Document aDkrzkbGR5ZZnERN8dadzj8y9

V Ambient Asbestos Fiber Concentrations Case: 48106-3 AKT Bell Laboratories 600 Mountain Avenue Murray Hill. New Jersey 07974 Phone (201) 582-3000 PLAINTIFF'S EXHIBIT May 9, 1984 R. Naser Bell Ccnmunications Research Roan 6128-F3 295 North tople Avenue Basking Ridge, New Jersey 07920 Dear Mr. Naser: I have compiled the results of all our asbestos analyses over the past two years to provide information of background or ambient fiber concentration and the feasibility of setting a 0.1 fiber/an3 standard. Of all the analyses, there were a total of 421 samples submitted which did not specify any work operations requiring disturbance of asbestos-containing materials. It is these sanples that I consider samples of ambient fiber concentrations. Of the 421 sanples, the highest concentration noted was one sample at 0.1 fibers/an3. All other sanples were less than 0.08 fibers/an3. In fact, only 90 sanples had detectable fiber concentrations (more than 10 fibers per 100 microscope field area over blank counts). I have attached a histogram plot of the frequency distribution of the fiber concentrations. Ihe limit of detection was used as the concentration for all "None Detected" sanples. If you have any further questions on this subject please call. MH-77621-CPL-jve Copy to: J. M. Degen - BCR P. A. Huggins K. D. Tiait W. J. Schreibeis G. M. Wilkening CONFIDENTIAL Charles P. Lichtenwainer (201) 582-5399 003674 * - r?.ealienci PuTRfao'ncM of f\Nisievrr {^stesnt ^ieet ClcMcevmwieHS CtHCftnefinaA (foew /cn?) . 36 *2 ISSUE O< s* COW :IDENTIAL fSt DMWN , 5^-V) TITLE 003675 BELL TELEPHONE LABORATORIES MCOIIFOftAUO SHEET