165 700 140 140 95 2240
--> characteristics l welded | welded ) welded
series no.
page
i Tabasco
24
1 Cottage VT510-DW i 25
| Storage Water Heater | 26
accessories
induced draft water heating coils water heating coils structural steel supports safety valves
| characteristics
t j storage tank & instantaneous--commercial boilers
storage tank & instantaneous--residential boilers
j high pressure boilers
page
27 28 29 30 31
Kewanee-Ross Corporation
Dmkmm tt Iwum *--e> A UaMa>4 Umtary Upet'O
KEWANEE, ILLINOIS
500 Series ... heavy duty
15 sizes ... 30 to 304 hp 125 and 1 50 lb swp
for heavy-duty service providing heat for large apart
ments, schools, hospitals, office buildings and factories, or tor p.'cver or process steam . . . Kcwanee '500`' is a :ejl gianr. It is strong, dependable and very efficient. A two-pass firebox t\pe, it a the design which made the name Kewanee famous.
From top to bottom and from front to rear it is built with fust one idea ... to make it the most efficient, dependable and lung lived boiler that can be constructed.
Big high fireboxes provide plenty of space and air for the fuel to combine wath oxygen and burn, completing the process of combus tion before the gases reach the return tubes. In the long travel of the hot gases through the firebox and the lower tubes, men through the upper tubes to the exit chamber, all usable heat is tranMtrrtd 'o the boiler's water.
Water surrounds both upper and lower banks of tubes and all sides and top of the fire chamber so the transfer of heat is rapid anJ certain. Waterways are free of obstructions promoting rapid rise of the steam bubbles to the steam disengaging area and into the ca pacious steam chamber at the top of the boiler.
The use of 3 inch tubes permits more tubes and more heating sur face further helping make the "500" a very fast and efficient steamer. And this efficiency is maintained even when the boiler is pushed :o produce 50%. and more steam than is guaranteed bv its rated capacity.
Both banks of tubes are easily accessible through the larce Joors at front and rear . . . manholes and hand holes Dm*.-oe access to the waterways.
Sptctficatio'ts and data art
tor mechanically-fired ;
F - .n--:'"'.,-
u.n
haid-irea coal type i
;*e nearrit Keaane. < rp'r 'c
<.
ratings mechanically fired -- oil, gas or coal
bailor number
'Qting--horsepower . .
--iftam radiotion
sq ft
--6*u per hour
000`s
---ntegm per hour 212 F lb
574
30 4250 1020 1050
firing rote-"-Oil gph* . . . --gat 4tu per hr 000`i
13 1910
heating jurface <S8I mini f,,rnac volume {SBI mini . furnace height 'SBI mm) .
q ft cu ft ft-in
250 30.4
2-6
fireboji voi above mud ring eu ft
"odditionoi furnece height for
stoker (S8I mm]
ft-m.
39.6
,ofety vosve copoc>ty --oil-goi Bred lb steam per hr --itocer fired ib iteom per hr
2000 1750
577
578
579
580
581
35 4860 1 166
1 200
39 5470 13U 1350
44 6080 1459 1500
52 7290 1750 1800
61 8500 2040
2100
15 2180
16 2460
18 2740
22 3280
26 3830
266 34 6
2-6'/j
322 39.1
2-7'/,
350 43.5
2-7V*
429 52.1
2-834
500 60.8 2-10
39 6
48.5
40.5
62 1
69 6
582
583
584
585
506
74 10330
2479 2560
87 12150 2916 3010
109 15180
3643
3750
130 18220
4373
4510
1 52 21250
5100 5260
31 4650
37 5460
46 6840
54 8200
64 9560
608 73.8 2-11 Z2
715 86.8
3-1/2
893 108.5
3-4%
1072 130.2
3-7
1250 151 8 3-10
97.0
1 10.4 130.9
137.2
160.2
587
174 24290
5830 6010
588
217 30360
72B6 7510
589
26! 36*30
870 9010
590
304 42500 !o;oo 10510
73 10920
91 13670
' 10 164C0
; 27 19120
U29 173.5
4-0 M
1786 216.9
4-6/j
2143 260 3
5-0,/j
2500 303 6
56
183.2
207 8
231.9
2 4 5.5
0-6
2288 2002
2576 2254
2864 2506
3432 3003
4000 3500
4864 4256
5720 5005
7144 6251
8576 7504
10000 8750
11432 10003
14288 1 2502
171 *4 15001
20000 '7530
Fuel burning roles based on 150,000 8fu oil. Represents distance below bottom of water leg that dearth must be let for SBI minimum furnace volume and height.
Standard equipment--pront and rear base panels have 8'/j * I 1 /j In. opening and cover plate Flue cleoner and hondle. Manhole furnished on 580 and larger. Baffle plate m reor combustion chomoer furnnhed on 576 to 588.
Standard trim, staam only--Sofety valve, steam gauge with ivohon and cock; water column wlfh water-gage glots and t.iree gage cocks, chain operetta on 536 and larger.
4
w -- Y-
-Z -zz
dimensi and data (feet--Inches)
boiler numbtf
A---boiler diameter.......................... fr--ooilar length................................ C--boiler height............................. 0 -wqt>r line height.....................
6 -water column height. . ............. F--attorn supply height..................
G--tmoke outlet height............... H--i-eor stand height
J-^1eom supply
...................
*K--safety valve-. .
...............
M--feed <*oler. each tide . ...
N--blow-off height..
O--fireoo*--w>dth................... P--- --length.......................... 8-- --height
T--oose---width . .
U-- --length.... V-- --height.
............... ...............
W--smoke outlet--length. ...
X--
--width.
Y--
--location. .
I--teor door eleorance, min
AA--foundation--width.
BB--
--length.. ..
CC--rear stand. .
FF * GG--ffredoor opening m boiler width height, , .
MM--centerline elr to ftredoor opg KK--opened Rredoor to boiler
ZZ--tube replacement tpace
oreecnmg diameter--one boiler itocn--diameter.........................
--height. .,
breeching diometer --two boilers stock--diameter...............
--height...... ...
"steam supply size.......................... blow-off size ........................ feed water size...
"outside surface to cover sp ft
opptokimote weight -- 1 25 lb swp............ -- 1 50 lb swp.
lb lb
576 577 578 579 580 SI1 582
3-6 8-7 6-87, 6-1
5-1 1 7-2
5*1 1 3-2
6-0 4-5 2-3 1-7
3-0 4-2 3-57,
3-IP/, 4*1 I'/j
1-2
2-8 0-9 0-6'/, 3-6
3-0 3-6/i 2-9
3-6 9-6/, 6-87, O-l
5-1 1 7-2
5*U 3-2
6-6 4-5 2-9 1-7
3-0 4-2 3-5/j
3-11 7, 4-11/1
1-2
2-8 0-9 0-6/i 3-6
3-0 3-6/i 3-8
4-0 8-11'/,
7-2'/i 6-4
6-2 7-8 6-2 3-2"
6*0 4-5 2-6 1-7
3-6 4-2 3-8
4-57, 4-11/i
1-2
2-10 0-1 1
0-7/j 4-0
3-6 3-6/, 3-0
4-0 9-8 7-2/, 6-4
6-2 7-8 6-2 3-2
6-6 4-5 2-8 1-7
3-6 4-2 3-8
4-5'/, 4- ! /,
1-2
2-10 0-1 1
0*7ft 4-0
3-6 3-6/, 3-8
4-6 9* 2'4 7-10'/, 6-1 1
6-9 8-5 6*9 3-4
2-iy, 4-5 2-7 1-7
4-0 4*2 4-1
4-n/i 4-1 !/,
1-2
3-4 1-0 0-8 2-6
4-0 3-6/, 3-3
4-6 10*6 7-10'/, 6-1 1
6-9 8-5 6-9 3-4
2-!/, 4-11 2-n
1-7
4-0 4-8 4-1
4-1 P/, 5-5'/, 1-2
3-4 1-0 0-8 2-6
4-0 4-0/, 4.0
5-0 11-1
8-6 7-4
7-2 9-1 7-3 3-5
3-4 6-4 2-9 1-10
4-5 6-0 4.1
5-6 6-1 1
1-5
3-8 1-2 0-9 2-9
4-5 5-6 3-0
584
5-0 12-9
8-6 7-4
7-2 9-1 7-3 3-5
3-6 6-11
3-2 1-30
4-5 6-10
4-1
5-6 7-9 1-5
3-8 1-2 0-9 2-9
4-5 6-4 3-10
584
5-6 12-10
9-0 7-9
7-7 9-7 7-7 3-5
3-9 6-11
3-2 M0
4-1 1 6-10
4-4
6-0 7-9 1-5
4-3 1-3 0-9'/, 3-0
4-1 1 6-4 4-0
5tS
5-6 I 4-9
9-0 7-9
7-7 9-7 7-7 3-5
3-8 7-3 3-9 M0
4-1 1 7-2 4-4
6-0 8-1 1-5
4-3 1-3 0-9'/, 3-0
4-1 1 6-8 5-6
514
6-0 14-9
9-6 8-PA
7.1 pa 10-1
8-1 3-5
3-8 7-3 3-5 M0
5-5 7-2 4-61/,
6-6 a-t 1-5
4-8 1-7 o-i PA 3-3
5-5 6-8 S-6
587
6-6 1 4-9
9-8 8-4
8-2 10-3
8-2 3-1
2-9/, 7-7 3-7 M0
5-11 7-6 4-7
7-0 8-5 1-5
5-0 1-6 0-1 1 3-6
5-11 7-0 5-2
588
6-6 17-7*/,
9-8 8-4
8-2 10-2 A
8-2 3-1
12-6 U-8
4.1 M0
5-11 8-6 4-7
7-0 9-5 1-5
5-0 1-6 o-u 3-6
5-1 1 8-0
6-10
589
7-0 17-9 A 10-6
9-0
8-10 11-07,
9-0 3-5
1 2-6 U-8
4-3 2-2
6-5 8-6 4-9
7-67, 9-5 1-9
5-4 M0
i-l 3-9
6-5 3-9 6-8
590
7-0 20-O'A 10-6
9-0
8-' 0 i i-oA
9-0 3-5
1 3-3 16-5
4-3 2-2
o-5 9-0 4-9
7-6/, 9.11
19
5-4 M0
1.1 3-9
6-5 3-6 70
one 2-3 k. M
1-8
6*10
1-7 1-5 45-0
2-1 Ml 55-0
0-4 0-1 7, 0-1 '/<
130
1-8
7-9
1-8 1-6 50-0
2-2 2-0 60-0
0-4 - 0-1 '/,
0-1 %
140
1-8
6-10
1-9 1-7 45-0
2-3 2-1 55-0
0-4 0-1 /, o-l %
1 50
1-8
7-7
1-10 1-8
50-0
2-4 2-2 60-0
0-4 0-1A o-l /
1 60
0-574 2-3
6-9
1-1 1 1-9
45-0
2-6 2-4 55-0
0-4 0-2 0-1 Va
180
0-5 7* 2-3
8-1
2-0 1-10 50-0
2-7 2-5 60-0
0-4 0-2 0-1 'A
1 95
two 1 -1 A 1-3
0-8 0-8 0-1 1 2-3 2-3 2-3
a-4 10-0 10-1
2-2 2-0 50-0
2-4 2-2 60-0
2-6 2-4
60-0
2-10 2-8
60-0
3-0 2-10 70-0
3-4 3-1 70-0
0-6 0-2 0-PA
0-6 . 0-6 0-2 0-2 0-1 7, O-l1/,
225 255 285
0-1 1 2-3
12-0
2-7 2-5 70-0
3-5 3-2 80-0
0-60-2 0-PA
320
0-1 1 2-6
1 1-8
2-9 2-7 70-0
3-8 3-5 80.0
0-6 0-2'A 0-1 7,
340
two 1 -6 * ' 4
' i 7* 2-6
MV* 2-4
2-6
1 1 .4
14-2
'4.0
2-H 2-9
70-0
3-3 3-0 85-0
3-5 3-2 90-:
3-1 ! 38
00-0
4-2 i-i i 95-0
4.2 100-0
0-6 0-2'A 0-'7,
0-8 0- 2'/, 0-1 A
33-3 0-2
360 4 1 S 455
: .4V4 2-6 ' 5-3 3-7 3-4
4-a
1 15.0 :-a 3-2 7, 3-2 505
7980 8780
8510 9360
9590 10550
10100 mio
1 1700 5 2 870
12760 l 4030
14930 1 6420
16530 18180
19230 21 1 50
21940 24130
24100 26510
26840 29520
31210 34330
350CC 38500
23320 42700
For safety valves, tee page 31.
**300 >b American Standard Flonge.
'"Includei front head and smekebo*.
Kewanee-Ross Corporation
Dkmmr
leMt 4 Vender* 6e*leri Cor*er-w>
KEWANEE, ILLINOIS
5
Hi-Test for power
or industrial process steam
8 sizes ... 61 to 304 hp 125 and 1 50 lb swp
The Kewanee Hi-Tcst Scrub is an excellent example <? a
ail weld boiler.
fusion electric welding. loints of unquestioned
strength are obtained, then X-Ray checked n> be certain th.i: : :e
seams are perfect. The entire boiler i> then placed m .1 huue S:ri."
Relieving Furnace where the joints are thoroughly anne.n.d :!xn
allowed to cool gradually, eliminating am- pissibihtv -t ! vkeu an
stresses. Tins ts the Number l VC eld procedure t>d!
i.i
welded Kewanees for high pressure.
The finished boiler is further subiected to hydrostatic U't rrc--
<ures equal to one jnd one-half times its allowable u.i'rkna >K-"uri.
in accordance with ASME Code requirements Each NuLr is riu a''.
inspected . . during construction and when v.-mpleted
Sv i
oualiried inspecror licensed by the Xjtionul Board or Boiler and
Pressure Vessel inspectors to insure acceptance &y an-, state ->r
municipality.
Kewanee Hi-Test is
in design. Two cylindrical shells of
different diameters are joined with tube heads, ruth only a few
diagonal head braces needed. The front and rejr due gas chambers
are an integral part of the boiler shell, eliminating joints.
The metal casing on the front of the boiler, which forms the 5re chamber, is designed for a refractory lining (not furnished as part of the boiler), making n entirely self-contained.
Hi-Test Kewanee mav be fired from the front or rear
with
ail fuels. For information on the Hi-Test for hand-nrinc. consult
your local Kewanee representative.
Specibcjiions and data are sr-:wn i >r mechanu jity-nrta
r -.*
tir,n
hand tired
I'-pei ijnu.il :hc neareti Keuanee r>e. en:11.
ratings mechanically fired oil, gas or coal
boiler number
rar-ng--norse power --fttu per hour --steam per hour--2 1 2* f
tiding 'Ote--O'l gp^' --got fltu per hour . .
heo'ing turf ace. furnace *Oiume m casing .
safetv valve capocity --pil-gas fired . --Voter fired .
..
1300's . ...lb
1 000's
sa ft eu ft
lb iteam per hr lb iteom per hr
HT50
HT60
HT7J
HT100 : HT123
61 2040 2100
26 3800
500 82
73 2448 i 2520 | _____________
91 3060 3150
31 4600
600 101
38 | 5700 ) | 750
M7
122 4080 4200
. ^2 l 5100 5260
: 51 1 7700
i 64 : 9600
1"" 1 1000 j 1 250 ! 155 j i 98
4000 3500
4800 4200
I 6QQ0 j 5250
!
! 8000 | 7000
i
j 1QQ00 j 8750
HT1 JO
1 82 6120 6310
76 1 1400
1500 233
12000 10500
MT200 HT250
243 9'60 341 0
' 02 ! 53CO
'"A 1 0200 ; os- o
-7 ' a*
2000 300
2500 349
16000 i 200C0 14000 1 17500
Pu.| burning 'Ql#t DOjfld On '50,000 Btu Oil.
