Document aJk2E2y8jjg4rM7KMgwk7v5ba

PLAINTIFF' EXHIBIT ASI-26 1 more engineering more material and labor more experience make the difference 2 morO engineering: From the design stage, right through to the finished product, the skill and experience of Kewanee engineers is applied continually. First in the de signing and proper proportioning of boilers to assure maxi mum steam production . . . then studying each step of their manufacture . . . and finally in numerous tests of the finished product to make certain it performs as planned. more material goes into Kewanees to insure extra strength and the generous sizing of all parts that equips them to handle large overloads with efficiency. Even the Kewanee Boilers of compact design . . . intended for use when less floor space or head room is available . . . are never skimped in materials or measurements hence operate at full efficiency throughout their entire firing range. morO labor is put into Kewanees. Notice the smooth riveting, the carefully welded seams, the fine finish of all cast parts! This requires more labor but it puts something extra into the boilers that reflects quality. more experience: Over 85 years of boiler build ing experience can't be matched by guesswork. When a Kewanee goes onto a job the owner gets all the "know how" Kewanee has accumulated during many years of fabricating boilers of steel. These are things . . . some of them intangible . . . which make Kewanee Boilers different and better. nationwide representation: There is a Ke wanee representative as near as your telephone and every branch is staffed with men who know boilers and the many problems of generating steam. They are anxious to serve you. See back cover for listing of branch offices. Copyright 1933 Kowonoo-Ross Corporation high pressure boilers number of sires 15 8 6 13 SBI hp rating from to 30 304 61 304 7 36 39 304 pressure 125-150 125-150 125 125-150 characteristics riveted firebox welded firebox scotch type scotch type low pressure boilers number of sizes 13 11 15 SBI rating--sq ft steam water from to from to 5470 42500 8750 68000 7290 42500 11660 68000 4250 42500 6800 68000 characteristics scotch type welded firebox welded firebox series no. 500 Hi-Test Scottie Jr. M-800 1 | page ' 4-5 j 6-7 8-9 ! 10-13 series no. M-800 Type "C" 5000 ' page : 10-13 ; 14-15 , 16-17 residential boilers number of sizes 12 4 1 SBI net rating--sq ft steam water from to from to 900 5000 1440 8000 400 900 640 1440 510 510 510 510 characteristics series no. welded horizontal tube welded horizontal tube welded vertical tube welded boiler-burner unit Square-Heat Round "R" Cottage VT510 Cottage VT510-U | page ! 18-19 ' 20-21 1 22 ' 23 water heating equipment number Of sizes 5 1 29 capacity--gal from to 165 700 140 140 95 2240 --> characteristics l welded | welded ) welded series no. page i Tabasco 24 1 Cottage VT510-DW i 25 | Storage Water Heater | 26 accessories induced draft water heating coils water heating coils structural steel supports safety valves | characteristics t j storage tank & instantaneous--commercial boilers storage tank & instantaneous--residential boilers j high pressure boilers page 27 28 29 30 31 Kewanee-Ross Corporation Dmkmm tt Iwum *--e> A UaMa>4 Umtary Upet'O KEWANEE, ILLINOIS 500 Series ... heavy duty 15 sizes ... 30 to 304 hp 125 and 1 50 lb swp for heavy-duty service providing heat for large apart ments, schools, hospitals, office buildings and factories, or tor p.'cver or process steam . . . Kcwanee '500`' is a :ejl gianr. It is strong, dependable and very efficient. A two-pass firebox t\pe, it a the design which made the name Kewanee famous. From top to bottom and from front to rear it is built with fust one idea ... to make it the most efficient, dependable and lung lived boiler that can be constructed. Big high fireboxes provide plenty of space and air for the fuel to combine wath oxygen and burn, completing the process of combus tion before the gases reach the return tubes. In the long travel of the hot gases through the firebox and the lower tubes, men through the upper tubes to the exit chamber, all usable heat is tranMtrrtd 'o the boiler's water. Water surrounds both upper and lower banks of tubes and all sides and top of the fire chamber so the transfer of heat is rapid anJ certain. Waterways are free of obstructions promoting rapid rise of the steam bubbles to the steam disengaging area and into the ca pacious steam chamber at the top of the boiler. The use of 3 inch tubes permits more tubes and more heating sur face further helping make the "500" a very fast and efficient steamer. And this efficiency is maintained even when the boiler is pushed :o produce 50%. and more steam than is guaranteed bv its rated capacity. Both banks of tubes are easily accessible through the larce Joors at front and rear . . . manholes and hand holes Dm*.-oe access to the waterways. Sptctficatio'ts and data art tor mechanically-fired ; F - .n--:'"'.,- u.n haid-irea coal type i ;*e nearrit Keaane. < rp'r 'c <. ratings mechanically fired -- oil, gas or coal bailor number 'Qting--horsepower . . --iftam radiotion sq ft --6*u per hour 000`s ---ntegm per hour 212 F lb 574 30 4250 1020 1050 firing rote-"-Oil gph* . . . --gat 4tu per hr 000`i 13 1910 heating jurface <S8I mini f,,rnac volume {SBI mini . furnace height 'SBI mm) . q ft cu ft ft-in 250 30.4 2-6 fireboji voi above mud ring eu ft "odditionoi furnece height for stoker (S8I mm] ft-m. 39.6 ,ofety vosve copoc>ty --oil-goi Bred lb steam per hr --itocer fired ib iteom per hr 2000 1750 577 578 579 580 581 35 4860 1 166 1 200 39 5470 13U 1350 44 6080 1459 1500 52 7290 1750 1800 61 8500 2040 2100 15 2180 16 2460 18 2740 22 3280 26 3830 266 34 6 2-6'/j 322 39.1 2-7'/, 350 43.5 2-7V* 429 52.1 2-834 500 60.8 2-10 39 6 48.5 40.5 62 1 69 6 582 583 584 585 506 74 10330 2479 2560 87 12150 2916 3010 109 15180 3643 3750 130 18220 4373 4510 1 52 21250 5100 5260 31 4650 37 5460 46 6840 54 8200 64 9560 608 73.8 2-11 Z2 715 86.8 3-1/2 893 108.5 3-4% 1072 130.2 3-7 1250 151 8 3-10 97.0 1 10.4 130.9 137.2 160.2 587 174 24290 5830 6010 588 217 30360 72B6 7510 589 26! 36*30 870 9010 590 304 42500 !o;oo 10510 73 10920 91 13670 ' 10 164C0 ; 27 19120 U29 173.5 4-0 M 1786 216.9 4-6/j 2143 260 3 5-0,/j 2500 303 6 56 183.2 207 8 231.9 2 4 5.5 0-6 2288 2002 2576 2254 2864 2506 3432 3003 4000 3500 4864 4256 5720 5005 7144 6251 8576 7504 10000 8750 11432 10003 14288 1 2502 171 *4 15001 20000 '7530 Fuel burning roles based on 150,000 8fu oil. Represents distance below bottom of water leg that dearth must be let for SBI minimum furnace volume and height. Standard equipment--pront and rear base panels have 8'/j * I 1 /j In. opening and cover plate Flue cleoner and hondle. Manhole furnished on 580 and larger. Baffle plate m reor combustion chomoer furnnhed on 576 to 588. Standard trim, staam only--Sofety valve, steam gauge with ivohon and cock; water column wlfh water-gage glots and t.iree gage cocks, chain operetta on 536 and larger. 4 w -- Y- -Z -zz dimensi and data (feet--Inches) boiler numbtf A---boiler diameter.......................... fr--ooilar length................................ C--boiler height............................. 0 -wqt>r line height..................... 6 -water column height. . ............. F--attorn supply height.................. G--tmoke outlet height............... H--i-eor stand height J-^1eom supply ................... *K--safety valve-. . ............... M--feed <*oler. each tide . ... N--blow-off height.. O--fireoo*--w>dth................... P--- --length.......................... 8-- --height T--oose---width . . U-- --length.... V-- --height. ............... ............... W--smoke outlet--length. ... X-- --width. Y-- --location. . I--teor door eleorance, min AA--foundation--width. BB-- --length.. .. CC--rear stand. . FF * GG--ffredoor opening m boiler width height, , . MM--centerline elr to ftredoor opg KK--opened Rredoor to boiler ZZ--tube replacement tpace oreecnmg diameter--one boiler itocn--diameter......................... --height. ., breeching diometer --two boilers stock--diameter............... --height...... ... "steam supply size.......................... blow-off size ........................ feed water size... "outside surface to cover sp ft opptokimote weight -- 1 25 lb swp............ -- 1 50 lb swp. lb lb 576 577 578 579 580 SI1 582 3-6 8-7 6-87, 6-1 5-1 1 7-2 5*1 1 3-2 6-0 4-5 2-3 1-7 3-0 4-2 3-57, 3-IP/, 4*1 I'/j 1-2 2-8 0-9 0-6'/, 3-6 3-0 3-6/i 2-9 3-6 9-6/, 6-87, O-l 5-1 1 7-2 5*U 3-2 6-6 4-5 2-9 1-7 3-0 4-2 3-5/j 3-11 7, 4-11/1 1-2 2-8 0-9 0-6/i 3-6 3-0 3-6/i 3-8 4-0 8-11'/, 7-2'/i 6-4 6-2 7-8 6-2 3-2" 6*0 4-5 2-6 1-7 3-6 4-2 3-8 4-57, 4-11/i 1-2 2-10 0-1 1 0-7/j 4-0 3-6 3-6/, 3-0 4-0 9-8 7-2/, 6-4 6-2 7-8 6-2 3-2 6-6 4-5 2-8 1-7 3-6 4-2 3-8 4-5'/, 4- ! /, 1-2 2-10 0-1 1 0*7ft 4-0 3-6 3-6/, 3-8 4-6 9* 2'4 7-10'/, 6-1 1 6-9 8-5 6*9 3-4 2-iy, 4-5 2-7 1-7 4-0 4*2 4-1 4-n/i 4-1 !/, 1-2 3-4 1-0 0-8 2-6 4-0 3-6/, 3-3 4-6 10*6 7-10'/, 6-1 1 6-9 8-5 6-9 3-4 2-!/, 4-11 2-n 1-7 4-0 4-8 4-1 4-1 P/, 5-5'/, 1-2 3-4 1-0 0-8 2-6 4-0 4-0/, 4.0 5-0 11-1 8-6 7-4 7-2 9-1 7-3 3-5 3-4 6-4 2-9 1-10 4-5 6-0 4.1 5-6 6-1 1 1-5 3-8 1-2 0-9 2-9 4-5 5-6 3-0 584 5-0 12-9 8-6 7-4 7-2 9-1 7-3 3-5 3-6 6-11 3-2 1-30 4-5 6-10 4-1 5-6 7-9 1-5 3-8 1-2 0-9 2-9 4-5 6-4 3-10 584 5-6 12-10 9-0 7-9 7-7 9-7 7-7 3-5 3-9 6-11 3-2 M0 4-1 1 6-10 4-4 6-0 7-9 1-5 4-3 1-3 0-9'/, 3-0 4-1 1 6-4 4-0 5tS 5-6 I 4-9 9-0 7-9 7-7 9-7 7-7 3-5 3-8 7-3 3-9 M0 4-1 1 7-2 4-4 6-0 8-1 1-5 4-3 1-3 0-9'/, 3-0 4-1 1 6-8 5-6 514 6-0 14-9 9-6 8-PA 7.1 pa 10-1 8-1 3-5 3-8 7-3 3-5 M0 5-5 7-2 4-61/, 6-6 a-t 1-5 4-8 1-7 o-i PA 3-3 5-5 6-8 S-6 587 6-6 1 4-9 9-8 8-4 8-2 10-3 8-2 3-1 2-9/, 7-7 3-7 M0 5-11 7-6 4-7 7-0 8-5 1-5 5-0 1-6 0-1 1 3-6 5-11 7-0 5-2 588 6-6 17-7*/, 9-8 8-4 8-2 10-2 A 8-2 3-1 12-6 U-8 4.1 M0 5-11 8-6 4-7 7-0 9-5 1-5 5-0 1-6 o-u 3-6 5-1 1 8-0 6-10 589 7-0 17-9 A 10-6 9-0 8-10 11-07, 9-0 3-5 1 2-6 U-8 4-3 2-2 6-5 8-6 4-9 7-67, 9-5 1-9 5-4 M0 i-l 3-9 6-5 3-9 6-8 590 7-0 20-O'A 10-6 9-0 8-' 0 i i-oA 9-0 3-5 1 3-3 16-5 4-3 2-2 o-5 9-0 4-9 7-6/, 9.11 19 5-4 M0 1.1 3-9 6-5 3-6 70 one 2-3 k. M 1-8 6*10 1-7 1-5 45-0 2-1 Ml 55-0 0-4 0-1 7, 0-1 '/< 130 1-8 7-9 1-8 1-6 50-0 2-2 2-0 60-0 0-4 - 0-1 '/, 0-1 % 140 1-8 6-10 1-9 1-7 45-0 2-3 2-1 55-0 0-4 0-1 /, o-l % 1 50 1-8 7-7 1-10 1-8 50-0 2-4 2-2 60-0 0-4 0-1A o-l / 1 60 0-574 2-3 6-9 1-1 1 1-9 45-0 2-6 2-4 55-0 0-4 0-2 0-1 Va 180 0-5 7* 2-3 8-1 2-0 1-10 50-0 2-7 2-5 60-0 0-4 0-2 0-1 'A 1 95 two 1 -1 A 1-3 0-8 0-8 0-1 1 2-3 2-3 2-3 a-4 10-0 10-1 2-2 2-0 50-0 2-4 2-2 60-0 2-6 2-4 60-0 2-10 2-8 60-0 3-0 2-10 70-0 3-4 3-1 70-0 0-6 0-2 0-PA 0-6 . 0-6 0-2 0-2 0-1 7, O-l1/, 225 255 285 0-1 1 2-3 12-0 2-7 2-5 70-0 3-5 3-2 80-0 0-60-2 0-PA 320 0-1 1 2-6 1 1-8 2-9 2-7 70-0 3-8 3-5 80.0 0-6 0-2'A 0-1 7, 340 two 1 -6 * ' 4 ' i 7* 2-6 MV* 2-4 2-6 1 1 .4 14-2 '4.0 2-H 2-9 70-0 3-3 3-0 85-0 3-5 3-2 90-: 3-1 ! 