Document aJBDn6yb2awmJMy7Gwvk1RD6B

Air Conditioning Automatic Heating Systems The Quincy Stove Manufacturing Co. Quincy, Illinois--U. S. A. MONOGRAM Automatic Oil Burning Furnaces MONOGRAM TurbulentFlame Vaporizing Oil Burner An important factor in the high efficiency of all MONOGRAM Heating Equipment is the MONOGRAM Turbulent-Flame Vapor izing Oil Burner--a new method of oil burning. No moving parts, nor frequent cleaning or servicing. Products of com bustion are confined to the heating drum; and oil vapors, gas, or products of combus-. tion can not escape into the building. The burner is continuously in operation--either on low or high flame, and maintains sufficient burner temperature to completely vaporize oil so that combustion occurs immediately when oil enters the burner--quick, efficient. The cycle of operation from low fire to high fire and again reducing to low fire is gradual and without pun or explosion. In case of electric power failure the burner operates on low fire without danger of flooding, and can be operated manually by adjusting the oil flow and the draft regulator as required. Burner approved by the Underwriters' Lab oratories, Inc. Ten Furnace Models Three sizes of Booster Gravity Units for quick and inexpensive change from coal to automatic oil heating, equipped with limit control, mechanical draft, and thermostat--these three models may be equipped with blowers for Full-Forced Circulation. Three sizes of Full-Forced Winter Air Conditioning units complete with air filters, automatic humidi fiers, blowers, economizers, mechanical draft, limit control, blower switch and thermostat. An up right Full-Forced Winter Air Conditioner for base ment or utility room installation equipped with separate blower for draft and air, limit control, blower switch and thermostat. Heating drum 12 to 14 gauge--all cabinets insulated with one inch fibreglas. Mechanical draft only on high fire. Low fire operates on .02 inch draft. Special oil service station models from 50,000 to 72,000 Btu at bonnet--efficiency obtainable 80 to 81.7 per cent cfm 550 to 850. *-- Specifications for MONOGRAM Oilfire Furnaces Type of Furnace Booster Gravity Full-Forced Warm Air Full-Forced Winter Air Conditioner Upright Model No.......... 75 100 200 76 103 203 125 150 250 102 Btu Rating at Bonnet. . 75,000 90.000 125,000 75,000 90.000 125.000 90.000 120,000 150.000 75,000 Per Cent Efficiency Obtainable............... Air Delivery--cfm....... 80 82 82 80 82 82 84 84 84 so 400-700 800-1400 1000-1600 800-1400 800-1400 1000-1600:800-1400 Cabinet Floor Size--In. 26'/,x25'/, 30x30 36x36 26%x52'/, 30x56 Cabinet Height--In.... 50'/, 60 60 50'/, 60 36x66 26'/,x49l/i 30x56'/2 36x68'/j | 27x27 60 50'/, 60 60 i 71 Height With Bonnet... M'/t 74'/. 74'/, ! Max. GaL Oil per Hr.... 0.69 0.81 1.12 0.69 0.81 1.12 0.80 1.05 1.32 | .69 Min. Cal. Oil per 24 Hr. 1.50 1.00 1.50 1.50 1.00 1.50 1.50 1.00 1.50 i 1.50 New MONOGRAM Patented Burner vaporizes oil quicker--more completely, then induces both primary and secondary air in proper relation to oil, producing the highest known operating efficiency. Double baffle heat unit made possible by shorter, wider flame, stops rush of heat out the flue, creates a lower heating zone which com bined with the clean, perfect combustion produces unheard of operating efficiencies. 