Standard e<ju<pm*nt--Standord Heel easing *t*nding to top of masonry bos*. No be from *urmsned. Damp*r in smoit* cutlet. Flu* clanr* with handtai.
Standard rrinw-Staam gag* with siphon end cock; high and low wot*r alarm column with inclined gag* glass and chcin oo*roi*d gag* saw; chain oo*rat*d try cocks safety valves as raauirad by ASmE cod*, oiow-o* valve and cock, globe and c-ecs ai* for feed pip*. Np other accessories or piping. Special trimmings furnished at addifionol cost.
6
a
o 1)
dimensions and data (feet--i..cne,)
bailor number
HTSO
HT60
HT7S
HT10O HT123
HT150
HT20O
HT2J0
A-^ylinder diameter--rear.............................................................................................................................
8--
--front.................
........................
.............................
C--boiler length
D--water lino height
E--wotor column height
F-*--steam supply height G--smoko outlet height H--saddle height, front & rear
J--iteom supply *K --safety walye M--feed water, eoch side N--btow-off
0---furnace--width P-- --'ength R-- --height
S--furnace casing--height
T-- --width ..................
U--
--length ................
V--^hell e Mention beyond cosing. , .
W--smoke outlet--length X-- --width
Y-- --location Z--'ea' door cleorance, mm.
A A--base--width
88-- --side wall thickness
CC--
--front woil rhicunesi
00-- --ear wail thickness.
EE ---rear brick pier. Ff--rear brick pier width. ZZ--tube replacement space
...
...
breeching diomeer--one boiler
stack--diameter . --neight
breeching diameter- two boilers Hock--diameter.. . .
--height
**iteam supply use blow-off site .... feed water size
"firebrick m coting **2 insulation immg m furnace
,a ft
outside surface to cover
iQ ft
approximate weight, bailer--125 lb swp. -- 1 50 lb iwp.
ib lb
5*6 3-6 12*5 6-8
6*6 8*2 7-5 2-2
10-1 4-5
2-10 2-8
4-0 4.8 3* i 0*/a
5.1 I 5-10
6-6 0-10
3-0 1-2 0-9 3-0
6-6 1-3 0-11 Ml
2-0 2-8 7-7
2-0 1.10 45-0
2-7 2-5 55-0
0-4 0-2 0-1 V*
1300 130
115
1 2470 12570
5-6 3-6 13-5 7-2
7-0 8-9 7-11 2-8
10-8 4-6 3-3 2-8
4-0 5-2 4-4'/,
6-5 5-10
7-0 Q-10
3-0 1-2 0-9 3-0
6-6 1-3 Q-H Ml
2-6 2-8 8-7
2-2 2-0 50-0
2-10 2-8
60-0
0-6 0-2 0-1 '/,
1450 155
1 45
14080 U280
6-0 3-6 14-3 7-2
7-0 8-9 7-11 2-2
1 1-3 4-6 3-6 2-8-
4-5 5-2 4-4'/,
6-7 6-3 7-4 /, 0-10
3-0 1-2 0-9 3-3
6-1 1 1-3
0-1 1 2-4
2-n 2-8 9-5
2-5 2-3 55-0
3-2 3-0 65-0
0-6 0-2 0-1 Vl
1700 165
165
17405 17805
6-6 4-0 15-5 7-9
7-7 9-7 8-9 2-6
12-2 4-6 3-7
2-10
4-1 1 5-8 4-8'rt
7-3 7-6 8-3 0-8
3-6 1-4 0-10 3-6
8-2 1-7'/, 1-3'/, 2-4
3-3 3-0 10*1
2-7 2-5 60-0
3-5 3-2 70-0
0-6 0-2 o-i Vi
2750 205
200
21070 21570
7-0 4-6 16-2 8-10
8-8 10-11
10-1 3-4
12-5 5-0 3-9 3-0
5-5 5-8 5-6'/,
8-4 8-0 8-3 0-10
3-10 1-6
0-1 1 3-9
8-8 1-7'/, 1 - 3 '/, 2-4
3-8 3-6 10-4
2-9 2-7 65-0
3-8 3-5 75-0
0-6 0-2'/, 0-!'/,
3250 235
250
24630 25330
7-0 4-6 18-6 8-10
8-8 10-11
10-1 3-4
14-9 5-3 3-9 3-0
5-5 6-8 5*6'/,
8-4 8-0 9-3 0-10
3-10 1-6
0-11 3-9
8-8 1-7'/, 1-3'/, 2-4
5-0 3-6 12-8
3-0 2-10 70-0
4-0 3-9 80-0
0-6 0-2'/, o-iv.
3500 260
300
28000 28700
7-6 5-0 19-5 9.7
9-5 1 M0
1 l -0 3-9
15-a
3-9 3-3
6-0 7.7 6-0 9-4 a-7 10-2 0-'0
6 0-1 1
4-0
9-3 . 7 Vj 3 V,
2.4
5-0
1 3-7
3-5 3-2 30-0
3-0 5-6 20-n 9-3
12-4 11.6
3-9
7- 0 k-5
3-1 6-0 97 9-1 10-8 0 1 o
>
4-3
7Vj
24
3-4 95-3
4. 2 90-0
0-8 o-:v, 0-2
'05-0 0-2
340 Ji5
32 5 ;
32000 330G0
37000
For safety vafeoi, see page 31. 300 lb Ametieon Standard flange. *** No brickwork, furnace refroetory or insulation includ'd.
Kewanee-Ross Corporation
K.EWANEE, ILLINOIS
f. ' .1
1
ScottieJunior
6 sixes . . . 7 to 36 hp
125 lb swp
Originally designed Mr >hips with?'limited space .and head r-'bm.
Kewjnce Scotch , pe boilers *pr<i' ide the'>ulufton ;'ur many-.p-.-wer
and industrial process steam,problems/;
1
Shell of flange quality steej, <vi:h a: tw<ite'-i*nu:h-.t
5^.090.to'6V'i)0i p*'unJs per square inch. Lmduudin.il fi-mr > riv
eted' with Joublc, butt -trap copytiuction. Girthye!:V.x ire, nwtvd and caulked uuht/around "the nJjcII, edge's* and at .t-ucivlnj\*t. :he welded furnace.. .Solid thr"Ui;iwu\s complc-ie front .to, V. `*r.;cma.
Rear combustionchamber , -.vith hVch
re
fractory lining -installed' at the tactory.r . *
j' . ' , , . -
tong gas trayol tn the reartBrnuch/fhe -furnace
:.\n ;o'
the tro'nfhthroughrheayy' 'id age- }>" 'nre tubes \ v t/. n^vr' '.hi
usable heat'to the water.
'. -
,,"
Longer.
creates ideal. .Home conditions :>
^firing with any. standard" gun-type' burner. r- :
`
Mounted oh Isklds*: . i Scottie Jr., arrives' ' , ,,v
hstantial, wood skids. No; foundation is- needed. 'St t
at-extra cost.
,
d.
s !'- .
`available
Heads, hot flanged of firebox quality, Steel and tube holes
jtrepanned^from solid^'plate. r-
h ''
'
Heavy cast iron doors precision ground for gas tight' fit.'
Heavily insulated to' prevent warping,'/ m
1
Threaded flange .steam outlet assures tight fitting..-:--_bie-
proof connection-with <ream mains;
"!,*\ :
Large Steam space assures,, ampie reserve'* '1* /ti.-im.', L'ncbstrucred disengaging area it voter'line keeps .the/Veam'dry.' . ,
ratings mechanically fired --oil or gas
r!-
: 5.. : 'V *
bailer number
rating--hone power --Btj per novr --*teom per nar--2 1 2 ' F .
| i I
j
certified output rating ... firing foic--oil gpn* --go* 8tw oer hour. ..
heating turtace... furnace volume
>
safety vaive capacity
* Fvel burning rotes bated on 140.000 8tu oil.
I000-*. . ib |
ip j
1000'* j
IQ ft \Cu ft l
>b (team per hr {
HM4 - o- HM9
7. 234 242
12 410
' 0.5 `3.5 4 80
`I 18
58 ' 1 810 ,
60 '5
. j ~ , V ' 24;V ,
4 30 i 79?_
HM,S4
..r^HMas^ . .
`MM JO"
'''' 3
400 _ 62C
*' <
24'.-'r,./v '300 !' -V'; -.;930, /,
.30 f l 020 ' ; ;oso-1'
-.r
3i . . *:*h
liz
,
27 j . 8-r . 1 1200 , ;
36- *
11.5
!
.. 1620' .
IS , *14.4' -T 2030^ *
' ' K;
54 '7 3 2 430'
v V
'< - >50
- . 200' - -'j , 250.
'3 20 -
!-. 2. >t,`. ' }4 6 ; j .'473 w_ 5 3fl ^ f '
- ! 1200
* 1600 *
--1-- ; --- -M-
{. 2000 1 :
. 2400'
Standard equipment --- All boiler* counted on tkidi; manhole >n hm25 4` 30 refroctory
lined rear comauttion cnamaer. rear end plate with cleanout Poor, % >n. funble plug
*ocket wrench. Hue scraper with handle. Steel furnace entension with coverplate and
peephole.
j
Standard trim, steam only--Water cslumn with watef-goge g<d*s and *hp* ga^e cock*, ttearn goge, tiphon end'cock,'safety value; V<t 'in. Penderrhy 'n<ecor: n ^woff valve*.- doing ,and'.fitting* for attaching _trimmings to 'boiier. 'No irtmm.igj.* fumiihed w.ih hot woter boilers.'*
>
#
8
4'.
-N
B -G --
A
ACOtSS '0 r-S-BlC plus
6
. '--*--------- r
9LOWOFF -------------------------- R
HOSE STRA1NEB
s- Q
6`* 6' skios
o
i
dimensions and data (feet inches)
boiler number
A--Boiler diameter overall ................... 8--Boiler length overall ... C--boiiet shell height ... D--water line height
--water column height, EE--height from boiler CL F--vecm supp'v *G--nofe'v vQive
H^fumoce OiQmeter J--shell--diameter <-- --length
l--nmot outlet length
M--
--width
N--
---Cl to Ooiler.
O--
--height
P--cieoronce Beneoth sneil Q--legs location R--skids location $--CL f'onr leg to front head.
T--tube 'eoJocement ipaee
Breeching diameter stacA---diameter .
--height**
steam tupplv ure biow-o*T size - .
draH loss through Oosler
..
comoustion gases of smoke outlet cfnt at 600= p
outside surface to cover
approximate weight--on skids with regular futures
inches of gir
sg ft ib i
HM6
3-n 6-10 V*
4-67j 3-10'/,
3-3'/, 0-1P/4
M 1-3 1 -9 3-6 5-1
2-0 0-7 0-5"j 3-8
1 -0
3 2'/: 3-1 0-9 3-4
1-2 10 20 2
0-2 '-i
260 57
3400
* For safety valves, see page 31. ** For pressure atomizing ail Sumr or power gas burner
i
HM9
4-5 7-0/: 5-2 4-5
4-3 i-i >4 1-2 13
2-3 4-3 5-3
2-6 :-8 2.* 4.: i .i 3-3 V: 3-i 09
3-6 i -4 1-2 23-0
C-2 0.' 1'
3e 430
67
4730
HM15
4.5 8-9'/, 5-2 4-5
4-3 1.1 '4 1-6 1-3
2-3 4-0 7-3
2-6 0-3 0-6
4-2 1. i 3-7 3-6 1-3
5-3 1.5 1-3 2S.0
0-2 3-1 '4
07 650
90
' 5600
HM20
4-5 10-6'/:
5-2 4.5
4.3 M '4 2-0 '-4'/,
2-0 4-0 3-R 2-6 0-8 0-6
4-2
l-l 5-1 3-4 16
70 1-7 1-5 25-0
0-2
.10 860
l1 I 6400
HM25
4-11 10-7
5-7'/, 4.9'.,
4.7'/j 1-3 1-6 1-10 '/j 2-4 4-6 8-9
3-2 0-8 0-7"i 4-6";
5-0 3-9 I .6
6-11
1-8 ' -6 250
0-2 1 '4 0
; '080 , 125 | 7800
HM30
4-1 1 120
5-7": 4-9": 4-7'/: 1-3 2-0 ' -5 2-4 4-A ': 2
:3 :' ' A - ;
6-1 2? I5 9-4 -. ; 'i
; 4
05 i 2 300
Kewanee-Ross Corporation
isw & s*wefe Sowrom c*
KEVC'ANEE, ILLINOIS
ratings mechanically fired-- oil or gas
boiler number-- High prenure) --tow pressure
Sfil ratmg^-norseoower.. . ---sfeom radiation --water rodiotion . --Slu per nour --steam per nour---212' F
SBI net rating--iff am. --wafer --fltu per nour
cer'lfied Output rating firing rote--10<i gph*. . --goi 8tu per hour
hea'mg surface f SBI mm| furnace volume (SBI mn). net furnace volume
safety valve capacity --over 1 5 It twp ... -- I 5 lb jwp
fHM-878 HM-179 MM.IBO HM.BB1 HM-BB2 HM-883 ffM-884 MM-815 MM-886 &HM-487 IM-87B LM-879 tM-BBO LM-881 LM-182 LM.I83 LM-B84 IM-BBj LM-184 LM.BB7 IM-B88 IM-BB94 LM-890
sq ft sq ft IOOO'i
'b
. sq H sq ft
000's
hp
. 1000`s sg ft Cu ft cu ft
39 5470 8750 1313 1 350
4S00 7200 1080
59 16 2460
322 39.1 45 8
44 6060 9720 1 459 1500
5000 8000 1 200
66 18 2740
358 43 5 48.4
52 7290 11660 1750 1800
6000 9600 1 440
78 22 3280
429 52 1 57,9
61 8500 1 3600 2040 2100
7000 1 1200
'680
92 26 3830
500 60 8 62 4
74 10330 16520
2479 2560
8500 13600
2040
11 1 31
4650
608 73.8 79 8
87 12150 19440
2916 3010
10000 16000
2400
131 37
5460
715 86.8 87 5
109 15180 24280
3643 3750
12500 2CC00
3000
1 6a 46
6840
893 1 08.5 ! '0 2
1 30 18220 29150
4373 4510
15000 24000
3600
195 54
8200
1072 130.2 Ul 1
152 21250 34000
5100 5260
17500 2 8000
4200
223 64
9560
1250 151.8 1537
174 24290 38860
5830 6010
20000 32000
4800
261 73
10920
1 429 173.5 174 0
30360 48570
7286 7510
25000 40000
6000
326 91
13670
216.9 217.0
,
9010
7200 392
16400 262.9
"i
10 510
8 400 '9- :o
- r- -i 308 8
lb steam per hr b steam per nr
2576 1610
2864 1790
3432 2145
4000 2500
4364 3040
5720 3575
75 44 4465
8576 5360
10000 11432 6250 7145
14288 0930
17'4^ 10715
:::o
' Fu*< burning rotes based on 1 50,000 8tu oil.
Stondard equipment (15-125-150 lb steam)--Steel saddle support*, refractory lined rear comDushon cnamber factory installed. F'ue cleaner and handle. Woshout plug socket 'tenth for 1 5 lb boilers only,
Standard trim (15-125*150 lb steomi --Safety volvefs) as reauired by ASmE Code,
steam gage with s Dhon and cock,
column win water goge glass ond three gage
tacks. Choin operated water gage alvei and try cocks with boilers HM-884, LM-384 and larger.
Note--For 125 and 150 lb tteom boilers Ctobe ond check vg'ves for `eed : -<e. Quick action end slow ac'ion blow-off valves a* furnished.