38 00-0 4-2 i-i i 95-0 4.2 100-0 0-6 0-2'A 0-'7, 0-8 0- 2'/, 0-1 A 33-3 0-2 360 4 1 S 455 : .4V4 2-6 ' 5-3 3-7 3-4 4-a 1 15.0 :-a 3-2 7, 3-2 505 7980 8780 8510 9360 9590 10550 10100 mio 1 1700 5 2 870 12760 l 4030 14930 1 6420 16530 18180 19230 21 1 50 21940 24130 24100 26510 26840 29520 31210 34330 350CC 38500 23320 42700 For safety valves, tee page 31. **300 >b American Standard Flonge. '"Includei front head and smekebo*. Kewanee-Ross Corporation Dkmmr leMt 4 Vender* 6e*leri Cor*er-w> KEWANEE, ILLINOIS 5 Hi-Test for power or industrial process steam 8 sizes ... 61 to 304 hp 125 and 1 50 lb swp The Kewanee Hi-Tcst Scrub is an excellent example <? a ail weld boiler. fusion electric welding. loints of unquestioned strength are obtained, then X-Ray checked n> be certain th.i: : :e seams are perfect. The entire boiler i> then placed m .1 huue S:ri." Relieving Furnace where the joints are thoroughly anne.n.d :!xn allowed to cool gradually, eliminating am- pissibihtv -t ! vkeu an stresses. Tins ts the Number l VC eld procedure t>d! i.i welded Kewanees for high pressure. The finished boiler is further subiected to hydrostatic U't rrc-- <ures equal to one jnd one-half times its allowable u.i'rkna >K-"uri. in accordance with ASME Code requirements Each NuLr is riu a''. inspected . . during construction and when v.-mpleted Sv i oualiried inspecror licensed by the Xjtionul Board or Boiler and Pressure Vessel inspectors to insure acceptance &y an-, state ->r municipality. Kewanee Hi-Test is in design. Two cylindrical shells of different diameters are joined with tube heads, ruth only a few diagonal head braces needed. The front and rejr due gas chambers are an integral part of the boiler shell, eliminating joints. The metal casing on the front of the boiler, which forms the 5re chamber, is designed for a refractory lining (not furnished as part of the boiler), making n entirely self-contained. Hi-Test Kewanee mav be fired from the front or rear with ail fuels. For information on the Hi-Test for hand-nrinc. consult your local Kewanee representative. Specibcjiions and data are sr-:wn i >r mechanu jity-nrta r -.* tir,n hand tired I'-pei ijnu.il :hc neareti Keuanee r>e. en:11. ratings mechanically fired oil, gas or coal boiler number rar-ng--norse power --fttu per hour --steam per hour--2 1 2* f tiding 'Ote--O'l gp^' --got fltu per hour . . heo'ing turf ace. furnace *Oiume m casing . safetv valve capocity --pil-gas fired . --Voter fired . .. 1300's . ...lb 1 000's sa ft eu ft lb iteam per hr lb iteom per hr HT50 HT60 HT7J HT100 : HT123 61 2040 2100 26 3800 500 82 73 2448 i 2520 | _____________ 91 3060 3150 31 4600 600 101 38 | 5700 ) | 750 M7 122 4080 4200 . ^2 l 5100 5260 : 51 1 7700 i 64 : 9600 1"" 1 1000 j 1 250 ! 155 j i 98 4000 3500 4800 4200 I 6QQ0 j 5250 ! ! 8000 | 7000 i j 1QQ00 j 8750 HT1 JO 1 82 6120 6310 76 1 1400 1500 233 12000 10500 MT200 HT250 243 9'60 341 0 ' 02 ! 53CO '"A 1 0200 ; os- o -7 ' a* 2000 300 2500 349 16000 i 200C0 14000 1 17500 Pu.| burning 'Ql#t DOjfld On '50,000 Btu Oil. Standard e<ju<pm*nt--Standord Heel easing *t*nding to top of masonry bos*. No be from *urmsned. Damp*r in smoit* cutlet. Flu* clanr* with handtai. Standard rrinw-Staam gag* with siphon end cock; high and low wot*r alarm column with inclined gag* glass and chcin oo*roi*d gag* saw; chain oo*rat*d try cocks safety valves as raauirad by ASmE cod*, oiow-o* valve and cock, globe and c-ecs ai* for feed pip*. Np other accessories or piping. Special trimmings furnished at addifionol cost. 6 a o 1) dimensions and data (feet--i..cne,) bailor number HTSO HT60 HT7S HT10O HT123 HT150 HT20O HT2J0 A-^ylinder diameter--rear............................................................................................................................. 8-- --front................. ........................ ............................. C--boiler length D--water lino height E--wotor column height F-*--steam supply height G--smoko outlet height H--saddle height, front & rear J--iteom supply *K --safety walye M--feed water, eoch side N--btow-off 0---furnace--width P-- --'ength R-- --height S--furnace casing--height T-- --width .................. U-- --length ................ V--^hell e Mention beyond cosing. , . W--smoke outlet--length X-- --width Y-- --location Z--'ea' door cleorance, mm. A A--base--width 88-- --side wall thickness CC-- --front woil rhicunesi 00-- --ear wail thickness. EE ---rear brick pier. Ff--rear brick pier width. ZZ--tube replacement space ... ... breeching diomeer--one boiler stack--diameter . --neight breeching diameter- two boilers Hock--diameter.. . . --height **iteam supply use blow-off site .... feed water size "firebrick m coting **2 insulation immg m furnace ,a ft outside surface to cover iQ ft approximate weight, bailer--125 lb swp. -- 1 50 lb iwp. ib lb 5*6 3-6 12*5 6-8 6*6 8*2 7-5 2-2 10-1 4-5 2-10 2-8 4-0 4.8 3* i 0*/a 5.1 I 5-10 6-6 0-10 3-0 1-2 0-9 3-0 6-6 1-3 0-11 Ml 2-0 2-8 7-7 2-0 1.10 45-0 2-7 2-5 55-0 0-4 0-2 0-1 V* 1300 130 115 1 2470 12570 5-6 3-6 13-5 7-2 7-0 8-9 7-11 2-8 10-8 4-6 3-3 2-8 4-0 5-2 4-4'/, 6-5 5-10 7-0 Q-10 3-0 1-2 0-9 3-0 6-6 1-3 Q-H Ml 2-6 2-8 8-7 2-2 2-0 50-0 2-10 2-8 60-0 0-6 0-2 0-1 '/, 1450 155 1 45 14080 U280 6-0 3-6 14-3 7-2 7-0 8-9 7-11 2-2 1 1-3 4-6 3-6 2-8- 4-5 5-2 4-4'/, 6-7 6-3 7-4 /, 0-10 3-0 1-2 0-9 3-3 6-1 1 1-3 0-1 1 2-4 2-n 2-8 9-5 2-5 2-3 55-0 3-2 3-0 65-0 0-6 0-2 0-1 Vl 1700 165 165 17405 17805 6-6 4-0 15-5 7-9 7-7 9-7 8-9 2-6 12-2 4-6 3-7 2-10 4-1 1 5-8 4-8'rt 7-3 7-6 8-3 0-8 3-6 1-4 0-10 3-6 8-2 1-7'/, 1-3'/, 2-4 3-3 3-0 10*1 2-7 2-5 60-0 3-5 3-2 70-0 0-6 0-2 o-i Vi 2750 205 200 21070 21570 7-0 4-6 16-2 8-10 8-8 10-11 10-1 3-4 12-5 5-0 3-9 3-0 5-5 5-8 5-6'/, 8-4 8-0 8-3 0-10 3-10 1-6 0-1 1 3-9 8-8 1-7'/, 1 - 3 '/, 2-4 3-8 3-6 10-4 2-9 2-7 65-0 3-8 3-5 75-0 0-6 0-2'/, 0-!'/, 3250 235 250 24630 25330 7-0 4-6 18-6 8-10 8-8 10-11 10-1 3-4 14-9 5-3 3-9 3-0 5-5 6-8 5*6'/, 8-4 8-0 9-3 0-10 3-10 1-6 0-11 3-9 8-8 1-7'/, 1-3'/, 2-4 5-0 3-6 12-8 3-0 2-10 70-0 4-0 3-9 80-0 0-6 0-2'/, o-iv. 3500 260 300 28000 28700 7-6 5-0 19-5 9.7 9-5 1 M0 1 l -0 3-9 15-a 3-9 3-3 6-0 7.7 6-0 9-4 a-7 10-2 0-'0 6 0-1 1 4-0 9-3 . 7 Vj 3 V, 2.4 5-0 1 3-7 3-5 3-2 30-0 3-0 5-6 20-n 9-3 12-4 11.6 3-9 7- 0 k-5 3-1 6-0 97 9-1 10-8 0 1 o > 4-3 7Vj 24 3-4 95-3 4. 2 90-0 0-8 o-:v, 0-2 '05-0 0-2 340 Ji5 32 5 ; 32000 330G0 37000 For safety vafeoi, see page 31. 300 lb Ametieon Standard flange. *** No brickwork, furnace refroetory or insulation includ'd. Kewanee-Ross Corporation K.EWANEE, ILLINOIS f. ' .1 1 ScottieJunior 6 sixes . . . 7 to 36 hp 125 lb swp Originally designed Mr >hips with?'limited space .and head r-'bm. Kewjnce Scotch , pe boilers *pr<i' ide the'>ulufton ;'ur many-.p-.-wer and industrial process steam,problems/; 1 Shell of flange quality steej, <vi:h a: tw<ite'-i*nu:h-.t 5^.090.to'6V'i)0i p*'unJs per square inch. Lmduudin.il fi-mr > riv eted' with Joublc, butt -trap copytiuction. Girthye!:V.x ire, nwtvd and caulked uuht/around "the nJjcII, edge's* and at .t-ucivlnj\*t. :he welded furnace.. .Solid thr"Ui;iwu\s complc-ie front .to, V. `*r.;cma. Rear combustionchamber , -.vith hVch re fractory lining -installed' at the tactory.r . * j' . ' , , . - tong gas trayol tn the reartBrnuch/fhe -furnace :.\n ;o' the tro'nfhthroughrheayy' 'id age- }>" 'nre tubes \ v t/. n^vr' '.hi usable heat'to the water. '. - ,," Longer. creates ideal. .Home conditions :> ^firing with any. standard" gun-type' burner. r- : ` Mounted oh Isklds*: . i Scottie Jr., arrives' ' , ,,v hstantial, wood skids. No; foundation is- needed. 'St t at-extra cost. , d. s !'- . `available Heads, hot flanged of firebox quality, Steel and tube holes jtrepanned^from solid^'plate. r- h '' ' Heavy cast iron doors precision ground for gas tight' fit.' Heavily insulated to' prevent warping,'/ m 1 Threaded flange .steam outlet assures tight fitting..-:--_bie- proof connection-with <ream mains; "!,*\ : Large Steam space assures,, ampie reserve'* '1* /ti.-im.', L'ncbstrucred disengaging area it voter'line keeps .the/Veam'dry.' . , ratings mechanically fired --oil or gas r!- : 5.. : 'V * bailer number rating--hone power --Btj per novr --*teom per nar--2 1 2 ' F . | i I j certified output rating ... firing foic--oil gpn* --go* 8tw oer hour. .. heating turtace... furnace volume > safety vaive capacity * Fvel burning rotes bated on 140.000 8tu oil. I000-*. . ib | ip j 1000'* j IQ ft \Cu ft l >b (team per hr { HM4 - o- HM9 7. 234 242 12 410 ' 0.5 `3.5 4 80 `I 18 58 ' 1 810 , 60 '5 . j ~ , V ' 24;V , 4 30 i 79?_ HM,S4 ..r^HMas^ . . `MM JO" '''' 3 400 _ 62C *' < 24'.-'r,./v '300 !' -V'; -.;930, /, .30 f l 020 ' ; ;oso-1' -.r 3i . . *:*h liz , 27 j . 8-r . 1 1200 , ; 36- * 11.5 ! .. 1620' . IS , *14.4' -T 2030^ * ' ' K; 54 '7 3 2 430' v V '< - >50 - . 200' - -'j , 250. '3 20 - !-. 2. >t,`. ' }4 6 ; j .'473 w_ 5 3fl ^ f ' - ! 1200 * 1600 * --1-- ; --- -M- {. 2000 1 : . 2400' Standard equipment --- All boiler* counted on tkidi; manhole >n hm25 4` 30 refroctory lined rear comauttion cnamaer. rear end plate with cleanout Poor, % >n. funble plug *ocket wrench. Hue scraper with handle. Steel furnace entension with coverplate and peephole. j Standard trim, steam only--Water cslumn with watef-goge g<d*s and *hp* ga^e cock*, ttearn goge, tiphon end'cock,'safety value; V<t 'in. Penderrhy 'n<ecor: n ^woff valve*.- doing ,and'.fitting* for attaching _trimmings to 'boiier. 'No irtmm.igj.* fumiihed w.ih hot woter boilers.'* > # 8 4'. -N B -G -- A ACOtSS '0 r-S-BlC plus 6 . '--*--------- r 9LOWOFF -------------------------- R HOSE STRA1NEB s- Q 6`* 6' skios o i dimensions and data (feet inches) boiler number A--Boiler diameter overall ................... 8--Boiler length overall ... C--boiiet shell height ... D--water line height --water column height, EE--height from boiler CL F--vecm supp'v *G--nofe'v vQive H^fumoce OiQmeter J--shell--diameter <-- --length l--nmot outlet length M-- --width N-- ---Cl to Ooiler. O-- --height P--cieoronce Beneoth sneil Q--legs location R--skids location $--CL f'onr leg to front head. T--tube 'eoJocement ipaee Breeching diameter stacA---diameter . --height** steam tupplv ure biow-o*T size - . draH loss through Oosler .. comoustion gases of smoke outlet cfnt at 600= p outside surface to cover approximate weight--on skids with regular futures inches of gir sg ft ib i HM6 3-n 6-10 V* 4-67j 3-10'/, 3-3'/, 0-1P/4 M 1-3 1 -9 3-6 5-1 2-0 0-7 0-5"j 3-8 1 -0 3 2'/: 3-1 0-9 3-4 1-2 10 20 2 0-2 '-i 260 57 3400 * For safety valves, see page 31. ** For pressure atomizing ail Sumr or power gas burner i HM9 4-5 7-0/: 5-2 4-5 4-3 i-i >4 1-2 13 2-3 4-3 5-3 2-6 :-8 2.* 4.: i .i 3-3 V: 3-i 09 3-6 i -4 1-2 23-0 C-2 0.' 