PCB EXPOSURE CONTROL PREMISE Current data Indicates that PCB type materials may be more hazardous to working personnel than had previously been con sidered. Based on these facts, the control of exposure of workers where PCB's are manufactured or used should be re examined and made more restrictive. Currently the American Conference of Governmental Industrial Hygienists (ACGIH) shows threshold limit values for chlorodiphenyl (42% chlorine) (Arochlor 1242) of 1 mg/M^ and for chlorodiphenyl (54% chlorine)
i are below these numbers.
Very limited analysis in the > that the airborne concentrations
The two routes of entry of importance in PCB manufacture and use are vapor inhalation and skin absorption. Although there is no evidence that skin absorption presents a significant hasard, it is probable that some absorption does occur. Since the vapor concentrations are quite low in the operating depart ment that manufactures this product, some type of biological test 16 needed to determine if skin absorption is occurring, and if so, to what degree. An analytical program must be de vised to determine if PCB analysis of the urine is feasible, and can be used as an exposure indicator.
MONS 04*501
Page 2
?. RECOMMENDED METHODS OP CONTROL A. Urine Analysis for PCB If, indeed, PCB can be analyzed in human urine and levels can be determined that represent the very best operation from an exposure standpoint, a routine urine sampling pro gram should be initiated with limits established for urinary PCB levels that are unacceptable.
B. Vapor Inhalation Vapor inhalation is a problem only when Aroclor is heated above ambient temperature. Where vapor exposure is possi ble, air supplied respiratory protection must be worn. An
S airborne control limit for all PCB vapor exposure must be set as low as is practicable and certainly below the stan dard for PCB with the lowest TLV currently listed in 29 CFR 1910.93 which is chlorodiphenyl (5**# chlorine) (Aroclor 1254). Routine air monitoring must be conducted.
C. Skin Any operation, particularly maintenance operations, where liquid PCBs or PCB mists can come in contact with the akin, skin protection including gloves and suitable impervious clothing should be used. Where heated Arpclor is present resulting in vapor exposure, air supplied respiratory equipment and impervious clothing both must be
HONS 044502
Page 3
used. For example. In maintenance work on a chlorlnator that has been drained but is still hot, air supplied res piratory protection and impervious clothing should both be used.
D. Exposure Registry An exposure registry must be established on all PCB workers. All urine sample results, if this method proves effective, all air sampling data must be recorded along with all appropriate health information. This registry would be a composite, therefore, of all medical and health data, all airborne exposure data, and all biological ex cretion data if appropriate. This registry should be so constructed that each individual employee can have avail able to him all data that pertains to him for examination or transfer to any subsequent employer.
E. Environmental Contamination
We would recommend that all means be exercised, either
through engineering changes or through work practice changes
to minimize environmental releases, either by air, water or
through solid residues. In short, we would recomswnd that
all means within the limits of economic feaalbility be
utilized to limit releases of these materials into the en
vironment .
Jack T. Oarrett
HONS 044503