Stondard equipment (woter boilers)--5leel saddle support!, refractory l.'#d rear combustion chamber factory installed. Flue cleaner ond handle. Wjpoui aiug socket wrench.
Stondard trim (wafer bo'lert)--None furnished. Additional equipment or trim of eitra cost.
10
M-800 series
* high pressure units ... 39 to 304 hp ... 125 and iso psi low pressure units . . . 1 5 psi steam or 30 psi water . . . 1,31 3,000 to 10,200,000 Btu
The Scotch type Kewanee M-800 is decidedly Scotch in its iuggedntss and extreme chriftiness when it comes to pro ducing steam economically. Designed and built to generate steam with ethciency through its entire tiring range, it .an be pushed tar above its rated capacity without interrupting its usual economical operation.
The M-800 is designed on S.2 square feet or" heating surface for each horsepower of its rated capacity. This proper pro portioning of primary and secondary heating surfaces :o the volume at water in the boiler comes onlv as a result of mar.v years of experience and continual testing to rind out ;.:>t what is right.
1 Shell s
from heavr fiance steel wrh heads and furnace
ur nrebox auuhr.. All \u-U' in
r.Ltnvc witn ApME C-Je.
Butlers tuc 115 and L50 psi stress rtueved.
2 Large steam chamber prmido rc-.c-nc tor exeruency
demands
3 Unbroken steam disengaging area permits -team to
ri^e Without unJue turbulence.
4 1 1 X 1 5 in. manhole and washout i-pcamgs give access
to w aterside.
5 Corrugated furnace for extra strength and added heating
surface next to the tire. Its generous size provides plenty of space for the burning fuel to mix with the air and burn completelv Low pressure boilers provided with plain circular furnace.
6 Heavy gage 3 in. tubes expanded into holes with ends
rirmly rolled and beaded.
7 Rear combustion chamber is heaviU n.! . ^ r-. trac
tor,\ Sailers :>t ;'.:ch pressure* incorporate a;'. '
:.',vn
Lww pressure boilers dcstgned with water ba^k n Vs*.' nal
rear cover plate with nbservattun port and Ju-ys
;j
fusible plug.
3 Sturdy steel saddle supports m mplify -nv:i in*: ,;nd
installation. No special base is required.
9 Long gas travel the length c.r the fire dumK: md .nto
the rear combustion chamber then forward
the l.-ng
tubes gives the water in the boiler a chance to ahv.irb all -he
heat . . . stepping up the transfer of heat without wasting it.
10 Rapid circulation through the unobstructed '.vaitrwavs
speedily sweeps the steam bubbles up without comm, aivn an important factor m making M-800 a fast -reamer
11 Substantial hinged flue doors, canted : r pc--i.
nent cas-tight fit. Provide ea<v access to fire :ubc< o r Jg.mmg and inspection.
'2 Gas tight smokebox t heaw pia .tK! . .v.i.ic ': ,n
me piece to boiler shell. Rectangular smoke outlet located it top.
certified high efficiency
Teamed with any good oil, gas or combination oi!-gas burner, Kewanee M-800 performs "on the |ob ' with overall effi ciencies of SOO and more. And this efficiency remains prac tically constant whether the boiler is being operated at 10rc or 1500 of its rated capacity.
Such efficiency figures are confirmed by certified performance tests in which the total amount of the heat in the oil or gas put into the burner and the amount of water evaporated into steam are carefully measured and converted into a figure show ing the overall operating efficiency.
A chart of typical boiler performance appears at. the right.
percent of boiler rating
40
60
80
100
120
140
Kewanee-Ross Corporation
et fc--m--
A Stttwdoe* SmWry Cnoramm
KEWANEE, ILLINOIS
l1
I I
M-800 series
i
... a great teammate for any quality oil, gas or combination oil-gas burner The Kewanee M-800 Boiler is 1de.1I tor use \\ ith any quality oil, gas or combination oil-gas burner to form a complete Boiler-Burner Unit. A ten- of the many features which make this boiler so adaptable to Bober -Burner Units are . . . complete range of sizes for both high and low pressures unusual strength and dependability ability to produce tar above rated capacities at highest efficiencies greater heating surface ease of cleaning and inspection steel skids that eliminate special base construction only two or three matching connections to make in mounting burners to Sober
frame Three Boiler Burner Units developed using the M-800 Series are shown at left. For additional information on these units, write for separate catalogs.
12
dimensions and data (feet--inches)
boiler number high pressure --low pressure
HM-878 LM-878
HM-879 LM-879
HM-880. HM-881 IM-08CT' LM-881
HM-882 IM-882
HM-883 LM-883
HM-884 LM.884
HM-883 LM-883
HM-886 IM-836
HM.887 IM-887
HM.888 LM-988
HM-889 LM-089
HM-890 IM-890
A--boiler diameter 8--noiler length.
4-6 1 t-8
4-6 12-7
5-0 1 1-7
5-0 12-9'/,
5-6 13-2
5-6 14-10
6-0 1 6-1
6-6 1 6-7
6-6 ! 8-7
7-0 *7-9
7-6 18-11 i
3-0 20-0
9-6 20-)
C--steam supply netght 0--smoke outlet height. i--water column height
6-6
6-6
7-0
7-0
7-6 7,
7-6'/,
3-07,
8-67,
8.6'/,
9-07,
9-7'/,
1 0-47,1 : 0-' 07,
6-4
6-4 6-10 6-10
7-4
7-4 7-10
8-4
8-4 8-10
9.4 ! 0-1
1 0-7
5-1
5-1
5-6
5-6
5-9'/,
5-97,
6-: 7,
6-57,
6-5 7,
6-97,
7-3
7- ' I1',
3-4
r---furnace 0 d. Of from G--furnace neight
2 - 3 /, 3-0
;y/> 3-0
2-6/i 3-1 7,
2-6 7, 3-1 7,
2-9/, 3-3
2-97, 3-3
2-1 1 7, 35
3-2 7, 3-6 7,
3-2 7, 3-6 7,
3-6 3-8
3-37, 3 ?7,
4- 1 4- 2 '
4-5 4 4 7,
M--s'eom supply ')--sofelv valve *--feea water, each side. i---eturn 1 5 ib vwp, eaen side. M -- OlOw-off
3*0 3-6 3-1 3-7 3-8 4-2 4-9 4-10 5-4 5-5 5-5 5-6 5-7
3-6 4-3 4-3 4.4 4-5 5-0 5-0 5-0 6-6 5-6 6-6 7.0 7-0
6-7 7-1
6-6 7.1
7-4 3-2 3-: 2 9-3 10-3 9-10 ' ;-6
4-4 4-4 4-4 4-4 4-9 4-9 5-3 5-8 6-2 6-3 6-5 6-7 6 7
4-0 4-0 4-0 4-0 4-3 4-3 4-5 5-4 5-4 5-6 5-6 5-6 5.6
N--smoke outlet--"width
O--
--length
0-11
0-1 1
1 -0
1-0
1-1
-!
-2 1-3 1 -3 1-4 1.4
-5 1-5
2-5 2.5 3-0 3-0 3-4
3-4
3-6 J.H
3-1 1
4-7
5-4
5-7 6- 1
P--support--length ,
B--
--wiath
S--
--neight .
T--
--location
U--
--center `O center
v--'j6r ioiocement sooce
3-1 17, 1 -4 -6 2*3
6-1 1
7-1
3-1 i'/j -4
I -6 2-3 7-10
3-'
4-5/2 1-5 1-6 2-4 6-9
6-' 1
4-57, 1-5 1-6 2-4 7.1 1
3-' 7,
5-1 '/, 1-6 1 -6 2-5 8-1
3-2
5-t Vj -6
1-6 2-8 9-6
9. ' ;
5-7*',
/ 1-6 2-9 ' 0-6
6-1 1-8 1 -6 2-10 1 0-6
' :-8
6-1 1-8 1-6 3.4 20
0-3
6-6 7, 1-10
6 3-5 11-0
7
7 - 0 7, i.io ;
1 -o j
'20 ' :-r
.
2-0 1 -9 3-6 2-0
6
72;
9 3-7
'0 2
sreecnmg aiometer--one OOtler stacs--dia meter
--neighf
.9 1-7 40-0
M0 `3
40-0
'11 I -9
35-0
2-0 1-10 40-0
2-2 2-0 40-0
2-4 2-2 45-0
2-6 2-4
50-0
2-7 2-5 50-0
2-9 2-7 55-0
2-1 1 2-9
50-0
3-3 3-0 55-0
i i i
3-2
2-7 3-4 55-0
preechmg diameter--two boilers. stock--diameter
--"eight
2-3 2-1 45-0
2-4 2-2 45-0
2-6 2-4
40-0
2-7 2-5 4 5-0
2-10 2-3
45-3
30 2-10 50-0
3-4 3-1 55-0
3-5 3-2 55-0
3-8 3-5 60-0
3-1 1 3-8
55-C
M4-2l j! 6o-o ;
A m:
4-3 1-4 r:-2
steam supply site- 1 5 lb iwp" . --aver 1 5lbswp***
blow-off site . . re'urn site 15 lb swp
feed water size
0-6 0-4
0-1 Vi 0-4
0-1 '/<
0-6 0-4
M Vi 0-4
0-1 7*
0-8 0-4 0-2 0-4
0-1 V*
0-3 0-4 0-2 0-4
0-1 %
0-8 0-6 0-2 0-4 o-l 7,
3-3 0-6 0-2 0-4 0-1 V,
0-8 0-6 0-2 0-4 o-l 7,
0-0 0-6 0-2 0-4 0- > 7,
0-8 0-6 0-2 7, 0-4
0-' 7,
0-8 0-6 0-2 7, 0-4
0-1 7,
o-io ; 0-3 0-2 7,!
:-6' 1
0-3 -o-:1, :-6* 0-2
:-3
Putside surface to caver
sa ft
: 65
' 80
30
200
230
260
305
340
330
390
I 5 00
oo;
approximate weight -- 1 5 lb swp
lb 7000
7400
8200
8800
11300
12 400
1 4800
*7400
19200
22400
1 26600 j 3 1 200
3 5000
--125 lb swp
V -- I 50 'b iwp
ib 7600 lb 3200
8000 8700
I 0000 10400
11100 1 1 500
13100 13900
uooo 15100
17500 1 8700
20800 2 2700
21900 24900
27100 28700
32000 1 07200
34500
40100
4'900 i 5 ' 20
For sofety valves, see page 31. ** 150 lb American Standard Flange. *** 300 lb American Standard Flange.
Low pressure ooiien furnished with openings for 0*1 neater
Migh pressure boilers furnished w.th openings tor ail neoter
and lemperature control.
and sector.
Overall height is increased ! /, in. nn iteel ...as rre furnished.
Kewanee-Ross Corporation
o~.
KEWANEE, ILLINOIS
13
*
type C 1 5 psi steam or 30 psi water
1,750,000 to 10,200,000 Btu
Kewanee Type "C". with its corrugated Croun Sheet, has become America's most popular boiler tor heating large buildings. It tills a Jcnmtc need tor a completely dependable, fast-steaming boiler designed for restricted space. The follow me fea tures tell why.
ratings* mechanically fired --oil, gas or coal
A Capacious steam space presides room tor
large reserve.
3 Expansive steam disengaging area is un
broken, eliminating turbulence at the water !.a.- o-J keeping wet steam rrom tne mams.
C Rear combustion, chamber, an m .-ni r .,-r
of the firebox, concerts anv unhurned rue! : before reaching tin-tubes.
0 Crown sheet of heavy flange -tee! I- ~u a.-:!
massive corrucauuns. .ulJinc -trtnuth .m,: nr atuMliv
doubling the
inc surtaec i\cr the -. -\-t r.:-*
the tire.
E Wider, .. a ,,r combustion chamber pro-
vides sufficient air Jnd space to completeiv burn ail the fuel.
f Long gas travol through the firebox and rear
combustion chamber then forward through rhe ii.wcr tubes then again to the rear through the upper :ubes. holds the gases in the boiler until ail u^iblc heat is picked up by the boiler's water.
0 Rapid circulation of water up man
'.,-e
water legs .it sides, front and rear and between *r.e
widely spaced firctubes prevents sediment rr* ' aa*
ing and permits steam bubbles to be swept up u -- cmv
... an important factor that makes the T\ pc C ' i
very quick 'Steamer."
H Heavy steel base .b>enibled with -t staunch cast
iron posts.
J Cast doors are extra heavy, and -nsul.red to k*ep heat mside die boiler.
Iptc/fu'M/ons j nd data ire un >r /on 'tc-irdin% band-nrej , .</ :
chum.-firtJ :h ''(.ir,st Kcu./ue
boiler number
S8( rating--n'eom radiation --water radiation. ^8tu per hour. --ire am oer hour--2 1 25 F
581 net rating--steam --water --fiu oer "our
firing rate oil gph* --gas 8tu per hour
heating surface `S8I nun) furnace volume (S8i mini furnace height (S6I min)
firebox volume above mud ring safety valve capacity
sq ft tq ft 1300's
lb
. tq ft tq ft '000'.
1000`S
sq ft Cu ft ft.in.
cu ft lb steam per hr
7HO
7290 1 i 660
1750 1800
6000 9600 I 440
22 3280
429 52.1
?-8V4
67.4 Ills
7181
3500 13600
2040 2'00
7000 1 1 200
' 680
26 3830
500 60.8 2-10
77.8 2500
'Fuel burning rales bated an 150,000 Btu oil.
nn
7183
'0330 12150
16520 , 19440
2479
2916
2560
3010
8500 13600
20*0
1 3000 ; 16000 1 2400
31 4650
60S
1 1
I
73.8 j 2-1 !'/l|
37 5460
715 86.8
3-1'/j
90.5 j 134.4 3040 1 3575
7184
15180 24280
3643 3750
12500 20000
3000
46 6840
893 108.5
3-4'/4
'29.4 4465
7185
18220 29150
4373 4510
15000 24000
3600 * 54^
8200
1072 130.2
3-7
168.4 5360
7L86
21250 34000
5100 5260
17500 28000
4200
6* 9560
1250 151.8
3-10
193.7 6250
7187
24290 38860
5830 6010
20000 32000
4800
73 10920
1429 173.5
4-0%
218.3 7145
7188
30360 48570
7286 7510
25000 40000
6000
91 13670
1786 216.9
4-6'/j
302.2 8930
7189 .
36430 58280
8743 9010
30000 48000
7200
1 10 16400
2143 260.3
5-0Vj
377.4 '0715
7190
J2520 58000
0200 :i o 1 5*00 0 8 40 0
; ~? IW22
303 6 5-6
433 1
Standard equipment--front and rear bate poneli hove B'/i x 11 Vi in. deonout opening. Wgjnout plug tockef wrench with extra tet of gaskets; flue cleaner with handle. Manhole furnished on boilers 7182 and larger.
Standard trim, steam only--Safety valve, steam gage with jiohon and cock- water column with wottr-gog* gloss and three gage cocks, choin operated an 7136 and larger.
14
ZZ------------------------- c------------------------ H
dimensions and data (feet--inches)
boiler number
A--boiier width.............. B--DOiler meil length
C--ooiier length overall D--ooiier height E--*aser line height
h---wafer column height G--steam supply ne*ghf. H--smoke Outlet height
J--steam supply K --safety *aive tn-- l ft ,n. surface blow-off N--refurn height
O--fireoox--width.
P---
--*engh
R-- --neignf
1--ease--wdth U-- --length, V-- --meignr
W--smoke Outlet o-ometer . *--front smokebox depth... Y--'ear smokeod depth
AA--foundation- width
6B--
--length
PF x GO--firedoor opening in boiler width % height
HH--centerline blr to flredoor opg JJ--height doors from bottom boiler KK^-opened firedoor a boiler
22--tube reoiocemenr space
breeching diometer--one boiler
stack--diameter............... --neight . ,
breeching diameter---two boilers.
stock--diomefei . --neight
.... ..
steam supply size. return size
Outside Svrfoce to cover
sq ft
approximate weight
lb
7180 '
4-0 7-2ft 9-4'/, 7-8'/, 6-7'/,
6-4 8-1 6-4ft
1-6 1-2 1-0 1-6
3-6 6-8 2-10
4-5ft 7-4'/, 1-2
2-0 0-1 1
1-3
3-6 6-0
0-3'/, 0-8 1-tOft
6-5
2-0 1 -9 50-0
2-6 2-4 60-0
0-8 0-4
153
6700
7181
7182
4-0 8-5 10-7
7-8'/, 6-7'/,
4-6 7-8 9-11
8-10 7-7
6-4
8-1 6-4'/,
7-3ft
9-2 ft 7-4
1-6 1-2 1-0 1-6
3-6 7-1 0ft 2-10
1-6 1-2 1-6 1-6
3-1 1 ft 7-1 ft 3-1 ft
4-5ft 8-7 1-2
4-1 1ft 7-10
'2
2-0 0-1 1
1-3
2-4
1-0 1-3
3-6 7-2ft
3-1 ! '/, 6-6
1-4 * 0-1 1
0-3'/, 0-8 1.10ft
0-6 0-8 1-IOft
7.7 6-i a
2-0
1-10 60-0
2-4 2-0 55-0
2-7 2-5 70-0
2-10 2-8
65-0
0-8 0-8 0-4 0-4
170 '92
7600
8800
*'50 lb American Standard Flange.
''Includes front head and smokebox.
7L83 | 7184
7LBS
4-6 8-11 ft 1 1-2 ft 8-10
7-7
7-3 ft 9.2ft 7-4
1-9 1-2 2-0 1-6 3-1 1 ft 8-5 3-1 ft
4-1 1 ft 9.1ft 1-2 2-4 1-0 1-3
3-1 1 ft 7-9
0-6 0-8 1.10 ft
8-1
2-4 2-2 65-0
30 2-10 75-0
0-8 0-4
214
10C00
5-0 9-2 ft 1 1 -6ft 9-7 ft 8-4ft
5-6 9-llft
l 2-3ft 13-0ft
8-7
8-1 10-0
8-0 ft
I -9
1-2 2-0 1-9
8-3'/, 10-4 ft
8-3ft
1-9
1-2 2-0 1-9
4.4ft 8-7 3.4 ft
4. 1 0 ft 9-4 3-7
5-6 6-0 9-5 10-2 1-5 '-5
2-6 2.7 1-0 1-0 1-4 1 .4
4.4ft 8-Cft
4-1 Oft 3 9 ft
1-8 x 1-0
0-4 ft 0-8 2-2ft
8-4
0-7ft 0-8 2-2ft
9.1
2-6 2-4 65-0
3-4 3-1 75-0
2-7 2-5
r70-0
3-5 3-2 80-0
0-8 0-8 0-4 0-4
2*0 275
1 i 800
1 3600
7186 1 7187 1 7188
6-0 9.3ft 12-1 ft 10-10ft 9-5
9- 1 ft 1 1.2ft
9-Oft
1-9 1.4 2-0 1.9
5-5 8-8 4-0%
6-6 9-6 1-5
2-1 1 1.2 1-8
5-5 8-1 ft
0-6 ft 0-8 2 5 ft
8-3
2-1 l 2-7
65-0
3-8 3-5 75-0
0-8 0-4
297
1 5300
6-0 10-6'ft 13-4V, 10-10 ft
9-5
6-6 1 1 1 1 ft
U.9ft
n-6 9-1 1
9-1 ft 1 1-2 ft
9-0ft
1 -9 1 -4 2-0
-9
9 - 7 ft 11.11
9.7ft
1-9 -4
2-0 1-1 1
5-5 9-1 1
4-0 Va
5-10 1 1-4
4-6 Vt
6-6 10-9
1-5
7-0 12-2
1-5
2-1 1 1-2 1-8
3-3 1-2 1.8
5-5 I 9.4ft
5-10 10-9'A
:-M x 1.3
0-6 ft
0-8 2-5ft
0-10 0-10
2.5ft
9-6 10-1 1
2-i : 2-9'
75-0
3-3 3-0 90-0
3-1 1 3-8
85-0
4-2 3-11 100-0
0-8 0-4 '
0-10 0-6'
322 387
17000
20100
7U9 | 7190
7-0 f i:-4ft!
1 4-2V, 1 3-6ft M-9'A
i 1-6 13-11 ft
U.5ft
1-9 4
2-0 2-3
6-4 : o-8 ft
5-6
7.6ft 11.7
'-9
3-5 1-2 i.a
0-4 ' 0- 2 'A
70 13.1 ft 15-1-ft ' 3-6ft
; i-6 i 3-1 i ft
2-0 4
2-0 2-3 6-4 i:-sft
7-6 ft 1 3-4
3.7 1-2
6 4
1 ! .M if.
1.1 0-10
2-5ft ' 0-4
3-5 3-2 80-0 4-6 4-2 90-0 0-10
23200
-1 0-0
3-7 3.4
4-8
4-4
0-1 0
476
Kewanee-Ross Corporation
KEWANEE, ILLINOIS
is
9
5000 series
1 5 psi steam or 30 psi water
1 5 sizes ... 1,020,000 to 10,200,000 Btu
The Kewanee "5000" low pressure series is rapidly grossing in popularity for heating large buildings when speuneations or restricted budgets require an economical boiler of unques tioned durability and efficiency.
"5000" is an electric welded series, in the fabrication of which all modern practices and improvements in welding have been combined to produce a completely dependable product ... a boiler worthy of the name Kewanc-e. . In design the "5000" is similar to that of the famous heavy-duty Kewanee "^OO" and has all those outstanding characteristics which for some 85 years have made Kcw.incc Boilers different and better.
Extra large and extra high fireboxes provide ami'le 'P ice and air in which the burning fuel can mix with oxygen to complete the combustion process without waste or fuel Longer travel of gases . . . from the lire chamber through the lower bank of tubes then through the upper tunes to tne exit chamber at the front . . . gives the boO-r's water a
chance to absorb and use all the heat that is atc-d in the firebox.
Circulation is rapid through generously . .... water legs and between the well-spaced fire tubes, sweeping the myriad of steam bubbles up into the capacious steam chamber with out undue commotion. The disengaging areas at the w ater line are unbroken insuring a constant supply of drv steam.
As is true with all Kewanee Boilers the "5000" can be fired to produce 50^ and more than its rated capacity and continue to operate at full efficiency.
Spicincjttoni jnd djta are shuin for mtchjnt.jlly-nrgJ boiler;, f :
tton 'e^urjtni o^nd-ftred : al types i
;Ke urest ktuavi r >:p>i
-
ratings mechanically fired-- oil, gas or coal
bailer number
$31 rating--iteem radiation
.ia ft
--water 'adia'ion
so ft
--Btu per hour
' 300's
--i'eom per hour--21 2 F ,b
SSI net citing--iteam
SQ ft
--water --Btu per hour.
sa t '000's
5176
1250 6800 1020 1050
3530 5600
960
firing rote--oil gphV --gas Btu per hour.
13 1000's 1910
healing turfoee I5BI mm). . , . furnace volume <$BI mm} fumoce neight (5BI min). . . .
IQ ft CU ft ft-in.
250 30.4
2-6
fireBox volume above mud ring Cu ft
additional fumoce height for stoker
'561 ni|"
ft-in.
safety va've capacity lb steo m per hr
44.3 1 250
5177
5171 \%\7}S 3110
Sill
i860 7770 1 1 66 1 200
5470 8750 1313 1350
6080 9720 1459 1500
7290 1 1660
1750 1800
8500 1 3600
2010 2100
4000 6400
960
4500 7200 1080
5000 8000 1 200
6000 9600 '440
7000 1 1 200
1480
15 2180
<6 2460
18 2740
22 3280
26 3830
286 34 8
2 6 Vj
322 39 1
2-7V4
3587* 2-7%
429 52 1
2-8J4
500 60.8 2-10
44.3 49 6 54,5
60.2
66-6
1430 1610 1790
2145
2 500
5183
5183 5184
5185
5U6
10330 16520
2479 2560
12150 1 9443
2916 3010
15180 24280
3643 3750
18220 29150
4373 4510
21250 34000
5100 5260
8500 13600
2040
1Q0C0 1 6CC0
2400
1 2500 20000
3300
1 5300 1 7500 24000 28000
3400^ 4200
31 4650
37 5460
46 6840
8200
64 9560
608 73 8 2-1 1 Vi
715 86.8
3-1 Vj
893 i 38.5
3-4 >/4
1072 130.2
3-7
1250 151 8 3-10
90.6
103.2
1 17.5
123.4
137.5
3040
3575
4465
3-3 5360
0-5 6250
5187
24290 33860
5830 6010
mi
30360 48570
7286 75'0
5189 136130
58280 8743 9010
' 5190
42500 63003 13200 13510
20000 32000
4800
25000 40000
6000
300CC 48000
7200
3500 3 ioo :o
i 3403
73 10920
91 13670
l 10 16400
i 27 19*23
1429 173.5
4-0%
144.0
1786 216.9
4-6'/5
197.1
2113 j 2500
260.3 1 323 6
S-Q'/j
tnrr 222.0
0-10 71*5
0-6 8930
0-10 10715
' 2'0 3
* Fuel burning rates based on t 50,000 Btu oil. " Represents distance below bottom of water leg thof hearth mvst be set for S6I minimum furnace volume and height.
Standard equipment--Front and rear bose panels have 87i x 1 1 Va in. ooenmg and cover plate, hackstand except 5176-77, flue cleaner and handle. Manhole furnished on 5192 and larger. Washout plug socket wrench with extra set of gaskets.
Standard trim, steam only--Safety valve, steam gage with tiphon and cork cncolumn with water-gage glass and three gage cocks, chain operated on 5' 33 c-i-j larger.
16
K
--Y
8 MANHOLE
--Z --zz
I1 >
(
(
NOTE: Ust dimtniion drawing on this attac.ied Ry-thaal. Oo not uio drawing printed bantalh.
dimensions and data (feet--inches)
boiler number
A--boiler diameter 8 boiler length C--boiler neight
water line heignt
6--water column height P--nteom supply height G--smo*e outlet height H---reor stond height
J--jteom supply K--saferv vqiv* *4--! 7, in surface blow-off N--<eturn ne-ght
0--EirebOA---width
P --length
ft--
--neight
` -- eose-~width J-- --length . V-- --heignt
w--smoke outlet--length X-- --width <-- --(ocotion Z--rear door clearance, mm
AA--found a*ion--width
33--
--tengfh
CC--'ear stand
"'efloor style
te * GG-^tedoer opening in Doder width x height
HH--centerline blr to Aredoor Opg JJ--neight doors from bottom boiler <*C--opened Aredoor to boiler
ZZ--tuoe replacement toace
bteechmg diameter--one boiler slack--diameter
--height .
breeching diameter--two boilers stack--diameter
1 height
'steom supply site return s<ze
*'0\rtside surfoce to cover
sq ft
approximate weight
lb
S176
3-6 7-3 6-9 5-'0
5177
3-6 8-0 6-9 5-10
5178
3-6 fl-1 1
6-9 5-10
5179 l 5180
-73 9-10
6-9 5-10
4.0 9-9 7-2'/j 6-1 7,
5-8 7-1 5-n 3-2
5-8 7-1 5-n 3-2
5-8 7-1 5-n 3-2
5-8 7-1
5-11 3-2
5-11 7, 7-7 6-2 3-2
' -4 1 -4 1-5 1-5
'-5
2-9
2-9 2-1 1
2-11
2-1 1
1-6 1 -6 1-6 1-6
1 -6
1-6 ' -6 '-6 1-6
1 -6
3-01/, 4-2 3-6
3-07, 4-2 3-6
3-0`/i 4-8 3-6
3-07, 5-> 3-6
3-67, 4-8 3-8
3-11 7, 3-1 l Vi 3-M /, 3-M 7, 5-0 5-0 5-6 6-0 1-2 1 -2 1-2 1-2
4-57, 5-6 1-2
2-8 0-9 0-67, 3-6
M 0-9
0-67, 3-6
2-8 0-9 0-67, 3-6
2-8 0-9
0-67, 3-6
2-10 0-11
0-77, 4-0
3-0 3-0 3-0 3-0
3-7 3-7 4-1
4-7
2-6 2-1 1
smgie frame & doub'e dm
3-6 4-1
3-3
5181
4-0 r. i
7-Vh 6-1 /,
5-1 P/, 77 6-2 3-2
1-5 2-9 1 -6 1-6
3-67, 5-2 3-8
4-SVj 6-0 1-2
2 1 0 0-1 1
0 7 Vi 4-0
3-6 4-7 4-3
5182
4-6 1 1-1
7-87, 6.5'/i
6-37, 8-1 6-7 3-2
2-0 3-6 1-6 1 -6
4-0 7, 6-0 3-10
4-1 IVi 6-10
1-2
3-4 1-3 3-3 2-6
3-1 '/j 5-5 3-2
5183
5184
5115
5186
5187
4-6 12-9
7-87, 6-57,|
5-0 i 3-7'/:
8-4'/, 7-0
S-0 15-3
S-4'/i 7-0
5-6 14-5'/,
8*9 7-2
5-6 16-0'/,
8-9 7-2
6-3'/, 8-1 6-7
3-2
6-10 8-9
7-1'/, 3-4
6-10 8-9 7-1'/, 3-4
7-0 9-1 7-3'/, 3-2
7-0 9-1
7-V/, 3-2
2-6 2-6 1 0-9 2-9 1 ' .3 4-0 4-0 12-3 4.3 5-3 1 -6 1-6 1-6 1-6 1 -6 I -6 : -9 1-9 1 ? 1 -9
4-0 V, 6-13 3-10
4- 1 V; 7.3 , 2
4-S'/, 6- 10 3-M
5-6 7-9 1-5
4-5'/, 7-2 3-M
5-6 8-1 1-5
4.11 y, 7-2
3-1 1'/,
6-0 8-1 1-5
4- 1 '/, 7-6
3-1 1 7,
6-0 8-57, '5
3-4 3-8 3-8 4-3 4-3
1-0 i 2 1-2 1-3 1-3
0-8
3-9
3-9
0-9'/,
3-9'/,
7-6 2-9 2-9 3-0 3-0
3-' 6-3 4-0
4 - 4 '-j 6-4 4-3
4-4'/, 6-8 6-3
i-l O'-, 63 5-3
i. ; -i
7 3 7, 6-3
- 9 it and tt smgie t'ome and door
5188 j 5189 ! 5190
6-0 16-3'/,
9-3 7-9
6-6 1 >7-57, j
9-9 1 3-0
0-6 19 g
50
7-7 9-77, 7 9'/, 3-2
7.10 10-17-1
3 ?% 3-2
" 3 0-'
i ; 7:
7
! 2-0 6-3 20
1 .1 1
i 2-3 4-i i
-..0
1
.i :
57 -. -j
5-5 V, 8-6 4-2 7,
6-6 9-5'/, '-5
5-1 `/, 8-6 4-57,
7-0 9-57, -5
90 4 i'-i ?1 9.'. 7',
4-6 1 -7 0-1 1 '/, 3-3
5-0 1 -6 3- 1 3-5
3s
5-4 3- 2'-, 6-0
6-7 ,
8-: , i:
one 2 3 Vt x 1 -1 '/j
0-87, 0-8'/? 0-87, 0-87, 1 -8 1-3 1-8 i -8
3-6 6-3 7-2 8-1
1-7 1 -5 40-0
1-3 1-6 40-0
! -9 1-7 45-0
M0 1-8
50-0
2-1 i-l 1 50-0
2-2 2-0 50-0
2-3 2-1 55-0
2-4 2-2 60-0
0-6 0-6 0-6 0-6 0-4 0-4 0-4 0-4
- 15 i 25 ' 35 45
1500 5000 5400 5800
0-J7, 0-8 M3/2
7-8
Ml 1 -9
50-0
2-6 2-4 60-0
a-8 3-4
1 60
6600
iwb 1 - 4 O-ll
O-3/i 3-8 1 ' 0,/i
3-6 0-8 1 ' y/i
9.) 9-0
: ; M3 55-0
2-2 2-0 50-3
2-7 2-5 65-0
2-10 2-8
60-0
0-3 3-8 0-4 0-4
i 80 702
7400
3500
0-6 0-8 MOV,
10-8
2-2 63-3
3-0 2-i 0 70-0
0-8 0-4 227 9600
3-4'/, 0-8 2-2'/, 13-97,
2-6 2-4 65-3 3-4 3-1 75-0
3-8 0-4
257
moo
two 1 -1 X 1-0
0-4'/, 0-8 2-2,';
0-7'/, 0-8 2-2'/,
12-10
2-7 2-5 30-0
1 1 - 8 '/i
2-9 2-7 73-0
3-5 3-2 90-0
3-8 3-5 80-0
0-8 0-8 0-4 0-4
290 305
1 2800 U400
3-7 Vi 0-8 2-2'/,
'3-3 7,
2-1 l 2-9
35-0
3-1 1 3-8
95-0
3-8 0-4
332
16000
wo 1 1 ' * 1 3
0-6 7, 0-8 3 -S'-,
1 3-77,
3-3 3-0 85-0
3-13 03
2 57,
14 4
3-5 3-2 9) 2
33 -1
: 7.?