1' 3e 430 67 4730 HM15 4.5 8-9'/, 5-2 4-5 4-3 1.1 '4 1-6 1-3 2-3 4-0 7-3 2-6 0-3 0-6 4-2 1. i 3-7 3-6 1-3 5-3 1.5 1-3 2S.0 0-2 3-1 '4 07 650 90 ' 5600 HM20 4-5 10-6'/: 5-2 4.5 4.3 M '4 2-0 '-4'/, 2-0 4-0 3-R 2-6 0-8 0-6 4-2 l-l 5-1 3-4 16 70 1-7 1-5 25-0 0-2 .10 860 l1 I 6400 HM25 4-11 10-7 5-7'/, 4.9'., 4.7'/j 1-3 1-6 1-10 '/j 2-4 4-6 8-9 3-2 0-8 0-7"i 4-6"; 5-0 3-9 I .6 6-11 1-8 ' -6 250 0-2 1 '4 0 ; '080 , 125 | 7800 HM30 4-1 1 120 5-7": 4-9": 4-7'/: 1-3 2-0 ' -5 2-4 4-A ': 2 :3 :' ' A - ; 6-1 2? I5 9-4 -. ; 'i ; 4 05 i 2 300 Kewanee-Ross Corporation isw & s*wefe Sowrom c* KEVC'ANEE, ILLINOIS ratings mechanically fired-- oil or gas boiler number-- High prenure) --tow pressure Sfil ratmg^-norseoower.. . ---sfeom radiation --water rodiotion . --Slu per nour --steam per nour---212' F SBI net rating--iff am. --wafer --fltu per nour cer'lfied Output rating firing rote--10<i gph*. . --goi 8tu per hour hea'mg surface f SBI mm| furnace volume (SBI mn). net furnace volume safety valve capacity --over 1 5 It twp ... -- I 5 lb jwp fHM-878 HM-179 MM.IBO HM.BB1 HM-BB2 HM-883 ffM-884 MM-815 MM-886 &HM-487 IM-87B LM-879 tM-BBO LM-881 LM-182 LM.I83 LM-B84 IM-BBj LM-184 LM.BB7 IM-B88 IM-BB94 LM-890 sq ft sq ft IOOO'i 'b . sq H sq ft 000's hp . 1000`s sg ft Cu ft cu ft 39 5470 8750 1313 1 350 4S00 7200 1080 59 16 2460 322 39.1 45 8 44 6060 9720 1 459 1500 5000 8000 1 200 66 18 2740 358 43 5 48.4 52 7290 11660 1750 1800 6000 9600 1 440 78 22 3280 429 52 1 57,9 61 8500 1 3600 2040 2100 7000 1 1200 '680 92 26 3830 500 60 8 62 4 74 10330 16520 2479 2560 8500 13600 2040 11 1 31 4650 608 73.8 79 8 87 12150 19440 2916 3010 10000 16000 2400 131 37 5460 715 86.8 87 5 109 15180 24280 3643 3750 12500 2CC00 3000 1 6a 46 6840 893 1 08.5 ! '0 2 1 30 18220 29150 4373 4510 15000 24000 3600 195 54 8200 1072 130.2 Ul 1 152 21250 34000 5100 5260 17500 2 8000 4200 223 64 9560 1250 151.8 1537 174 24290 38860 5830 6010 20000 32000 4800 261 73 10920 1 429 173.5 174 0 30360 48570 7286 7510 25000 40000 6000 326 91 13670 216.9 217.0 , 9010 7200 392 16400 262.9 "i 10 510 8 400 '9- :o - r- -i 308 8 lb steam per hr b steam per nr 2576 1610 2864 1790 3432 2145 4000 2500 4364 3040 5720 3575 75 44 4465 8576 5360 10000 11432 6250 7145 14288 0930 17'4^ 10715 :::o ' Fu*< burning rotes based on 1 50,000 8tu oil. Stondard equipment (15-125-150 lb steam)--Steel saddle support*, refractory lined rear comDushon cnamber factory installed. F'ue cleaner and handle. Woshout plug socket 'tenth for 1 5 lb boilers only, Standard trim (15-125*150 lb steomi --Safety volvefs) as reauired by ASmE Code, steam gage with s Dhon and cock, column win water goge glass ond three gage tacks. Choin operated water gage alvei and try cocks with boilers HM-884, LM-384 and larger. Note--For 125 and 150 lb tteom boilers Ctobe ond check vg'ves for `eed : -<e. Quick action end slow ac'ion blow-off valves a* furnished. Stondard equipment (woter boilers)--5leel saddle support!, refractory l.'#d rear combustion chamber factory installed. Flue cleaner ond handle. Wjpoui aiug socket wrench. Stondard trim (wafer bo'lert)--None furnished. Additional equipment or trim of eitra cost. 10 M-800 series * high pressure units ... 39 to 304 hp ... 125 and iso psi low pressure units . . . 1 5 psi steam or 30 psi water . . . 1,31 3,000 to 10,200,000 Btu The Scotch type Kewanee M-800 is decidedly Scotch in its iuggedntss and extreme chriftiness when it comes to pro ducing steam economically. Designed and built to generate steam with ethciency through its entire tiring range, it .an be pushed tar above its rated capacity without interrupting its usual economical operation. The M-800 is designed on S.2 square feet or" heating surface for each horsepower of its rated capacity. This proper pro portioning of primary and secondary heating surfaces :o the volume at water in the boiler comes onlv as a result of mar.v years of experience and continual testing to rind out ;.:>t what is right. 1 Shell s from heavr fiance steel wrh heads and furnace ur nrebox auuhr.. All \u-U' in r.Ltnvc witn ApME C-Je. Butlers tuc 115 and L50 psi stress rtueved. 2 Large steam chamber prmido rc-.c-nc tor exeruency demands 3 Unbroken steam disengaging area permits -team to ri^e Without unJue turbulence. 4 1 1 X 1 5 in. manhole and washout i-pcamgs give access to w aterside. 5 Corrugated furnace for extra strength and added heating surface next to the tire. Its generous size provides plenty of space for the burning fuel to mix with the air and burn completelv Low pressure boilers provided with plain circular furnace. 6 Heavy gage 3 in. tubes expanded into holes with ends rirmly rolled and beaded. 7 Rear combustion chamber is heaviU n.! . ^ r-. trac tor,\ Sailers :>t ;'.:ch pressure* incorporate a;'. ' :.',vn Lww pressure boilers dcstgned with water ba^k n Vs*.' nal rear cover plate with nbservattun port and Ju-ys ;j fusible plug. 3 Sturdy steel saddle supports m mplify -nv:i in*: ,;nd installation. No special base is required. 9 Long gas travel the length c.r the fire dumK: md .nto the rear combustion chamber then forward the l.-ng tubes gives the water in the boiler a chance to ahv.irb all -he heat . . . stepping up the transfer of heat without wasting it. 10 Rapid circulation through the unobstructed '.vaitrwavs speedily sweeps the steam bubbles up without comm, aivn an important factor m making M-800 a fast -reamer 11 Substantial hinged flue doors, canted : r pc--i. nent cas-tight fit. Provide ea<v access to fire :ubc< o r Jg.mmg and inspection. '2 Gas tight smokebox t heaw pia .tK! . .v.i.ic ': ,n me piece to boiler shell. Rectangular smoke outlet located it top. certified high efficiency Teamed with any good oil, gas or combination oi!-gas burner, Kewanee M-800 performs "on the |ob ' with overall effi ciencies of SOO and more. And this efficiency remains prac tically constant whether the boiler is being operated at 10rc or 1500 of its rated capacity. Such efficiency figures are confirmed by certified performance tests in which the total amount of the heat in the oil or gas put into the burner and the amount of water evaporated into steam are carefully measured and converted into a figure show ing the overall operating efficiency. A chart of typical boiler performance appears at. the right. percent of boiler rating 40 60 80 100 120 140 Kewanee-Ross Corporation et fc--m-- A Stttwdoe* SmWry Cnoramm KEWANEE, ILLINOIS l1 I I M-800 series i ... a great teammate for any quality oil, gas or combination oil-gas burner The Kewanee M-800 Boiler is 1de.1I tor use \\ ith any quality oil, gas or combination oil-gas burner to form a complete Boiler-Burner Unit. A ten- of the many features which make this boiler so adaptable to Bober -Burner Units are . . . complete range of sizes for both high and low pressures unusual strength and dependability ability to produce tar above rated capacities at highest efficiencies greater heating surface ease of cleaning and inspection steel skids that eliminate special base construction only two or three matching connections to make in mounting burners to Sober frame Three Boiler Burner Units developed using the M-800 Series are shown at left. For additional information on these units, write for separate catalogs. 12 dimensions and data (feet--inches) boiler number high pressure --low pressure HM-878 LM-878 HM-879 LM-879 HM-880. HM-881 IM-08CT' LM-881 HM-882 IM-882 HM-883 LM-883 HM-884 LM.884 HM-883 LM-883 HM-886 IM-836 HM.887 IM-887 HM.888 LM-988 HM-889 LM-089 HM-890 IM-890 A--boiler diameter 8--noiler length. 4-6 1 t-8 4-6 12-7 5-0 1 1-7 5-0 12-9'/, 5-6 13-2 5-6 14-10 6-0 1 6-1 6-6 1 6-7 6-6 ! 8-7 7-0 *7-9 7-6 18-11 i 3-0 20-0 9-6 20-) C--steam supply netght 0--smoke outlet height. i--water column height 6-6 6-6 7-0 7-0 7-6 7, 7-6'/, 3-07, 8-67, 8.6'/, 9-07, 9-7'/, 1 0-47,1 : 0-' 07, 6-4 6-4 6-10 6-10 7-4 7-4 7-10 8-4 8-4 8-10 9.4 ! 0-1 1 0-7 5-1 5-1 5-6 5-6 5-9'/, 5-97, 6-: 7, 6-57, 6-5 7, 6-97, 7-3 7- ' I1', 3-4 r---furnace 0 d. Of from G--furnace neight 2 - 3 /, 3-0 ;y/> 3-0 2-6/i 3-1 7, 2-6 7, 3-1 7, 2-9/, 3-3 2-97, 3-3 2-1 1 7, 35 3-2 7, 3-6 7, 3-2 7, 3-6 7, 3-6 3-8 3-37, 3 ?7, 4- 1 4- 2 ' 4-5 4 4 7, M--s'eom supply ')--sofelv valve *--feea water, each side. i---eturn 1 5 ib vwp, eaen side. M -- OlOw-off 3*0 3-6 3-1 3-7 3-8 4-2 4-9 4-10 5-4 5-5 5-5 5-6 5-7 3-6 4-3 4-3 4.4 4-5 5-0 5-0 5-0 6-6 5-6 6-6 7.0 7-0 6-7 7-1 6-6 7.1 7-4 3-2 3-: 2 9-3 10-3 9-10 ' ;-6 4-4 4-4 4-4 4-4 4-9 4-9 5-3 5-8 6-2 6-3 6-5 6-7 6 7 4-0 4-0 4-0 4-0 4-3 4-3 4-5 5-4 5-4 5-6 5-6 5-6 5.6 N--smoke outlet--"width O-- --length 0-11 0-1 1 1 -0 1-0 1-1 -! -2 1-3 1 -3 1-4 1.4 -5 1-5 2-5 2.5 3-0 3-0 3-4 3-4 3-6 J.H 3-1 1 4-7 5-4 5-7 6- 1 P--support--length , B-- --wiath S-- --neight . T-- --location U-- --center `O center v--'j6r ioiocement sooce 3-1 17, 1 -4 -6 2*3 6-1 1 7-1 3-1 i'/j -4 I -6 2-3 7-10 3-' 4-5/2 1-5 1-6 2-4 6-9 6-' 1 4-57, 1-5 1-6 2-4 7.1 1 3-' 7, 5-1 '/, 1-6 1 -6 2-5 8-1 3-2 5-t Vj -6 1-6 2-8 9-6 9. ' ; 5-7*', / 1-6 2-9 ' 0-6 6-1 1-8 1 -6 2-10 1 0-6 ' :-8 6-1 1-8 1-6 3.4 20 0-3 6-6 7, 1-10 6 3-5 11-0 7 7 - 0 7, i.io ; 1 -o j '20 ' :-r . 2-0 1 -9 3-6 2-0 6 72; 9 3-7 '0 2 sreecnmg aiometer--one OOtler stacs--dia meter --neighf .9 1-7 40-0 M0 `3 40-0 '11 I -9 35-0 2-0 1-10 40-0 2-2 2-0 40-0 2-4 2-2 45-0 2-6 2-4 50-0 2-7 2-5 50-0 2-9 2-7 55-0 2-1 1 2-9 50-0 3-3 3-0 55-0 i i i 3-2 2-7 3-4 55-0 preechmg diameter--two boilers. stock--diameter --"eight 2-3 2-1 45-0 2-4 2-2 45-0 2-6 2-4 40-0 2-7 2-5 4 5-0 2-10 2-3 45-3 30 2-10 50-0 3-4 3-1 55-0 3-5 3-2 55-0 3-8 3-5 60-0 3-1 1 3-8 55-C M4-2l j! 6o-o ; A m: 4-3 1-4 r:-2 steam supply site- 1 5 lb iwp" . --aver 1 5lbswp*** blow-off site . . re'urn site 15 lb swp feed water size 0-6 0-4 0-1 Vi 0-4 0-1 '/< 0-6 0-4 M Vi 0-4 0-1 7* 0-8 0-4 0-2 0-4 0-1 V* 0-3 0-4 0-2 0-4 0-1 % 0-8 0-6 0-2 0-4 o-l 7, 3-3 0-6 0-2 0-4 0-1 V, 0-8 0-6 0-2 0-4 o-l 7, 0-0 0-6 0-2 0-4 0- > 7, 0-8 0-6 0-2 7, 0-4 0-' 7, 0-8 0-6 0-2 7, 0-4 0-1 7, o-io ; 0-3 0-2 7,! :-6' 1 0-3 -o-:1, :-6* 0-2 :-3 Putside surface to caver sa ft : 65 ' 80 30 200 230 260 305 340 330 390 I 5 00 oo; approximate weight -- 1 5 lb swp lb 7000 7400 8200 8800 11300 12 400 1 4800 *7400 19200 22400 1 26600 j 3 1 200 3 5000 --125 lb swp V -- I 50 'b iwp ib 7600 lb 3200 8000 8700 I 0000 10400 11100 1 1 500 13100 13900 uooo 15100 17500 1 8700 20800 2 2700 21900 24900 27100 28700 32000 1 07200 34500 40100 4'900 i 5 ' 20 For sofety valves, see page 31. ** 150 lb American Standard Flange. *** 300 lb American Standard Flange. Low pressure ooiien furnished with openings for 0*1 neater Migh pressure boilers furnished w.th openings tor ail neoter and lemperature control. and sector. Overall height is increased ! /, in. nn iteel ...as rre furnished. Kewanee-Ross Corporation o~. KEWANEE, ILLINOIS 13 * type C 1 5 psi steam or 30 psi water 1,750,000 to 10,200,000 Btu Kewanee Type "C". with its corrugated Croun Sheet, has become America's most popular boiler tor heating large buildings. It tills a Jcnmtc need tor a completely dependable, fast-steaming boiler designed for restricted space. The follow me fea tures tell why. ratings* mechanically fired --oil, gas or coal A Capacious steam space presides room tor large reserve. 