886 / Air Conditioning Automatic Heating Systems Williams Oil-O-Matic Heating Corporation Manufacturers of Automatic and Manually Controlled Fuel Oil Burners, Year 'Round Air Conditioning Systems, Williams Ice-O-Matic Compressors Bloomington, Illinois WILLIAMS OftO MATir PRODUCTS 20`4 G,aybar v^coouno'*New York, N. Y. OIL BURNERS Williams Oil-O-Matic Lo-Pressure oil burners are offered in 6 sizes ranging in capacity from % to 25 gallons of fuel oil per operating hour. Oil-O-Matic Lo-Pressure burners can be installed in any type or size heating plant within this range, or larger where multiple units are used. Williams Oil-OMatic Lo-Pressure oil burners feature exclusive patented Thrift Meter fuel control. This de vice actually meas ures oil drop by drop to fit the exact requirements of any heating plant. Williams designed, precision-built HiPressure burners were developed for those jobs where first cost is most important. Three sizes range from .65 to 7 gallons per hour. How to Decide Size of Burner For low pressure domestic boilers, 1 gal of fuel oil per hour (140,000 Btu) is re quired for approximately: 300 sq ft of steam radiation or its equiva lent. 480 sq ft of hot water radiation or its equivalent. 70,000 Btu when using hot air furnace ratings. 24 sq ft steam boiler heating surface (or 2.2 hp). For exact detail data, see Oil-O-Matic Installation and Service Manual. Heating Capacities of Oil-O-Matic Burners Domestic 1 Shipping R Weight. Lb | Length, in. | Width, in. Model Gals. Fuel s Oil per Oper ating Hour sec '8 X 0. X a. Mini Maxi mum mum K-150 K-3 K-4.5 X-7 J-1600 JJ HP-1 HP-3A HP-7 126 180 190 200 220 295 90 90 150 29 15'/, 1/10 1750 .50 1.50 30 15V, 20V, 1/1(1 1750 1.00 3.00 33'/2 20'/, 22'/, 1/5 1750 1.35 4.50 26V, 22'/, 21V, 1/5 1750 4.00J 7.00 45 m 2J'/2 1/2 1800 8.00 15.00 50 32 24 1 1800 12.00 25.00 20'/, 14V, X 1/16 1775 .65 1.00 22V, !6'/2 X 1/12 1730 1.35 3.00 26'/2 20 2iy, 1/5 1750 3.50 7.00 X--Adjustable. Standard draft pipe 11 in. 17-in. length draft pipe optional. Standard electric current is 110-volt, 60-cycle. WINTER AIR CONDITIONERS Williams Oil-OMatic Winter Air Conditioners automatically clean, freshen, ventilate, humidify, heat and circulate air throughout the house. Electrically welded heat ex changers preclude possibility of air or gas leaks. Exclusive Anti-Pulsator elim inates starting vibration. Triple Thrift Lo-Pressure operation. Also available with Hi-Pressure burner. Built in 5 sizes to meet every heating load. BOILER BURNER UNITS Williams Oil-O-Matic oil-fired boilers are avail able in 3 models. The Lo-Boy (illustrated), in 3 sizes for steam, 3 for hot water; Residential Steel--4 sizes for steam, 4 sizes for hot water; and the Water Base--3 sizes for steam, 3 for hot water. Oil-O-Matic oil-fired boilers furnish low cost winter heating and economical year 'round domestic hot water. These complete units furnished with either Oil-OMatic Lo-Pressure or Williams Hi-Pressure burners. WATER HEATERS Williams Oil-OMatic horizontal type water heaters are com pact, completely auto matic, self-contained units. Lo-Pressure operation makes it pos sible to burn heavy domestic fuel oil for utmost economy. Unique Triple Flame Travel combustion chambers aids still further in economy. Where home is already heated with oil, fuel may be drawn from the same tank. WHA* WHBt WHCJ 600 885 1385 Water Heaters 57 75 23 90 29 28 l/iolf800 28 1/101800 '/2 34 1/101600 1 13/4 uuv^uk. au I' litre, W &H1 P< ---------- tOutput 90 F rise, 120 gal per hour, JOutput: 90 I rise, 210 gal per hour. 887