:7 i.x ' 350
4-2 3-H 95-0
*6 4: 130-3
4i i4
0-10 3-6*
0-10 3-6*
3
375 420 4 66
19200 22330 25233
* 150 lb American Standard Hang*. * includet front head and smpkebox.
Kewanee-Ross Corporation
KEWANEE, ILLINOIS
17
Square-Heat type "R" boiler
l lsiiei
. 216/000 to 1,200,000 Btu
900 to 5000 sq ft-steam : f
1440to8000 sq ftwater
, Never before has; a .boiler been built with the ver^ satility;-'ofr;Kewanee 'Square-Heat. It is `ideal for medium "size buildings ; of all. types or';,for. small factories;- It burns ariy fuel and a change, from une' to another,, or" from mechanical .to hand tiring,' or back again, can be made quickly and, inexpensively.
These, features indicate .why Square-He.it' packs so much heat'generating ability in .comparatively small space.1'
A ; large, , high steam space ashurt.'s. ample,re*,
, - - serve'of;dry steam.
; - *;
B. Reversible smoke box may be-i^v-d '.vith nthef.1 . top or-.rear smoke, outlet.'. ,, ; >*
longer gas travel*. . . to the tc.it'. :ixn ;he
. front; and to- the^fear-again gets-all the !*cat into the
boilers-.water. />-
-;
D Spimier blatlos iri oil or .gas; boilers .< $R*i to $)
- .-/Swirbhot gases, against tube wajls' assuring maximum
r - ''beat, transfer. .
k.
.i' '
Insulated/sturdycast doors are precision
^groundnrfof permanentvgas tight fit: Observation open- '
,ing has adiustable hinged cover; for secondary.over
fire air.^
* . V1 { t-
\ Lorgo^ hi9h firebox provides ample-space and air'for, complete, economical burning ut the futf.
Rapid circufatiori in wide free waterways
steamybiibbles up.',,,without commotion, i<\ unbroken
'release-area at waterline. <
r.-
Shell of extra heavy high quality Vteel adds' strength.
Extra substantial steel base, can be reversed
for bring from rear.
", i -
-Extra-higli bases (20.' and'50. in!-)' for mcefun-
';ical* tiririi; instead of-sVandatd la ;in.' base, are avail
able. if ispecitied..;at extra cost.' j!
s " ' - .
S&t-.aii
jre *?'; ,r. *,huu:
fr<: F. >r lb'-
etjrJir.i Aj
e-i .* r<S ,r..uit
'ih Te jrr */ Kt u umt uprisYntattvt.
ratings * mechanically fired*--oil, gas or coal
bailer numbar
5BI ne roting--steam.............. --water.............. --Btu per hour, . ..
1000's
fifing rote--oit gph*..............
1
--gas Btu per Hour ... 1 1000's
--mtoker**
l >b per tir
heating turfare (SBI min) . . . . . . . 1
to ft
furnace volume (SSI mm).........
safety valve capacity.......... lb steam per hr
* fust burning rates based on 1 40.000 Btu oil.
3RI
900 1440
216 3.3 405 36
53 8.2 265
JM
1100 1760
264
3.7 495
44
65 10.0 325
3R3
K ! | a"
1300 2080
312
4.3 585
52
17 11.8 385
1 1500' - I j 800
i 2400 , 1-2880
360 ; j .432
" 1-6.0 ' 5.0
675 I BIO
60 1 71
, 88 -
; 13.6 !. 440 ` 1
106 16.6 530
* Based on coal having 12,000 Btu per lb as fired.
3R4
1 3*7,
- 3M f
3R10 f n
3*11
2 200
3520 528
* 7.3 990
38
-129 20.0 645
' : 26ob'V
' ! 4160.1,.! .,624 :'
. 3000 4800 720
'3500 5600 840'
4000* | ` 4500
- n 6400 4 7200 ,'' 960 ' j1 ioao :
. 8.7 ' : - 1170
J 04
'
10.0- - ' 11-7 1350 1575 . W .120 ' . ' 140
13.3
15:0. :
. 1800 v. 2025 '
* 160- - * ' l 80
k ' V 53
23.6, I -:765
, 177 , 5 206 'r27.3'* ** > 31.8 .
.. '885 ' \ 1030 . '
236 -I 265 36.3. 1. 40.9 '*
1180 r- 1325
5000 8000 12:3
. ;so7 .'2250
?00 *
- 294. ' . 45.4.. f 470
, -. r' - - -V ' "
Mote 1--Standard base it 14 in, - high. Boies of 20 and 30 in. height available for mechanical firing at additional cost.1
Note J--Boiler ratings do not include allowance for heating domestic water by indirect coils. When the hot water demond is added to the heating load.for more than ten minutes in any hour, an allowance of 4 sq ft of steam radiation or 6.4 sq ft of water radiation must be added for each gallon of wafer (heated.
Standard equipment -ft- cleanout plugs, 3R1 to 3*1!. 8 cleanout, plugs. ]R1 ?. Sochet wrench with extra set of gaskets. Steel base completsi'with 8 x 14An.' covered opening. Rue and soot scrapers with handies. Spinner blades for 3R1i to 3R8 Oil or Gos boiler* my
Standard trim, steam---Water gage, two.'compression gogo cocks,' steam .9090,
pop safety valve.
- ; j* ' * l . - ' '
Watev^-Combinotion oltitude 9090 and thermometer only.-
'
18
dimensions and data (feet--Inches)
boiler number
A--soner wd!fi overall ... --acket width
8--pone' length -- :aener length . . ......................
C*--OO'ier he>gnt
-- acitel height from floor . . . wafer nne height.
t--s'eo-i or worer iuppiv neight c---nmcve owiiei height G--ueam or water lupply M--neate- connection height, each ude i~^0'i conneciion height < -- e'.rn -e-git
u--- nrecjcs----wfllh
N--
---ength.
0--
--height
P--oose--w.ath t } 4 m. hign. 9-- --engrh
>--jmoe o^riet--width T"-- --length . U--imokebo* overoll V--iTione outlet locution
floor >0 oorom of fluedoor *--ooened firedoor to boiler. Y--*oor to eotrom of fi'edoor
--Aredoor opening m Boiler--width .
--height
oreecnmg diameter iwhen flattened, fill ova! imote necu) .
Chimney--diometer --- ne.gni
ileom lupply me return me Ha*r connection size
Outiide lurtace *o sever, jniacketed. opprosimaie weight, umacketed
sq ft ib
3R1
2-6 2*7 2-6'/: 2-9 '/, 5-6 5-6 '/: 4-7'/,
5-6/j 3-8'/j 0-10 4-OVt 4-9'/: '-5'/:
2-0 2-1 /: 1-9'/:
2-3'/j 2 10'/:
0-9 1-4% m 0-7'/:
2-10 1-9'/: 1-7/, 1-4
0-1 1
1-2 0-10 3Q-0
0-4 0-3 0-2'/j
38 nsoo
3R2
2-6 2-7'/: 3*0'/j 3-3 '/% 5-6 5-6'/: 4.7'/:
5-6'/: 3-8'/: 1-0 4-0'/l 4-9'/, 1 5'/,
2-0 2-7'/: 1-9'/,
2-8'/, 3-4'/,
0-9 1-4% 1-1 0-7'/,
2-10 l-9'/j 1-7'/, 1-4
0-1 1
1-2 0-M 35-0
0-4 0-3 0-2'/,
43 1 650
3R3
2-6 2-7'/j 3-6/: 3*9'/: 5-6 5-6'/: 4-7'/,
5-6'/, 3-8'/: 1-2 4-Q'/: *-9'/, 1-5'/,
2-0 3-1'/, i .9'A
2-8'/, 3-i 0'/i
0-9 1-4% 1 .1 0-7'/,
2-10 1-9'/, i-7'/: 1 -4
0-1 1
1-2 1-0 35-0
0-4 0-3 3-2'/,
48 1800
1JO lb American Standard flange. 6ght % In. bolts, 9`/j in, bolt circle.
3R4
2-6 2-7'/, 4-0 'A 4-3'/, 5-6 5-6'/, 4-7'/,
5-6'/: 3-8'/, 1 .4 4-0'/: 4-9'/, 1-5'/,
2-0 3-7'/, '-9'/,
2-8'/, 4-4'/,
0-9 1-4% 1-1 0-7'/,
2-10 1-9'/, 1-7'/, 1-4
0-1 1
1-2 1-0 40-0
0-4 0-3 0-2'/,
53 1950
3RS
2-10 3-0 3-6*/, 3-9'/, 6-1 6-2 5-2'/,
6-2 4.1 1-2 4-5'/, 5-4'/, 1-6
2-4 3-1'/, 2-2
3-0'/, 3-10'/,
0-1 1 '/, 1-9'/, 1 -3 V, 0-8%
3-2 I-9'/, 1-9 1-4 0-11
1-6 1-1 35-0
0-4 0-4 0-3
58 2250
3R6 1 3R7
2-10 3-0 4-2'/, 4-5'/, 6-1 6-2 5-2'/,
6-2 4.1 1-5 *5'/, 5-4/, 1-6
24 3-9 2-2
3-0'/, 4 6'/,
0-111/a 1-9'/, 1-3'/, 0-8%
3-2 1-9'/, 1-9 1-4 0-11
2-10 3-0
4*10 5-1 6-1 6-2 5-2'/,
6-2 4-1 1-7 4-5'/, 5-4/, '6
2-4 4-5 2-2
3-0'/, 5-2
O-ll'/j 1 9'/, 1-3'/, 0-8%
3-2 1-9'/, 1-9 1-4 0-1 1
1-6 1-2 40-0
0-4 0-4 0-3 65
2475
j .
1 |
1-6 1-3 40-0
Q.4 0-4 0-3 73
2725
3R8
2-10 3-0 5-7
5-10 6-1 6-2 5-2'/,
6-2 4-1 M0 4-5/, 5-4/, 1-6
2-4 5-2 2-2
3-0'/, 5-U
0-1 1'/, I-9'/, 1-3/, 0-8%
3-2 l-9'/j 1-9 1-4 o-l 1
1-6 1-4 45-0
0-4 0-4 0-3
82 3000
3R9
i mo
3-5 3-7
4-8 4- J 1 6*10 6-10'/, 5-10'/,
3-5 3-7 5-4 5-7 6-10 6-10'/, 5-10'/:
7-2 7-2
4-6'/,
4-6'/,
1-4 1 -6
4-10'/,
4.10'A
6-0'/,
6-0'/,
1-6 1-6
2-1 ? r~ 2-m
4-3 4. 1 1
2-7 2-7
3-8 3-8 5-0 5-8
1-1'/, Ml'/,
1-6'/, 0-10%
M'/, Ml'/,
1-6'/, 0-10%
3-7'/, 2-3 1-9'/, 1-8 1-0
3 7 y, 2-3 1-9'/, 1-8 1-0
1-8 1-4 35-0
0-6' 0-4 0-3
82 3375
1-8 1-5 40-0
0-6* 0-4 0-3
90 3650
3R11 | 3R12
3-5 3-7
6-0 6-3 6-10 6-10'/, 5-10'/,
3-5 3-7 6-7
6-10 6-10 6-1 0'/, 5-1 0'/,
7-2 4-61/, 1-8 4.: oy,
6 0 /, 6
7-2 4 - 6 '/, 2-0 J-'1.'1/,
6-0 /, : -d
2-1 1
2-1 1
5-6'/, 2-7
6-2 2-7
3-6 ~ 3-3 a-,
1-1'/: Ml'/,
1-6'/, 0-10%
M y, Ml/,
-6/, 0-1 0 %
3-7/, 2-3 1-9/, 1-8 1-0
3-7/, 2-3 1-9/, 1-8
-0
1.8 1-6 45-0
0-6* 0-4 0-3
99
3850
1-8 1-6 50-0
0 6' 0-4 0-3
1C7 4200
Kewanee-Ross Corporation
KEWANEE, ILLINOIS
19
!.r.,, ~r i-
Round type("R"
4;sizes, v . .. 96,000 to 216,000 Btii 40G.toy00sqft steam 3,r'.r 640 to l 440 sq ft water
'!l , Hicher comfort st/ndnrds, for. himei .with m. .Jvrn deV:, su'ns tejturini; cn Limed window are-is .'.rid in r.indi. tvpus.
3. ' tarf.more Tniit-anJ 'w'ail arvus.v *: ,.im;*`*<c .i ua:Kr: iKutir:.: : , problerri'on :lie`Sailer. This ` prohUm; :<, nxt. c-'mpLK-iy hv
Kcwance Round, 'R." ,^
^ ',;Sturdilv^ built'I't heavy ,it -tii.' n' ;1-. S V
{nuriv.extra'vejrsy Features unus'u.il .`ependahslit'. ; . cc*-rv
.'iiiy. . . v(w;ith i capacity- to handle.l.irav
. !y
\ Capacious steamspace holds a
.':oc:^ n
s \. -steam, tor",unusual demands i' . .yfKy.> ii K. ,:;:J
"R" can be* fired above its .rated capacity ..nd .v- rv;r...v'
to operate.Avitn efficiency:
':
% Two-pass tubos, provide 'longer travel - the ':u\\ , aascs rctainin^them m the bi,iler lihtti ..ii : ':'k- :k..:
is transferred to the'water.,'Spinner Blades '.v:r! gu'es". 4. -.againsc tube, walls assuring maximum iK.it ::..;''t\r.
Well insulated sturdy cast iron doors. Rue
1 door and'tfarne are precisinn uround and
with
i:' ' asbestos :rope' casket tor a permanent gas, :;g'ir 'rir.