3 Expansive steam disengaging area is un broken, eliminating turbulence at the water !.a.- o-J keeping wet steam rrom tne mams. C Rear combustion, chamber, an m .-ni r .,-r of the firebox, concerts anv unhurned rue! : before reaching tin-tubes. 0 Crown sheet of heavy flange -tee! I- ~u a.-:! massive corrucauuns. .ulJinc -trtnuth .m,: nr atuMliv doubling the inc surtaec i\cr the -. -\-t r.:-* the tire. E Wider, .. a ,,r combustion chamber pro- vides sufficient air Jnd space to completeiv burn ail the fuel. f Long gas travol through the firebox and rear combustion chamber then forward through rhe ii.wcr tubes then again to the rear through the upper :ubes. holds the gases in the boiler until ail u^iblc heat is picked up by the boiler's water. 0 Rapid circulation of water up man '.,-e water legs .it sides, front and rear and between *r.e widely spaced firctubes prevents sediment rr* ' aa* ing and permits steam bubbles to be swept up u -- cmv ... an important factor that makes the T\ pc C ' i very quick 'Steamer." H Heavy steel base .b>enibled with -t staunch cast iron posts. J Cast doors are extra heavy, and -nsul.red to k*ep heat mside die boiler. Iptc/fu'M/ons j nd data ire un >r /on 'tc-irdin% band-nrej , .</ : chum.-firtJ :h ''(.ir,st Kcu./ue boiler number S8( rating--n'eom radiation --water radiation. ^8tu per hour. --ire am oer hour--2 1 25 F 581 net rating--steam --water --fiu oer "our firing rate oil gph* --gas 8tu per hour heating surface `S8I nun) furnace volume (S8i mini furnace height (S6I min) firebox volume above mud ring safety valve capacity sq ft tq ft 1300's lb . tq ft tq ft '000'. 1000`S sq ft Cu ft ft.in. cu ft lb steam per hr 7HO 7290 1 i 660 1750 1800 6000 9600 I 440 22 3280 429 52.1 ?-8V4 67.4 Ills 7181 3500 13600 2040 2'00 7000 1 1 200 ' 680 26 3830 500 60.8 2-10 77.8 2500 'Fuel burning rales bated an 150,000 Btu oil. nn 7183 '0330 12150 16520 , 19440 2479 2916 2560 3010 8500 13600 20*0 1 3000 ; 16000 1 2400 31 4650 60S 1 1 I 73.8 j 2-1 !'/l| 37 5460 715 86.8 3-1'/j 90.5 j 134.4 3040 1 3575 7184 15180 24280 3643 3750 12500 20000 3000 46 6840 893 108.5 3-4'/4 '29.4 4465 7185 18220 29150 4373 4510 15000 24000 3600 * 54^ 8200 1072 130.2 3-7 168.4 5360 7L86 21250 34000 5100 5260 17500 28000 4200 6* 9560 1250 151.8 3-10 193.7 6250 7187 24290 38860 5830 6010 20000 32000 4800 73 10920 1429 173.5 4-0% 218.3 7145 7188 30360 48570 7286 7510 25000 40000 6000 91 13670 1786 216.9 4-6'/j 302.2 8930 7189 . 36430 58280 8743 9010 30000 48000 7200 1 10 16400 2143 260.3 5-0Vj 377.4 '0715 7190 J2520 58000 0200 :i o 1 5*00 0 8 40 0 ; ~? IW22 303 6 5-6 433 1 Standard equipment--front and rear bate poneli hove B'/i x 11 Vi in. deonout opening. Wgjnout plug tockef wrench with extra tet of gaskets; flue cleaner with handle. Manhole furnished on boilers 7182 and larger. Standard trim, steam only--Safety valve, steam gage with jiohon and cock- water column with wottr-gog* gloss and three gage cocks, choin operated an 7136 and larger. 14 ZZ------------------------- c------------------------ H dimensions and data (feet--inches) boiler number A--boiier width.............. B--DOiler meil length C--ooiier length overall D--ooiier height E--*aser line height h---wafer column height G--steam supply ne*ghf. H--smoke Outlet height J--steam supply K --safety *aive tn-- l ft ,n. surface blow-off N--refurn height O--fireoox--width. P--- --*engh R-- --neignf 1--ease--wdth U-- --length, V-- --meignr W--smoke Outlet o-ometer . *--front smokebox depth... Y--'ear smokeod depth AA--foundation- width 6B-- --length PF x GO--firedoor opening in boiler width % height HH--centerline blr to flredoor opg JJ--height doors from bottom boiler KK^-opened firedoor a boiler 22--tube reoiocemenr space breeching diometer--one boiler stack--diameter............... --neight . , breeching diameter---two boilers. stock--diomefei . --neight .... .. steam supply size. return size Outside Svrfoce to cover sq ft approximate weight lb 7180 ' 4-0 7-2ft 9-4'/, 7-8'/, 6-7'/, 6-4 8-1 6-4ft 1-6 1-2 1-0 1-6 3-6 6-8 2-10 4-5ft 7-4'/, 1-2 2-0 0-1 1 1-3 3-6 6-0 0-3'/, 0-8 1-tOft 6-5 2-0 1 -9 50-0 2-6 2-4 60-0 0-8 0-4 153 6700 7181 7182 4-0 8-5 10-7 7-8'/, 6-7'/, 4-6 7-8 9-11 8-10 7-7 6-4 8-1 6-4'/, 7-3ft 9-2 ft 7-4 1-6 1-2 1-0 1-6 3-6 7-1 0ft 2-10 1-6 1-2 1-6 1-6 3-1 1 ft 7-1 ft 3-1 ft 4-5ft 8-7 1-2 4-1 1ft 7-10 '2 2-0 0-1 1 1-3 2-4 1-0 1-3 3-6 7-2ft 3-1 ! '/, 6-6 1-4 * 0-1 1 0-3'/, 0-8 1.10ft 0-6 0-8 1-IOft 7.7 6-i a 2-0 1-10 60-0 2-4 2-0 55-0 2-7 2-5 70-0 2-10 2-8 65-0 0-8 0-8 0-4 0-4 170 '92 7600 8800 *'50 lb American Standard Flange. ''Includes front head and smokebox. 7L83 | 7184 7LBS 4-6 8-11 ft 1 1-2 ft 8-10 7-7 7-3 ft 9.2ft 7-4 1-9 1-2 2-0 1-6 3-1 1 ft 8-5 3-1 ft 4-1 1 ft 9.1ft 1-2 2-4 1-0 1-3 3-1 1 ft 7-9 0-6 0-8 1.10 ft 8-1 2-4 2-2 65-0 30 2-10 75-0 0-8 0-4 214 10C00 5-0 9-2 ft 1 1 -6ft 9-7 ft 8-4ft 5-6 9-llft l 2-3ft 13-0ft 8-7 8-1 10-0 8-0 ft I -9 1-2 2-0 1-9 8-3'/, 10-4 ft 8-3ft 1-9 1-2 2-0 1-9 4.4ft 8-7 3.4 ft 4. 1 0 ft 9-4 3-7 5-6 6-0 9-5 10-2 1-5 '-5 2-6 2.7 1-0 1-0 1-4 1 .4 4.4ft 8-Cft 4-1 Oft 3 9 ft 1-8 x 1-0 0-4 ft 0-8 2-2ft 8-4 0-7ft 0-8 2-2ft 9.1 2-6 2-4 65-0 3-4 3-1 75-0 2-7 2-5 r70-0 3-5 3-2 80-0 0-8 0-8 0-4 0-4 2*0 275 1 i 800 1 3600 7186 1 7187 1 7188 6-0 9.3ft 12-1 ft 10-10ft 9-5 9- 1 ft 1 1.2ft 9-Oft 1-9 1.4 2-0 1.9 5-5 8-8 4-0% 6-6 9-6 1-5 2-1 1 1.2 1-8 5-5 8-1 ft 0-6 ft 0-8 2 5 ft 8-3 2-1 l 2-7 65-0 3-8 3-5 75-0 0-8 0-4 297 1 5300 6-0 10-6'ft 13-4V, 10-10 ft 9-5 6-6 1 1 1 1 ft U.9ft n-6 9-1 1 9-1 ft 1 1-2 ft 9-0ft 1 -9 1 -4 2-0 -9 9 - 7 ft 11.11 9.7ft 1-9 -4 2-0 1-1 1 5-5 9-1 1 4-0 Va 5-10 1 1-4 4-6 Vt 6-6 10-9 1-5 7-0 12-2 1-5 2-1 1 1-2 1-8 3-3 1-2 1.8 5-5 I 9.4ft 5-10 10-9'A :-M x 1.3 0-6 ft 0-8 2-5ft 0-10 0-10 2.5ft 9-6 10-1 1 2-i : 2-9' 75-0 3-3 3-0 90-0 3-1 1 3-8 85-0 4-2 3-11 100-0 0-8 0-4 ' 0-10 0-6' 322 387 17000 20100 7U9 | 7190 7-0 f i:-4ft! 1 4-2V, 1 3-6ft M-9'A i 1-6 13-11 ft U.5ft 1-9 4 2-0 2-3 6-4 : o-8 ft 5-6 7.6ft 11.7 '-9 3-5 1-2 i.a 0-4 ' 0- 2 'A 70 13.1 ft 15-1-ft ' 3-6ft ; i-6 i 3-1 i ft 2-0 4 2-0 2-3 6-4 i:-sft 7-6 ft 1 3-4 3.7 1-2 6 4 1 ! .M if. 1.1 0-10 2-5ft ' 0-4 3-5 3-2 80-0 4-6 4-2 90-0 0-10 23200 -1 0-0 3-7 3.4 4-8 4-4 0-1 0 476 Kewanee-Ross Corporation KEWANEE, ILLINOIS is 9 5000 series 1 5 psi steam or 30 psi water 1 5 sizes ... 1,020,000 to 10,200,000 Btu The Kewanee "5000" low pressure series is rapidly grossing in popularity for heating large buildings when speuneations or restricted budgets require an economical boiler of unques tioned durability and efficiency. "5000" is an electric welded series, in the fabrication of which all modern practices and improvements in welding have been combined to produce a completely dependable product ... a boiler worthy of the name Kewanc-e. . In design the "5000" is similar to that of the famous heavy-duty Kewanee "^OO" and has all those outstanding characteristics which for some 85 years have made Kcw.incc Boilers different and better. Extra large and extra high fireboxes provide ami'le 'P ice and air in which the burning fuel can mix with oxygen to complete the combustion process without waste or fuel Longer travel of gases . . . from the lire chamber through the lower bank of tubes then through the upper tunes to tne exit chamber at the front . . . gives the boO-r's water a chance to absorb and use all the heat that is atc-d in the firebox. Circulation is rapid through generously . .... water legs and between the well-spaced fire tubes, sweeping the myriad of steam bubbles up into the capacious steam chamber with out undue commotion. The disengaging areas at the w ater line are unbroken insuring a constant supply of drv steam. As is true with all Kewanee Boilers the "5000" can be fired to produce 50^ and more than its rated capacity and continue to operate at full efficiency. Spicincjttoni jnd djta are shuin for mtchjnt.jlly-nrgJ boiler;, f : tton 'e^urjtni o^nd-ftred : al types i ;Ke urest ktuavi r >:p>i - ratings mechanically fired-- oil, gas or coal bailer number $31 rating--iteem radiation .ia ft --water 'adia'ion so ft --Btu per hour ' 300's --i'eom per hour--21 2 F ,b SSI net citing--iteam SQ ft --water --Btu per hour. sa t '000's 5176 1250 6800 1020 1050 3530 5600 960 firing rote--oil gphV --gas Btu per hour. 13 1000's 1910 healing turfoee I5BI mm). . , . furnace volume <$BI mm} fumoce neight (5BI min). . . . IQ ft CU ft ft-in. 250 30.4 2-6 fireBox volume above mud ring Cu ft additional fumoce height for stoker '561 ni|" ft-in. safety va've capacity lb steo m per hr 44.3 1 250 5177 5171 \%\7}S 3110 Sill i860 7770 1 1 66 1 200 5470 8750 1313 1350 6080 9720 1459 1500 7290 1 1660 1750 1800 8500 1 3600 2010 2100 4000 6400 960 4500 7200 1080 5000 8000 1 200 6000 9600 '440 7000 1 1 200 1480 15 2180 <6 2460 18 2740 22 3280 26 3830 286 34 8 2 6 Vj 322 39 1 2-7V4 3587* 2-7% 429 52 1 2-8J4 500 60.8 2-10 44.3 49 6 54,5 60.2 66-6 1430 1610 1790 2145 2 500 5183 5183 5184 5185 5U6 10330 16520 2479 2560 12150 1 9443 2916 3010 15180 24280 3643 3750 18220 29150 4373 4510 21250 34000 5100 5260 8500 13600 2040 1Q0C0 1 6CC0 2400 1 2500 20000 3300 1 5300 1 7500 24000 28000 3400^ 4200 31 4650 37 5460 46 6840 8200 64 9560 608 73 8 2-1 1 Vi 715 86.8 3-1 Vj 893 i 38.5 3-4 >/4 1072 130.2 3-7 1250 151 8 3-10 90.6 103.2 1 17.5 123.4 137.5 3040 3575 4465 3-3 5360 0-5 6250 5187 24290 33860 5830 6010 mi 30360 48570 7286 75'0 5189 136130 58280 8743 9010 ' 5190 42500 63003 13200 13510 20000 32000 4800 25000 40000 6000 300CC 48000 7200 3500 3 ioo :o i 3403 73 10920 91 13670 l 10 16400 i 27 19*23 1429 173.5 4-0% 144.0 1786 216.9 4-6'/5 197.1 2113 j 2500 260.3 1 323 6 S-Q'/j tnrr 222.0 0-10 71*5 0-6 8930 0-10 10715 ' 2'0 3 * Fuel burning rates based on t 50,000 Btu oil. " Represents distance below bottom of water leg thof hearth mvst be set for S6I minimum furnace volume and height. Standard equipment--Front and rear bose panels have 87i x 1 1 Va in. ooenmg and cover plate, hackstand except 5176-77, flue cleaner and handle. Manhole furnished on 5192 and larger. Washout plug socket wrench with extra set of gaskets. Standard trim, steam only--Safety valve, steam gage with tiphon and cork cncolumn with water-gage glass and three gage cocks, chain operated on 5' 33 c-i-j larger. 16 K --Y 8 MANHOLE --Z --zz I1 > ( ( NOTE: Ust dimtniion drawing on this attac.ied Ry-thaal. Oo not uio drawing printed bantalh. dimensions and data (feet--inches) boiler number A--boiler diameter 8 boiler length C--boiler neight water line heignt 6--water column height P--nteom supply height G--smo*e outlet height H---reor stond height J--jteom supply K--saferv vqiv* *4--! 