Document aJgnYD4yrr4R8M6kmVGyr7pbe

1 V AG Eades/GR Buchanan nd Street - Don Rousli H Gilbert NEW YORK-A Klemm/v/ Schalk' i CLINTON - GR Graham CHICAGO - DL Hosrner j_iOS ANGELES - D Erisken April 2, 1965 CLEVELAND - MG Nichols HOUSTON - Wm. Shaw RA Garcia - RC-ARC Mr. Harold Kaufmann EGA Rood Industries. Inc <.-5 Wes; 36th Street New York 18, New York Here is the "ammunition" I promised to send, justifying a synthetic organic fire-resistant heat transfer liquid over a petroleum oil for your doughnut fryers. Hirst, I know you will find safety and fire resistance a prime requirement for your customers. You will be at a serious disadvan tage should your competition use this difference in their'sales pitch. I would imagine the dangers of fire and explosion are fairly prevalent in large bakeries, especially considering an atmosphere of finely divided flour. An incident such as described on the attached copy of a page from the Factory Mutuals Record documents what can happen when a heater tube failure allows flammable oil to spew into the / :ire oox Second, as I indicated to you during our discussion, THERMINOL-FR is exceptionally resistant to oxidation. There is no need for inert gas blanketing of the system, and the expansion tank can be run hot or cold with no adverse effects on the fluid. This is not so with a hydrocarbon oil. Note the results of an oxidation test and a coking test that were performed by an independent laboratory. In review, samples were heated for six hours at 500F. purging with oxygen at the rate of 30 liters per hour. THERMINOL FR-2 measured a viscosity increase of only 1%. The hydrocarbon oil went solid. This manifestation is again confirmed by the Panel Coking Test; DSW 343162 STLCOPCB4083945 ..vm- Mr. Harold Kaufmann April 2, 1965 Page 2 SEVERS OXIDATION TEST (30L. /Hr. oxygen 6 Hr. 500F. ) Oxygen absorbed, (MOLS/426 G. Fluid) Volatility Loss, Wt. % Viscosity increase @ 130F., % Fluid Insolubles (Sludge), Wt. % Neutralization No. Increase (mgKOH/gm Fluid) Therminol Fr-2 0. 01 0 1 None 0. 0 HydroCarbon Oil 3. O' 14 Solid - 14. 7 PANEL COKING TEST (8 Hours) Mg. deposit ( 600 F. ) Mg. deposit (700F. ) 0. 0 11. 1 65.4 47 6 Third, hydrocarbon oil type fluids are known to crack above 500F. liberating, as well as other gaseous products, hydrogen which is a flammable hazard in itself and leaks of hydrogen are undetectable until XZ is lOO 13-tG* Fourth, petroleum heat transfer oils cannot be reclaimed as can THERMINOL in case inadvertent overheating takes place. Consequently the charge of THERMINOL, in essence, becomes a component of the system with "repair services" available. And last Hal, Monsanto is fully committed to serving the heat transfer fluid customer in every way possible. Fluid Specialists (chemists and engineers), handling nothing but our Functional Fluids, are stationed in the major industrial areas throughout the country. They can be relied on to provide assistance and service at any time to your customer. Also, a fully staffed and equipped Applications Research Group, here in St. Louis, is available to tackle any special problems concerning the fluid that cannot be handled in the field. dS3163 STLCOPCB4083946 Mr. Harold Kaufmann April 2, 1965 Page 3 ' .' ' j Again Hal, THERMINOL-FR is the only heat transfer liquid with . Underwriters' Laboratory, Inc. listing. Our production is reviewed by U. L. semi-annually to assure that no production variance effects the fire-resistant properties. I knew these points are important to you. When you weigh them against the difference in the initial cost of the fluid, the overall picture has to favor THERMINOL-FR. .....A. : A A- ./A . - . A . Perh?.ps the strongest evidence I can present at this time is the following list of oil companies, most of them marketing a heat transfer fluid of their own, who have selected THERMINOL-FR because of its obvious superior characteristics: Gulf Gil Company, Las Vegas, Nevada Ethyl Corporation, Baton Rouge, Louisiana Sun Oil Company, Dallas, Texas Universal Oil Company, Des Plaines, Illinois " Continental Oil Company, Ponca City, Oklahoma Esso Research & Engineering, Linden, New Jersey Phillips Petroleum Company, Bartlesville, Oklahoma Sinclair Refining Company, New York, New York Brea Canyon Oil Company, Los Angeles, California Lubrizol Company, Painesville, Ohio . Shell Oil Company, Santa Barbara, California Standard Oil of California, Los Angeles, California Standard Oil of Ohio, Cleveland, Ohio Wilshire Oil Company, Los Angeles, California Of interest is that we are assigning a knowledgeable and talented young nan exclusively on THERMINOL for the New York area. He is Henry Gilbert (who will reside in New York City) and he will be contacting you to introduce himself shortly after he gets settled. Hal, by all means let me know how else we can help. You may, of course, contact me here in St. Louis any time, or contact Hank Gilbert through our New York office after April 9. Cordially, S. Shaw Market Specialist Functional Fluids jf DSW 343164 9 STLCOPCB4083947