0 Large; high firebox proNides 'urhcient 'pate for ` i gases'to mix;with oxygen and burn completely.
: ' shell; of extra heavy steel btiiler plate, is cyerlacihsly ' welded inrb.,one'piece,, ready .to set on its ha^e.
rrWide, free"waterways assure .r.ip.d i-i:^uiar!..n.
sweeping steam bubbles quickly and with* ut o .rtn-ti- n upto-the .'unobstructed release areaar the a ati.-r -imr -'
O'! /Heavy 'Steel base^can- Yfake-jt/'
and.
jJacket/.base may beswung arounJ to';j:v tr*>m'rr.'nr.
/``C. rear, sideor.'anV angler1 V,)'
S'1- '
, ; >. -t>i ..*!, -* \
! ; Domestic hot water coil,>raiaJ in -bronze t:t*
. ' ttinus: ;ind .mounted tm1.,steel-plate Wth .'h^knuiv.anl! , , rubber ,.ua>ktts.;*provitJcs*'.implc hot `Kvater 't-r Vitd'tn .
laundry'and hath. . * '' ** '*
. '
i .'.s< ur nr, u:J-,.; i:j .irf
ratings mechanicall y fired -- oil, gas or coal
*
, H1', ' '
1 *
boilernumbef
S8l net rating .connected radiation plus not water load)
---steam or vapor
.. >
--water
--Btu per hour
* ^
*a ft ,
*9 Ft ,i :oo'i
firing rote--oil gpn* . --gas 8tu per hour --^TOker**
healing surface furnace volume firebox volume, for stoker firing safety voive, capacity
,
loob'i
- !b oer nr
sq fl
Cu ,,
Cu ft
ib fleam aer nr
X t73*
400., 640 ,96 .i , . ' h 180'
ii 24 44 ` 3.7 1 20
* Fuel burning rates based on 140,000'Btu oil. ** Based on coal having 1 2,000 Btu per !b as fired.
` !73d
-J
I7J7.'
'11 '.'"`.ssoi,,
, , '880*
'
' i ;s
-
; '
700
*.
.1120 * ' i , : :
.'68, ,, . *,
'
t ; ' . .90 3 ,, 440 ' ..
216.
*' -
- ;T ' ' *'4-248..^ lr.\
; ,,315 y 28 . '
.0 3 ' 4-35
1;
->
r
5.* ,
-
54
L__________ ______________
0.9. ' 205' .
V 5*1-
* >, . l- . 3;9. ;
-it'; * -'
^' -:'5 '
, *"
` `: w
\ ' '' .
' ^37 nf furnished for s*oe' ''.Vq
`-V .r .
*, .
' IA
Standard eqwipmanf--Spinner blades Far oil or gas. Soot and fiue scrapers. V'
,
Standard trim, stearr--Compound team ond vacuum gage, water qage. wo 9age'
cocks, V* in. saFety voive. The,extra 1 Vt in. topping in top of boiier moy-'oe .sed tor
' pressure control.
.<* .
.*
|l Water-- Comb.nation -altitude'gage and thermometer.
' "
' ' 1,
|w
- ." , * ' ,
' v.`* ' !
20 ' 1
.
' H/ ,
-------------- K
3" SUPPLY
3 SUPPLY
^ : i :o1"
' I
I i 1t
-I 2r" --
-------- B------- -
L
dimensions and data (feet - inches)
boiler number unjackeled equate jacket (o*l or gat only) round jacket
boi(e d.o-neter firebox--rnude diameter
--average neght
A--heig.nl overall 8--bose diameter C--water une height D--o'e' cod connection he.gnf
--jmoxe ovtlet--height
P-- --diameter
O--
--'o ocner center
H--'ear clearance--oo'ier a wgd
J--Poor o oottom zi rr-dosr
K--row-id ocket diameter
-- \Qua'e 'ocuet--wta**>
l--
--<engh
m--
--front clearance
N--mi.-nym burner tube length .. . , O--comowston chamber--length, i-iude.
--width, .rude
A,-.e
--height
Ovtt.de jurtcce to cover, aniocxefed approximate weignt--umacketed
--acketed Q --OCketed J
i
! '
>Q ft ! !
lb i ib |
* Coil connection uiei: 1 m. pipe for two owtletj, J/4 m pipe for four o ctets.
1734 I734MQ I734J
1 -M % '8
i i3
A-6'/: 2-2 3-3 3-5V,
3-3V, 37 t 61-* 3-6J'i ' 7W1 < - ' J/4 2 !I 3 ai'j ' - :
3-8 C-1 ! ' y/} ;i. i
33 0 24
800 ' 30
335
t 735 1735MQ 1735J
2-3`/i !M
2.0
4-IQ 2-5`/j
3-1 i
3-6,/j
3-3'72 :.5 i.ay?
0-7% ' -3
2.5'4 3-3 4.1 1-6
0-3 1-305 0-1 0:/:
3-8 '-0 30 0
35 920 1200 960
1736 1736MQ 1736J
2-6 '/i 2-2 2-2
5-0'/: 2 8'/] 4- 1 3-' O'rj
3-3V* 0-9 .' ! 0-7 H 5 3'/?
2-874 3-6 4-1 l 2-1
3-9 1-37: '-3
0-3 '-0
35-0
4t 11 30 1450 l 175
1737 I737MQ
2-6Vi 2-2 2-2 5-0 l/j 2 ay, 4.1 3- 31 : 3-3 i
0-7 \ ' - /:
3-6 4-1 1
0-9 ' 3 '3 0.13 1 ; . 40-3 47 i 430 1700
Kewanee-Ross Corporation
0*>na e* Amnten tod>er ft S'ondar* Seniery
KEWANEE, ILLINOIS
2t
VT510 Cottage Boiler
... oil or gas 77,000 Btu . . . 510 sq ft water
The Cottage Boiler is Kewanee's answer to the lone standing need
for a
; Heei bniier for small homes. It provide* i :p.
outomMic hneJ hoi h .in-) re.it . . with ample Joir.estio hot
water tor kitchen, laundry and bath . . at a price witk.n the
reach of modest budgets. In ns attractive steel jacket it cK.-ries a
space only .'ixb in. Though rated at ".000 Btu. it :s capable
of carrying 50'f- more than its rated capacity.
features
A Hinged double cover on smokehood provides (.Jsv .iucm )
tubes tor cleaning.
3 Tappings m boiler shell provide tor all automatic G-ntr -m
C Domestic hot water coil made in one unit. .Itiiu ;;-n!.ss . r
storage tank type, easily inferred any time through t^p \-aJ.
o Vertical tubes with Spin
walls thub assuring greater h<
: >cruh hot Hue aa^s
rune
.n>tcr without dirking ti.e Jratt.
High firebox permits tho-
transfer.
irhwtc.n or tuel and '.rid heat
f Heavy gage welded steel construction h>dn.Matu.ai:y
tested at 150 lbs. for maximum water working pressure of too lbs.
G Sturdy cast iron fire-cover plate with free r.wnuing purf-
back safety swivel for observing flame. Refractory lined :> pi.-.nt warping.
H Universal flange fits practically any fijnee mounted ui burner.
Square mounting may be provided tor gas burners
j Stainless steel combustion chamber <oUpx-up
tion of oil. Installed eaulv through nredoor opening.
>"h >
:< Insulation refractory fill-in keeps door cool and h ikr eat
inside.
Standard ecuipment--Berner mounting flange.- {Dinner blades n me eo>v tubes F*ue icrooer.
Standard trim--Combmtion altitude goge and 'hemonsttr, stamlett siee' button chamber <0' o-l-firing suppled at e`ra cast.
-jcqe cc-n.
ratings and dimensions (feet-mches!
bailor number
SSI net rating (connected radiation plus hot water load}
--water..........................
......................................... iO ft
--Btu per hour . .
1 000'*
firing rate--oil gpn*
--gas Btu per hour.. healing lurface. fi'ebo* volume. .... c"imner*--nite . ,
1 O00`i . sq ft
cu ft
--height above CL smoke cutlet smoke outlet to boiler center. water coil connection height** , , .
..
flow connection height boe--diameter top ring door clearance.
approx. we<gnt, lacketed M.
. 'b
'Fuel burning rate based on 140,000 Btu Oil. "Coil connection sites: V\ in. tankless. V* in. for storage tank.
VT510
510 77 1.1
1 44 19 2-9
0-8 * 0-8 1 2-0 0-M% 4-3 >A
4-1% 1.10 650
22
VT510-U Cottage Boiler-Burner Unit
oil fired only
Now the very efficient Kewinee Cottage Boiler (described on opposite page) is available as a Boiler-Burner Unit complete with an .ill-star cast of accessories. Built, assembled, tested and substan tially crated at the factory, this complete unit can be moved onto the job and installed with minimum time and labor.
The boiler and burner, all controls, pump, safety and relief valve, etc., are quality products ... all having "won their spurs" on thousands of installations.
Standard equipment includes:
A Air relief fitting eliminates anv accumulation if an m -:w h.i.'cr
nt system.
B Water relief valve is ASME rated to open at a pressure a 50 !b.
... an important safety (actor.
C Draft control equalizes variations in draft and saves tael
S Stack Control a safety switch that 'huts off burner m ,
t .am-
`.ion or dame failure and prevents operation until manually set.
e Theraltimeter ... a combination altitude, pressure and tem-eta-
ture gage.
F Domestic hot water coil for tankless operation raises the tem
perature of 180 .gallons of water 100 per hour.
G Blanket insulation one inch thick conserves heat.
H Circulating pump is precision built with oil lubricated beatings
and thermal overload equipment. Silent in operation.
I Oil burner operates smoothly and quietly while providing perfect
combustion of the fuel.
K High and low limit operating controls operate :he burner
in accordance with the temperature of the boilers water. A visible scale and external adiustment makes regulation easy.
L Room thermostat either line voltage or low voltage with relay
furnished when specified.
Jacket: Attractive steel ucket in
ureen enamel completed
encloses the boiler, burner and all controls It viccupies a >pace .-t
onlv 251: x inches and is less than 5 r'ect in height. The minimum
ot 12 inches needed between back <>r boiler and nail permits installa
tion almost anv place.
ratings and dimensions (feet--inches)
boiler number
$61 net rating (connected 'adiction piut hot water load}
---water...
sq ft
--8tu per hour
1000't
firing rote--oil gph*
Heating surface... firebox volume
tq H cu ft
chimney--sue...
............
--Hetght obowe CL smoke outlet...
water toil connection tiie.
*Pue( burning rot* bated on l 40,000 Btw oH.
VT910-U
510 77 l1 19 2.9
0-8 1 0-8 12-0 O-O'/j
Kewanee-Ross Corporation
Ottilia* *4 Jvancja
4 jew, cwene,
K.EWANEE, ILLINOIS
23
*4
Tabc__i_s. Jcrol #^^S;_*t< a*;. direct-fired water heated
oil, gas or hand-fired coal
i ' ^i* ''
\ '** jT X
^ ' iJ V1 ^ !,, rs` - - . t
', i *
'''.Wliiilemanylwitfer theaters are'r.xted' on .theit 'ability to r^i^e;,
,'Water,temperature; 2'5<=i`per-h6Ur;'tabasco ratings' ire based '
^prii'a. nse bity.50;so-they do' twice the job. '-; 1 '
lf1ri '
'J'.V ,
Vi
: ,`
^1
", , '
,'','Bui|t|df?;nigged steel - plate,5;:heayief,ithan ' code,, reeju i re ments. ,
jijandrconstructed {for elOp,'-lb forking pressure (hydrostatic-
I'test pressureridf,'' i;,50jdb)^;,Tjbasco`\'i'ater 'Heaters' ...v'amply;
^strong-to stand ;tKe, hich pressuresibffcity water mains. ,,
, ,, . 'ail''
,"* % Y\'`!
IS
l, s:'r'
i -'
'ij;fr*'v- - v i^V;
. .
.`sWitremosK'bf .its,primary hedtine -surface 'directly `-over-the
-`...-t'X-; r.' *-`v, ""-c.r, " 1l_/. j;" ' . . . v/.
' ' ;,'v` '
dire;,'Tabasco,..,is. a ifast- heater \yhilej;beih"c^econornio.ii', m 'is ' :
use 'ofiueld a ``Vipv-''' ,4--` ` ' -Vf;'-'1 : rrv
-V$F'
'4f,i/^ll,'`cast'|.parts' 'are^uriusually.'heayya^Arid (if |h;..!'-' nred.,ep.ll,'
pi^u^^tffe;^uma^^^rl!'ii`:l'ar^e.'leriougfr-so'i'regular, scoop--.
:! .ftfshtivelxan 'beTusedXs i*rnany thousands of installatiohs.prove,
.i:;;!',a Kewanee1'.Tabasco* truly ` "stands'? the, .ealf," even -when
a:'--!P-v
v^yr-,
1 roughly used. ..... ' -
J-
HJ'W: vH' VgV
fc J
- I .~ '
ratings-.
X:.
k[_ Mtr numbart'. \
- f f Oil 'oai L0V 030 ' 032', 7;;x '
-1 Ji li ^capacity hot woler,' SQ'.ntt :.*' ^gph 165 ` 250 400 550 700 1
j" firing rote--oil g ph* `. . . . ? . .r"!
r .7 U ' *1.7 ' ` 2.3 '33 -
rlfe -'X `-^-gdl,Bfw per hour,.1 OOO'l 98 154 V 238 322 - . 420 '
1 grot* OrooVih',-'!-'.,.i ;'.r
,*d ft. 0>6` 1.25,;- 2.1 | 3.2;
fuel bumingirates bosed onH 40,Q00 Btu oil. -
` 3.2
'_
dimensions and data (feet-inches) ,
A'--ihsfl.dlbmotsr...
4 .i", . :v^ 1-6,. 3 "O-p "2-1
2-7, a 2-7-
ba* diameter. ....
,<8. * r.7 MO'!' 2-2 2-8 l 2-8 f
D^iat*r height'..'.., a. s, : '`^1 4-0 4.0; ,5-0 - 4-10 .5.6 *
, , -i 4;
6^--smoteV ovHet diomerer.:
-*
,,F--ftrepot diomotor . .'^. v1. . -,i.- ^
0-4' -Mr* 0-8 * 0-8 0-8 ' M }/* 1-4. 1-8 , 2-014 - 2-0V4 ,,
'
-G--flredobf]Opening in.hatr^-width' o-e'/j 'O-S'/i '1-0% '>1-0% ;i o%:
H-j"
}t"',
^ l'l`; y`-'a *--tie*ght '0.8- -a s*9; , 0-9 ` '"'0-9
flow size.
*. - ^ .
.0-1 % '0-1.16 0- 2 ; 0-2'/j '0-2`6: * r:*
retwni size.
*.>
. o-i'A 0-1 'h 0-2
0-2'6 \0.-2V2. ' *
cteonout plug size. r.-. X y;. .- * -1. ;
0-1 'h 0-116 -0-2 ` 0-2* 0*2
"
outside surface to'cover.. .
so ft My 17;, r 27 ^ ^'32... ' 38 *
I
, approximate weight--heater shell', .lb 290 350 -^toase and castings'lb 140. 180
vi.. - '"otol.'.1. .r..*K". .'lb 430 530
V-'I/'"1'
' 'v>:.
620 ' - 800v 980 220 - 300 290 / 840: 1100. 1270,
' * '"<
i' * ;
; \\ r
>
'; 4, ' *
S* ' t"
v,
>
' i ->-
a "J iJV
41 4]
! ... 1
. '1
- ~J` r,~
-V h :5<,
; --
*if s' i - s
1*
_
1 j," ' - , i . -
1y
: -1 ,.
ivt;- r
.* ^
- : 1 j. . s', V-' '
1V
, . '' , ' .. _
'1
H i ';TL
`V '-'i
;1 '1b . `V't, . r.X~
,
. X . v . . > . '1
j'-1: ''`itx : '
.0 J. ' ' r '
- . 1 X !4
`1 _ '
i fx 1'
1 ' r* ' i V
c
d
*v
Cottage VT510-DW . . . direct-fired water heater
140 gallons . . . 100 rise
For an abundance of hot vvarer f.:<t the Kew.tnc-c Cortace Boiler used as a direa-rircd water heater pros ides a most un usual performance- Teamed with any pood oil or ,-a-. burner it operates with a surprising esonomy in the use or tucl. er ;t requires very little floor space.