7, in surface blow-off N--<eturn ne-ght 0--EirebOA---width P --length ft-- --neight ` -- eose-~width J-- --length . V-- --heignt w--smoke outlet--length X-- --width <-- --(ocotion Z--rear door clearance, mm AA--found a*ion--width 33-- --tengfh CC--'ear stand "'efloor style te * GG-^tedoer opening in Doder width x height HH--centerline blr to Aredoor Opg JJ--neight doors from bottom boiler <*C--opened Aredoor to boiler ZZ--tuoe replacement toace bteechmg diameter--one boiler slack--diameter --height . breeching diameter--two boilers stack--diameter 1 height 'steom supply site return s<ze *'0\rtside surfoce to cover sq ft approximate weight lb S176 3-6 7-3 6-9 5-'0 5177 3-6 8-0 6-9 5-10 5178 3-6 fl-1 1 6-9 5-10 5179 l 5180 -73 9-10 6-9 5-10 4.0 9-9 7-2'/j 6-1 7, 5-8 7-1 5-n 3-2 5-8 7-1 5-n 3-2 5-8 7-1 5-n 3-2 5-8 7-1 5-11 3-2 5-11 7, 7-7 6-2 3-2 ' -4 1 -4 1-5 1-5 '-5 2-9 2-9 2-1 1 2-11 2-1 1 1-6 1 -6 1-6 1-6 1 -6 1-6 ' -6 '-6 1-6 1 -6 3-01/, 4-2 3-6 3-07, 4-2 3-6 3-0`/i 4-8 3-6 3-07, 5-> 3-6 3-67, 4-8 3-8 3-11 7, 3-1 l Vi 3-M /, 3-M 7, 5-0 5-0 5-6 6-0 1-2 1 -2 1-2 1-2 4-57, 5-6 1-2 2-8 0-9 0-67, 3-6 M 0-9 0-67, 3-6 2-8 0-9 0-67, 3-6 2-8 0-9 0-67, 3-6 2-10 0-11 0-77, 4-0 3-0 3-0 3-0 3-0 3-7 3-7 4-1 4-7 2-6 2-1 1 smgie frame & doub'e dm 3-6 4-1 3-3 5181 4-0 r. i 7-Vh 6-1 /, 5-1 P/, 77 6-2 3-2 1-5 2-9 1 -6 1-6 3-67, 5-2 3-8 4-SVj 6-0 1-2 2 1 0 0-1 1 0 7 Vi 4-0 3-6 4-7 4-3 5182 4-6 1 1-1 7-87, 6.5'/i 6-37, 8-1 6-7 3-2 2-0 3-6 1-6 1 -6 4-0 7, 6-0 3-10 4-1 IVi 6-10 1-2 3-4 1-3 3-3 2-6 3-1 '/j 5-5 3-2 5183 5184 5115 5186 5187 4-6 12-9 7-87, 6-57,| 5-0 i 3-7'/: 8-4'/, 7-0 S-0 15-3 S-4'/i 7-0 5-6 14-5'/, 8*9 7-2 5-6 16-0'/, 8-9 7-2 6-3'/, 8-1 6-7 3-2 6-10 8-9 7-1'/, 3-4 6-10 8-9 7-1'/, 3-4 7-0 9-1 7-3'/, 3-2 7-0 9-1 7-V/, 3-2 2-6 2-6 1 0-9 2-9 1 ' .3 4-0 4-0 12-3 4.3 5-3 1 -6 1-6 1-6 1-6 1 -6 I -6 : -9 1-9 1 ? 1 -9 4-0 V, 6-13 3-10 4- 1 V; 7.3 , 2 4-S'/, 6- 10 3-M 5-6 7-9 1-5 4-5'/, 7-2 3-M 5-6 8-1 1-5 4.11 y, 7-2 3-1 1'/, 6-0 8-1 1-5 4- 1 '/, 7-6 3-1 1 7, 6-0 8-57, '5 3-4 3-8 3-8 4-3 4-3 1-0 i 2 1-2 1-3 1-3 0-8 3-9 3-9 0-9'/, 3-9'/, 7-6 2-9 2-9 3-0 3-0 3-' 6-3 4-0 4 - 4 '-j 6-4 4-3 4-4'/, 6-8 6-3 i-l O'-, 63 5-3 i. ; -i 7 3 7, 6-3 - 9 it and tt smgie t'ome and door 5188 j 5189 ! 5190 6-0 16-3'/, 9-3 7-9 6-6 1 >7-57, j 9-9 1 3-0 0-6 19 g 50 7-7 9-77, 7 9'/, 3-2 7.10 10-17-1 3 ?% 3-2 " 3 0-' i ; 7: 7 ! 2-0 6-3 20 1 .1 1 i 2-3 4-i i -..0 1 .i : 57 -. -j 5-5 V, 8-6 4-2 7, 6-6 9-5'/, '-5 5-1 `/, 8-6 4-57, 7-0 9-57, -5 90 4 i'-i ?1 9.'. 7', 4-6 1 -7 0-1 1 '/, 3-3 5-0 1 -6 3- 1 3-5 3s 5-4 3- 2'-, 6-0 6-7 , 8-: , i: one 2 3 Vt x 1 -1 '/j 0-87, 0-8'/? 0-87, 0-87, 1 -8 1-3 1-8 i -8 3-6 6-3 7-2 8-1 1-7 1 -5 40-0 1-3 1-6 40-0 ! -9 1-7 45-0 M0 1-8 50-0 2-1 i-l 1 50-0 2-2 2-0 50-0 2-3 2-1 55-0 2-4 2-2 60-0 0-6 0-6 0-6 0-6 0-4 0-4 0-4 0-4 - 15 i 25 ' 35 45 1500 5000 5400 5800 0-J7, 0-8 M3/2 7-8 Ml 1 -9 50-0 2-6 2-4 60-0 a-8 3-4 1 60 6600 iwb 1 - 4 O-ll O-3/i 3-8 1 ' 0,/i 3-6 0-8 1 ' y/i 9.) 9-0 : ; M3 55-0 2-2 2-0 50-3 2-7 2-5 65-0 2-10 2-8 60-0 0-3 3-8 0-4 0-4 i 80 702 7400 3500 0-6 0-8 MOV, 10-8 2-2 63-3 3-0 2-i 0 70-0 0-8 0-4 227 9600 3-4'/, 0-8 2-2'/, 13-97, 2-6 2-4 65-3 3-4 3-1 75-0 3-8 0-4 257 moo two 1 -1 X 1-0 0-4'/, 0-8 2-2,'; 0-7'/, 0-8 2-2'/, 12-10 2-7 2-5 30-0 1 1 - 8 '/i 2-9 2-7 73-0 3-5 3-2 90-0 3-8 3-5 80-0 0-8 0-8 0-4 0-4 290 305 1 2800 U400 3-7 Vi 0-8 2-2'/, '3-3 7, 2-1 l 2-9 35-0 3-1 1 3-8 95-0 3-8 0-4 332 16000 wo 1 1 ' * 1 3 0-6 7, 0-8 3 -S'-, 1 3-77, 3-3 3-0 85-0 3-13 03 2 57, 14 4 3-5 3-2 9) 2 33 -1 : 7.? :7 i.x ' 350 4-2 3-H 95-0 *6 4: 130-3 4i i4 0-10 3-6* 0-10 3-6* 3 375 420 4 66 19200 22330 25233 * 150 lb American Standard Hang*. * includet front head and smpkebox. Kewanee-Ross Corporation KEWANEE, ILLINOIS 17 Square-Heat type "R" boiler l lsiiei . 216/000 to 1,200,000 Btu 900 to 5000 sq ft-steam : f 1440to8000 sq ftwater , Never before has; a .boiler been built with the ver^ satility;-'ofr;Kewanee 'Square-Heat. It is `ideal for medium "size buildings ; of all. types or';,for. small factories;- It burns ariy fuel and a change, from une' to another,, or" from mechanical .to hand tiring,' or back again, can be made quickly and, inexpensively. These, features indicate .why Square-He.it' packs so much heat'generating ability in .comparatively small space.1' A ; large, , high steam space ashurt.'s. ample,re*, , - - serve'of;dry steam. ; - *; B. Reversible smoke box may be-i^v-d '.vith nthef.1 . top or-.rear smoke, outlet.'. ,, ; >* longer gas travel*. . . to the tc.it'. :ixn ;he . front; and to- the^fear-again gets-all the !*cat into the boilers-.water. />- -; D Spimier blatlos iri oil or .gas; boilers .< $R*i to $) - .-/Swirbhot gases, against tube wajls' assuring maximum r - ''beat, transfer. . k. .i' ' Insulated/sturdycast doors are precision ^groundnrfof permanentvgas tight fit: Observation open- ' ,ing has adiustable hinged cover; for secondary.over fire air.^ * . V1 { t- \ Lorgo^ hi9h firebox provides ample-space and air'for, complete, economical burning ut the futf. Rapid circufatiori in wide free waterways steamybiibbles up.',,,without commotion, i<\ unbroken 'release-area at waterline. < r.- Shell of extra heavy high quality Vteel adds' strength. Extra substantial steel base, can be reversed for bring from rear. ", i - -Extra-higli bases (20.' and'50. in!-)' for mcefun- ';ical* tiririi; instead of-sVandatd la ;in.' base, are avail able. if ispecitied..;at extra cost.' j! s " ' - . S&t-.aii jre *?'; ,r. *,huu: fr<: F. >r lb'- etjrJir.i Aj e-i .* r<S ,r..uit 'ih Te jrr */ Kt u umt uprisYntattvt. ratings * mechanically fired*--oil, gas or coal bailer numbar 5BI ne roting--steam.............. --water.............. --Btu per hour, . .. 1000's fifing rote--oit gph*.............. 1 --gas Btu per Hour ... 1 1000's --mtoker** l >b per tir heating turfare (SBI min) . . . . . . . 1 to ft furnace volume (SSI mm)......... safety valve capacity.......... lb steam per hr * fust burning rates based on 1 40.000 Btu oil. 3RI 900 1440 216 3.3 405 36 53 8.2 265 JM 1100 1760 264 3.7 495 44 65 10.0 325 3R3 K ! | a" 1300 2080 312 4.3 585 52 17 11.8 385 1 1500' - I j 800 i 2400 , 1-2880 360 ; j .432 " 1-6.0 ' 5.0 675 I BIO 60 1 71 , 88 - ; 13.6 !. 440 ` 1 106 16.6 530 * Based on coal having 12,000 Btu per lb as fired. 3R4 1 3*7, - 3M f 3R10 f n 3*11 2 200 3520 528 * 7.3 990 38 -129 20.0 645 ' : 26ob'V ' ! 4160.1,.! .,624 :' . 3000 4800 720 '3500 5600 840' 4000* | ` 4500 - n 6400 4 7200 ,'' 960 ' j1 ioao : . 8.7 ' : - 1170 J 04 ' 10.0- - ' 11-7 1350 1575 . W .120 ' . ' 140 13.3 15:0. : . 1800 v. 2025 ' * 160- - * ' l 80 k ' V 53 23.6, I -:765 , 177 , 5 206 'r27.3'* ** > 31.8 . .. '885 ' \ 1030 . ' 236 -I 265 36.3. 1. 40.9 '* 1180 r- 1325 5000 8000 12:3 . ;so7 .'2250 ?00 * - 294. ' . 45.4.. f 470 , -. r' - - -V ' " Mote 1--Standard base it 14 in, - high. Boies of 20 and 30 in. height available for mechanical firing at additional cost.1 Note J--Boiler ratings do not include allowance for heating domestic water by indirect coils. When the hot water demond is added to the heating load.for more than ten minutes in any hour, an allowance of 4 sq ft of steam radiation or 6.4 sq ft of water radiation must be added for each gallon of wafer (heated. Standard equipment -ft- cleanout plugs, 3R1 to 3*1!. 8 cleanout, plugs. ]R1 ?. Sochet wrench with extra set of gaskets. Steel base completsi'with 8 x 14An.' covered opening. Rue and soot scrapers with handies. Spinner blades for 3R1i to 3R8 Oil or Gos boiler* my Standard trim, steam---Water gage, two.'compression gogo cocks,' steam .9090, pop safety valve. - ; j* ' * l . - ' ' Watev^-Combinotion oltitude 9090 and thermometer only.- ' 18 dimensions and data (feet--Inches) boiler number A--soner wd!fi overall ... --acket width 8--pone' length -- :aener length . . ...................... C*--OO'ier he>gnt -- acitel height from floor . . . wafer nne height. t--s'eo-i or worer iuppiv neight c---nmcve owiiei height G--ueam or water lupply M--neate- connection height, each ude i~^0'i conneciion height < -- e'.rn -e-git u--- nrecjcs----wfllh N-- ---ength. 0-- --height P--oose--w.ath t } 4 m. hign. 9-- --engrh >--jmoe o^riet--width T"-- --length . U--imokebo* overoll V--iTione outlet locution floor >0 oorom of fluedoor *--ooened firedoor to boiler. Y--*oor to eotrom of fi'edoor --Aredoor opening m Boiler--width . --height oreecnmg diameter iwhen flattened, fill ova! imote necu) . Chimney--diometer --- ne.gni ileom lupply me return me Ha*r connection size Outiide lurtace *o sever, jniacketed. opprosimaie weight, umacketed sq ft ib 3R1 2-6 2*7 2-6'/: 2-9 '/, 5-6 5-6 '/: 4-7'/, 5-6/j 3-8'/j 0-10 4-OVt 4-9'/: '-5'/: 2-0 2-1 /: 1-9'/: 2-3'/j 2 10'/: 0-9 1-4% m 0-7'/: 2-10 1-9'/: 1-7/, 1-4 0-1 1 1-2 0-10 3Q-0 0-4 0-3 0-2'/j 38 nsoo 3R2 2-6 2-7'/: 3*0'/j 3-3 '/% 5-6 5-6'/: 4.7'/: 5-6'/: 3-8'/: 1-0 4-0'/l 4-9'/, 1 5'/, 2-0 2-7'/: 1-9'/, 2-8'/, 3-4'/, 0-9 1-4% 1-1 0-7'/, 2-10 l-9'/j 1-7'/, 1-4 0-1 1 1-2 0-M 35-0 0-4 0-3 0-2'/, 43 1 650 3R3 2-6 2-7'/j 3-6/: 3*9'/: 5-6 5-6'/: 4-7'/, 5-6'/, 3-8'/: 1-2 4-Q'/: *-9'/, 1-5'/, 2-0 3-1'/, i .9'A 2-8'/, 3-i 0'/i 0-9 1-4% 1 .1 0-7'/, 2-10 1-9'/, i-7'/: 1 -4 0-1 1 1-2 1-0 35-0 0-4 0-3 3-2'/, 48 1800 1JO lb American Standard flange. 6ght % In. bolts, 9`/j in, bolt circle. 3R4 2-6 2-7'/, 4-0 'A 4-3'/, 5-6 5-6'/, 4-7'/, 5-6'/: 3-8'/, 1 .4 4-0'/: 4-9'/, 1-5'/, 2-0 3-7'/, '-9'/, 2-8'/, 4-4'/, 0-9 1-4% 1-1 0-7'/, 2-10 1-9'/, 1-7'/, 1-4 0-1 1 1-2 1-0 40-0 0-4 0-3 0-2'/, 53 1950 3RS 2-10 3-0 3-6*/, 3-9'/, 6-1 6-2 5-2'/, 6-2 4.1 1-2 4-5'/, 5-4'/, 1-6 2-4 3-1'/, 2-2 3-0'/, 3-10'/, 0-1 1 '/, 1-9'/, 1 -3 V, 0-8% 3-2 I-9'/, 1-9 1-4 0-11 1-6 1-1 35-0 0-4 0-4 0-3 58 2250 3R6 1 3R7 2-10 3-0 4-2'/, 4-5'/, 6-1 6-2 5-2'/, 6-2 4.1 1-5 *5'/, 5-4/, 1-6 24 3-9 2-2 3-0'/, 4 6'/, 0-111/a 1-9'/, 1-3'/, 0-8% 3-2 1-9'/, 1-9 1-4 0-11 2-10 3-0 4*10 5-1 6-1 6-2 5-2'/, 6-2 4-1 1-7 4-5'/, 5-4/, '6 2-4 4-5 2-2 3-0'/, 5-2 O-ll'/j 1 9'/, 1-3'/, 0-8% 3-2 1-9'/, 1-9 1-4 0-1 1 1-6 1-2 40-0 0-4 0-4 0-3 65 2475 j . 1 | 1-6 1-3 40-0 Q.4 0-4 0-3 73 2725 3R8 2-10 3-0 5-7 5-10 6-1 6-2 5-2'/, 6-2 4-1 M0 4-5/, 5-4/, 1-6 2-4 5-2 2-2 3-0'/, 5-U 0-1 1'/, I-9'/, 1-3/, 0-8% 3-2 l-9'/j 1-9 1-4 o-l 1 1-6 1-4 45-0 0-4 0-4 0-3 82 3000 3R9 i mo 3-5 3-7 4-8 4- J 1 6*10 6-10'/, 5-10'/, 3-5 3-7 5-4 5-7 6-10 6-10'/, 5-10'/: 7-2 7-2 4-6'/, 4-6'/, 1-4 1 -6 4-10'/, 4.10'A 6-0'/, 6-0'/, 1-6 1-6 2-1 ? r~ 2-m 4-3 4. 1 1 2-7 2-7 3-8 3-8 5-0 5-8 1-1'/, Ml'/, 1-6'/, 0-10% M'/, Ml'/, 1-6'/, 0-10% 3-7'/, 2-3 1-9'/, 1-8 1-0 3 7 y, 2-3 1-9'/, 1-8 1-0 1-8 1-4 35-0 0-6' 0-4 0-3 82 3375 1-8 1-5 40-0 0-6* 0-4 0-3 90 3650 3R11 | 3R12 3-5 3-7 6-0 6-3 6-10 6-10'/, 5-10'/, 3-5 3-7 6-7 6-10 6-10 6-1 0'/, 5-1 0'/, 7-2 4-61/, 1-8 4.: oy, 6 0 /, 6 7-2 4 - 6 '/, 2-0 J-'1.'1/, 6-0 /, : -d 2-1 1 2-1 1 5-6'/, 2-7 6-2 2-7 3-6 ~ 3-3 a-, 1-1'/: Ml'/, 1-6'/, 0-10% M y, Ml/, -6/, 0-1 0 % 3-7/, 2-3 1-9/, 1-8 1-0 3-7/, 2-3 1-9/, 1-8 -0 1.8 1-6 45-0 0-6* 0-4 0-3 99 3850 1-8 1-6 50-0 0 6' 0-4 0-3 1C7 4200 Kewanee-Ross Corporation KEWANEE, ILLINOIS 19 !.r.,, ~r i- Round type("R" 4;sizes, v . .. 96,000 to 216,000 Btii 40G.toy00sqft steam 3,r'.r 640 to l 440 sq ft water '!l , Hicher comfort st/ndnrds, for. himei .with m. .Jvrn deV:, su'ns tejturini; cn Limed window are-is .'