1028 CHAPTER 47 ,1954 Guide HI}* At = total heat transfer coefficient, Btu per (hour) (square foot) (Fahrenheit degree) i - ` A = area of heat transfer and evaporation, square feet. , X = latent heat of evaporation at t, Btu per pound. * k, = mass transfer coefficient, pounds per (hour) .(square foot) (atmosphere).-. at = (/. -- t.) = temperature difference between air and surface of evaporation, Fahrenheit degrees. ' ta = air temperature. Fahrenheit, ; . U -- temperature of surface of evaporation, Fahrenheit. . Op = (p. -- p) = vapor pressure difference, atmospheres, p, = vapor pressure of water at fi, atmospheres, p, = partial pressure of water vapor in air, atmospheres. When ht -- hc, the coefficient of heat transfer by convection only, then t, under equilibrium conditions becomes the wet-bulb temperature of the air, and p, is the vapor pressure at this temperature. If heat is also supplied by radiation, then ,ht is the sum (hc rf- hr) where hr is the radia tion coefficient and hc is the convection' coefficient, and t, becomes higher than the wet-bulb temperature. A similar result occurs when heat reaches the surface of evaporation by convection and conduction. When the surface is at the wet-bulb temperature, the value of Ap in millimeters of mercury, is almost exactly one-half the wet-bulb depression (ta -- L), in Centigrade degrees. Effect of Air Velocity. The principal effect of air velocity is on hc and fc,,, since the rate of transfer of heat and mass in the constant-rate period depends mainly on the rate of diffusion, of heat and vapor through the air film at the surface of the solid, and air velocity is the chief factor affecting the thickness of this film. The influence of air velocity may be expressed by the following relationship:3 h,, = 0.0128 G > where Ac = convection heat transfer coefficient, Btu per (hour) (square foot) (Fahren heit degree). O = mass velocity of dry air, pounds per (hour) (square foot). For estimating the constant rate in drying from plane surfaces with air flow parallel to the surface of evaporation and with no radiation or conduction effects, the following heat transfer expression can be used: dw 0.0128G-A ,. de ~ A ^W g) where tw = wet-bulb temperature of the drying air, Fahrenheit degrees. Heat transfer coefficients, rather than mass transfer coefficients, should be used to estimate drying rates, because heat transfer coefficients are generally more reliable, and, unless the temperature of the drying syJ|a is measured, it must be calculated from heat transfer considerations betp mass transfer coefficients can be applied for drying-rate predictions, assumption that the surface of drying is at the wet-bulb tempera of , the air, introduces a more serious error in the computation of m transfer than of heat transfer. ^ Determination of True Surface Temperature. Frequently, radiation an conduction are of sufficient magnitude to cause the temperature of evaP oration to exceed the wet-bulb temperature of the air. When this cc^,,, it is necessary to estimate the true surface temperature in order to calcnia Industrial Drying Systems 1029 the constant rate. This may be done by-means of a heat balance equating the total heat transferred by convection, conduction, and radiation to the latent heat of evaporation. Constant-Rate Period in Through-Circulatum Drying. The equation for estimating the rate of evaporation when air. flows across a free water surface must be modified for the case of air-flow through a permeable bed of solids. The constant rate in through-circulation drying depends on the; air rate, air temperature, air humidity, size of the particles making up the permeable bed, and physical characteristics of these particles.4 The following general expression for the constant rate in through-circula tion drying for the system water and air, was developed5 from experiments on the rate of evaporation of . water from the surface of wet spheres and cylindrical particles with through-circulation of air: : where dW _ 0.42aG" "(A/f),, 0.37c^G" "aU 66 I)* " ^ ; Xp.Z)- w dW = constant rate, pounds of water per (hour) (pound of dry stock). o = drying area, square feet per'cubic foot of bed volume. G = superficial mass velocity, pounds of dry air per (hour) (square foot). = logarithmic mean of inlet and outlet humidity driving force across the air film adjacent to the particle through which the .water vapor diffuses," pounds per pound (the, surface humidity is taken as the humidity corres ponding to the wet-bulb temperature of the drying air). p* = bulk density of dry granular bed, pounds per cubic foot. Dc = average diameter of particle, feet. Mm = logarithmic mean difference between temperature entering and leaving the bed and the wet-bulb temperature, Fahrenheit degree). c, = humid heat, Btu per (pound of dry air) (Fahrenheit degree). X = latent heat of evaporation, Btu per pound. ?nn^Ua^0n aPP^es wben the Reynolds number DPG/u is greater than oOO, where u is the viscosity of the air stream. For values less than 300, a modification of Equation 4 has been presented.6 Evaporation from Liquid Drops. For the important problem of spray ^ymg, evaporation rates of liquid drops must be estimated. Below a value of Reynolds number (DpG/p) of 10 for spherical particles, the heat ransfer coefficient across the gas film surrounding the drop is given by where (6) h ~ film heat transfer coefficient, Btu per (hour) (square foot) (Fahrenheit de gree). = thermal conductivity of gas film, Btu per (hour) (square foot) (Fahrenheit degree per foot). ^Equation 5 is applicable when the Reynolds number for liquid drops a ?ss ^an 10. Drop diameters are almost always less than 500 microns, Q usually in the range of 20 to 150 microns. transf Iate * evaPoratin f drops may be expressed in terms of heat ;0jS er or mass transfer. In terms of heat transfer, the evaporation rate 13 given by the equation: