Document aJeQRLzgy8m9a8yB6rnvz5b2R
September 7, ljt>6
AIR-.'AIL
Mr. Elmer P. Wheeler Industrial Ilyrienist ."ensanto Chemical Co. 1700 3. Second Street 3t. Louis 4* Missouri
Dear Elmer:
I am enclosing two letters for your consideration in relation to the concentration of Aroclor 1242 in air that is saturated with Pydraul P-1^0. The ne letter contains results obtained in three phases of this study whereas the other con ains only the results obtained in the latter 2 phases. We believe the results obtained in each successive phase are more nearly exact. We believe that there may have been a slight crack in the Millipore filter paper while samples wre being obtained during the first phase* thus giving results a little high. This was not the case in the second or third studies. The few samples obtained during the third study are believed better (and to be fairly aoourate) than those determined during the second si nee they were sampled for one our rather than 15 mlnutea resulting in a quantity of chloride that was on the csoter of the analytical curve.
We loubt that with the sensitivity of the method and ths number of samples taken that a significant distinction can be raede between (l)one and two bubblers of Pydreul F-150 for venerating the atmosphere and (2)that an lnorcaae in concentration would be obtained by bubbling the air through a third bubbler containing Pydraul F-lpO. Such statistical distinction could be obtained If sufficient samples were collected. The number of samples required could be statistically ascertained* however, this would be a rather large number of samples. For example, it would require between 50 and 100 samples to ascertain a statistical difference of one mioro>-ram per liter on data with leviationa like that obtained in the first phase. (Each.sample requires two analyses* le, one for eaoh of the two absorption towers collecting the thermally decomposed Aroclor 12424 SlrW our tevlatlon has
DSW 018543
STLCOPCB4005087
Paf* 2
Mr. timer P. Wheeler September 7 19^6
decreased In the sec nd and third phases this figure would probably be reduced a little for data such as we have obtained most rec-ntly.
Sincerely ;ours,
Jh?:fU '
cc: Mr. Wntolcr (Wash!npton,D.C.)
Joseph l*'. Treon
P.S. I have sent a photo with the oriplnal letter 'o St. Louis; also I have enclosed a photo with the c-py of the letter to Washington. Since i am very low on these pictures will you keep one and return the
other.
DSU 018544 STLCOPCB4005088
September 7, 1956
Mr. Slmer P. wheeler Industrial Hygienist Monsanto chemical Co. 17Jo 6. SeCwnd Street St. Louis 4* Missouri
Menr Mr. Wheeler:
We hav venerated a sa urated atmosphere of ?y iraul i'-l50 by eana of the equipment in the e; :losed photo. raph.
Air from a "ust Rotary Blast and Suction pump (A) at the rate of Id liters per minute as measured by a rotameter (P) passed through either _ne or two bubblers (C and D) each containing 500 ml of Pydraul E-150. (The bubblers were 9*75" high (0.0.) and 2.9" In diameter 0.0., the air entered the bubbler through a fritted glasa thimble, 7/8" a 3 3/4- ) The air-borne Pydraul F-150 was paeaed through an lmplnger bottle (E) and then through a Mlllipore filter (f) before entering a "leas tube (0) on wnich was surmounted a thermometer. (The room temperature was maintained at either 72* or 8Q*E by means of an air-conditioning unit.) Nine liters of the sample ware discharged into the room through an upright tube above H. Air at the rate of one liter per minute was drawn from a sampling port (H) and passed through a rurnace (J) (maintained at 850*-90Q*C and equipped with a platinum etrin). The furnace was humidified by means of a wet wick at I. The thermally decomposed Arocler was eolleetsd in two midget bubblers (K) in series* (lie bubblers each contained 10 ml of 0.1 N NaOTl and were equipped with fritted 3lass thimbles.) A drying tower (L) preceded a capillary flowmeter (m) and the sampling pump (N).
The thermally decomposed chloride was determined turbidirjp^jTically as given in my memo of July 7, 1956, e CGrt wenable to eliminate the step for the removal of phospiuate since the phosphate did not intercfere because it was soluble in nitric acid.
DSW 018545
STLCOPCB4005089
Fags 2
Mr. Slnar P. Wheeler
leptsaber 7 195 6
The result obtained were as follows in one stud; (Mo. 1) which Included 24 samples (4.6 analyses) each of which was collected for 15 nlnutes.
Number of Bubblers for Generation of Vapor
Temperature CF)
Average of sis samplesI microgrt
of uroelor 1242/ liter
1 72 4.8 2 72 6.1
2 80 5.2
2 80 6.5
These smaples are undoubtedly high, slnoe it was found after their analyses that a snail oraok was present in the Mllllpore filter.
The resulte of a second study on a similar nuafcer of sanplea (15 nlnutes for eolleotioa) were as follows:
Hunker of Bublers far Oeneratloa
of Vapor___
rnTemperatur ____
Average of six saapleaj microgram
of Aroelor 1242/
ii*
1 72
2 1
ll
3.5 1.9 2.5
2
Are. of 7
Are. _/
A few seaolee la a third experiaeat were oolleeted for a period of oao hour, those results were as follows:
Hunber of Bubblers for Seneratie- of Tales
1 2 1 2
temperature CF)
Vuaber of
Sarnies
Average Micrograms of
Aroalor 1242/ liter
72 2 0.95 72 2 2.25
80 1 1.1 80 1 Ul...