.rid in r.indi. tvpus. 3. ' tarf.more Tniit-anJ 'w'ail arvus.v *: ,.im;*`*<c .i ua:Kr: iKutir:.: : , problerri'on :lie`Sailer. This ` prohUm; :<, nxt. c-'mpLK-iy hv Kcwance Round, 'R." ,^ ^ ',;Sturdilv^ built'I't heavy ,it -tii.' n' ;1-. S V {nuriv.extra'vejrsy Features unus'u.il .`ependahslit'. ; . cc*-rv .'iiiy. . . v(w;ith i capacity- to handle.l.irav . !y \ Capacious steamspace holds a .':oc:^ n s \. -steam, tor",unusual demands i' . .yfKy.> ii K. ,:;:J "R" can be* fired above its .rated capacity ..nd .v- rv;r...v' to operate.Avitn efficiency: ': % Two-pass tubos, provide 'longer travel - the ':u\\ , aascs rctainin^them m the bi,iler lihtti ..ii : ':'k- :k..: is transferred to the'water.,'Spinner Blades '.v:r! gu'es". 4. -.againsc tube, walls assuring maximum iK.it ::..;''t\r. Well insulated sturdy cast iron doors. Rue 1 door and'tfarne are precisinn uround and with i:' ' asbestos :rope' casket tor a permanent gas, :;g'ir 'rir. 0 Large; high firebox proNides 'urhcient 'pate for ` i gases'to mix;with oxygen and burn completely. : ' shell; of extra heavy steel btiiler plate, is cyerlacihsly ' welded inrb.,one'piece,, ready .to set on its ha^e. rrWide, free"waterways assure .r.ip.d i-i:^uiar!..n. sweeping steam bubbles quickly and with* ut o .rtn-ti- n upto-the .'unobstructed release areaar the a ati.-r -imr -' O'! /Heavy 'Steel base^can- Yfake-jt/' and. jJacket/.base may beswung arounJ to';j:v tr*>m'rr.'nr. /``C. rear, sideor.'anV angler1 V,)' S'1- ' , ; >. -t>i ..*!, -* \ ! ; Domestic hot water coil,>raiaJ in -bronze t:t* . ' ttinus: ;ind .mounted tm1.,steel-plate Wth .'h^knuiv.anl! , , rubber ,.ua>ktts.;*provitJcs*'.implc hot `Kvater 't-r Vitd'tn . laundry'and hath. . * '' ** '* . ' i .'.s< ur nr, u:J-,.; i:j .irf ratings mechanicall y fired -- oil, gas or coal * , H1', ' ' 1 * boilernumbef S8l net rating .connected radiation plus not water load) ---steam or vapor .. > --water --Btu per hour * ^ *a ft , *9 Ft ,i :oo'i firing rote--oil gpn* . --gas 8tu per hour --^TOker** healing surface furnace volume firebox volume, for stoker firing safety voive, capacity , loob'i - !b oer nr sq fl Cu ,, Cu ft ib fleam aer nr X t73* 400., 640 ,96 .i , . ' h 180' ii 24 44 ` 3.7 1 20 * Fuel burning rates based on 140,000'Btu oil. ** Based on coal having 1 2,000 Btu per !b as fired. ` !73d -J I7J7.' '11 '.'"`.ssoi,, , , '880* ' ' i ;s - ; ' 700 *. .1120 * ' i , : : .'68, ,, . *, ' t ; ' . .90 3 ,, 440 ' .. 216. *' - - ;T ' ' *'4-248..^ lr.\ ; ,,315 y 28 . ' .0 3 ' 4-35 1; -> r 5.* , - 54 L__________ ______________ 0.9. ' 205' . V 5*1- * >, . l- . 3;9. ; -it'; * -' ^' -:'5 ' , *" ` `: w \ ' '' . ' ^37 nf furnished for s*oe' ''.Vq `-V .r . *, . ' IA Standard eqwipmanf--Spinner blades Far oil or gas. Soot and fiue scrapers. V' , Standard trim, stearr--Compound team ond vacuum gage, water qage. wo 9age' cocks, V* in. saFety voive. The,extra 1 Vt in. topping in top of boiier moy-'oe .sed tor ' pressure control. .<* . .* |l Water-- Comb.nation -altitude'gage and thermometer. ' " ' ' 1, |w - ." , * ' , ' v.`* ' ! 20 ' 1 . ' H/ , -------------- K 3" SUPPLY 3 SUPPLY ^ : i :o1" ' I I i 1t -I 2r" -- -------- B------- - L dimensions and data (feet - inches) boiler number unjackeled equate jacket (o*l or gat only) round jacket boi(e d.o-neter firebox--rnude diameter --average neght A--heig.nl overall 8--bose diameter C--water une height D--o'e' cod connection he.gnf --jmoxe ovtlet--height P-- --diameter O-- --'o ocner center H--'ear clearance--oo'ier a wgd J--Poor o oottom zi rr-dosr K--row-id ocket diameter -- \Qua'e 'ocuet--wta**> l-- --<engh m-- --front clearance N--mi.-nym burner tube length .. . , O--comowston chamber--length, i-iude. --width, .rude A,-.e --height Ovtt.de jurtcce to cover, aniocxefed approximate weignt--umacketed --acketed Q --OCketed J i ! ' >Q ft ! ! lb i ib | * Coil connection uiei: 1 m. pipe for two owtletj, J/4 m pipe for four o ctets. 1734 I734MQ I734J 1 -M % '8 i i3 A-6'/: 2-2 3-3 3-5V, 3-3V, 37 t 61-* 3-6J'i ' 7W1 < - ' J/4 2 !I 3 ai'j ' - : 3-8 C-1 ! ' y/} ;i. i 33 0 24 800 ' 30 335 t 735 1735MQ 1735J 2-3`/i !M 2.0 4-IQ 2-5`/j 3-1 i 3-6,/j 3-3'72 :.5 i.ay? 0-7% ' -3 2.5'4 3-3 4.1 1-6 0-3 1-305 0-1 0:/: 3-8 '-0 30 0 35 920 1200 960 1736 1736MQ 1736J 2-6 '/i 2-2 2-2 5-0'/: 2 8'/] 4- 1 3-' O'rj 3-3V* 0-9 .' ! 0-7 H 5 3'/? 2-874 3-6 4-1 l 2-1 3-9 1-37: '-3 0-3 '-0 35-0 4t 11 30 1450 l 175 1737 I737MQ 2-6Vi 2-2 2-2 5-0 l/j 2 ay, 4.1 3- 31 : 3-3 i 0-7 \ ' - /: 3-6 4-1 1 0-9 ' 3 '3 0.13 1 ; . 40-3 47 i 430 1700 Kewanee-Ross Corporation 0*>na e* Amnten tod>er ft S'ondar* Seniery KEWANEE, ILLINOIS 2t VT510 Cottage Boiler ... oil or gas 77,000 Btu . . . 510 sq ft water The Cottage Boiler is Kewanee's answer to the lone standing need for a ; Heei bniier for small homes. It provide* i :p. outomMic hneJ hoi h .in-) re.it . . with ample Joir.estio hot water tor kitchen, laundry and bath . . at a price witk.n the reach of modest budgets. In ns attractive steel jacket it cK.-ries a space only .'ixb in. Though rated at ".000 Btu. it :s capable of carrying 50'f- more than its rated capacity. features A Hinged double cover on smokehood provides (.Jsv .iucm ) tubes tor cleaning. 3 Tappings m boiler shell provide tor all automatic G-ntr -m C Domestic hot water coil made in one unit. .Itiiu ;;-n!.ss . r storage tank type, easily inferred any time through t^p \-aJ. o Vertical tubes with Spin walls thub assuring greater h< : >cruh hot Hue aa^s rune .n>tcr without dirking ti.e Jratt. High firebox permits tho- transfer. irhwtc.n or tuel and '.rid heat f Heavy gage welded steel construction h>dn.Matu.ai:y tested at 150 lbs. for maximum water working pressure of too lbs. G Sturdy cast iron fire-cover plate with free r.wnuing purf- back safety swivel for observing flame. Refractory lined :> pi.-.nt warping. H Universal flange fits practically any fijnee mounted ui burner. Square mounting may be provided tor gas burners j Stainless steel combustion chamber <oUpx-up tion of oil. Installed eaulv through nredoor opening. >"h > :< Insulation refractory fill-in keeps door cool and h ikr eat inside. Standard ecuipment--Berner mounting flange.- {Dinner blades n me eo>v tubes F*ue icrooer. Standard trim--Combmtion altitude goge and 'hemonsttr, stamlett siee' button chamber <0' o-l-firing suppled at e`ra cast. -jcqe cc-n. ratings and dimensions (feet-mches! bailor number SSI net rating (connected radiation plus hot water load} --water.......................... ......................................... iO ft --Btu per hour . . 1 000'* firing rate--oil gpn* --gas Btu per hour.. healing lurface. fi'ebo* volume. .... c"imner*--nite . , 1 O00`i . sq ft cu ft --height above CL smoke cutlet smoke outlet to boiler center. water coil connection height** , , . .. flow connection height boe--diameter top ring door clearance. approx. we<gnt, lacketed M. . 'b 'Fuel burning rate based on 140,000 Btu Oil. "Coil connection sites: V\ in. tankless. V* in. for storage tank. VT510 510 77 1.1 1 44 19 2-9 0-8 * 0-8 1 2-0 0-M% 4-3 >A 4-1% 1.10 650 22 VT510-U Cottage Boiler-Burner Unit oil fired only Now the very efficient Kewinee Cottage Boiler (described on opposite page) is available as a Boiler-Burner Unit complete with an .ill-star cast of accessories. Built, assembled, tested and substan tially crated at the factory, this complete unit can be moved onto the job and installed with minimum time and labor. The boiler and burner, all controls, pump, safety and relief valve, etc., are quality products ... all having "won their spurs" on thousands of installations. Standard equipment includes: A Air relief fitting eliminates anv accumulation if an m -:w h.i.'cr nt system. B Water relief valve is ASME rated to open at a pressure a 50 !b. ... an important safety (actor. C Draft control equalizes variations in draft and saves tael S Stack Control a safety switch that 'huts off burner m , t .am- `.ion or dame failure and prevents operation until manually set. e Theraltimeter ... a combination altitude, pressure and tem-eta- ture gage. F Domestic hot water coil for tankless operation raises the tem perature of 180 .gallons of water 100 per hour. G Blanket insulation one inch thick conserves heat. H Circulating pump is precision built with oil lubricated beatings and thermal overload equipment. Silent in operation. I Oil burner operates smoothly and quietly while providing perfect combustion of the fuel. K High and low limit operating controls operate :he burner in accordance with the temperature of the boilers water. A visible scale and external adiustment makes regulation easy. L Room thermostat either line voltage or low voltage with relay furnished when specified. Jacket: Attractive steel ucket in ureen enamel completed encloses the boiler, burner and all controls It viccupies a >pace .-t onlv 251: x inches and is less than 5 r'ect in height. The minimum ot 12 inches needed between back <>r boiler and nail permits installa tion almost anv place. ratings and dimensions (feet--inches) boiler number $61 net rating (connected 'adiction piut hot water load} ---water... sq ft --8tu per hour 1000't firing rote--oil gph* Heating surface... firebox volume tq H cu ft chimney--sue... ............ --Hetght obowe CL smoke outlet... water toil connection tiie. *Pue( burning rot* bated on l 40,000 Btw oH. VT910-U 510 77 l1 19 2.9 0-8 1 0-8 12-0 O-O'/j Kewanee-Ross Corporation Ottilia* *4 Jvancja 4 jew, cwene, K.EWANEE, ILLINOIS 23 *4 Tabc__i_s. Jcrol #^^S;_*t< a*;. direct-fired water heated oil, gas or hand-fired coal i ' ^i* '' \ '** jT X ^ ' iJ V1 ^ !,, rs` - - . t ', i * '''.Wliiilemanylwitfer theaters are'r.xted' on .theit 'ability to r^i^e;, ,'Water,temperature; 2'5<=i`per-h6Ur;'tabasco ratings' ire based ' ^prii'a. nse bity.50;so-they do' twice the job. '-; 1 ' lf1ri ' 'J'.V , Vi : ,` ^1 ", , ' ,'','Bui|t|df?;nigged steel - plate,5;:heayief,ithan ' code,, reeju i re ments. , jijandrconstructed {for elOp,'-lb forking pressure (hydrostatic- I'test pressureridf,'' i;,50jdb)^;,Tjbasco`\'i'ater 'Heaters' ...v'amply; ^strong-to stand ;tKe, hich pressuresibffcity water mains. ,, , ,, . 'ail'' ,"* % Y\'`! IS l, s:'r' i -' 'ij;fr*'v- - v i^V; . . .`sWitremosK'bf .its,primary hedtine -surface 'directly `-over-the -`...-t'X-; r.' *-`v, ""-c.r, " 1l_/. j;" ' . . . v/. ' ' ;,'v` ' dire;,'Tabasco,..,is. a ifast- heater \yhilej;beih"c^econornio.ii', m 'is ' : use 'ofiueld a ``Vipv-''' ,4--` ` ' -Vf;'-'1 : rrv -V$F' '4f,i/^ll,'`cast'|.parts' 'are^uriusually.'heayya^Arid (if |h;..!'-' nred.,ep.ll,' pi^u^^tffe;^uma^^^rl!'ii`:l'ar^e.'leriougfr-so'i'regular, scoop--. :! .ftfshtivelxan 'beTusedXs i*rnany thousands of installatiohs.prove, .i:;;!',a Kewanee1'.Tabasco* truly ` "stands'? the, .ealf," even -when a:'--!P-v v^yr-, 1 roughly used. ..... ' - J- HJ'W: vH' VgV fc J - I .~ ' ratings-. X:. k[_ Mtr numbart'. \ - f f Oil 'oai L0V 030 ' 032', 7;;x ' -1 Ji li ^capacity hot woler,' SQ'.ntt :.