Enclosed in an attractive steel g.icker it Is only - \ > n. m.: less than o ft high. Built according to ASME .--de. a s tested with 150 lb hydrostatic pressure tor workmc prv"~.'c> up to 100 lb.
Easy to clean: Simply remo\e the S bolts, r,,
:hc
cover plate and tubes can be reached for sc.iie rcmo-..i . .
also the top of firebox. An important feature p -....A t es
where water conditions are adverse.
typical piping connections (diagram at left)
A
For most rav^.-able circulating conditions stor.uv tank
aid be
J 'I f -'! placed a> man ibuve the heater js headroom permits.
FLOW
SUPPLY
'NLET
C-'Id ^uter 'i:rrlv -h- uid L-ntcr mor.iltv tank through pux ,1:.:.:,": t> within 6 ;n. r b<i?t',m.
RELIEF
-- .-- --------------------------- ^
Return circulating 'me between tame and hearer mould mv:' ;
VALVE g
i \
STORAGE TANK
=
b'-uom or k > pp< site Cold -water inlet.
Hot water Row [me -should connect at either end or ton nr nk Return mav connect to the hack the heater or to any "tiler "t the
bottom "pemngs.
"-m ,. . . 11
COTTAGE 1 BOILER
CIRCULATING RETURNS
ratings
boila* numbtr
capacity
tOO* riaa gph
100' Ha 3 hr
oil 9Ph*
bring rata
gat btu par hr
I| : /r*\
<(^>
[j -
1 RETURN
j pRAIN
L
VT510-DW
140 420
*Fual burning rott oaiad on 1 40,000 8u oil.
dimensions (feet--inches)
1.1
144 ;:o
k bailor
n urnbar
hght
Igth width
P<r
turn
tmako avtlat
da
chimnay tiia ! tight
vr5IO-DW <*
Ml
M1
0-1 Vj 0-1'/:
0-7 0-8 * 0-81 16-0
Kewanee-Ross Corporation
O^i--i i A*--*-- IiHW fc V"4ar4 fc--nan1 Cara
KEWANEE, ILLINOIS
25
4y **i
r. J`>
` * "r*
- '7+ '-'2 ' f: a*W
V.:-
-V ,5 *\Y.*s
storagewaterheaters-r-,-----------t.-, , - 1 m'v' *1ij.t..*....i.;
V ,-
':>> : ,1
.V
';
i*! r
i4*
.ifss.fli \ ; -i
.*. j*' ,
i ->. . * v. .
tVl*1*, i:,j r
., ,, v, here; varyingjauanrities ot hor.water areuised.'it- irreeu*'*
. -r r 4 .. ', H'
. lar(
and^exhjusti.orJli>c 'sti*amfis/.ivj:!iiMe.;
,4 -i)* l *" V .^Kew<%a0w%AeA SW'S^1^ritgI .e^^Va\ t4c* --r^ivA ^ I'eLJa-tiAef.asAA-^* p:. ^niya ai.d. eJ .k^ \T..\cr_v.!* t
i v'usetfuu!!',i<efvicer?\\*ith^^cJtiric' culs cipaNct-jflHc.irini: <>'
*:n- +
% ,.*v
wirv^;, ir't-
>- ,. v .' .
- to 6000 &Ub&I6t`">-1itc'i?KrilfeVr'-<Vai''in^tc:v.pvra:uV<.-`t.
.MJ-l., if-i'-'-t ", | ;j,
i . - '- *,'*''
vi W -'i '
, ' . , ,, , i. ,
*1 v-.jfk'imT+J.^up^to.^
tank*. -tV
\r
* ^s^ll^ns^capacityjvr' .water 'Canr'^bc/ hc-atcrd *j'nCj;.'w^ {in'uiared^/*'
- insuring! a^
WirhV aj:^r>v'.i(cining; '
v'.-rln`vi<J^on?fhe boilers. < r <thcr >tv.ir.'._A`
' /it SVuj.'.,' ;
r , t s ,"f t'lri!' j ' ***. r+* V' * i -,'i
capacities and dimensions
, '*' The-heatint^fdcinent;is cunsrruacd >i>iic.i\:;-.'2.v^ v'-p-
* 'perstubin^iberir'intovjj L^shapc. which- tako^arc*P r .fnv
h' ^expansion/of^the,,tub- in^>crMce:
!* . roiiedi;ihro^hhe^tube^ihWt?and,':held j'n'pl.ict oi:urW"
hi,.
'"r;;-.
w.`> ^'i..lV-;'. - ^ v
-
,^r-T portipljtesvfoi1 prevent'1'Vibration jndx:.\\'e.irnnt:' -
V^" *':?*-&
;* :"*-.\V: !
a , ^ ty
''f.e.Is'4 ?naore.*:iaun^fternneaahvvtvvef.,a:s-.sd*keres,tisgfio,-r.a^icocmurtTa^*tteO!vrl,emaj,ka".e-n:t,,m-ed-,:1'Lainti4' t'..M>' rc'are>.`r
a~V.s, '.^'- r\j... < I1 ,->'V' '-..V ` fglP ,";Jj j;\. ,4'! T' r./ '.. *',V'>'., .-*,v.!.. ;*.
Th^s\'eryfwidei range^ofi capaci ties, chunks'^anci^heJtin.q *"
< > ^coils''mak'^
iit*ajmo>V>iiny operatihg? cJndi*'. `
iUon. with one d^tHese sMndard'units. f 4 ^ ^ ^'v; j
;tVr `
V'T .
T't-
8'
' 1* <-(.r.
'.Sit.*'' '
`vV'
Ji . fcj
J0f_.
c -v.v --
' --tShChTtS
X .S.-I - >i ~
COll data (feet * inches)
heating ceil
tixe end no.
A---2.5 A--5 A--10
B--15 B--20 B--25
C--30 C--40
0--50 0--75 0--100
e--150 6--200 6--250
f--300
heating 1 cep. OPM
40' to !MP ' with steam et
etmetpherlc'' pressure
; so 1 100 200
1 300 i 400 ' 500
600 ; 800
. 1000 I 1500 ] 2000
i 3000 4000 5000
I 6000 -
1
] heating surface sg ft
1
i.i 5 10
15 20 25
30 40
50 75 100
150 200 .250 J -
1 '300
horttontal tank min. length
1-6 2-6 5-6
4-8 .4.4 5-6
5-0' 5-0
5-0 6-6 B-6
7-6 9-6 9-6
v 0*6
Oponingi 2'/j in. and tmaller ero pip* thread. Larger openings furnished with companion (tango.
V
blo*-ar..p
->A>f3ot O-*o>u>i*l:
steam '
inlet
outlet
0-2 0-2 0*2
-* 0-2'/j 1- 0-2,/i'-
0-2
0-4 0-4 1 \
0-5 * 0-5 0-5
0-8 :0-8
0-8
0-10
0-1 t o-l 0-1
o-l'/. 0-1 V*. 0-P/4
. 0-2 , . 0-2
o-2'yi ' 0-2'4
0-2'/
0-4 0-4 0-4
0-5 *
1 ' v , : ': tank data (feet . inches)
*ok .{ tr9. ,.->tank<iiio ' ` ,htr' , >op.r I* . r no. gal.. dia . Igth*
91-J
* 'i' i 'J
,:v4v I. ".f
) ,v
, ^ ourtot
|
blow*lH ` off `
.bwiil.*; tap ' J_.
tl|V
2404 2405 2406 2407
`3005 3006 ' 3007 .t 3008
1,5 2-0 *'-'; 4i0' , 1 ;2 * , 2-3 r2.0-i 0-S'/. :o-2'/,- JOv'V,. Cr-Vl ,r'l-
1 18'- 2-0, *`5-0:
2:6 > 2-0u 0*5'/i 0-2^ `0; V/t - 5-1; ^
,141 2-0 S 6:0 1 1:2.,* 3:0., 2-0'4 0-5'/el 0-2'/j
1M -
164 2-0 * i7-v0 >-2 V - 3r6; , 2-0 o.5'/*>o:2,/i.'
*,,0-1
` 180 2-6-s ,5-0;' , I-41 . 2:6 -c : 2^6 ` 0r-5*/4. 215 2-6 6-0 frl-4 3-0 i 2-6 0- Va
. 255-#!;J2.6<-!7;0. i,l-4^ t3,4,!- -2*6
285; 2:6 *-'.8-0 "'^1 ^4.0 - Vl2-dr. 0-5 Vi'
3*2'/l*. o-
; o-i ,J
0*2'/j'1 '0-1'/,.. t"-M '' ;7
0- 2 Vi,, `0-1 Vi.
'f
. 3606 - 31 o`y- ,3-0fc* `6-0 `
t8J-ov ;,3-'0 0-5 V4 ^0-3; / 0-HV .*,0- V -
3607 .1 385>..i. 3*0s i`n:'7-0lf ^l'-4''!> .r3i68! *hQf 0-5% 0 3
d- IV2 i o-| :-1
3608 .. \ 415 3-0 8-0 VI-4.`
{3:0 0-5% OO'i, ``O- l '/j * v0-l - '
3609, l" 475^ j!o r ,e-0i :,i.4^ ^4r6*i. ` 3-0 . 0-5% "0:3V"" (0*1 V{ >3-r. '
3610 >: 500j'4 3f0* lO-Ot] M;.4Vv 'so. .{3-0;^ 0-5% 0:3--f :o-j.vi - >m:
1
. '[. 'it '
'| '!
4207 " >500 ^ 3-6 * ,7*0!; ;! -:4 ,s3-6lr V3:d'V 0-6H
4208
575 3-6:.*>8:0!; $: *;0 !'3-6^ 0-6 Vs
-2 . -i 'Sw 0-2 f
, '4209 650> 3-6; i*' ' 9;0
;4-67 l3E4;-iO-4% '0-3;
,4210 `-720'.: 3-6 * lO.-O^ iM-4'V 5i0- ,3-'4-,,l6(r4W 0-3
d-2 v. tO'-l'Vxi: 0-2.` `3- IV.,-
-4212 . . = 860?, 3-6 1.1 2^0^. W'*'t '6-0 r 42 UX &.! oop^f 3j6 A.i4^p- *\\a ; .7:0:
0.-6H 0-3'i > '0-2il'.v J.` > Vi 0-6H <p-3 fO: Jp-2 ' yt ' O-.V'/j,
4810
4812 4814
.940 ' 4*0. i! 10:"0i- :i-6- 5-0> i'iiOl'- 3,4 y. i0-4i,'^ A%-2'/u i.O-.r/j'
?H25,V 4:o?k,i2-o'
6-0*-. U-02'7 0-6% o-er.S |-o^2Xi ' w.-v
.13001 Arp^i^O: -1:6"1 '^oj 1'4-dV 0-6% 0;4:. 3-2!/i ..m3-,! 7* "
<*>*
0 ,0
5410 >190^ 4i'6:*^o-o:
;5-0:rt *$6' ' 0*6 /
i i0*2'/jv
5412:' :U25'? 4^6^1 2-0 ; \:Ar 6;o7 **. OiA ! 0-4 i',.. ;0-2'/j
54 u*:, ,61.665 % 4ig j.vi 4-0; ,1 -6$ 7-0'. JI3-67 0-6 0*4- , l0-7Yx'
'i
.
..
6010 6012
f400 " -1700-
* j1 - - 6014, ^20001;
6016 - >-2240n
5i0id-0i ' 1-~8.
5-0 * 1 2*0'^ ;-l-85*0 > 14-0 ;;1-8 5-o:ri6-or; t>8,
5-0 - 13.60 0-v6l h ;o-4 ' 0- 2 Vi :
^0 V ;3-6 ,` OiAVj 0-4, ii0-2.'/jS
v:
7-0 :3*6 0-6' 2 d-`4'.-'. .O^.'/j ;'td-i '/j-c
8-0 "t 3-6 0-6-' '0-4 V I 0-2V> M7| 1
.j-
-- * eh'. ^ s - -v. 1 ...'1 1,-
1 v 1 , e1" v, v t'-/
^ . j,
' Shell openingi.'ASME.codb ovor^125 Ib swp and.ovor S in. 'diameter, ore^nanged noulei.
>
26
ji,. '
;.?
' M; `
H ,l* , k.b ` irK'
Mr
' * ,4;vf '
-` J
fans for every size boiler
^"hen you are up iL\imst a Jirncu!: -:avk rr-b-
1cm. yi'ur Kcwjnee Boiler can be turni bed with
Complete inJuced draft equipment. These anas
are designed to proxide con^ant {.ilrhouch .idiu-'t-
jbie) predetermined draft for Rulers. K>tn huh
and low pressure, and will idwand Hue e.ix
temperatures up to
F. wic:m maximum r*-m
temperature ot 1J5 ' F.
Designed as a ''straight through" unit, these in duced Jratt fans are ca>ilv installed and L.m be mounted m anv position as .1 H.ineid M.uion of brc-eUnnq or stack.
Not onlv are these units low in
-r d
quire minimum maintenance, but pto ,0 rum
boiler efficiency at all loads, rceardkv' "t w..,t;:er
conditions.
For further information and cc-mri
in
duced draft fans f.>r KcA.inee Bod. - o ns;.,: -..-ur
nearest Keuunec bales Otfice.
Illustration at loft shows (top) two-stage induced draft bifurcator with 3-phase variable-speed motor and companion flanges, (bottom! nine-step speed controller, magnetic starter and push-button station.
I
Photo courtesy of Mlnneapolis-Molino Company, Kansas City, Kansas
Photo courtosy of Nutrona Mills, Inc., Wichita Palls, Texas
Kewanee-Ross Corporation
V*wm l WiW tilliw & >Ww
CawfN*
KEWANEE, ILLINOIS
27
/.r.-t- }mLe -iM-'.st.
:*i;'
r' *' , ,
W Vt-f1
i.y..ik-v.Ar' J
!J,, -- . V . ,*'/'ft;?* &. H fSj .
-- `
..
'............................... t <
\ v-.'
r c- --
^ ;a
<',*' . .
,, ,<-,]/ j,, ,, i
a .
j'
ty'S'vjf'tt'*
V AA 1 i< < 1
V *
,,
... -j".v^'yy.vA
.1kr- ^ '.V'; il - : '
; for commercial firebox and
V.
scotch type, boilers
i,
p** KewineejboiIcfS.arelallrbuiltito^iccommoditeSiriJirOa1 water, >
K
r' t
.........:<i;v
w? ."
l[ 'HeatineJx'6i!s' .:^r^
.or-`ihsuhMhcbWtvre-J: . . -*
i ; : e* '
>': ! V
':; which can; Be-installed -it?the' factory'; or.at'te'r, tlie- IfoiIwr-' ist*v. .
I'; , ,
v*
: ; on the job.