Are. of Ave
1.55
t-
i v* a r**'
y
<*<
DSW 018546
STLCOPCB4005090
Page 3
Mr. Eimer P. Wheeler September 1, 193^
At 7U$ mm and 25*C one mi crop.ram of Aroclor 12l|2 vapor is equivalent to 0,09^9 ppm by volume (1 m ;/l ~ 96.9 pm). Therefore 2. <3> y/1 " 0.2>6 pm. t.nd 1.53 y/1 = 0.130 ppm. Although thero are fewer samples in this latter determination, I am inclined to believe It is probably the best value.
Because of the number of samples and the deviation in them it. is doubted that the difference between 1 and 2 bubblers on the one hand and between 72' and 6Q'K on the other hand can be statistically difierentiated without many more samples.
Wo shall proceed with the determination of the threshold odor eoncentratio and ef feci.i veness for removal of Pydraul K-ljO bv passa-e through KLA very shortly.
Sincerely yours,
JFT: fk
cc: Mr. Elmer Wheeler (Washington, D.C.)
Joseph 1. Treon
DSW 018547
STLCOPCB4005091
THE KETTERINO LABORATORY COLLEGE OF MEDICINE--EOEM AVENUE CINCINNATI 19, OHIO
' UNIVERSITY OF CINCINNATI
DEPARTMENT OF PREVENTIVE MEDICINE AND INDUiTNIAL HEALTH
CABLE ADORE**: KITU1. CINCINNATI TELEPHONE: CAnfoi 1414
September 7> 1956
Mr. Elmer P. Wheeler Industrial Hygienist Monsanto Chemical Co. 170U S, Second Street St. Louis 4> Missouri
Dear Mr. Wheeler:
We have generated a saturated atmosphere of Pydraul F-150 by means of the equipment in the enolosed photograph.
Air from a Gast Rotary Blast and Suction pump (A) at the rate of 10 liters per minute as measured by a rotameter (B) passed through either one or two bubblers (C and D) each containing 500 ml of Pydraul F-150. (The bubblers were 9*75" high (O.D.) and 2.9" in diameter O.D., the air entered the bubbler through a fritted glass thimble, 7/8" x 3 3/k- ) The air-borne Pydraul F-150 was passed through an impinger bottle (E) and then through a Millipore filter (f) before entering a glass tube (G) on which was surmounted a thermometer. (The room temperature was maintained at either 72* or 80*F by means of an air-conditioning unit.) Nine liters of the sample were discharged into the room through an upright tube above H. Air at the rate of one liter per minute was drawn from a sampling port (H) and passed through a furnace (J) (maintained at 850*-900*C and equipped with a platinum strip). The furnace was humidified by means of a wet wick at I. The thermally decomposed Aroclor was collected in two midget bubblers (K) in series. (The bubblers each contained 10 ml of 0.1 N NaOH and were equipped with fritted glass thimbles.) A drying tower (L) preceded a capillary flowmeter (M) and the sampling pump (N).
The thermally decomposed chloride was determined turbidinjptypically as given in my memo of July 7 1956, except we^sme to eliminate the step for the removal of phosphate, since the phosphate did not interefere because it was soluble in nitric acid.
DSW 018548
STLCOPCB4005092
Page 2
Mr. Elmer P. Wheeler September 7> 1956
The results obtained were as follows in one study (No. 1) which included 24 smaples (48 analyses) each of which was collected for 15 minutes.
Number of Bubblers for Generation of Vapor
Temperature ___ IIF)_____
Average of six
samples; micrograms of Aroclor 121+2/ 1 i ter
1 72 4.8 2 72 6.1 1 80 5.2 2 80 6.5
These samples are undoubtedly high, since it was found after their analyses that a small crack was present in the Millipore filter.
The results of a second study on a similar number of samples (15 minutes for collection) were as follows:
Number of Bublers for Generation
of- Vapor
Temperature 1P)
Average of six samples; mi croc-rams of Aroclor 1242/ liter
1 72
3-5
2 72
1.9
1 80
2.5
2 80
2.7
Ave . of l 2765
Ave .
/
A few samples in a third experiment were collected for a period of one hour. these results were as follows
Number of Bubblers for Generation of Vapor _
1 2 1 2
Temperature ___ 1*F)_____
Number of
Samples'
Average
Micrograms of Aroclor 1242/ liter
72 . 2
72 2 80 1 80 i
0.95 2.25 1.1
JL2-
Ave. of Ave.
1.55
DSW 018549
STLCOPCB4005093
Page 3
Mr. Elmer P. Wheeler September 7 1956
At 745 mm and 25*C one mi crogram of Aroclor 1242 vapor is equivalent to O.O969 ppm by volume (1 mg/l = 96.9 ppm). Therefore 2.65 y/l = 0.256 ppm and 1*55 y/1 = 0.150 ppm. Although there are fewer samples in this latter determination, I am inclined to believe it is probably the best value.
Because of the number of samples and the deviation in them it is doubted that the difference between 1 and 2 bubblers on the one hand and between 72 and 80 "F on the other hand can be statistically differentiated without many more samples.
We shall proceed with the determination of the threshold odor concentration and effectiveness for removal of Pydraul F-150 by passage through MEA very shortly.
Sincerely yours
I
JFT:fk
cc: Mr. Elmer Wheeler (Washington, D.C.)
<iosseph P'. Treon
OSW 018550
STLCOPCB4005094