*' ^gph 165 ` 250 400 550 700 1 j" firing rote--oil g ph* `. . . . ? . .r"! r .7 U ' *1.7 ' ` 2.3 '33 - rlfe -'X `-^-gdl,Bfw per hour,.1 OOO'l 98 154 V 238 322 - . 420 ' 1 grot* OrooVih',-'!-'.,.i ;'.r ,*d ft. 0>6` 1.25,;- 2.1 | 3.2; fuel bumingirates bosed onH 40,Q00 Btu oil. - ` 3.2 '_ dimensions and data (feet-inches) , A'--ihsfl.dlbmotsr... 4 .i", . :v^ 1-6,. 3 "O-p "2-1 2-7, a 2-7- ba* diameter. .... ,<8. * r.7 MO'!' 2-2 2-8 l 2-8 f D^iat*r height'..'.., a. s, : '`^1 4-0 4.0; ,5-0 - 4-10 .5.6 * , , -i 4; 6^--smoteV ovHet diomerer.: -* ,,F--ftrepot diomotor . .'^. v1. . -,i.- ^ 0-4' -Mr* 0-8 * 0-8 0-8 ' M }/* 1-4. 1-8 , 2-014 - 2-0V4 ,, ' -G--flredobf]Opening in.hatr^-width' o-e'/j 'O-S'/i '1-0% '>1-0% ;i o%: H-j" }t"', ^ l'l`; y`-'a *--tie*ght '0.8- -a s*9; , 0-9 ` '"'0-9 flow size. *. - ^ . .0-1 % '0-1.16 0- 2 ; 0-2'/j '0-2`6: * r:* retwni size. *.> . o-i'A 0-1 'h 0-2 0-2'6 \0.-2V2. ' * cteonout plug size. r.-. X y;. .- * -1. ; 0-1 'h 0-116 -0-2 ` 0-2* 0*2 " outside surface to'cover.. . so ft My 17;, r 27 ^ ^'32... ' 38 * I , approximate weight--heater shell', .lb 290 350 -^toase and castings'lb 140. 180 vi.. - '"otol.'.1. .r..*K". .'lb 430 530 V-'I/'"1' ' 'v>:. 620 ' - 800v 980 220 - 300 290 / 840: 1100. 1270, ' * '"< i' * ; ; \\ r > '; 4, ' * S* ' t" v, > ' i ->- a "J iJV 41 4] ! ... 1 . '1 - ~J` r,~ -V h :5<, ; -- *if s' i - s 1* _ 1 j," ' - , i . - 1y : -1 ,. ivt;- r .* ^ - : 1 j. . s', V-' ' 1V , . '' , ' .. _ '1 H i ';TL `V '-'i ;1 '1b . `V't, . r.X~ , . X . v . . > . '1 j'-1: ''`itx : ' .0 J. ' ' r ' - . 1 X !4 `1 _ ' i fx 1' 1 ' r* ' i V c d *v Cottage VT510-DW . . . direct-fired water heater 140 gallons . . . 100 rise For an abundance of hot vvarer f.:<t the Kew.tnc-c Cortace Boiler used as a direa-rircd water heater pros ides a most un usual performance- Teamed with any pood oil or ,-a-. burner it operates with a surprising esonomy in the use or tucl. er ;t requires very little floor space. Enclosed in an attractive steel g.icker it Is only - \ > n. m.: less than o ft high. Built according to ASME .--de. a s tested with 150 lb hydrostatic pressure tor workmc prv"~.'c> up to 100 lb. Easy to clean: Simply remo\e the S bolts, r,, :hc cover plate and tubes can be reached for sc.iie rcmo-..i . . also the top of firebox. An important feature p -....A t es where water conditions are adverse. typical piping connections (diagram at left) A For most rav^.-able circulating conditions stor.uv tank aid be J 'I f -'! placed a> man ibuve the heater js headroom permits. FLOW SUPPLY 'NLET C-'Id ^uter 'i:rrlv -h- uid L-ntcr mor.iltv tank through pux ,1:.:.:,": t> within 6 ;n. r b<i?t',m. RELIEF -- .-- --------------------------- ^ Return circulating 'me between tame and hearer mould mv:' ; VALVE g i \ STORAGE TANK = b'-uom or k > pp< site Cold -water inlet. Hot water Row [me -should connect at either end or ton nr nk Return mav connect to the hack the heater or to any "tiler "t the bottom "pemngs. "-m ,. . . 11 COTTAGE 1 BOILER CIRCULATING RETURNS ratings boila* numbtr capacity tOO* riaa gph 100' Ha 3 hr oil 9Ph* bring rata gat btu par hr I| : /r*\ <(^> [j - 1 RETURN j pRAIN L VT510-DW 140 420 *Fual burning rott oaiad on 1 40,000 8u oil. dimensions (feet--inches) 1.1 144 ;:o k bailor n urnbar hght Igth width P<r turn tmako avtlat da chimnay tiia ! tight vr5IO-DW <* Ml M1 0-1 Vj 0-1'/: 0-7 0-8 * 0-81 16-0 Kewanee-Ross Corporation O^i--i i A*--*-- IiHW fc V"4ar4 fc--nan1 Cara KEWANEE, ILLINOIS 25 4y **i r. J`> ` * "r* - '7+ '-'2 ' f: a*W V.:- -V ,5 *\Y.*s storagewaterheaters-r-,-----------t.-, , - 1 m'v' *1ij.t..*....i.; V ,- ':>> : ,1 .V '; i*! r i4* .ifss.fli \ ; -i .*. j*' , i ->. . * v. . tVl*1*, i:,j r ., ,, v, here; varyingjauanrities ot hor.water areuised.'it- irreeu*'* . -r r 4 .. ', H' . lar( and^exhjusti.orJli>c 'sti*amfis/.ivj:!iiMe.; ,4 -i)* l *" V .^Kew<%a0w%AeA SW'S^1^ritgI .e^^Va\ t4c* --r^ivA ^ I'eLJa-tiAef.asAA-^* p:. ^niya ai.d. eJ .k^ \T..\cr_v.!* t i v'usetfuu!!',i<efvicer?\\*ith^^cJtiric' culs cipaNct-jflHc.irini: <>' *:n- + % ,.*v wirv^;, ir't- >- ,. v .' . - to 6000 &Ub&I6t`">-1itc'i?KrilfeVr'-<Vai''in^tc:v.pvra:uV<.-`t. .MJ-l., if-i'-'-t ", | ;j, i . - '- *,'*'' vi W -'i ' , ' . , ,, , i. , *1 v-.jfk'imT+J.^up^to.^ tank*. -tV \r * ^s^ll^ns^capacityjvr' .water 'Canr'^bc/ hc-atcrd *j'nCj;.'w^ {in'uiared^/*' - insuring! a^ WirhV aj:^r>v'.i(cining; ' v'.-rln`vi<J^on?fhe boilers. < r <thcr >tv.ir.'._A` ' /it SVuj.'.,' ; r , t s ,"f t'lri!' j ' ***. r+* V' * i -,'i capacities and dimensions , '*' The-heatint^fdcinent;is cunsrruacd >i>iic.i\:;-.'2.v^ v'-p- * 'perstubin^iberir'intovjj L^shapc. which- tako^arc*P r .fnv h' ^expansion/of^the,,tub- in^>crMce: !* . roiiedi;ihro^hhe^tube^ihWt?and,':held j'n'pl.ict oi:urW" hi,. '"r;;-. w.`> ^'i..lV-;'. - ^ v - ,^r-T portipljtesvfoi1 prevent'1'Vibration jndx:.\\'e.irnnt:' - V^" *':?*-& ;* :"*-.\V: ! a , ^ ty ''f.e.Is'4 ?naore.*:iaun^fternneaahvvtvvef.,a:s-.sd*keres,tisgfio,-r.a^icocmurtTa^*tteO!vrl,emaj,ka".e-n:t,,m-ed-,:1'Lainti4' t'..M>' rc'are>.`r a~V.s, '.^'- r\j... < I1 ,->'V' '-..V ` fglP ,";Jj j;\. ,4'! T' r./ '.. *',V'>'., .-*,v.!.. ;*. Th^s\'eryfwidei range^ofi capaci ties, chunks'^anci^heJtin.q *" < > ^coils''mak'^ iit*ajmo>V>iiny operatihg? cJndi*'. ` iUon. with one d^tHese sMndard'units. f 4 ^ ^ ^'v; j ;tVr ` V'T . T't- 8' ' 1* <-(.r. '.Sit.*'' ' `vV' Ji . fcj J0f_. c -v.v -- ' --tShChTtS X .S.-I - >i ~ COll data (feet * inches) heating ceil tixe end no. A---2.5 A--5 A--10 B--15 B--20 B--25 C--30 C--40 0--50 0--75 0--100 e--150 6--200 6--250 f--300 heating 1 cep. OPM 40' to !MP ' with steam et etmetpherlc'' pressure ; so 1 100 200 1 300 i 400 ' 500 600 ; 800 . 1000 I 1500 ] 2000 i 3000 4000 5000 I 6000 - 1 ] heating surface sg ft 1 i.i 5 10 15 20 25 30 40 50 75 100 150 200 .250 J - 1 '300 horttontal tank min. length 1-6 2-6 5-6 4-8 .4.4 5-6 5-0' 5-0 5-0 6-6 B-6 7-6 9-6 9-6 v 0*6 Oponingi 2'/j in. and tmaller ero pip* thread. Larger openings furnished with companion (tango. V blo*-ar..p ->A>f3ot O-*o>u>i*l: steam ' inlet outlet 0-2 0-2 0*2 -* 0-2'/j 1- 0-2,/i'- 0-2 0-4 0-4 1 \ 0-5 * 0-5 0-5 0-8 :0-8 0-8 0-10 0-1 t o-l 0-1 o-l'/. 0-1 V*. 0-P/4 . 0-2 , . 0-2 o-2'yi ' 0-2'4 0-2'/ 0-4 0-4 0-4 0-5 * 1 ' v , : ': tank data (feet . inches) *ok .{ tr9. ,.->tank<iiio ' ` ,htr' , >op.r I* . r no. gal.. dia . Igth* 91-J * 'i' i 'J ,:v4v I. ".f ) ,v , ^ ourtot | blow*lH ` off ` .bwiil.*; tap ' J_. tl|V 2404 2405 2406 2407 `3005 3006 ' 3007 .t 3008 1,5 2-0 *'-'; 4i0' , 1 ;2 * , 2-3 r2.0-i 0-S'/. :o-2'/,- JOv'V,. Cr-Vl ,r'l- 1 18'- 2-0, *`5-0: 2:6 > 2-0u 0*5'/i 0-2^ `0; V/t - 5-1; ^ ,141 2-0 S 6:0 1 1:2.,* 3:0., 2-0'4 0-5'/el 0-2'/j 1M - 164 2-0 * i7-v0 >-2 V - 3r6; , 2-0 o.5'/*>o:2,/i.' *,,0-1 ` 180 2-6-s ,5-0;' , I-41 . 2:6 -c : 2^6 ` 0r-5*/4. 215 2-6 6-0 frl-4 3-0 i 2-6 0- Va . 255-#!;J2.6<-!7;0. i,l-4^ t3,4,!- -2*6 285; 2:6 *-'.8-0 "'^1 ^4.0 - Vl2-dr. 0-5 Vi' 3*2'/l*. o- ; o-i ,J 0*2'/j'1 '0-1'/,.. t"-M '' ;7 0- 2 Vi,, `0-1 Vi. 'f . 3606 - 31 o`y- ,3-0fc* `6-0 ` t8J-ov ;,3-'0 0-5 V4 ^0-3; / 0-HV .*,0- V - 3607 .1 385>..i. 3*0s i`n:'7-0lf ^l'-4''!> .r3i68! *hQf 0-5% 0 3 d- IV2 i o-| :-1 3608 .. \ 415 3-0 8-0 VI-4.` {3:0 0-5% OO'i, ``O- l '/j * v0-l - ' 3609, l" 475^ j!o r ,e-0i :,i.4^ ^4r6*i. ` 3-0 . 0-5% "0:3V"" (0*1 V{ >3-r. ' 3610 >: 500j'4 3f0* lO-Ot] M;.4Vv 'so. .{3-0;^ 0-5% 0:3--f :o-j.vi - >m: 1 . '[. 'it ' '| '! 4207 " >500 ^ 3-6 * ,7*0!; ;! -:4 ,s3-6lr V3:d'V 0-6H 4208 575 3-6:.*>8:0!; $: *;0 !'3-6^ 0-6 Vs -2 . -i 'Sw 0-2 f , '4209 650> 3-6; i*' ' 9;0 ;4-67 l3E4;-iO-4% '0-3; ,4210 `-720'.: 3-6 * lO.-O^ iM-4'V 5i0- ,3-'4-,,l6(r4W 0-3 d-2 v. tO'-l'Vxi: 0-2.` `3- IV.,- -4212 . . = 860?, 3-6 1.1 2^0^. W'*'t '6-0 r 42 UX &.! oop^f 3j6 A.i4^p- *\\a ; .7:0: 0.-6H 0-3'i > '0-2il'.v J.` > Vi 0-6H <p-3 fO: Jp-2 ' yt ' O-.V'/j, 4810 4812 4814 .940 ' 4*0. i! 10:"0i- :i-6- 5-0> i'iiOl'- 3,4 y. i0-4i,'^ A%-2'/u i.O-.r/j' ?H25,V 4:o?k,i2-o' 6-0*-. U-02'7 0-6% o-er.S |-o^2Xi ' w.-v .13001 Arp^i^O: -1:6"1 '^oj 1'4-dV 0-6% 0;4:. 3-2!/i ..m3-,! 7* " <*>* 0 ,0 5410 >190^ 4i'6:*^o-o: ;5-0:rt *$6' ' 0*6 / i i0*2'/jv 5412:' :U25'? 4^6^1 2-0 ; \:Ar 6;o7 **. OiA ! 0-4 i',.. ;0-2'/j 54 u*:, ,61.665 % 4ig j.vi 4-0; ,1 -6$ 7-0'. JI3-67 0-6 0*4- , l0-7Yx' 'i . .. 6010 6012 f400 " -1700- * j1 - - 6014, ^20001; 6016 - >-2240n 5i0id-0i ' 1-~8. 5-0 * 1 2*0'^ ;-l-85*0 > 14-0 ;;1-8 5-o:ri6-or; t>8, 5-0 - 13.60 0-v6l h ;o-4 ' 0- 2 Vi : ^0 V ;3-6 ,` OiAVj 0-4, ii0-2.'/jS v: 7-0 :3*6 0-6' 2 d-`4'.-'. .O^.'/j ;'td-i '/j-c 8-0 "t 3-6 0-6-' '0-4 V I 0-2V> M7| 1 .j- -- * eh'. ^ s - -v. 1 ...'1 1,- 1 v 1 , e1" v, v t'-/ ^ . j, ' Shell openingi.'ASME.codb ovor^125 Ib swp and.ovor S in. 'diameter, ore^nanged noulei. > 26 ji,. ' ;.? ' M; ` H ,l* , k.b ` irK' Mr ' * ,4;vf ' -` J fans for every size boiler ^"hen you are up iL\imst a Jirncu!: -:avk rr-b- 1cm. yi'ur Kcwjnee Boiler can be turni bed with Complete inJuced draft equipment. These anas are designed to proxide con^ant {.ilrhouch .idiu-'t- jbie) predetermined draft for Rulers. K>tn huh and low pressure, and will idwand Hue e.ix temperatures up to F. wic:m maximum r*-m temperature ot 1J5 ' F. Designed as a ''straight through" unit, these in duced Jratt fans are ca>ilv installed and L.m be mounted m anv position as .1 H.ineid M.uion of brc-eUnnq or stack. Not onlv are these units low in -r d quire minimum maintenance, but pto ,0 rum boiler efficiency at all loads, rceardkv' "t w..,t;:er conditions. For further information and cc-mri in duced draft fans f.>r KcA.inee Bod. - o ns;.,: -..-ur nearest Keuunec bales Otfice. Illustration at loft shows (top) two-stage induced draft bifurcator with 3-phase variable-speed motor and companion flanges, (bottom! nine-step speed controller, magnetic starter and push-button station. I Photo courtesy of Mlnneapolis-Molino Company, Kansas City, Kansas Photo courtosy of Nutrona Mills, Inc., Wichita Palls, Texas Kewanee-Ross Corporation V*wm l WiW tilliw & >Ww CawfN* KEWANEE, ILLINOIS 27 /.r.-t- }mLe -iM-'.st. :*i;' r' *' , , W Vt-f1 i.y..ik-v.Ar' J !J,, -- . V . ,*'/'ft;?* &. H fSj . -- ` .. '............................... t < \ v-.' r c- -- ^ ;a <',*' . . ,, ,<-,]/ j,, ,, i a . j' ty'S'vjf'tt'* V AA 1 i< < 1 V * ,, ... -j".v^'yy.vA .1kr- ^ '.V'; il - : ' ; for commercial firebox and V. scotch type, boilers i, p** KewineejboiIcfS.arelallrbuiltito^iccommoditeSiriJirOa1 water, > K r' t .........:<i;v w? ." l[ 'HeatineJx'6i!s' .:^r^ .or-`ihsuhMhcbWtvre-J: . . -* i ; : e* ' >': ! V ':; which can; Be-installed -it?the' factory'; or.at'te'r, tlie- IfoiIwr-' ist*v. . I'; , , v* : ; on the job. ' ij.vyfci'.'f" I ..' : 'Copper., tubingfd^j^ierous^sizei^brasecl..'into^ bronze. ;ritr:ns: ''.V vWi.;'enjs;'tapp'eii ^.witli^ standardl' pipet* tlarcaJsS' .r. Kxknuts' rfj; ''and" rihg,.gaske6Sfesj:t;v.boiIer$tcel^mounting blite v.yifi ',5'''%f ;>f,ff. !;",-w *,< y, uill: >.\< - ;*[>' S(Sc& sheeth)bber*(>askets"a.`. make, these coils emcient and..