' ij.vyfci'.'f" I ..' :
'Copper., tubingfd^j^ierous^sizei^brasecl..'into^ bronze. ;ritr:ns: ''.V vWi.;'enjs;'tapp'eii ^.witli^ standardl' pipet* tlarcaJsS' .r. Kxknuts'
rfj; ''and" rihg,.gaske6Sfesj:t;v.boiIer$tcel^mounting blite
v.yifi ',5'''%f
;>f,ff. !;",-w *,< y,
uill: >.\< -
;*[>' S(Sc& sheeth)bber*(>askets"a.`. make, these coils emcient and..>
y,.fe|j, -'C w, ,
I?' '
f-r f ,,i , r
,
'i4 *nff.kft. t ,l-`s '
-'
-^y ' ;V,r ;.-v'
li In tables'^elp^the^symboi SR6-24*. means^a', single -row; or 6 *,
: -.1.,
y-'- ,y `' 1
row ot! sjpipes {,
.';]'42 inches .long.:
.vy
ii;' 'f
*K"
' I"',
r ** .' I>>'
capacities
storage ; tank operation
3:- . .-iS.
: - f:' `U
(i insta ntaneoiis'f'floyrl"V-
. if.V .f-iVVv -' `
! boil** } . number i
1
coil no-
max tise
rated cdpocity fotol gol.'.heatiM
40 -140 [ 3 hr* in botier wstor
212- F
:,sl80 8
5176-78 5179
SR6-24, SR8-24 086*24 DR8-24 088-30 2 088-30
'
90 120 180 240 320 640
55 70 UO 145 190 380 r
5180.81
088-36 2 D88-36
400 800
240 480 -
088-42 5182:83 2 088-42
480 960
290 . 580
5184 5185
088-48 2 D88-48 3 088-48
560 5 120 J 680 '
1 1
335
.670 1005'
5186-88 5189.90
088-54 3 088-54.
DR8-60 3 088-60
.. 640 1920
. i 720 2160
1 * .385^l 1l`55,,
1 430 1. 1290
ld' urfaca
*'
boiler number
COil rated.,capacity ` j i .tetal aal: heated^,
end max. '
'in.boileriwater.
tit*
i/i212?:R
f;
- tetol > urfaeej. V;
^number
^t-4eil'4'' iV.-fA'.^eted capacity'"
''
1totol`gel. heoted-7'.!'V- L..11
v ' boiler(water j ,.* v.-4*
.'f-^l hr-- < V`| min t
,
:
3.0 3.9 6.0 7.7 9.9 19.8
.11.9 23.8
14.0 28.0 ,
16.1 32.2 48.3 .
18.2 54.6
20.3 60;9 11
7L80
0R8-66; OR8-72^ 088-70 2 088-70
: '800 -ft it- /*807':: j?" 22.4---V
880 ,- r ,530 '
',940
- * {." ,575 V ,, 24.4,'.,n 50 ; ' 53.2^
1 r"?rNr>\. f'V5220', , f,:> ; 3.7 ;,T. ,;-47
,, s'. 4 w
OON:i t \,'280i' y\ 'C,*:Z tk!
5176*^8 Vv QON-2 ,%"H0i,;' / ' .5:8-, |.,,23:4.,:>..
5179*8 i . 2 QON-2. : ; 700 ; <} .;-i'i,6 -V-,;: 46.8 A'
7102
' 088-84
1040
'625'^ - 28.7t't'i'
2 088-841 ->^2080>X >, 1250 ; K.J7.8S
"..QON.3 - QON-4
r. v* *y - 10R8-90 ". -M 120 *; 670 ;
30.8 -ig 5182-85 3 QON.4
. . !<
088-96 ;-1 200'y : -^,7,20., 1 ; .',32.9-4 ; -4A . *1; -v OOI4-7
7L81 r*`. 2-088-96 ' .jaoba'"1!
t`440.' . 65.8 ' .5186*88 3QON*7
y' 7183,84 `7L86
088-^32 2 OR0il O2
3 088-102
,M 280,, ,* ;rV <77ov; H 35.0 1'
i2560! ,s ifyuo' \ 70.0'"
3840
2310"' ^105:0.^
: .4, .
7180*85 7186*90
-`oon-s '2-QON-8
3QON-8
v: 7.1:0s
-088-108 v H'360 r:t "'*8151 * . 088*114 iiiWI .' ` ' lS l2 DR8-1 W 1 >2880 rV l. ^ i 730 r'
* %-37.l~39.2 4 78.'4,'*1
088*120 " M520.F'' : ,'io . * <40.3 7 7187*90 3 088*120 . .iMbtfi `2750, , 1 20.9* `
5189,90 (3QON.8 ;C'n'
> 1#\t`, t r . k'
"<4 '*
;* 420 . , !:, '/490 A- f 1.* -j*..; 'U328:'
\\ 1'470
24.4,;f|-.:V'7.8:'
fre.'<. 8d0O0O>'-'.i \ -/I 0.3-/
4-3:-3
i` >'io^'"..;,";r?20!3V<-
?>w700' ' i'j'iooi '
,![::
i;
;21 31..47;
wi'.4i.'x,,J4}6.'.*7' V` /
1:? 2100 t -,\35.r, --V, 140:1. ' '
V >2l00i !,,j 35.1 4.
1-40.1 .' '
\'j *.
'4.4-',5" 1
h
. K`. ^ ' a * Intormatien on coil* tor IM-800 boilori on oppflcaHon.
' '` ^
.
,T,
Any coil *hortr thon h maximvffl natht liitod obovo may b* lubstitutod,in ochtboilr'where lou hot water eQDQcity it required.^-
.
Coil iniet and outlet tame tize iron pipe lap, I in, on TON and I Vi in.1on QON initantanacwsl alio l '/i^itv on OR.and il in. on SR troca'a* tank coiltilr
i
`;> *
ii < *' `` y. '
, .V,
(
;, v "`J'f?/
/V'
}
'i
28
,, Jr-t.'1r~
yi'.l'y.'.A).-,-.
.;3`ur--
- :" r,y
/.
'.<11
1 ' r
x . i "I.-, ' -y-C--r'Tt
, *s, j;*'
1 C. 1
l<
:'' <.!
. ' ,'f^
.t'.jr"! 'u.
.. .
"r.. i,, y': it.
,* r
indirect hot water heating coils for residential boilers
Kewanee boilers for home heating can be vuuipped with in direct water heating coils (storage tank or instantaneous type) either at the factory or after the boiler is installed and in use.
All are made with openings to .lccommod.i: _- -tie hot water coils and it is necessary to remove only the . jrcr ng plate, insert the coil, md bolt it into place
Kewanee coils for domestic hot water are Mib-tantially built for long, trouble-free use and efficient operation. The eonper tubing is brazed into bronze fittings mounted on a -tee! mounting plate with locknuts and gasket Coil ends are tapped to receive standard pipe thread.
capacities
storage tank operation
instantaneous flow
I coil roted capacity no. gallon* heated
coil rated capacity no. gallons heated
boiler ngmhet
and max size
40 .140" 3 hr* n boilor wotor
212 F
180 F
surface sq ft
and max sue
40 040> in 180* bailor water
1 hr
1 mm
surface sq H
Any coil shorter than the maximum
Square-Heat type 'R" boiler
length* listed at left may be substituted
. 5R6-2* see-2*-
90 1 20
55 3 0 70 3 9
in eaeh boiler where lest hot water capacity is required.
3R5
l DR6-24
i DR8-24
1 80 240
;o 145
5 3 TON- 1 OOn. '
2 20 2 80
3 7 i 54 7 4.7 i 8 7
3R2 3R3, 5 3R4, 6
3R9 3R7
OR8-30 088-36 OR8-42
DRS-48 ' DR8-54
320 400 480
560 640
190 240 290
335 385
1 99 11 9 4 3
' 6.1
i32
son-: CON.3 CCn.4
CON.4 COn-7
--------330--------
J20 a 90
490 500
5.3 7.0 8.2 '
8.2 10.0 .
23 4 28 0 32.6
32.6 40 0
Coil inlet and outlet some site iron pipe top, 1 in. on TON ond 114 in. on QON instantaneogs, also I 4 in. on DR and
3R1Q 3R9
3R*> 2
088-60
0R8-60
088-66 DR8-72
720 720 800 880
430 430 480 530
i *23 i! 2220.3.
1 24 5
CON.7 CON-8 COn-8 OCn- 8
&00 700 700 700
1 0.0 1 1.7 11.7 1 1.7
40 0 46 7
46 7
1 in. on SR storage tonic coils.
Round type "R" boiler
;|
,;
*
1 734.. 173S. 1736, 1737
A65
65
\ y
1734, 1735, 1736, 1737 1735, 1736. 1737
Cl 50
150
-SO 2 0
i
90 0
i 70
N35
210
5 1 U0
Square-heat boilers hove topping each side for external water heater, also on right tide for low water cut-off with plug.
1736. 1737
D20O
200
120 1 6.6
EN?6
250
2 . 16.5
Cottage boiler
---------------------- -----------------
yTsio
V-55
55 i i
35
:
9
v. 1 80
180
3.0 ! 10.75
Kewanee-Ross Corporation
Dwwob af Hantai *o4miw 4
Wwi Ceietii--
KEWANEE, ILLINOIS
29
boiler support brackets and structural steel suspension
For :xin turnuic height (be;,onJ the code stand ards}, Ketvanee structural steel suspension oners a solid setting independent ot turnace brickwork. The gusset bearing plate brackets ;ne support tor setting the boiler on a separate masonry base.
specifications boiler support brackets
For Sow pressure firebox and T\pe C boilers :he sup per: brackets shall consist of two pairs of steel btarmg plates, each with 'wo pussets welded to the boiler at the bottom of the waterleg. Each gusset to have a 1 2 in. hole tor wiring insulation to the boiler For high pressure firebox boilers, two pairs of forced steel welded bearing plate brackets Jrilled for secure fastening at bottom of the waterlec with srud bolts. ' On inch and low pressure hrebox boilers the barrel shali be -upporred bv a cast iron A ' frame hackstand grouted Ti masonry pier
specifications structural steel suspension
Suspension 'hall consist of four steel H-columns with Marine plates. one pair each side of boiler jnd eight pairs ot r.ttved steel brackets fastened to boiler s.nely and to priwidr lateral stability according to AS*ME con struction code Each H-O'lumn shall he securely baited to two pairs of boiler brackets. On hrebox boilers the barrel shall be supported by an "A" frame hackstand of steel members and bracing with top saddle anj bottom beirmg plates welded into one unit. All Column inJ hackstand beating plates ha\e holt holes tor anchoring to inundation. (Anchor bolts not furnished h\ Kt-wanee.)
30
E E
r-- ---------1
5"-0S in
BEARING BRACKETS-TYPE C BOILERS
BEARING BRACKETS-LOW PRESSURE BOILERS
1
Mi
U BEARING BRACKETS-HIGH PRESSURE BOILERS
D
1 TP 1i l
SUPPORTING columns- type c
SUPPORTING COLUMNS & BACKSTANO
A
safety valves
boilers over 1 5 lb swp Number and size varies with valve setting. All boilers having '00 sq ft or less of heating surface furnished with one valve. Boilers having more than 500 sq ft of heating surface furnished with two or more valves. Manufacturer reserves right to use separate outlets or yokes as conditions require.
boilers 1 5 !b swp One or more valves furnished depending on required capacity.
typical boiler installations
lift Dr. Pepper Company Dallas, Texas Two Kowanoo "500" series high pressure boilers
(light Hotel Mead Wisconsin Rapids, Wis. Three Kewanee Square* Heat type "R" boilers
left Saint Mary's Hospital ia Salle, Illinois Three Kewanee Hi-test boilers
flight Ohio Form Bureau Office Building Columbus, Ohio Three Kewanee type "C" boilers
Kewanee-Ross Corporation
Kiwim t4*ar t
SiwUn Carpar** --
KEWANEE, ILLINOIS
31
branch offices Kewanee Boiler Division
APPLETON, WIS. P. O. Bo* 355
ARDMORE, PA. Suburban Square Building
ATLANTA, GA. 955 W. Marietta St., N.W.
BALTIMORE. MD. 2301 N. Charles St.
BIRMINGHAM, ALA. 2224 Comer Building
BOSTON, MASS. 127 Federal Street
BUTTE, MONT. 909 E. Second Street
CAPE ELIZABETH, ME. 46 Forest
CHATTANOOGA, TENN. 720 James Building
CHICAGO. ILLINOIS 549 W. Washington Blvd.
CINCINNATI, OHIO 2107 Central Avenue
CLEVELAND, OHIO 1401 Prospect Avenue
COLUMBUS, OHIO 20 S. Third Street
DALLAS, TEXAS 4411 Belmont Avenue
DENVER, COLO. 1228 California Street
DES MOINES, IOWA 407 Hubbell Building
DETROIT, MICH. 12950 Hamilton Avenue
phone no.
3-3 J 32 Midway
2-8170 Elgin 1226
Belmont 5-4161
3-4645 Liberty 2-3311
5457 Portland
2*7673
6-6657 Central 6-7525 Garfield
5252 Cherry 1-6911
Main 3544 Victor 0177 Tobor 4505
3-7817 Townsend
8-0684
phone no.
EL PASO, TEXAS 600 W. Poisano Drive
3-1405
GRAND RAPIDS, MICH. 33 J Ottawa Avenue, N.W.
9-2352
GREEN BAY, WIS. P. O. Box 324
Depere 126
GREENSBORO, N. C. 211 W. Sycamore Street
3-2526
GREENVILLE, S. C. 104 E. Stone Avenue
3-7488
HOUSTON, TEXAS 1309 Anita Street
Keystone 7431
INDIANAPOLIS, IND. 31 E. Georgia Street
Imperial 6^76
KANSAS CITY, MO. 2014 Wyandotte Street
Harrison 0696
KEWANEE, ILLINOIS 101 Franklin Street
4481
KINGSTON, PA. 303 Market Street
Butler 7-4117
LOS ANGELES. CALIF. 320 Crocker Slreet
Michigan 2363
LOUISVILLE. KY 300 W. Mam Street
Jackson 5541
MADISON. WIS. 416 W. Johnson Street
5-2102
MEMPHIS, TENN. 668 5. Moin Street
8-0339
MILWAUKEE. WIS. 312 E. Wisconsin Avenue
Broadway 1-1840
MINNEAPOLIS, MINN.
Fillmore
300 Builders Exchange Building 6741
NEW HAVEN, CONN. 902 Chopel Street
Locust 2-8085
Kewanee-Ross Corporation
Dfv-Mn t rUw#rcw Had B*or A
Co*p--o*ow
KEWANEE, ILLINOIS
NEW ORLEANS, LA. 816 Howard Avenue
NEW YORK, N. Y. 40 West 40th Street
OKLAHOMA CITY, OKLA. 120 East Main Street
OMAHA, NEBR. 40B South 19th St.
PITTSBURGH, PA. 1005 Empire Bldg.
PORTLAND, ORE. 432 Pocific Bldg.
RICHMOND, VA. Bellevue Station
ROANOKE, VA. Grondin Rood Station
SAGINAW, MICH. 2340 Mershon Street
ST. LOUIS, MO. 2835 Washington Blvd.
SALT LAKE CITY, UTAH 204 Dooly Building
SAN ANTONIO, TEXAS 109 Barrera Street
SAN FRANCISCO, CALIF. 637 Minna Street
SCHENECTADY, N. Y. 277 State Street
SEATTLE, WASH. 72 Vine Street
SPOKANE, WASH. 2932 E. Trent Ave.
TAMPA, FLA. 2925 W. Hillsboro Ave.
TOLEDO, OHIO 702 Madison Avenue
TULSA, OKLA. 15 West 10th Street
WASHINGTON, D. C. 15th & H Streets
WICHITA, KANS. 811 E. Boyley Street
phone no. Tulone 7105 Oxford 5-1970 Forrest 5-7301
Jackson 7636 Grant
1-6425 Beacon
6197
6-2337
2-6548
2-4147 Fronklin
3406
4-6421 Fannin
7229 Market 1-3612
4-7822 Eliot 0230
Lakeview 1539
33*8171 Garfield
8359
2-1033 Executive
3-4044
2-3484
0
3
) )