> y,.fe|j, -'C w, , I?' ' f-r f ,,i , r , 'i4 *nff.kft. t ,l-`s ' -' -^y ' ;V,r ;.-v' li In tables'^elp^the^symboi SR6-24*. means^a', single -row; or 6 *, : -.1., y-'- ,y `' 1 row ot! sjpipes {, .';]'42 inches .long.: .vy ii;' 'f *K" ' I"', r ** .' I>>' capacities storage ; tank operation 3:- . .-iS. : - f:' `U (i insta ntaneoiis'f'floyrl"V- . if.V .f-iVVv -' ` ! boil** } . number i 1 coil no- max tise rated cdpocity fotol gol.'.heatiM 40 -140 [ 3 hr* in botier wstor 212- F :,sl80 8 5176-78 5179 SR6-24, SR8-24 086*24 DR8-24 088-30 2 088-30 ' 90 120 180 240 320 640 55 70 UO 145 190 380 r 5180.81 088-36 2 D88-36 400 800 240 480 - 088-42 5182:83 2 088-42 480 960 290 . 580 5184 5185 088-48 2 D88-48 3 088-48 560 5 120 J 680 ' 1 1 335 .670 1005' 5186-88 5189.90 088-54 3 088-54. DR8-60 3 088-60 .. 640 1920 . i 720 2160 1 * .385^l 1l`55,, 1 430 1. 1290 ld' urfaca *' boiler number COil rated.,capacity ` j i .tetal aal: heated^, end max. ' 'in.boileriwater. tit* i/i212?:R f; - tetol > urfaeej. V; ^number ^t-4eil'4'' iV.-fA'.^eted capacity'" '' 1totol`gel. heoted-7'.!'V- L..11 v ' boiler(water j ,.* v.-4* .'f-^l hr-- < V`| min t , : 3.0 3.9 6.0 7.7 9.9 19.8 .11.9 23.8 14.0 28.0 , 16.1 32.2 48.3 . 18.2 54.6 20.3 60;9 11 7L80 0R8-66; OR8-72^ 088-70 2 088-70 : '800 -ft it- /*807':: j?" 22.4---V 880 ,- r ,530 ' ',940 - * {." ,575 V ,, 24.4,'.,n 50 ; ' 53.2^ 1 r"?rNr>\. f'V5220', , f,:> ; 3.7 ;,T. ,;-47 ,, s'. 4 w OON:i t \,'280i' y\ 'C,*:Z tk! 5176*^8 Vv QON-2 ,%"H0i,;' / ' .5:8-, |.,,23:4.,:>.. 5179*8 i . 2 QON-2. : ; 700 ; <} .;-i'i,6 -V-,;: 46.8 A' 7102 ' 088-84 1040 '625'^ - 28.7t't'i' 2 088-841 ->^2080>X >, 1250 ; K.J7.8S "..QON.3 - QON-4 r. v* *y - 10R8-90 ". -M 120 *; 670 ; 30.8 -ig 5182-85 3 QON.4 . . !< 088-96 ;-1 200'y : -^,7,20., 1 ; .',32.9-4 ; -4A . *1; -v OOI4-7 7L81 r*`. 2-088-96 ' .jaoba'"1! t`440.' . 65.8 ' .5186*88 3QON*7 y' 7183,84 `7L86 088-^32 2 OR0il O2 3 088-102 ,M 280,, ,* ;rV <77ov; H 35.0 1' i2560! ,s ifyuo' \ 70.0'" 3840 2310"' ^105:0.^ : .4, . 7180*85 7186*90 -`oon-s '2-QON-8 3QON-8 v: 7.1:0s -088-108 v H'360 r:t "'*8151 * . 088*114 iiiWI .' ` ' lS l2 DR8-1 W 1 >2880 rV l. ^ i 730 r' * %-37.l~39.2 4 78.'4,'*1 088*120 " M520.F'' : ,'io . * <40.3 7 7187*90 3 088*120 . .iMbtfi `2750, , 1 20.9* ` 5189,90 (3QON.8 ;C'n' > 1#\t`, t r . k' "<4 '* ;* 420 . , !:, '/490 A- f 1.* -j*..; 'U328:' \\ 1'470 24.4,;f|-.:V'7.8:' fre.'<. 8d0O0O>'-'.i \ -/I 0.3-/ 4-3:-3 i` >'io^'"..;,";r?20!3V<- ?>w700' ' i'j'iooi ' ,![:: i; ;21 31..47; wi'.4i.'x,,J4}6.'.*7' V` / 1:? 2100 t -,\35.r, --V, 140:1. ' ' V >2l00i !,,j 35.1 4. 1-40.1 .' ' \'j *. '4.4-',5" 1 h . K`. ^ ' a * Intormatien on coil* tor IM-800 boilori on oppflcaHon. ' '` ^ . ,T, Any coil *hortr thon h maximvffl natht liitod obovo may b* lubstitutod,in ochtboilr'where lou hot water eQDQcity it required.^- . Coil iniet and outlet tame tize iron pipe lap, I in, on TON and I Vi in.1on QON initantanacwsl alio l '/i^itv on OR.and il in. on SR troca'a* tank coiltilr i `;> * ii < *' `` y. ' , .V, ( ;, v "`J'f?/ /V' } 'i 28 ,, Jr-t.'1r~ yi'.l'y.'.A).-,-. .;3`ur-- - :" r,y /. '.<11 1 ' r x . i "I.-, ' -y-C--r'Tt , *s, j;*' 1 C. 1 l< :'' <.! . ' ,'f^ .t'.jr"! 'u. .. . "r.. i,, y': it. ,* r indirect hot water heating coils for residential boilers Kewanee boilers for home heating can be vuuipped with in direct water heating coils (storage tank or instantaneous type) either at the factory or after the boiler is installed and in use. All are made with openings to .lccommod.i: _- -tie hot water coils and it is necessary to remove only the . jrcr ng plate, insert the coil, md bolt it into place Kewanee coils for domestic hot water are Mib-tantially built for long, trouble-free use and efficient operation. The eonper tubing is brazed into bronze fittings mounted on a -tee! mounting plate with locknuts and gasket Coil ends are tapped to receive standard pipe thread. capacities storage tank operation instantaneous flow I coil roted capacity no. gallon* heated coil rated capacity no. gallons heated boiler ngmhet and max size 40 .140" 3 hr* n boilor wotor 212 F 180 F surface sq ft and max sue 40 040> in 180* bailor water 1 hr 1 mm surface sq H Any coil shorter than the maximum Square-Heat type 'R" boiler length* listed at left may be substituted . 5R6-2* see-2*- 90 1 20 55 3 0 70 3 9 in eaeh boiler where lest hot water capacity is required. 3R5 l DR6-24 i DR8-24 1 80 240 ;o 145 5 3 TON- 1 OOn. ' 2 20 2 80 3 7 i 54 7 4.7 i 8 7 3R2 3R3, 5 3R4, 6 3R9 3R7 OR8-30 088-36 OR8-42 DRS-48 ' DR8-54 320 400 480 560 640 190 240 290 335 385 1 99 11 9 4 3 ' 6.1 i32 son-: CON.3 CCn.4 CON.4 COn-7 --------330-------- J20 a 90 490 500 5.3 7.0 8.2 ' 8.2 10.0 . 23 4 28 0 32.6 32.6 40 0 Coil inlet and outlet some site iron pipe top, 1 in. on TON ond 114 in. on QON instantaneogs, also I 4 in. on DR and 3R1Q 3R9 3R*> 2 088-60 0R8-60 088-66 DR8-72 720 720 800 880 430 430 480 530 i *23 i! 2220.3. 1 24 5 CON.7 CON-8 COn-8 OCn- 8 &00 700 700 700 1 0.0 1 1.7 11.7 1 1.7 40 0 46 7 46 7 1 in. on SR storage tonic coils. Round type "R" boiler ;| ,; * 1 734.. 173S. 1736, 1737 A65 65 \ y 1734, 1735, 1736, 1737 1735, 1736. 1737 Cl 50 150 -SO 2 0 i 90 0 i 70 N35 210 5 1 U0 Square-heat boilers hove topping each side for external water heater, also on right tide for low water cut-off with plug. 1736. 1737 D20O 200 120 1 6.6 EN?6 250 2 . 16.5 Cottage boiler ---------------------- ----------------- yTsio V-55 55 i i 35 : 9 v. 1 80 180 3.0 ! 10.75 Kewanee-Ross Corporation Dwwob af Hantai *o4miw 4 Wwi Ceietii-- KEWANEE, ILLINOIS 29 boiler support brackets and structural steel suspension For :xin turnuic height (be;,onJ the code stand ards}, Ketvanee structural steel suspension oners a solid setting independent ot turnace brickwork. The gusset bearing plate brackets ;ne support tor setting the boiler on a separate masonry base. specifications boiler support brackets For Sow pressure firebox and T\pe C boilers :he sup per: brackets shall consist of two pairs of steel btarmg plates, each with 'wo pussets welded to the boiler at the bottom of the waterleg. Each gusset to have a 1 2 in. hole tor wiring insulation to the boiler For high pressure firebox boilers, two pairs of forced steel welded bearing plate brackets Jrilled for secure fastening at bottom of the waterlec with srud bolts. ' On inch and low pressure hrebox boilers the barrel shali be -upporred bv a cast iron A ' frame hackstand grouted Ti masonry pier specifications structural steel suspension Suspension 'hall consist of four steel H-columns with Marine plates. one pair each side of boiler jnd eight pairs ot r.ttved steel brackets fastened to boiler s.nely and to priwidr lateral stability according to AS*ME con struction code Each H-O'lumn shall he securely baited to two pairs of boiler brackets. On hrebox boilers the barrel shall be supported by an "A" frame hackstand of steel members and bracing with top saddle anj bottom beirmg plates welded into one unit. All Column inJ hackstand beating plates ha\e holt holes tor anchoring to inundation. (Anchor bolts not furnished h\ Kt-wanee.) 30 E E r-- ---------1 5"-0S in BEARING BRACKETS-TYPE C BOILERS BEARING BRACKETS-LOW PRESSURE BOILERS 1 Mi U BEARING BRACKETS-HIGH PRESSURE BOILERS D 1 TP 1i l SUPPORTING columns- type c SUPPORTING COLUMNS & BACKSTANO A safety valves boilers over 1 5 lb swp Number and size varies with valve setting. All boilers having '00 sq ft or less of heating surface furnished with one valve. Boilers having more than 500 sq ft of heating surface furnished with two or more valves. Manufacturer reserves right to use separate outlets or yokes as conditions require. boilers 1 5 !b swp One or more valves furnished depending on required capacity. typical boiler installations lift Dr. Pepper Company Dallas, Texas Two Kowanoo "500" series high pressure boilers (light Hotel Mead Wisconsin Rapids, Wis. Three Kewanee Square* Heat type "R" boilers left Saint Mary's Hospital ia Salle, Illinois Three Kewanee Hi-test boilers flight Ohio Form Bureau Office Building Columbus, Ohio Three Kewanee type "C" boilers Kewanee-Ross Corporation Kiwim t4*ar t SiwUn Carpar** -- KEWANEE, ILLINOIS 31 branch offices Kewanee Boiler Division APPLETON, WIS. P. O. Bo* 355 ARDMORE, PA. Suburban Square Building ATLANTA, GA. 955 W. Marietta St., N.W. BALTIMORE. MD. 2301 N. Charles St. BIRMINGHAM, ALA. 2224 Comer Building BOSTON, MASS. 127 Federal Street BUTTE, MONT. 909 E. Second Street CAPE ELIZABETH, ME. 46 Forest CHATTANOOGA, TENN. 720 James Building CHICAGO. ILLINOIS 549 W. Washington Blvd. CINCINNATI, OHIO 2107 Central Avenue CLEVELAND, OHIO 1401 Prospect Avenue COLUMBUS, OHIO 20 S. Third Street DALLAS, TEXAS 4411 Belmont Avenue DENVER, COLO. 1228 California Street DES MOINES, IOWA 407 Hubbell Building DETROIT, MICH. 12950 Hamilton Avenue phone no. 3-3 J 32 Midway 2-8170 Elgin 1226 Belmont 5-4161 3-4645 Liberty 2-3311 5457 Portland 2*7673 6-6657 Central 6-7525 Garfield 5252 Cherry 1-6911 Main 3544 Victor 0177 Tobor 4505 3-7817 Townsend 8-0684 phone no. EL PASO, TEXAS 600 W. Poisano Drive 3-1405 GRAND RAPIDS, MICH. 33 J Ottawa Avenue, N.W. 9-2352 GREEN BAY, WIS. P. O. Box 324 Depere 126 GREENSBORO, N. C. 211 W. Sycamore Street 3-2526 GREENVILLE, S. C. 104 E. Stone Avenue 3-7488 HOUSTON, TEXAS 1309 Anita Street Keystone 7431 INDIANAPOLIS, IND. 31 E. Georgia Street Imperial 6^76 KANSAS CITY, MO. 2014 Wyandotte Street Harrison 0696 KEWANEE, ILLINOIS 101 Franklin Street 4481 KINGSTON, PA. 303 Market Street Butler 7-4117 LOS ANGELES. CALIF. 320 Crocker Slreet Michigan 2363 LOUISVILLE. KY 300 W. Mam Street Jackson 5541 MADISON. WIS. 416 W. Johnson Street 5-2102 MEMPHIS, TENN. 668 5. Moin Street 8-0339 MILWAUKEE. WIS. 312 E. Wisconsin Avenue Broadway 1-1840 MINNEAPOLIS, MINN. Fillmore 300 Builders Exchange Building 6741 NEW HAVEN, CONN. 902 Chopel Street Locust 2-8085 Kewanee-Ross Corporation Dfv-Mn t rUw#rcw Had B*or A Co*p--o*ow KEWANEE, ILLINOIS NEW ORLEANS, LA. 816 Howard Avenue NEW YORK, N. Y. 40 West 40th Street OKLAHOMA CITY, OKLA. 120 East Main Street OMAHA, NEBR. 40B South 19th St. PITTSBURGH, PA. 1005 Empire Bldg. PORTLAND, ORE. 432 Pocific Bldg. RICHMOND, VA. Bellevue Station ROANOKE, VA. Grondin Rood Station SAGINAW, MICH. 2340 Mershon Street ST. LOUIS, MO. 2835 Washington Blvd. SALT LAKE CITY, UTAH 204 Dooly Building SAN ANTONIO, TEXAS 109 Barrera Street SAN FRANCISCO, CALIF. 637 Minna Street SCHENECTADY, N. Y. 277 State Street SEATTLE, WASH. 72 Vine Street SPOKANE, WASH. 2932 E. Trent Ave. TAMPA, FLA. 2925 W. Hillsboro Ave. TOLEDO, OHIO 702 Madison Avenue TULSA, OKLA. 15 West 10th Street WASHINGTON, D. C. 15th & H Streets WICHITA, KANS. 811 E. Boyley Street phone no. Tulone 7105 Oxford 5-1970 Forrest 5-7301 Jackson 7636 Grant 1-6425 Beacon 6197 6-2337 2-6548 2-4147 Fronklin 3406 4-6421 Fannin 7229 Market 1-3612 4-7822 Eliot 0230 Lakeview 1539 33*8171 Garfield 8359 2-1033 Executive 3-4044 2-3484 0 3 ) )